Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Commercial Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

The Hydrofluorocarbon Phasedown and Commercial Space Conditioning: A Guide to the Transition

You may be aware of the hydrofluorocarbon (HFC) phasedown, but the details and its impact on your operations may still be unclear. Or perhaps this is the first you're hearing about the phasedown. In either case, this guide provides information to aid conversations with facility managers and engineers and provides an explanation of how the phasedown affects equipment in commercial buildings. It also includes actions you and your organization can take now to properly plan and prepare.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Decarbonization of Liquid Heating Fuels

Annually, residential and commercial buildings use about 5 billion gallons (18.9 billion liters) of distillate fuel for space and water heating. There is considerable interest in decarbonizing these markets through a combination of heat pumps and a future, carbon-free grid. An alternate approach that offers rapid and cost effective decarbonization involves substitution of low-carbon biofuels for fossil fuels within this market. Heating fuel marketers in North America and Europe are aggressively moving to achieve market penetration of biofuels. Processes for this include fuel specification standards, development of manufacturer-approved burners and all system components, development of standards for equipment listing, installation code changes, and generation of performance data. There has been considerable progress in these areas and each of these are reviewed in this paper. Currently, the most important biofuel for this market is biodiesel with a U.S. production capacity of 2.4 billion gallons (9.1 billion liters) and approximately a 75% reduction in GHG emissions. The biodiesel industry has stated a vision for dramatic increases in biodiesel production over the next decades. Fuel and equipment standards are in place to enable use of biodiesel blends to 20% and this blend is now widely used. Standard changes to extend this to as high as 100% biodiesel are nearing completion. Several states have implemented requirements for minimum levels of biodiesel in heating oil with these levels increasing over time.

09 BIOMASS FUELS↗

Brick Schema Standardized Plug Load Control Strategies for Load Reduction: Preprint

Plug loads comprise a significant percentage of commercial building energy consumption. Applying intelligent controls to turn off plug loads when unused can provide dynamic load reduction and flexibility, which are key traits of grid-interactive efficient buildings. This capability is important for equitable decarbonization as it can enable disadvantaged communities to electrify buildings without costly upgrades to electrical infrastructure. In this work, we present the effectiveness of various control strategies along with the operational lessons that informed their design. During a three-year period, we operated over 600 smart outlets in 12 university office buildings. The attached plug loads consisted primarily of printers, TVs, water dispensers, and copiers. After recording baseline power measurements for one year, we designed plug load control (PLC) strategies for each plug load type, use, and for different risk tolerance levels because PLC can potentially be disruptive to daily work. We used the Brick Schema to facilitate the management of plug load locations and other metadata. For advanced controls, we integrated the smart plugs with heating, ventilation, and air conditioning (HVAC) systems through the campus building automation system. We found static schedules to be the least disruptive and most predictable for occupants, resulting in 38% and 66% energy savings in two studies. For printers, print server-triggered PLC produced 86% savings, the highest of all strategies with minimal occupant impact. Scheduling of water dispensers and digital signage TVs produced 49% and 70% savings respectively with opportunities to improve performance with the use of HVAC occupancy data.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Frozen Freedom: Unleashing Grocery Store Demand Flexibility: Preprint

Grocery stores consumed approximately 3% of total electricity used by commercial buildings in the U.S. in 2018 (EIA 2018), representing a unique end-use load profile characterized by the critical use of refrigerated display cases. Exploring demand response (DR) scenarios in grocery stores presents an opportunity to enhance the efficiency and sustainability of surrounding communities. In addition, recent studies demonstrate that implementing control algorithms considering demand flexibility strategies can lead to load and peak reductions in standalone refrigerated display cases. Because small business grocery stores operate on thin margins, the energy bill cost savings DR might provide could make a positive difference toward continued operations. Still, uncertainty remains about the extent of demand flexibility potential controls could provide when coupling refrigeration with whole building operation. To enhance economic viability and grid stability, it is essential to quantify the load flexibility capability of grocery stores. Advanced controls can optimize energy consumption by responding to load shedding, shifting, and DR events, as well as daily Time-of-Use (TOU) rates without compromising food safety. Using both quantitative data and interviews with community-based organizations, we developed a full-size store model and two small store models with controlled refrigerated cases, HVAC, and lighting systems based on actual grocery store properties. Through simulations, we have assessed load flexibility strategies with varied DR events. The results highlight potential for energy and peak reduction with advanced or basic controls. However, interviews and data indicate that more support is needed to make DR strategies consistently accessible to small grocery stores.

