Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Genesis Sample Return Capsule Overview

I. Simple Entry Capsule Concept: a) Spin-Stabilized/No Active Control Systems; b) Ballistic Entry for 11.04 km/sec Velocity; c) No Heatshield Separation During Entry; d) Parachute Deploy via g-Switch + Timer. II. Stardust Design Inheritance a) Forebody Shape; b) Seal Concepts; c) Parachute Deploy Control; d) Utah Landing Site (UTTR). III. TPS Systems a) Heatshield - Carbon-Carbon - First Planetary Entry; b) Backshell - SLA-561V - Flight Heritage from Pathfinder, MER; d) Forebody Structural Penetrations Aerothermal and TPS Design Process has the Same Methodology as Used for Pathfinder, MER Flight Vehicles.

Willcockson, Bill↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The CDC Biofilm Reactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Biofilm Reactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Biofilm Reactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target biofilm reactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Biofilm Reactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

Efficient Oculometric Assessment of Altered Neural Function

Eye movements have long been known to shed light on the locus and nature of serious brain injuries and pathologies. Recent scientific findings linking eye movements and higher-order psychometric performance and recent technical advances in eye-tracking precision have enabled the harnessing of an assortment of oculometrics as sensitive and reliable biomarkers of mild neural impairment across a wide range of stressors and brain regions. Oculometrics is, therefore, a promising new tool for the assessment of spaceflight effects on sensorimotor performance and on the effectiveness of candidate countermeasures, even with small sample populations

eye movements↗

Design, implementation and flight testing of PIF autopilots for general aviation aircraft

The designs of Proportional-Integrated-Filter (PIF) auto-pilots for a General Aviation (NAVION) aircraft are presented. The PIF autopilot uses the sampled-data regulator and command generator tracking to determine roll select, pitch select, heading select, altitude select and localizer/glideslope capture and hold autopilot modes. The PIF control law uses typical General Aviation sensors for state feedback, command error integration for command tracking, digital complementary filtering and analog prefiltering for sensor noise suppression, a control filter for computation delay accommodation and the incremental form to eliminate trim values in implementation. Theoretical developments described in detail, were needed to combine the sampled-data regulator with command generator tracking for use as a digital flight control system. The digital PIF autopilots are evaluated using closed-loop eigenvalues and linear simulations. The implementation of the PIF autopilots in a digital flight computer using a high order language (FORTRAN) is briefly described. The successful flight test results for each PIF autopilot mode is presented.

Broussard, J. R.↗

MISSE-11 Ground Experiment Control

Back during the Apollo missions, when astronauts were being sent to the moon to explore and further scientific knowledge by conducting experiments and collecting samples for scientists back on Earth, they were faced with a surprising problem. It was discovered that the moon’s surface is covered with dust that has electrostatic properties, which would stick to suit and equipment. This hindered the functionality of the astronauts’ space suits, solar panels, optical instruments, among other exposed surfaces due to the jagged geometry of the dust which would damage said equipment. To resolve this issue, the Electrostatics and Surface Physics Laboratory (ESPL) came up with the solution of using an Electrodynamic Dust Shield (EDS)1 that uses electrostatic forces to move particles across a surface. Varieties of this dust shield have been developed for different applications. The purpose of the Materials International Space Station Experiments 11 (MISSE-11) is to experiment a payload that contains the dust mitigation technology to be flown to space for one year and an identical payload will be on earth, under vacuum, in the Electrostatics and Surface Physics Laboratory. The space payload was prepared prior to our arrival and shipped to fly on the International Space Station (ISS). The payload staying on the ground is going to act as a control for the experiment so that we may compare it to the payload that was flown in space. During our time at Kennedy Space Center, we were tasked with building and start testing the ground control unit of the MISSE-11 payload. To complete our task for the ground control unit, we constructed a new vacuum chamber setup and added automated aspects, procured the necessary flight electronics, designed and communicated for the machining of the payload frame, and performed functional and thermal testing on the electronics to the same original operational standards. Some modifications were made where possible, without affecting the performance of the samples, to be efficient with the production of the control unit while keeping important aspects identical. The experiment is now nearly complete, and testing will be starting within the next few weeks.

