Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Coils”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Reassembly and Test of High-Field Nb3Sn Dipole Demonstrator MDPCT1

In the framework of the U.S. Magnet Development Program (MDP), Fermilab has developed and tested a high-field Nb$_3$Sn dipole demonstrator MDPCT1 for a post-LHC Hadron Collider. The magnet was first assembled with a lower coil pre-load to minimize the risk of coil damage during assembly and test. In the first test the magnet reached its test goal producing a world record field of 14.1 T at 4.5 K. Next the magnet was reassembled with nominal pre-load to achieve its design field limit of 15 T. This paper describes the details of MDPCT1 inspection, design modifications and reassembly. The magnet quench performance, including training, ramp rate and temperature dependences in the temperature range of 1.9-4.5 K, is presented and discussed.

43 PARTICLE ACCELERATORS↗

Radio-Frequency Rapid Thermal Processing Enabling Spatial Phase Transformation and Nanocrystallization of Soft Magnetic Amorphous Alloys

Thermal processing of soft magnetic amorphous and nanocrystalline alloys is explored under the influence of radio-frequency induction-heating techniques. Direct induction-heating concepts based on longitudinal and transverse flux heating are examined and the details of electromagnetic fields interaction with metallic strips are discussed by analytical calculations as well as finite element analysis. Initial experimental results confirming spatial control of phase transformations and nanocrystallization within a single strip of Finemet Fe-based amorphous ribbons are reported. Here, the degree to which primary and secondary crystallization temperature are achieved depends on the spacing between the ribbon relative to the induction coil as well as the coil design and configuration. For transverse coil configurations, the local temperature and therefore microstructural evolution is different across the lateral dimension of processed ribbons, with reduced gap sizes producing enhanced peak temperatures and larger temperature distributions with greater spatial variation in microstructure. In addition, indirect susceptor-based induction heating under tension is performed and the impact of microstructure is demonstrated. Herein, potential for exploiting spatially optimized phase transformations is illustrated through electromagnetic field–assisted processing in a scalable manufacturing process with amorphous and nanocrystalline soft magnetic alloys.

36 MATERIALS SCIENCE↗

Unraveling the Molecular Origin of Prey-Wrapping Spider Silk's Unique Mechanical Properties and Assembly Process Using NMR

Prey wrapping spider silk's unique mechanical properties are investigated confirming the silk's high degree of extensibility and superior toughness compared to other types of spider silk. For the first time, the pre-spinning dope phase is studied in isotope-enriched intact aciniform (AC) silk glands using solution NMR that reveals a combination of α-helical domains linked by disordered random coil chains consistent with previously proposed “beads-on-a-string” models. The model is further refined through the AlphaFold2 protein structure prediction tool. Finally, extensive magic angle spinning (MAS) solid-state (SS) NMR data for isotopically-enriched fibers is used to refine the structural model for AC silk from two species, A. aurantia and A. argentata. The SSNMR data shows that the AC silk fibers are highly α-helical, coiled-coil in structure but, also exhibit significant β-sheet components that can be traced back to the Gly-rich disordered linker regions in the pre-spinning dope phase that are converted to β-sheet structures during fiber formation. This combination of mechanical and structural characterization enhances the understanding of AC silk's liquid-to-solid transition and structure-mechanics relationship. In conclusion, these prey wrap silk results and models will provide the basis for the design of biomimetic materials inspired by the AC spider silk system.

36 MATERIALS SCIENCE↗

Crural Artery Traumatic Injuries: Treatment with Embolization

The purpose of this paper is to report our experience with the endovascular treatment of crural arterial injuries using transcatheter and direct embolization techniques. A total of eight consecutive patients have been treated during a 7-year period. Six males and two females, mean age 32 years (range, 15-56 years), presented with penetrating trauma to the lower extremities. Mechanisms of injuries were stab wounds in six patients, gun shot wound in one patient, and iatrogenic injury in one patient. Five patients presented with acute trauma, while three patients presented with delayed injuries. Crural arterial injuries encountered included pseudoaneurysms with arteriovenous fistulas (n = 6), pseudoaneurysms with vessel transections (n = 2), and pseudoaneurysm (n = 1). Proximal and distal embolization with coils was used in three cases, proximal embolization with coils in three cases, percutaneous thrombin injection in one case, and liquid n-butyl cyanoacrylate in one case. Complete exclusion of the lesions was accomplished by sacrifice of one crural vessel in seven cases and of two crural vessels in one case. Two cases of delayed injuries required combined coil and liquid embolization techniques for lesion exclusion. A minor complication (groin hematoma) occurred in one patient, no distal ischemia was seen, and no amputations were required. Mean follow-up was 61 days (range, 1-180 days). One pseudoaneurysm treated with thrombin injection recurred and required surgical excision. We conclude that transcatheter embolization alone or in combination with different endovascular techniques is useful in the treatment of traumatic crural vessel injuries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Internal Iliac Artery: Cost-Effectiveness of Two Different Techniques