demand flexibility↗

Categorizing Plug Load Solutions by Ease of Implementation

Plug loads account for a growing share of U.S. commercial building electricity use, projected to rise from 16% today to 21% by 2050. Managing these loads presents a substantial opportunity for reducing energy costs while providing additional operational benefits, such as improved asset management and occupant comfort. Despite their potential, plug loads are numerous, diverse, and highly occupant-dependent, making control challenging. This publication organizes plug load control strategies by level of effort, offering building owners and operators a staged approach to implement interventions ranging from smart outlets and automatic receptacle controls to behavioral strategies. By following these actionable steps, building stakeholders can reduce energy consumption, lower utility bills, and realize broader operational advantages.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A novel probabilistic regression model for electrical peak demand estimate of commercial and manufacturing buildings

Due to the high cost of electricity in commercial and industrial sectors, demand forecast models have gained increasing attention. However, there are two unresolved issues: (1) Models are not adaptable when exposed to previously unknown data (2) The value of regression methods vs. state-of-the-art machine learning models has not been made apparent before. This study’s goal is to develop probabilistic demand estimation models. Herein, we propose a probabilistic Bayesian regression framework that can not only estimate future demands with high accuracy but also be updated once new information is available. By applying the proposed algorithm to two real-world case studies (commercial and manufacturing), we show a 40.3% and 30.8% improvement in terms of mean absolute error for the two cases. Moreover, the proposed technique outperforms powerful machine learning approaches, including support vector machine by 10.39%, random forest by 6.17%, and multilayer perceptron by 9.14% in terms of mean absolute percentage error.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2020 Leadership Agenda for Existing Commercial and Multifamily Buildings

Leadership by state and local governments is critical to unlock national energy efficiency opportunities and deliver the benefits of efficiency to all Americans. But related to building energy efficiency, what will it mean to be a public sector leader over the next several years? What are the energy efficiency solutions that cities, counties, and states are implementing today that will make their communities more affordable, livable, healthy, and economically competitive? The SEE Action Network 2020 Leadership Agenda for Existing Commercial and Multifamily Buildings establishes a benchmark for state and local government leadership on improving the energy efficiency of buildings and seeks two-way collaboration among state, local, and federal officials. It defines a suite of innovative, yet practical policies and programs for policymakers to consider implementing by 2020, focusing on six important areas.

99 GENERAL AND MISCELLANEOUS↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

Power over Ethernet (PoE) technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras. They are systems that are familiar to and managed by on-site IT staff. As low voltage DC-power capabilities have increased with the advancement of IT network switches within offices, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. The connection of PoE devices to network switches offers the opportunity for energy monitoring and management to be performed through IT network management software. Data and results from technology validations of PoE equipment remain very limited. This lack of information hinders expansion of PoE as an energy management strategy as its benefits and challenges have been insufficiently quantified in real-world scenarios. This final report presents the findings of a DOE/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at six sites: two offices, three schools, and a hotel. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where not typically available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FY20 Third Milestone Report for Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Buildings

This report summarizes the developments of an integrated simulation program for enabling simulation, auto-sizing, and optimization of geothermal heat pump systems. This work fulfills the following FY20 third milestone for WBS 2.5.5.3: Advanced Techno-Economic Modeling for Geothermal Heat Pump Applications in Residential, Commercial, and Industry Building.

15 GEOTHERMAL ENERGY↗

Introduction to ComStock

This presentation is an introduction to ComStock and the datasets it produces. The goal of this work is to help cities, states, utilities, and other stakeholders have information and resources needed to make informed decisions about their building stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial Expert-System-Building Software Tools

Report evaluates commercially-available expert-system-building tools in terms of structures, representations of knowledge, inference mechanisms, interfaces with developers and end users, and capabilities of performing such functions as diagnosis and design. Software tools commercialized derivatives of artificial-intelligence systems developed by researchers at universities and research organizations. Reducing time to develop expert system by order of magnitude compared to that required with such traditional artificial development languages as LISP. Table lists 20 such tools, rating attributes as strong, fair, programmable by user, or having no capability in various criteria.

Gevarter, William B.↗

Calculating Impacts of Energy Standards on Energy Demand in U.S. Buildings under Uncertainty with an Integrated Assessment Model: Technical Background Data

This report presents data and assumptions employed in an application of PNNL’s Global Change Assessment Model with a newly-developed Monte Carlo analysis capability. The model is used to analyze the impacts of more aggressive U.S. residential and commercial building-energy codes and equipment standards on energy consumption and energy service costs at the state level, explicitly recognizing uncertainty in technology effectiveness and cost, socioeconomics, presence or absence of carbon prices, and climate impacts on energy demand. The report provides a summary of how residential and commercial buildings are modeled, together with assumptions made for the distributions of state–level population, Gross Domestic Product (GDP) per worker, efficiency and cost of residential and commercial energy equipment by end use, and efficiency and cost of residential and commercial building shells. The cost and performance of equipment and of building shells are reported separately for current building and equipment efficiency standards and for more aggressive standards. The report also details assumptions concerning future improvements brought about by projected trends in technology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The nature and evaluation of commercial expert system building tools

This memorandum reviews the factors that constitute an Expert System Building Tool (ESBT) and evaluates current tools in terms of these factors. Evaluation of these tools is based on their structure and their alternative forms of knowledge representation, inference mechanisms and developer/end-user interfaces. Next, functional capabilities, such as diagnosis and design, are related to alternative forms of mechanization. The characteristics and capabilities of existing commercial tools are then reviewed in terms of these criteria.