MISSE↗

Performance Measures for Aircraft Landings as a Function of Aircraft Dynamics

A theory of performance measurement for operator controlled systems is presented. The theory permits synthesis of a system performance measure which scores performance on successive data samples based on the impact of the sampled performance on the overall summary of performance. The development of measures for aircraft carrier landings for the glide path and angle of attack control channels is documented. While developing the performance measures, the measures used previously were evaluated and were found to lack the necessary discrimination capability. The previously used measure, the RMS of deviations from the glide path, can, for instance, provide identical scores for both satisfactory and unsatisfactory flight paths. Two types of performance measures developed for aircraft landings are described. Also, an argument is given for the need to test performance measures prior to their use. A suggested test of the measures is offered.

Connelly, E. M.↗

Geometric correction process for the Landsat-4 Thematic Mapper

The processing approaches which form the basis of the Landsat-4 Thematic Mapper (TM) geometric correction system are summarized. The correction is accomplished in two phases. In the first phase, correction data are generated. The spacecraft position, TM frame attitude, TM scanning mirror position, and detector sampling are found as a function of time through a combination of flight segment measurements, ground segment modeling, and control point information. The data, along with the earth position and geoid model, are used to determine the earth location for each TM image sample. Then, using map projections, correction data can be generated which define the location of each TM image sample on the output coordinate system. In the second phase, the correction data are used to resample TM detector samples onto the output coordinate system.

Beyer, E. P.↗

JSC systems using solid ceramic oxygen electrolyte cells to measure oxygen fugacites in gas-mixing systems

Details are given for the construction and operation of a 101.3 KN/sq meter (1 atmosphere) redox control system. A solid ceramic oxygen electrolyte cell is used to monitor the oxygen fugacity in the furnace. The system consists of a vertical quench gas mixing furnace with heads designed for mounting the electrolyte cell and with facilities for inserting and removing the samples, a simplified version of a gas mixing apparatus, and devices for experiments under controlled rates of change of temperature. A thermogravimetric analysis system employing these techniques of redox control and measurement is also described. The calibration and maintenance of the system are discussed.

Williams, R. J.↗

Low-power portable geophysical data acquisition system and its use in geomagnetic measurements

A low-power portable data acquisition system presently in use for geomagnetic measurements is described. The system is composed of a data-processing system containing a low-power microprocessor, a 9-track digital tape recorder, and a rechargeable battery pack. The magnetometer is a low-power three axis fluxgate design. Under program control the data processing system keeps track of time of day and date, samples three analog magnetometer outputs at intervals of either 0.4 or 2 s, digitizes the data to 15-bit resolution, and, depending upon relative magnetic activity, decides upon data compression to increase the tape storage capacity. It also monitors and records internal voltages and provides self-checking functions which may be monitored through a visual readout on the control panel. The system is mounted in a rugged, weather-tight carrying case suitable for use outdoors with minimal protection. The system, including magnetometer, uses 1.6-W power and can store 5.7 Mbytes of data.

Medford, L. V.↗

Evaluation of the MICAST #2-12 AI-7wt%Si Sample Directionally Solidified Aboard the International Space Station

The US team of the European led "MIcrostructure Formation in CASTing of Technical Alloys under Diffusive and Magnetically Controlled Convective Conditions" (MICAST) program recently received a third Aluminum - 7wt% silicon alloy that was processed in the microgravity environment aboard the International Space Station. The sample, designated MICAST#2-12, was directionally solidified in the Solidification with Quench Furnace (SQF) at a constant rate of 40micometers/s through an imposed temperature gradient of 31K/cm. Procedures taken to evaluate the state of the sample prior to sectioning for metallographic analysis are reviewed and rational for measuring the microstructural constituents, in particular the primary dendrite arm spacing (Lambda (sub1)), is given. The data are presented, put in context with the earlier samples, and evaluated in view of a relevant theoretical model.