The purpose of this study was to compare the cost-effectiveness of coils versus the Amplatzer Vascular Plug (AVP) for occlusion of the internal iliac artery (IAA). Between 2002 and January 2006, 13 patients (mean age 73 {+-} 13 years) were referred for stent-grafting of abdominal aortic aneurysm (n = 6); type I distal endoleak (n = 3), isolated iliac aneurysm (n = 3), or rupture of a common iliac aneurysm (n = 1). In all patients, extension of the stent-graft was needed because the distal neck was absent. Two different techniques were used to occlude the IIA: AVP in seven patients (group A) and coil embolization in six patients (group C). Immediate results and direct material costs were assessed retrospectively. Immediate success was achieved in all patients, and simultaneous stent-grafting was successfully performed in two of six patients in group C versus five of seven patients in group A. In all group A patients, a single AVP was sufficient to achieve occlusion of the IIA, accounting for a mean cost of 485 Euro , whereas in group C patients, an average of 7 {+-} 3 coils were used, accounting for a mean cost of 1,745 Euro . Mean average cost savings using the AVP was 1,239 Euro . When IIA occlusion is needed, the AVP allows a single-step procedure at significant cost savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stroke Secondary to Aseptic Meningitis After Endovascular Treatment of a Giant Aneurysm with Parent Artery Occlusion

Aseptic meningitis related to hydrogel-coated coils is a known complication, but it is extremely rare after platinum bare coil aseptic meningitis. Here we report the development of aseptic meningitis causing brain stem and cerebellar infarct in a patient with a giant aneurysm treated with bare platinum coils. We conclude that aneurysm size is an important factor affecting the occurrence of aseptic meningitis associated with stroke.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pure Ethiodized Oil-based Transcatheter Ablative Therapy in Normal Rabbit Kidneys and Kidneys Inoculated with VX-2 Carcinoma

Purpose: To evaluate the efficacy of ablation with selective arterial injection of pure ethiodized oil followed by arterial occlusion with 9:1 ethanol-Ethiodol mixture (EEM) and coil placement in normal rabbit kidneys and kidneys inoculated with VX-2 carcinoma. Materials and Methods: All experiments were conducted with Animal Care and Use Committee approval. In six rabbits (group 1), one kidney was embolized with pure Ethiodol until capillary stasis, followed by injection of 9:1 EEM until arterial stasis and then coil placement into the main renal artery. In 12 other rabbits, one kidney was inoculated with VX-2 tumor. Ethiodol and EEM embolization and coil placement followed 7 days later (group 2, n = 6) or 11-14 days later (group 3, n = 6). Kidneys were evaluated (angiography, computed tomography, macro- and microscopy) 7 days after treatment. Results: Capillary stasis was achieved in groups 1, 2, and 3 with (mean {+-} standard deviation) 0.47 {+-} 0.03, 0.53 {+-} 0.02, and 0.56 {+-} 0.04 ml of pure Ethiodol, followed by 0.47 {+-} 0.05, 0.42 {+-} 0.03, and 0.38 {+-} 0.04 ml of EEM, respectively, which caused complete arterial occlusion in 17 of 18 kidneys. In group 1, all but one kidney showed at least 95% generalized coagulative necrosis. In group 2, all six kidneys exhibited 100% coagulative necrosis, with no viable tumor present. In group 3, 100% coagulative necrosis was present in all kidneys, with a small viable tumor in one. Conclusion: In the rabbit, selective arterial injection of pure Ethiodol can cause complete renal parenchyma and tumor ablation when it is followed by prompt, contiguous, and permanent occlusion of the arterial compartment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Iatrogenic Native Renal Arterial Pseudoaneurysms

