Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Computing, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

A tutorial on the micro-trench technique for incident ion angle, material erosion, and impurity deposition measurements at plasma-facing surfaces

The micro-trench method is a new technique to measure polar and azimuthal incident ion angles, material erosion, and impurity deposition at plasma-facing surfaces, and has been applied in the DIII-D divertor. This article gives a tutorial of the micro-trench technique consisting of six steps: (1) micro-trench fabrication, (2) pre-exposure measurement of the fabricated micro-trench geometry, (3) tracer material deposition, (4) plasma exposure, (5) post-exposure observation of the tracer material, and (6) post-exposure measurement of the micro-trench geometry. Two criteria need to be satisfied to apply the micro-trench method successfully: (i) uniform impurity deposition on the micro-trench floor, and (ii) erosion dominated by the physical sputtering induced by the impinging ions. Furthermore, when those two criteria are satisfied, post-exposure analysis of the impurity deposition patterns on the micro-trench floor may be used to determine the polar and azimuthal incident ion directions (mean values of the ion angle directions), erosion rate, and impurity deposition rate during plasma exposure without computational interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling campus grids with open science grid technology

The Open Science Grid is a recognized key component of the US national cyber-infrastructure enabling scientific discovery through advanced high throughput computing. The principles and techniques that underlie the Open Science Grid can also be applied to Campus Grids since many of the requirements are the same, even if the implementation technologies differ. We find five requirements for a campus grid: trust relationships, job submission, resource independence, accounting, and data management. The Holland Computing Center's campus grid at the University of Nebraska-Lincoln was designed to fulfill the requirements of a campus grid. A bridging daemon was designed to bring non-Condor clusters into a grid managed by Condor. Condor features which make it possible to bridge Condor sites into a multi-campus grid have been exploited at the Holland Computing Center as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation

Purpose: Previously, the authors developed a dual-energy (DE) acquisition technique for a photon-counting digital breast tomosynthesis (DBT) imaging system. Low-energy (LE) and high-energy (HE) images are acquired in a single scan by covering alternate slits of a multislit prepatient collimator with Sn and Cu, respectively. A theoretical model was used to optimize the technique. In this article, an experimental validation of this technique is presented. Methods: Experiments were performed on a prototype DBT system. LE and HE projection images were acquired sequentially; either a Sn or a Cu filter was positioned in the filter holder at the exit window of the x-ray tube. Sn filters from 0.113 to 0.242 mm thick and Cu filters from 0.103 to 0.267 mm were used. The images were acquired with a W target at 49 kV. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. DE-DBT images were obtained by weighted logarithmic subtraction of the LE and HE images. Weighting factors w{sub t} that optimally cancel breast tissues with two different glandularities were assessed for 20-80 mm thick phantoms with 0%, 50%, and 100% glandularity. The mean and standard deviation in the per-pixel signal intensity (SI) were calculated in the DBT images. These data were used to calculate signal-difference-to-noise ratios (SDNRs) between iodine enhanced and nonenhanced polymethyl methacrylate backgrounds. To illustrate the feasibility of the technique, DE-DBT images of a structured phantom containing iodine disks were assessed. The experimental results were compared against the values obtained from a theoretical model of the imaging system. Results: The average difference between theoretical and experimental w{sub t} was found to range from 8% to 21%. Experimental w{sub t} values increase with phantom thickness and Cu thickness, depend somewhat on Sn thickness, and vary more as a function of breast composition in thick breasts than in thin breasts. Theoretical and experimental mean and standard deviation in the per-pixel SI differ by -7% to 10% and by -3% to 4%. Theoretical and experimental SDNR values differ, on average, by 1.5%. Iodine concentrations can be predicted from SDNR; the relationship can be accurately fit to a quadratic. In the images of the structured phantom, iodine concentrations of 1 mg/cm{sup 2} and larger are discernable. Conclusions: The strong agreement between experimental and theoretical results in this article indicates that the authors' computer model is accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predicting variation in subject thermal response during transcranial magnetic resonance guided focused ultrasound surgery: Comparison in seventeen subject datasets

Purpose: In transcranial magnetic resonance-guided focused ultrasound (tcMRgFUS) treatments, the acoustic and spatial heterogeneity of the skull cause reflection, absorption, and scattering of the acoustic beams. These effects depend on skull-specific parameters and can lead to patient-specific thermal responses to the same transducer power. In this work, the authors develop a simulation tool to help predict these different experimental responses using 3D heterogeneous tissue models based on the subject CT images. The authors then validate and compare the predicted skull efficiencies to an experimental metric based on the subject thermal responses during tcMRgFUS treatments in a dataset of seventeen human subjects. Methods: Seventeen human head CT scans were used to create tissue acoustic models, simulating the effects of reflection, absorption, and scattering of the acoustic beam as it propagates through a heterogeneous skull. The hybrid angular spectrum technique was used to model the acoustic beam propagation of the InSightec ExAblate 4000 head transducer for each subject, yielding maps of the specific absorption rate (SAR). The simulation assumed the transducer was geometrically focused to the thalamus of each subject, and the focal SAR at the target was used as a measure of the simulated skull efficiency. Experimental skull efficiency for each subject was calculated using the thermal temperature maps from the tcMRgFUS treatments. Axial temperature images (with no artifacts) were reconstructed with a single baseline, corrected using a referenceless algorithm. The experimental skull efficiency was calculated by dividing the reconstructed temperature rise 8.8 s after sonication by the applied acoustic power. Results: The simulated skull efficiency using individual-specific heterogeneous models predicts well (R{sup 2} = 0.84) the experimental energy efficiency. Conclusions: This paper presents a simulation model to predict the variation in thermal responses measured in clinical ctMRGFYS treatments while being computationally feasible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SCALE Continuous-Energy Eigenvalue Sensitivity Coefficient Calculations