Gevarter, William B.↗

The nature and evaluation of commercial expert system building tools, revision 1

This memorandum reviews the factors that constitute an Expert System Building Tool (ESBT) and evaluates current tools in terms of these factors. Evaluation of these tools is based on their structure and their alternative forms of knowledge representation, inference mechanisms and developer end-user interfaces. Next, functional capabilities, such as diagnosis and design, are related to alternative forms of mechanization. The characteristics and capabilities of existing commercial tools are then reviewed in terms of these criteria.

Gevarter, William B.↗

The Demonstration of Power over Ethernet (PoE) Technologies in Commercial and Institutional Buildings

PoE technologies are currently ubiquitous in offices in the form of phones, access points, and IP security cameras and managed by on-site IT staff. As low voltage DC-power capabilities have increased with network switches, PoE devices are now being integrated across additional building systems, including lighting, computers, and HVAC controls. Since PoE devices are connected to network switches, energy monitoring and management can be performed through the IT network management software. Data and results from technology validations are still very limited for PoE equipment. This lack of information hinders higher adoption as its benefits and challenges have been insufficiently quantified in real-world scenarios. The use of IT network switches to power and control lighting, plug loads, and HVAC were demonstrated at a variety of sites including offices, schools, and a hotel. This paper presents the findings of a three-year DOE-/State of Minnesota-funded project that demonstrated and assessed the energy and non-energy benefits of Power over Ethernet (PoE) technologies at four commercial/institutional sites. The goals of the demonstrations were to: (1) assess the receptiveness of commercial and institutional markets to these new technologies, (2) demonstrate the feasibility of PoE technologies within standard design/construction practices and commercial codes, (3) assess the energy and cost savings opportunities of these technologies, (4) provide energy management opportunities where they typically are not available, and (5) formulate approaches to spur adoption of these technologies in the marketplace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m 2 (2100ft 2 ) residential building and a 4,982m 2 (53,628ft 2 ) three-story commercial office building, and it ran 10-15 year simulations. The integrated GHP model and its Simulink platform provided residential data, ranging from seconds to years, and commercial office building data, ranging from minutes to years. A cooling tower model was coupled to the base case integrated GHP model for the residential building and the resulting HGHP system provided a cost-effective solution for the Austin, TX location. Simulations for both the residential and commercial building models were run with varying degrees of SHR (device/system not identified) and the results were found to significantly decrease installation costs, increase heat pump efficiency (lower entering water temperature), and prolong the lifetime of the borehole field. Lifetime cycle costs were estimated from the simulation results. Sensitivity studies on system operating performance and lifetime costs were performed on design parameters, such as construction materials, borehole length, borehole configuration and spacing, grout conductivity, and effects of SHR. While some of the results are intuitive, these studies provided quantitative estimates of improved performance and cost. One of the most important results of this sensitivity study is that overall system performance is very sensitive to these design parameters and that modeling and simulation are essential tools to design cost-effective systems.

15 GEOTHERMAL ENERGY↗

A comparative energy analysis of three electrochromic glazing technologies in commercial and residential buildings

Here, we present a simulation study of three dynamic electrochromic window glazings, including a novel glazing capable of independently modulating its optical properties in both the visible and near-infrared spectrums. This capability allows this so-called “dual-band” technology to actively manage the solar heat and visible light transmitted into a building's interior, and creates the potential for heating, cooling, and lighting savings vis-à-vis competing window technologies. In this study EnergyPlus is used to simulate annual energy performance of the dual-band electrochromic (DBEC) glazing in three building types and 16 U.S. climate regions. The savings potential of DBEC windows are presented relative to a conventional electrochromic glazing; a visibly transparent, near-infrared switching electrochromic glazings; and several static alternatives, including ASHRAE 90-2010 standard compliant windows. Results indicate that the DBEC glazings are capable of outperforming alternatives in a diverse set of locations and building types, including both heating and cooling-dominated regions. Relative to code-compliant static windows, the DBEC is capable of achieving annual primary energy savings between 6 and 30 kW h/ft 2 of window area from reduced heating, cooling, and lighting demand. Relative to other advanced glazings, the savings are significantly lower, ranging from 0 to 1.2 kW h/ft 2 . Regional DBEC energy cost savings versus high performance static windows are presented to identify early potential market entries based on energy savings. Lastly, the impacts of widespread deployment of high-efficiency LED lighting on DBEC energy savings potentials are also presented.

14 SOLAR ENERGY↗