Purpose: Our purpose was to evaluate iatrogenic renal pseudoaneurysms, endovascular treatment, and outcomes. Methods: This retrospective study (2003-2011) reported the technical and clinical outcomes of endovascular therapy for renal pseudoaneurysms in eight patients (mean age, 46 (range 24-68) years). Renal parenchymal loss evaluation was based on digital subtraction angiography and computed tomography. Results: We identified eight iatrogenic renal pseudoaneurysm patients with symptoms of hematuria, pain, and hematoma after renal biopsy (n = 3), surgery (n = 3), percutaneous nephrolithotomy (n = 1), and endoscopic shock-wave lithotripsy (n = 1). In six patients, the pseudoaneurysms were small-sized (<20 mm) and peripherally located and were treated solely with coil embolization (n = 5). In one patient, coil embolization was preceded by embolization with 500-700 micron embospheres to control active bleeding. The remaining two patients had large-sized ({>=}50 mm), centrally located renal pseudoaneurysms treated with thrombin {+-} coils. Technical success with immediate bleeding cessation was achieved in all patients. There were no procedure-related deaths or complications (mean follow-up, 23.5 (range, 1-67) months). Conclusions: Treatment of renal pseudoaneurysms using endovascular approach is a relatively safe and viable option regardless of location (central or peripheral) and size of the lesions with minimal renal parenchymal sacrifice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Broad-Neck Aneurysm Creation in a Porcine Model Using a Vascular Plug

Ruptured cerebral arterial aneurysms require prompt treatment by either surgical clipping or endovascular coiling. Training for these sophisticated endovascular procedures is essential and ideally performed in animals before their use in humans. Simulators and established animal models have shown drawbacks with respect to degree of reality, size of the animal model and aneurysm, or time and effort needed for aneurysm creation. We therefore aimed to establish a realistic and readily available aneurysm model. Five anticoagulated domestic pigs underwent endovascular intervention through right femoral access. A total of 12 broad-neck aneurysms were created in the carotid, subclavian, and renal arteries using the Amplatzer vascular plug. With dedicated vessel selection, cubic, tubular, and side-branch aneurysms could be created. Three of the 12 implanted occluders, two of them implanted over a side branch of the main vessel, did not induce complete vessel occlusion. However, all aneurysms remained free of intraluminal thrombus formation and were available for embolization training during a surveillance period of 6 h. Two aneurysms underwent successful exemplary treatment: one was stent-assisted, and one was performed with conventional endovascular coil embolization. The new porcine aneurysm model proved to be a straightforward approach that offers a wide range of training and scientific applications that might help further improve endovascular coil embolization therapy in patients with cerebral aneurysms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

N-butyl Cyanoacrylate Glue Embolization of Arterial Networks to Facilitate Hepatic Arterial Skeletonization before Radioembolization

Purpose. Avoidance of nontarget microsphere deposition via hepatoenteric anastomoses is essential to the safety of yttrium-90 radioembolization (RE). The hepatic hilar arterial network may remain partially patent after coil embolization of major arteries, resulting in persistent risk. We retrospectively reviewed cases where n-butyl cyanoacrylate (n-BCA) glue embolization was used to facilitate endovascular hepatic arterial skeletonization before RE. Methods. A total of 543 RE procedures performed between June 2004 and March 2012 were reviewed, and 10 were identified where n-BCA was used to embolize hepatoenteric anastomoses. Arterial anatomy, prior coil embolization, and technical details were recorded. Outcomes were reviewed to identify subsequent complications of n-BCA embolization or nontarget RE. Results. The rate of complete technical success was 80 % and partial success 20 %, with one nontarget embolization complication resulting in a minor change in treatment plan. No evidence of gastrointestinal or biliary ischemia or infarction was identified, and no microsphere-related gastroduodenal ulcerations or other evidence of nontarget RE were seen. Median volume of n-BCA used was <0.1 ml. Conclusion. n-BCA glue embolization is useful to eliminate hepatoenteric networks that may result in nontarget RE, especially in those that persist after coil embolization of major vessels such as the gastroduodenal and right gastric arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Fiducial Marker Placement for Image-guided Proton Therapy for Malignant Liver Tumors