Sensitivity coefficients describe the fractional change in a system response that is induced by changes to system parameters and nuclear data. The Tools for Sensitivity and UNcertainty Analysis Methodology Implementation (TSUNAMI) code within the SCALE code system makes use of eigenvalue sensitivity coefficients for an extensive number of criticality safety applications, including quantifying the data-induced uncertainty in the eigenvalue of critical systems, assessing the neutronic similarity between different critical systems, and guiding nuclear data adjustment studies. The need to model geometrically complex systems with improved fidelity and the desire to extend TSUNAMI analysis to advanced applications has motivated the development of a methodology for calculating sensitivity coefficients in continuous-energy (CE) Monte Carlo applications. The Contributon-Linked eigenvalue sensitivity/Uncertainty estimation via Tracklength importance CHaracterization (CLUTCH) and Iterated Fission Probability (IFP) eigenvalue sensitivity methods were recently implemented in the CE-KENO framework of the SCALE code system to enable TSUNAMI-3D to perform eigenvalue sensitivity calculations using continuous-energy Monte Carlo methods. This work provides a detailed description of the theory behind the CLUTCH method and describes in detail its implementation. This work explores the improvements in eigenvalue sensitivity coefficient accuracy that can be gained through the use of continuous-energy sensitivity methods and also compares several sensitivity methods in terms of computational efficiency and memory requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of A Self Biased High Efficiency Solid-State Neutron Detector for MPACT Applications

Neutron detection is an important aspect of materials protection, accounting, and control for transmutation (MPACT). Currently He-3 filled thermal neutron detectors are utilized in many applications; these detectors require high-voltage bias for operation, which complicates the system when multiple detectors are used. In addition, due to recent increase in homeland security activity and the nuclear renaissance, there is a shortage of He-3, and these detectors become more expensive. Instead, cheap solid-state detectors that can be mass produced like any other computer chips will be developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Polyhedral Transformation Framework for Compiler Optimization (Final Project Report)

The project developed the polyhedral compiler transformation module PolyOpt/Fortran in the ROSE compiler framework. PolyOpt/Fortran performs automated transformation of affine loop nests within FORTRAN programs for enhanced data locality and parallel execution. A FORTAN version of the Polybench library was also developed by the project. A third development was a dynamic analysis approach to gauge vectorization potential within loops of programs; software (DDVec) for automated instrumentation and dynamic analysis of programs was developed.

97 MATHEMATICS AND COMPUTING↗

FuncQEE CT Scans - Set 11

A collection of x-ray computed tomography scans of specimens from the Museum of Southwestern Biology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumented SSH

NERSC recently undertook a project to access and analyze Secure Shell (SSH) related data. This includes authentication data such as user names and key fingerprints, interactive session data such as keystrokes and responses, and information about noninteractive sessions such as commands executed and files transferred. Historically, this data has been inaccessible with traditional network monitoring techniques, but with a modification to the SSH daemon, this data can be passed directly to intrusion detection systems for analysis. The instrumented version of SSH is now running on all NERSC production systems. This paper describes the project, details about how SSH was instrumented, and the initial results of putting this in production.

97 MATHEMATICS AND COMPUTING↗

Test facility for fission chamber assemblies - 239

The Institution -Project Center ITER- with participation of the National Research Nuclear University MEPhI are developing the neutron diagnostics -Divertor Neutron Flux Monitor- (DNFM) for the International Thermonuclear Experimental Reactor (ITER). This diagnostics shall ensure measurement of the total neutron yield and ITER fusion power. Assemblies of fission chambers (FC) with different fissile materials and sensitivities are planned to be used for the neutron flux measurement. Study of fission chambers characteristics and acceptance testing of the diagnostic system will be carried out at the testing facility of the neutronic laboratory of the 'TRINITI' Institute. The facility includes: compact powerful neutron generator with the power, control and monitoring system; remote handling system for FCs positioning and movement; novel three channels data acquisition and processing system. Each acquisition channel contains some measuring circuits with signal processing. This set of circuits provides neutron flux measurement in the range of at least 10 decades for each single FC. Data acquisition and processing system features are: signal digitizing with sample rate up to 125 MHz; real time data processing with computation and data update cycle from 0.1 ms. This paper examines the structure, composition and specification of the test facility. Application software, hardware solutions and the results of fission chambers prototypes tests are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large Matched-Index-of-Refraction (MIR) Flow Systems for International Collaboration In Fluid Mechanics

