Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Open-loop digital frequency multiplier

Monostable multivibrator is implemented by using digital integrated circuits where multiplier constant is too large for conventional phase-locked-loop integrated circuit. A 400 Hz clock is generated by divide-by-N counter from 1 Hz timing reference.

Moore, R. C.↗

Binary phase lock loops for simplified OMEGA receivers

A sampled binary phase lock loop is proposed for periodically correcting OMEGA receiver internal clocks. The circuit is particularly simple to implement and provides a means of generating long range 3.4 KHz difference frequency lanes from simultaneous pair measurements.

Burhans, R. W.↗

DSN research and technology support

The activities at the Venus Station (DSS 13) and the Microwave Test Facility, both operated by the Development Support Group, during the 6-month period ending October 15, 1975, were discussed and progress noted. Successful remote operation of the Venus Station from Pasadena during a pulsar observing track was described, along with significant tracking of the planet Venus in an interferometric planetary radar mode. Completion of the first phase of the demonstration of long-distance (1.6-km) transmission of microwave power was reported, with an RF-to-dc conversion efficiency of better than 80% and 30 kW of dc recovered. Routine transmission of clock synchronization signals to the overseas complexes with 64-m antenna stations was also discussed, and extensive analysis of a reported problem with the DSS 14 HV dc power supply which resulted in excessive ripple voltage interfering with transmitter operation was described.

E. B. Jackson↗

The mini-O, a digital superhet, or a truly low-cost Omega navigation receiver

A quartz tuning fork filter circuit and some unique CMOS clock logic methods provide a very simple OMEGA-VLF receiver with true hyperbolic station pair phase difference outputs. An experimental system was implemented on a single battery-operated circuit board requiring only an external antenna preamplifier, and LOP output recorder. A bench evaluation and preliminary navigation tests indicate the technique is viable and can provide very low-cost OMEGA measurement systems. The method is promising for marine use with small boats in the present form, but might be implemented in conjunction with digital microprocessors for airborne navigation aids.

Burhans, R. W.↗

The Skylab Parasol

An alternate thermal protection system for the Skylab space station cluster was deemed necessary shortly after launch when severe damage occured to the orbital workshop as it passed through the period of maximum dynamic pressure. Data indicated that the combination micrometeoroid and thermal shield on the sun facing side of the vehicle had been destroyed. The simultaneous design, fabrication, and test of the Skylab Parasol System which was completed in 6 days of around-the-clock effort is described. The Skylab Parasol design was selected as the primary sunshade device based on simplicity of design, ability to fabricate quickly, and early demonstration of a working prototype which featured semiautomatic deployment from within the workshop under shirt sleeve environment conditions.

Kinzler, J. A.↗

Narrow band binary phase locked loops

Very high Q digital filtering circuits for audio frequencies in the range of 1Hz to 15 KHz are implemented in simple CMOS hardware using a binary local reference clock frequency. The circuits have application to VLF navigation receivers and other narrow band audio range tracking problems.

Burhans, R. W.↗

Research on techniques for laser ranging to optical corner reflectors on the moon. Research on laser techniques and single photo-electron detection and timing

Experimental studies using a pulsed LED, Cerenkov source, and a 100 ps laser were made of various photomultipliers and discriminator combinations. In addition, a new type of neodymium-YAG frequency doubled laser was used as the basis for the development of a stable, short pulse, high repetition rate laser system. This laser was then used in conjunction with atomic clocks to study the effect of gravitational potential on elapsed time. Avenues to promote the development of international cooperation in the area of lunar laser ranging were also explored.

Alley, C. O.↗

Software for Digital Acquisition System and Application to Environmental Monitoring

Criteria for selection of a minicomputer for use as a core resident acquisition system were developed for the ODU Mobile Air Pollution Laboratory. A comprehensive data acquisition program named MONARCH was instituted in a DEC-8/E-8K 12-bit computer. Up to 32 analog voltage inputs are scanned sequentially, converted to BCD, and then to actual numbers. As many as 16 external devices (valves or any other two-state device) are controlled independently. MONARCH is written as a foreground-background program, controlled by an external clock which interrupts once per minute. Transducer voltages are averaged over user specified time intervals and, upon completion of any desired time sequence, outputted are: day, hour, minute, second; state of external valves; average value of each analogue voltage (E Format); as well as standard deviations of these values. Output is compatible with any serially addressed media.

Copeland, G. E.↗

Development of a drive system for a sequential space camera

Breadboard models of single and dual motor drives for the shutter, claw and magazine of a space camera system were designed and tested. The single motor technique utilizes a single electronically commutated motor to drive the claw and shutter without resorting to a solenoid actuated clutch for pulse operation. Shutter speed is established by a combination of the cinemode speed and the opening of the conventional DAC two piece shutter. Pulse mode operation is obtained by applying power at a fixed clock rate and removing power at an appropriate point in the mechanical cycle such that the motor comes to rest by system friction. The dual motor approach utilizes a stepper motor to drive the shutter and an electronically commutated dc motor to drive the claw and magazine functions. The motors are synchronized electronically.

Sharpsteen, J. T.↗

DSN research and technology support

Continuing testing and refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine pulsar observations of 22 pulsars. Radar observations of geostationary satellite are discussed. Current status of the 400-kW X-band radar is reported along with routine automatic testing of the stability-reliability of the DSS 13 maser-receiver noise adding radiometer combination. A failure in the Faraday rotation receiving system is noted along with discussion in some detail of the activities of the high power transmitter maintenance facility. Continuation of receiver phase stability testing, specifically the effects of temperature on coaxial cables, is discussed and results reported. A demonstration at full power of the microwave power transmission facility is noted and routine support of the planetary radio astronomy experiment is discussed. Transmission of master clock synchronization signals to overseas DSN stations is also reported.