PurposeThe aim of this study is to analyze the technical and clinical success rates and safety of transarterial fiducial marker placement for image-guided proton therapy for malignant liver tumors.Methods and MaterialsFifty-five patients underwent this procedure as an interventional treatment. Five patients had 2 tumors, and 4 tumors required 2 markers each, so the total number of procedures was 64. The 60 tumors consisted of 46 hepatocellular carcinomas and 14 liver metastases. Five-mm-long straight microcoils of 0.018 inches in diameter were used as fiducial markers and placed in appropriate positions for each tumor. We assessed the technical and clinical success rates of transarterial fiducial marker placement, as well as the complications associated with it. Technical success was defined as the successful delivery and placement of the fiducial coil, and clinical success was defined as the completion of proton therapy.ResultsAll 64 fiducial coils were successfully installed, so the technical success rate was 100 % (64/64). Fifty-four patients underwent proton therapy without coil migration. In one patient, proton therapy was not performed because of obstructive jaundice due to bile duct invasion by hepatocellular carcinoma. Thus, the clinical success rate was 98 % (54/55). Slight bleeding was observed in one case, but it was stopped immediately and then observed. None of the patients developed hepatic infarctions due to fiducial marker migration.ConclusionTransarterial fiducial marker placement appears to be a useful and safe procedure for proton therapy for malignant liver tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Single-Center Retrospective Follow-Up After Embolization of Pulmonary Arteriovenous Malformations Treated Over a 20-year Period: Frequency of Re-canalization with Various Embolization Materials and Clinical Outcome

Purpose: The present study is a register-based observational study of an unselected consecutive patient cohort with pulmonary arteriovenous malformations (PAVMs) from a single national hereditary hemorrhagic telangiectasia and PAVM embolization center. The aim was to investigate the frequency of re-embolizations and the clinical outcome after embolization with the use of different embolization materials further, to define which PAVM morphology and size of feeding arteries that most often were re-embolized, and to estimate the clinical outcome of the patients including those that were re-embolized. Methods: The population was included from 1996 until 2016 and was made up of a total of 136 patients with 322 PAVMs. Median follow-up was 38.3 (0.3–241 months). Results: The re-embolization rate was 9.3%. None of the PAVMs treated with detachable silicone balloons were re-embolized, while 4.5% treated with vascular plugs and 11.7% treated with coils were re-embolized (p=0.07). In total, 16/74 complex PAVMs were re-embolized compared with 14/248 simple PAVMs. In big-sized feeding arteries ≥ 6mm, 16/112 were re-embolized compared with 14/210 with smaller-sized feeding arteries. Out of the 30 re-embolized PAVMs, 23 resulted in a successful clinical outcome. Conclusions: Our results suggest that standard coils probably should not be the first choice for embolization of PAVMs, and vascular plug alone or in combination with coils might be a better primary option for embolization in these patients. Level of Evidence: Level 3A, non-randomized case controlled cohort/follow-up study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance assessment of radiant cooling system integrated with desiccant assisted DOAS with solar regeneration

The Radiant cooling system integrated with Dedicated Outdoor Air System (DOAS) is a viable substitution for conventional all air system in order to reduce primary energy consumption, as it decouples the cooling and ventilation task. In DOAS major portion of energy is consumed in cooling coil where it dehumidifies the process supply air. This study describes an alternate solution for dehumidification, with the substitution of the desiccant wheel with solar regeneration in place of a chilled water coil based dehumidifier. In this paper, simulations were carried out using EnergyPlus on a reference medium office building to investigate the contribution of solar energy towards the total energy consumption of desiccant assisted DOAS with radiant cooling system. To evaluate the system performance and energy saving potential, desiccant based DOAS is compared with cooling coil assisted DOAS integrated with Radiant cooling system. Simulations were carried out for different solar collector area to evaluate primary energy savings. Results indicate that from 7.4 % to 28.6 % energy saving (according to different collector area) can be achieved due to the solar regeneration in desiccant assisted DOAS, the impact of different solar collector area on potential of energy savings is also described.

42 ENGINEERING↗

Chameleon sequences in neurodegenerative diseases

Chameleon sequences can adopt either alpha helix sheet or a coil conformation. Defining chameleon sequences in PDB (Protein Data Bank) may yield to an insight on defining peptides and proteins responsible in neurodegeneration. In this research, we benefitted from the large PDB and performed a sequence analysis on Chameleons, where we developed an algorithm to extract peptide segments with identical sequences, but different structures. In order to find new chameleon sequences, we extracted a set of 8315 non-redundant protein sequences from the PDB with an identity less than 25%. Our data was classified to “helix to strand (HE)”, “helix to coil (HC)” and “strand to coil (CE)” alterations. We also analyzed the occurrence of singlet and doublet amino acids and the solvent accessibility in the chameleon sequences; we then sorted out the proteins with the most number of chameleon sequences and named them Chameleon Flexible Proteins (CFPs) in our dataset. Our data revealed that Gly, Val, Ile, Tyr and Phe, are the major amino acids in Chameleons. We also found that there are proteins such as Insulin Degrading Enzyme IDE and GTP-binding nuclear protein Ran (RAN) with the most number of chameleons (640 and 405 respectively). These proteins have known roles in neurodegenerative diseases. Therefore it can be inferred that other CFP's can serve as key proteins in neurodegeneration, and a study on them can shed light on curing and preventing neurodegenerative diseases.