In recent international collaboration, INL and Uni. Erlangen have developed large MIR flow systems which can be ideal for joint graduate student education and research. The benefit of the MIR technique is that it permits optical measurements to determine flow characteristics in complex passages and around objects to be obtained without locating a disturbing transducer in the flow field and without distortion of the optical paths. The MIR technique is not new itself; others employed it earlier. The innovation of these MIR systems is their large size relative to previous experiments, yielding improved spatial and temporal resolution. This report will discuss the benefits of the technique, characteristics of the systems and some examples of their applications to complex situations. Typically their experiments have provided new fundamental understanding plus benchmark data for assessment and possible validation of computational thermal fluid dynamic codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a Data Platform for High-Temperature Gas-cooled Reactor (HTGR) Nuclear Energy University Program (NEUP) Thermal-Fluid Experiments

Since the U.S. Department of Energy (DOE)’s Office of Nuclear Energy (NE) initiated the Nuclear Energy University Program (NEUP) in 2009, a total of 30 NEUP projects focused on High-Temperature Gas-cooled Reactor (HTGR) thermal-fluid experiments were funded up to fiscal year (FY) 2021. This represents a total DOE investment of approximately $23M over the 12-year period, covering thermal fluid phenomena important to both pebble bed and prismatic HTGR designs. The NEUP projects have produced a large amount of high-quality experimental and computational data that were published in final project reports, journal articles, dissertations, and conference proceedings, but in most cases the actual data sets and supporting information such as facility and instrumentation descriptions were not publicly disseminated to the HTGR community. To the authors’ best knowledge, a data platform that organizes and summarizes these NEUP-funded projects for HTGR research does not currently exist. To improve access to this HTGR validation data and optimize the return on the significant investment made by DOE, the Advanced Reactor Technologies (ART) Gas-Cooled Reactor (GCR) program started a survey of completed and ongoing HTGR NEUP projects with the aim of developing a public-access data platform that can be used to retrieve computational fluid dynamics (CFD) and system code validation data and guide future NEUP investments. This paper summarizes the status of the current ART-GCR database, provides an overview of the NEUP-funded HTGR-related research projects from FY2009 to FY2021 and identify validation knowledge gaps still existing in HTGR thermal-fluid research.

42 ENGINEERING↗

The 40m General Purpose Small-Angle Neutron Scattering Instrument at Oak Ridge National Laboratory

A high-flux, 40m long small-angle neutron scattering (SANS) instrument has been constructed at Oak Ridge National Laboratory (ORNL). The facility utilizes a mechanical velocity selector, pinhole collimation and a high count-rate (> 105 Hz), large-area (1m2) two-dimensional position-sensitive detector. The incident wavelength (λ), resolution (Δλ/λ), incident collimation and sample-detector distance are independently variable under computer control. The detector can translate 45cm off axis to increase the overall Q-range (< 0.001 < Q = 4πλ-1sin θ < 1 Å-1), where 2θ is the angle of scatter. The design and characteristics of this instrument are described along with examples of scattering data to illustrate the performance.

biology↗

How to Find Valid Parameters for the Modelling of H{sup -} and D{sup -} Ion Extraction with nIGUN(c)

A dedicated interactive computer program nSHEATH has been written in order to facilitate the exploration of self-consistent solutions in the (at least) 9-D parameter space for the inverted plasma sheath. In the transition from the quasi-neutral plasma to the unneutralised acceleration space of ion sources 3 major failures can occur, if the parameters are not correctly chosen:.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inside marginal adaptation of crowns by X-ray micro-computed tomography

The objective of this work was to access dental arcade by using X-ray micro-computed tomography. For this purpose high resolution system was used and three groups were studied: Zirkonzahn CAD-CAM system, IPS e.max Press, and metal ceramic. The three systems assessed in this study showed results of marginal and discrepancy gaps clinically accepted. The great result of 2D and 3D evaluations showed that the used technique is a powerful method to investigate quantitative characteristics of dental arcade. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Roundtable Report: Terahertz and 6G Wireless Communications in Science and Extreme Environments

The main objective of the roundtable is to bring together computer scientists and wireless communications experts from industry, academia, and government to explore the electromagnetic spectrum in the Terahertz (THz) bands for ultra-high-speed short-distance wireless communications in extreme environments. This new generation of THz wireless communications is the key to future machine-to-machine communications critical for the mass deployment of an intelligent Internet of Things (IoT). The roundtable discussion explores THz and 6G wireless technologies along with Visible Light Communications (VLC), intelligent reflection surfaces, free-space quantum and optical communications, and nano communications. The roundtable considers the suitability of these technologies for extreme environments from the nanoscale to the mesoscale for the following: scientific facilities and associated instruments, as well as industry, and manufacturing. Such use cases are not traditionally the primary customer of commercial wireless networks which are focused on personal broadband voice and data communications. Finally, the discussion identifies high-level opportunities and challenges for leveraging THz and 6G wireless communications and related Artificial Intelligence (AI) that can catalyze the advancement of the development of hyperconnected smart scientific instruments and facilities.

97 MATHEMATICS AND COMPUTING↗