Tewari, Surendra N.↗

Lunar deep drill apparatus

A self contained, mobile drilling and coring system was designed to operate on the Lunar surface and be controlled remotely from earth. The system uses SKITTER (Spatial Kinematic Inertial Translatory Tripod Extremity Robot) as its foundation and produces Lunar core samples two meters long and fifty millimeters in diameter. The drill bit used for this is composed of 30 per carat diamonds in a sintered tungsten carbide matrix. To drill up to 50 m depths, the bit assembly will be attached to a drill string made from 2 m rods which will be carried in racks on SKITTER. Rotary power for drilling will be supplied by a Curvo-Synchronous motor. SKITTER is to support this system through a hexagonal shaped structure which will contain the drill motor and the power supply. A micro-coring drill will be used to remove a preliminary sample 5 mm in diameter and 20 mm long from the side of the core. This whole system is to be controlled from earth. This is carried out by a continuously monitoring PLC onboard the drill rig. A touch screen control console allows the operator on earth to monitor the progress of the operation and intervene if necessary.

Harvey, Jill↗

Development, simulation validation, and wind tunnel testing of a digital controller system for flutter suppression

Flutter suppression (FS) is one of the active control concepts being investigated by the AFW program. The design goal for FS control laws was to increase the passive flutter dynamic pressure by 30 percent. In order to meet this goal, the FS control laws had to be capable of suppressing both symmetric and antisymmetric flutter instabilities simultaneously. In addition, the FS control laws had to be practical and low-order, robust and capable of real time execution within the 200 hz. sampling time. The purpose here is to present an overview of the development, simulation validation, and wind tunnel testing of a digital controller system for flutter suppression.

Hoadley, Sherwood Tiffany↗

Dendritic growth of undercooled nickel-tin. I, II

A comparison is made between high speed cinematography and optical temperature measurements of the solidification of an undercooled Ni-25 wt pct Sn alloy. The first part of this study notes that solidification during the recalescence period at all undercoolings studied occurred in the form of a dendritelike front moving across the sample surface, and that the growth velocities observed agree with calculation results for the dendrite growth model of Lipton et al. (1986); it is concluded that the coarse structure observed comprises an array of much finer, solute-controlled dendrites. In the second part, attention is given to the solidification of levitated metal samples within a transparent glass medium for the cases of two undercooled Ni-Sn alloys, one of which is eutectic and another hypoeutectic. The data obtained suggest a solidification model involving dendrites of very fine structure growing into the melt at temperatures near the bulk undercooling temperature.