60 APPLIED LIFE SCIENCES↗

Controlling the aqueous solubility of PNIPAM with hydrophobic molecular units

The effect of co-polymerization of thermo-sensitive polymers with hydrophilic or hydrophobic co-monomers on the LCST and the structure of proximal water remains a fundamental and challenging problem. Here, in this study, we employ all-atom molecular dynamics simulations to investigate the aqueous solubility of a thermo-sensitive polymer, poly(N-isopropylacrylamide) (PNIPAM), a hydrophobic polymer polystyrene (PS) and block co-polymers of PNIPAM-co-PS. The simulations of pure oligomers of PNIPAM and PS and their co-polymers are conducted below and above the LCST of PNIPAM to elucidate the effect of increase in number of PS units in PNIPAM-co-PS co-polymers on the coil-to-globule transition of PNIPAM and structure of proximal water. Our simulations suggest that while the LCST of pure PNIPAM oligomers is strongly associated with the structural changes in the proximal water molecules present near PNIPAM, inclusion of PS units disrupts the interactions between PNIPAM and water and promotes the faster dehydration of PNIPAM chains above its LCST. This phenomenon is manifested by a coil-to-globule transition in PNIPAM chains present in PNIPAM-co-PS co-polymers at much shorter times as compared to the pure PNIPAM oligomers. Our results also reveal that with increase in the number of PS units in PNIPAM-co-PS co-polymers the coil-to-globule transition is accelerated.

36 MATERIALS SCIENCE↗

Numerical analysis of modified Central Solenoid insert design

The United States ITER Project Office (USIPO) is responsible for fabrication of the Central Solenoid (CS) for ITER project. The ITER machine is currently under construction by seven parties in Cadarache, France. The CS Insert (CSI) project should provide a verification of the conductor performance in relevant conditions of temperature, field, currents and mechanical strain. The US IPO designed the CSI that will be tested at the Central Solenoid Model Coil (CSMC) Test Facility at JAEA, Naka. To validate the modified design we performed three-dimensional numerical simulations using coupled solver for simultaneous structural, thermal and electromagnetic analysis. Thermal and electromagnetic simulations supported structural calculations providing necessary loads and strains. According to current analysis design of the modified coil satisfies ITER magnet structural design criteria for the following conditions: (1) room temperature, no current, (2) temperature 4K, no current, (3) temperature 4K, current 60 kA direct charge, and (4) temperature 4K, current 60 kA reverse charge. Fatigue life assessment analysis is performed for the alternating conditions of: temperature 4K, no current, and temperature 4K, current 45 kA direct charge. Results of fatigue analysis show that parts of the coil assembly can be qualified for up to 1 million cycles. Distributions of the Current Sharing Temperature (TCS) in the superconductor were obtained from numerical results using parameterization of the critical surface in the form similar to that proposed for ITER. Lastly, special ADPL scripts were developed for ANSYS allowing one-dimensional representation of TCS along the cable, as well as three-dimensional fields of TCS in superconductor material. Published by Elsevier B.V.

42 ENGINEERING↗

Results of availability imposed configuration details developed for K-DEMO

We completed a two year study using the Korean fusion demonstration reactor (K-DEMO) where we looked at key Tokamak components and configuration options in preparation of a conceptual design phase. A key part of a device configuration centers on defining an arrangement that enhances the ability to reach high availability values by defining design solutions that foster simplified maintenance operations. In order to maximize the size and minimize the number of in-vessel components enlarged TF coils were defined that incorporate a pair of windings within each coil to mitigate pressure drop issues and to reduce the cost of the coils. Furthermore, we defined a semi-permanent shield structure in order to develop labyrinth interfaces between double-null plasma contoured shield modules, provide an entity to align blanket components and provide support against disruption loads—with a load path that equilibrates blanket, TF and PF loads through a base structure. Blanket piping services and auxiliary systems that interface with in-vessel components have played a major role in defining the overall device arrangement—concept details will be presented along with general arrangement features and preliminary results obtained from disruption analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