Jackson, E. B.↗

DSN research and technology support

The activities of the Venus Station (DSS 13) and the Microwave Test Facility (MTF) during the period April 19 through June 13, 1976, are discussed and progress noted. Continuing reliability testing and computer program refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine observations of 17 pulsars. Radar observations of a geostationary satellite are reported, along with the routine automatic testing of the stability of the DSS 13 maser-receiving system. Additional testing of thermal characteristics of semiflexible coaxial cables is reported, along with phase stabilization measurements thereon. Routine support of the planetary radio astronomy experiment, with 43.25 hours of observations of Jupiter and various radio calibration sources, is reported, along with 18.75 hours of differential VLBI observations in conjunction with Australia, DSS 43. Modifications of the clock synchronization winterization system are reported, along with a discussion of the activities of the DSN High-Power Transmitter Maintenance Facility.

Jackson, E. B.↗

Solid state, CCD-buried channel, television camera study and design

An investigation of an all solid state television camera design, which uses a buried channel charge-coupled device (CCD) as the image sensor, was undertaken. A 380 x 488 element CCD array was utilized to ensure compatibility with 525 line transmission and display monitor equipment. Specific camera design approaches selected for study and analysis included (a) optional clocking modes for either fast (1/60 second) or normal (1/30 second) frame readout, (b) techniques for the elimination or suppression of CCD blemish effects, and (c) automatic light control and video gain control techniques to eliminate or minimize sensor overload due to bright objects in the scene. Preferred approaches were determined and integrated into a design which addresses the program requirements for a deliverable solid state TV camera.

Hoagland, K. A.↗

The cosmic-ray age deduced from the Be-10 abundance

Satellite measurements of the radioactive cosmic-ray species Be-10 are reported. The abundance was measured near 100 MeV per nucleon with high-resolution solid-state telescopes on the IMP-7 and IMP-8 satellites during 1973 and 1974. These two independent measurements yield Be-10/Be ratios of less than 10 percent. Taken together with a galactic propagation model, these results show that the cosmic-ray 'clock' lifetime (most probable value of the order of 20 million years) is significantly greater than that deduced for a nominal interstellar gas density of the order of 1 to 3 atoms per cu cm.

Garcia-Munoz, M.↗

Experiments on solar photovoltaic power generation using concentrator and liquid cooling

Calculations and experimental data are presented leading to the development of a practical, economical solar photovoltaic power supply. The concept involves concentration of sunlight up to about 100 times normal solar intensity in a solar tracking collector and directing this to an array of solar cells. The cells are immersed in water circulated from a thermal reservoir which limits cell temperature rise to about 20 C above ambient during the day and which cools to ambient temperature during the night. Experiments were conducted on solar cells using a Fresnel lens for magnification, a telescope equatorial mount with clock drive, and tap water circulated through the solar cell holder cavity. Test results show that cells operate satisfactorily under these conditions. Power outputs achieved experimentally with cell optimized for 25 suns were linear with concentration to about 15 suns. Cells optimized for 100 suns were not available, but a corresponding linear relation of power output with concentration is anticipated. Test results have been used in a design analysis of the cost of systems utilizing this technique.

Beam, B. H.↗

An efficient read-out system for multiwire proportional counter hodoscopes

An efficient scanning method for read-out of a multiwire proportional counter hodoscope is presented. This method which utilizes the grouping of wires in the hodoscope read-out system offers distinct advantages in speed and simplicity over systems employing long shift registers. Power consumption and cost can be minimized with this method because of slower clock speeds and a low parts count. This system has been constructed and used on a hodoscope for cosmic-ray trajectory measurements and a lower-power version has been designed for satellite applications.

Austin, R. W.↗

Measurements of air pollutants over a Los Angeles freeway with a bistatic laser system

Nitric oxide, ozone, and ethylene were monitored over roads during periods of heavy traffic by transmitting several known laser wavelengths over an atmospheric path and measuring the differential absorption of the wavelengths. Heavy afternoon traffic between four and five o'clock over a 3.75 km path produced a noticeable increase in ethylene and a decrease in ozone. The changes occurred on a short time scale and correlated with the sudden traffic density increase. The ozone decrease occurs because of the sudden presence of large quantities of nitric oxide. Although the laboratory laser equipment used is rather cumbersome, the measurements did point out the potential of the laser absorption technique for monitoring large areas from one location.-

Menzies, R. T.↗

The relative abundances of galactic cosmic ray Be-7, Be-9, and Be-10

The isotopic composition of galactic cosmic ray Be near 100 MeV/nucleon was measured in interplanetary space with high-resolution solid-state telescopes on the IMP-7 and IMP-8 satellites during 1973-1974. These two independent measurements yield Be-10/Be ratios above 10%. Taken together with the galactic propagation model described in the text, these results show that the cosmic ray 'clock' lifetime (most probable value of roughly 20 million years) is significantly greater than that deduced for a nominal interstellar gas density of about 1 to 3 atoms/cu cm.

Garcia-Munoz, M.↗

Satellite laser ranging work at the Goddard Space Flight Center

The paper describes the satellite laser ranging system at the Goddard Space Flight Center, its range and accuracy capabilities, and planned improvements for future systems. Major subsystems are described, including the laser, optical/mechanical, receiver, computer/software, timing, and laser data preprocessing subsystems. Operational considerations are examined, with attention given the mobile station layout, manpower requirements, and transportability. System performance is considered, with emphasis on system accuracy (calibration, stability, clock synchronization, atmospheric propagation correction) and range capability.

Mcgunigal, T. E.↗