Wu, Y.↗

Advances in Rodent Research Missions on the International Space Station

A research platform for rodent experiment on the ISS is a valuable tool for advancing biomedical research in space. Capabilities offered by the Rodent Research project developed at NASA Ames Research Center can support experiments of much longer duration on the ISS than previous experiments performed on the Space Shuttle. NASAs Rodent Research (RR)-1 mission was completed successfully and achieved a number of objectives, including validation of flight hardware, on-orbit operations, and science capabilities as well as support of a CASIS-sponsored experiment (Novartis) on muscle atrophy. Twenty C57BL6J adult female mice were launched on the Space-X (SpX) 4 Dragon vehicle, and thrived for up to 37 days in microgravity. Daily health checks of the mice were performed during the mission via downlinked video; all flight animals were healthy and displayed normal behavior, and higher levels of physical activity compared to ground controls. Behavioral analysis demonstrated that Flight and Ground Control mice exhibited the same range of behaviors, including eating, drinking, exploratory behavior, self- and allo-grooming, and social interactions indicative of healthy animals. The animals were euthanized on-orbit and select tissues were collected from some of the mice on orbit to assess the long-term sample storage capabilities of the ISS. In general, the data obtained from the flight mice were comparable to those from the three groups of control mice (baseline, vivarium and ground controls, which were housed in flight hardware), showing that the ISS has adequate capability to support long-duration rodent experiments. The team recovered 35 tissues from 40 RR-1 frozen carcasses, yielding 3300 aliquots of tissues to distribute to the scientific community in the U.S., including NASAs GeneLab project and scientists via Space Biology's Biospecimen Sharing Program Ames Life Science Data Archive. Tissues also were distributed to Russian research colleagues at the Institute for Biomedical Problems. The expression levels of select genes including albumin, catalase, GAPDH, HMGCoA Reductase, and IGF1 were determined using RNA isolated from the livers by qPCR and no significant differences by one factor ANOVA were found between flight and ground control groups. In addition, some of the liver samples were analyzed for transcriptomic, epigenomic and proteomic profiles; some of the data sets are now available to the scientific community through GeneLabs open science data website. A second long duration mission, Rodent Research-2 (RR-2) was completed on the ISS in 2015; 20 female C57BL6J mice were successfully maintained on the ISS for various durations, with the last group of 5 animals living on-orbit for 54 days. Furthermore, we continue to expand the ISSs capabilities by introducing new on-orbit technologies including blood collection and separation, bone densitometry scanning, muscle grip strength and anesthesia with recovery. In addition, series of ground-based verification testing to fly male mice and increase the total number of mice on-orbit from 20 to 40. Subsequent missions will provide the capability to return live mice from the ISS animals to evaluate recovery on Earth, further expanding operational and science capabilities of the RR project on the ISS.

Choi, S. Y.↗

Maneuver Design and Calibration for the Genesis Spacecraft

Genesis is the fifth mission selected as part of NASA's Discovery Program. The objective of Genesis is to collect solar wind samples for a period of approximately two years while in a halo orbit about the Earth-Sun L I point. At the end of this period, the samples are to be returned to a specific recovery point on the Earth for subsequent analysis. This goal has never been attempted before and presents a formidable challenge in terms of mission design and operations, particularly planning and execution of propulsive maneuvers. To achieve a level of cost-effectiveness consistent with a Discovery-class mission, the Genesis spacecraft design was adapted to the maximum extent possible from designs used on earlier missions, such as Mars Global Surveyor (MGS) and Stardust, another sample collection mission. The spacecraft design for Genesis is shown. Spin stabilization was chosen for attitude control, in lieu of three-axis stabilization, with neither reaction wheels nor accelerometers included. This precludes closed-loop control of propulsive maneuvers and implies that any attitude changes, including spin changes and precessions, will behave like translational propulsive maneuvers and affect the spacecraft trajectory. Moreover, to minimize contamination risk to the samples collected, all thrusters were placed on the side opposite the sample collection canister. The orientation and characteristics of thrusters are indicated. For large maneuvers (>2.5 m/s), two 5 lbf thrusters will be used for delta v, with precession to the burn attitude, followed by spin-up from 1.6 to 10 rpm before the burn and spin down to 1.6 rpm afterwards, then precession back to the original spin attitude. For small maneuvers (<2.5 m/s), no spin change is needed and four 0.2 lbf thrusters are used for Av. Single or double 360 deg. precession changes are required whenever the desired delta v falls inside the two-way turn circle (about 0.4 m/s) based on the mass properties, spin rate and lever arm lengths based on thruster locations. In such instances, delta v resulting from spacecraft precession cannot be used effectively as a component of the desired delta v, and must therefore be removed by precessing at least one complete revolution around the turn circle. To eliminate cross-track execution errors, a second revolution in the opposite direction would also be performed. This paper will address the design of propulsive maneuvers in light of the aforementioned challenges and other constraints. Maneuver design will be performed jointly by the Navigation Team at JPL and the Spacecraft Team at LMA, based on the process indicated . Typical maneuver timelines will be presented which address considerations introduced by attitude changes. These include nutation, which is introduced by precessing or spinning down and must be given sufficient time to damp out prior to execution of subsequent events, as well as sun and earth pointing constraints, which must be considered to ensure sufficient spacecraft power and to minimize telecommunications interruptions, respectively. The paper will include a description of how individual propulsive maneuvers are resolved into components to account for delta v from translational burns and spacecraft attitude changes required to carry out such maneuvers. Contributions to maneuver delta v arising from attitude changes, based on mass properties for the period just after launch, are indicated. Similar curves will be presented spanning all mission phases from launch through return. A set of closed-form equations for resolving maneuver components, base on a specific delta v required for correction or deterministic changes to the spacecraft trajectory will be presented, as well. In addition to nominal maneuvers, special calibration maneuvers are planned to improve open-loop modeling of maneuvers and to reduce execution errors. Uncalibrated execution errors are indicated. Such errors could be reduced by 50% or more over the course of the mission. Special calibrations are of particular importance for the return leg of the mission, since the sample canister must be returned to a specific location within the Utah Test and Training Range (UTTR) for mid-air retrieval. An entry angle tolerance of no less than +/- 0.08 deg. is required to achieve this objective. Biasing of the final return maneuvers coupled with a specific maneuver mode to use a series of well-characterized spin changes to effect these maneuvers is part of the current Genesis baseline mission plan. Another important objective of calibrations is to better characterize precession maneuvers. Such maneuvers are part of most propulsive maneuvers, but are also required periodically to maintain sun-pointing for power or daily during solar-wind pointing during collection periods. Although relatively small, such maneuvers will have a significant cumulative impact on orbit determination, particularly in the halo portion of the mission. The current mission design also calls for three stationkeeping maneuvers during each halo orbit of approximately six months duration. These stationkeeping maneuvers may be sufficiently small that single or double 360 deg. precession changes may be required. Because there are no accelerometers on board the spacecraft, calibration can only be performed with the aid of ground-based radiometric tracking. To establish a high degree of accuracy in characterizing the magnitude of burns, the spacecraft spin axis should be along the line of sight to the Earth, providing Doppler measurements with <1 mm/sec accuracy in S-Band. Emission constraints allow such alignment only during certain portions of the mission when the Earth-spacecraft-sun geometry is favorable. The impact of precessions, or burns at times when geometry is not favorable, can be assessed by reconstruction of the spacecraft trajectory using tracking arcs of several days before and after the event.

