Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Purity monitoring for ProtoDUNE

The next-generation neutrino experiment, DUNE, will utilize a high-intensity neutrino beam produced to measure electron-neutrino appearance and muon-neutrino disappearance with its 40 kilotons (fiducial mass) liquid argon far detector. Liquid argon purity is crucial to use liquid argon time projection chambers (LArTPC) in DUNE’s large detectors. A purity monitor is a miniature TPC that measures the lifetime of photoelectrons generated by its UV-illuminated gold photocathode to measure the purity of liquid argon. ProtoDUNEs are full-scale DUNE prototype LArTPCs built at CERNand perform beam tests. The following will discuss the design, implementation, and results of liquid argon purity monitors deployed in ProtoDUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of terpenoid content in pine by organic solvent extraction and fast-GC analysis

Terpenoids, naturally occurring compounds derived from isoprene units present in pine oleoresin, are a valuable source of chemicals used in solvents, fragrances, flavors, and have shown potential use as a biofuel. This paper describes a method to extract and analyze the terpenoids present in loblolly pine saplings and pine lighter wood. Various extraction solvents were tested over different times and temperatures. Samples were analyzed by pyrolysis-molecular beam mass spectrometry before and after extractions to monitor the extraction efficiency. The pyrolysis studies indicated that the optimal extraction method used a 1:1 hexane/acetone solvent system at 22°C for 1 h. Extracts from the hexane/acetone experiments were analyzed using a low thermal mass modular accelerated column heater for fast-GC/FID analysis. The most abundant terpenoids from the pine samples were quantified, using standard curves, and included the monoterpenes, α- and β-pinene, camphene, and δ-carene. Sesquiterpenes analyzed included caryophyllene, humulene, and α-bisabolene. In conclusion, diterpenoid resin acids were quantified in derivatized extractions, including pimaric, isopimaric, levopimaric, palustric, dehydroabietic, abietic, and neoabietic acids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-G-BRA-09: Estimation of Motion Tracking Uncertainty for Real-Time Adaptive Imaging

Purpose: kV fluoroscopic imaging combined with MV treatment beam imaging has been investigated for intrafractional motion monitoring and correction. It is, however, subject to additional kV imaging dose to normal tissue. To balance tracking accuracy and imaging dose, we previously proposed an adaptive imaging strategy to dynamically decide future imaging type and moments based on motion tracking uncertainty. kV imaging may be used continuously for maximal accuracy or only when the position uncertainty (probability of out of threshold) is high if a preset imaging dose limit is considered. In this work, we propose more accurate methods to estimate tracking uncertainty through analyzing acquired data in real-time. Methods: We simulated motion tracking process based on a previously developed imaging framework (MV + initial seconds of kV imaging) using real-time breathing data from 42 patients. Motion tracking errors for each time point were collected together with the time point’s corresponding features, such as tumor motion speed and 2D tracking error of previous time points, etc. We tested three methods for error uncertainty estimation based on the features: conditional probability distribution, logistic regression modeling, and support vector machine (SVM) classification to detect errors exceeding a threshold. Results: For conditional probability distribution, polynomial regressions on three features (previous tracking error, prediction quality, and cosine of the angle between the trajectory and the treatment beam) showed strong correlation with the variation (uncertainty) of the mean 3D tracking error and its standard deviation: R-square = 0.94 and 0.90, respectively. The logistic regression and SVM classification successfully identified about 95% of tracking errors exceeding 2.5mm threshold. Conclusion: The proposed methods can reliably estimate the motion tracking uncertainty in real-time, which can be used to guide adaptive additional imaging to confirm the tumor is within the margin or initialize motion compensation if it is out of the margin.

60 APPLIED LIFE SCIENCES↗

Non-Intrusive Load Monitoring of EBW Processes A Second Study [Slides]

The Objective is to Determine if induced off-nominal welding disturbances: (1) Beam arc out (weld on high vapor pressure aluminum plate); (2) Pulsed beam voltage; (3) Pulsed beam current; and (4) Pulsed beam focus current can be observed in the input power to the high-voltage cabinet powering the EB gun, ie Non-Instrusive Load Monitoring (NILM).