Williams, Kenneth E.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Analysis of the Spaceflight Effects on Growth and Development of Super Dwarf Wheat Grown on the Space Station Mir

The hypothesis being tested is that Super Dwarf wheat, Triticum aestivum L., plants in the Svet Greenhouse onboard the Russian Space Station Mir will complete a life cycle in spaceflight, providing that the environmental conditions necessary for adequate growth on Earth are supplied. Twenty six seeds of wheat were planted in each of 2 rows of 2 root compartments for a total of 104 seeds in Svet. Germination rate at 7 d was 56 and 73% on Mir and 75 and 90% in ground-based controls. Plants were grown throughout the whole cycle of ontogenesis (123 d) with samples gathered at different times to validate the morphological and reproductive stages of the plants. Young plants showed vigorous early seedling growth, with large biomass production, including the formation of 280 floral spikes. Upon return to Earth, comparative analyses showed that the number of tillers and flowers per spikelet were 63.2% and 40% greater, respectively, in Mir-grown plants than in the controls. By contrast, the stem length (52.4%), spike mass (49.2%) and length (23.1%), awn length (75.7%), number of spikelets per spike (42.8%) and number of seeds per spike (100% sterile) from Mir-grown plants were substantially less than the controls. Distribution of moisture and roots throughout the substrate was very good. All florets on Mir-grown spikes ceased development at the same stage of ontogeny. Lack of caryopses formation was attributed to male sterility occurring at different stages of staminal development. Anthers failed to dehisce and pollen grains were smaller and shriveled compared to the controls, suggesting a chronic stress had occurred in the Svet growth chamber. Recent ground-based studies indicated that ethylene, which was measured at 0.3 to 1.8 mg per kilogram in the Mir, almost certainly could have induced male sterility in the wheat plants grown on the Mir.

Levinskikh, M. A.↗