36 MATERIALS SCIENCE↗

Updates and Lessons Learned from NuMI Beamline at Fermilab

The Neutrinos at the Main Injector (NuMI) beamline at Fermilab generates an intense muon neutrino beam for the NOvA (NuMI Off-axis 𝜈𝑒 Appearance) long baseline neutrino experiment. Over the years, the NuMI beamline has been pivotal in advancing neutrino physics, providing invaluable data and insights. This presentation offers updates and a comprehensive review of the lessons learned from the operation, maintenance, and monitoring of the NuMI beamline. Key topics include the optimization of beam performance, challenges in maintaining beamline stability, and proposed Machine Learning implementations to enhance monitoring. The talk aims to share best practices and provide a roadmap for future beamline projects, including the Long-Baseline Neutrino Facility (LBNF).

Wickremasinghe, Athula↗

Ion-radical synergy in HfO{sub 2} etching studied with a XeF{sub 2}/Ar{sup +} beam setup

To gain more insight into fundamental aspects of the etching behavior of Hf-based high-k materials in plasma etch reactors, HfO{sub 2} films were etched in a multiple-beam setup consisting of a low energy Ar{sup +} ion beam and a XeF{sub 2} radical beam. The etch rate and etch products were monitored by real-time ellipsometry and mass spectrometry, respectively. Although etching of HfO{sub 2} in XeF{sub 2}/Ar{sup +} chemistry is mainly a physical effect, an unambiguous proof of the ion-radical synergistic effect for the etching of HfO{sub 2} is presented. The etch yield for 400 eV Ar{sup +} ions at a substrate temperature of 300 deg. C was 0.3 atoms/ion for Ar{sup +} sputtering and increased to 2 atoms/ion when XeF{sub 2} was also supplied. The etch yield proved to follow the common square root of ion energy dependence both for pure sputtering and radical enhanced etching, with a threshold energy at room temperature of 69{+-}17 eV for Ar{sup +} ions and 54{+-}14 eV for Ar{sup +} ions with XeF{sub 2}.

36 MATERIALS SCIENCE↗

Study of magnetic configuration effects on plasma boundary and measurement of edge electron density in the spherical tokamak compact plasma wall interaction experimental device using Li sheet beam

Two-dimensional lithium beam imaging technique has been applied in the spherical tokamak CPD (compact plasma wall interaction experimental device) to study the effects of magnetic field configurations on rf plasma boundary in the absence of any plasma current, and also for the measurement of a two-dimensional edge electron density profile. With the present working condition of the diagnostics, the minimum measured electron density can be {approx}1.0x10{sup 16} m{sup -3}; this is considered to be the definition for the plasma boundary. The performance of the lithium sheet beam is absolutely calibrated using a quartz crystal monitor. Experimental results reveal that magnetic field configuration, either mirror or so-called null, critically affects the rf plasma boundary. A sharp lower boundary is found to exist in magnetic null configuration, which is quite different from that in the weak mirror configuration. Theoretical calculations of particle drift orbit and magnetic connection length (wall-to-wall) suggest that only mirror trapped particles are confined within a region where the magnetic connection length is {approx}4.0 m or more. A two-dimensional edge electron density profile is obtained from the observed Li I intensity profile. Overdense plasma formation is discussed from the viewpoint of mode conversion of rf wave into electron Bernstein wave and its dependence on the electron density profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrumentation and Beam Dynamics Study of Advanced Electron-Photon Facility in Indiana University

The Advanced eLectron-PHoton fAcility (ALPHA) is a compact electron accelerator under construction and being commissioned at the Indiana University Center for Exploration of Energy and Matter (CEEM). In this thesis, we have studied the refurbished Cooler Injector Synchrotron (CIS) RF cavity using both the transmission line model and SUPERFISH simulation. Both low power and high power RF measurements have been carried out to characterize the cavity. Considering the performance limit of ferrite, we have designed a new ferrite loaded, co-axial quarter wave like cavity with similar structure but a more suitable ferrite material. We have also designed a traveling wave stripline kicker for fast extraction by POISSON and Microwave Studio. The strips geometry is trimmed to maximize the uniformity of the kicking field and match the impedance of the power cables. The time response simulation shows the kicker is fast enough for machine operation. The pulsed power supply requirement has also been specified. For the beam diagnosis in the longitudinal direction, we use a wideband Wall Gap Monitor (WGM) served in CIS. With proper shielding and amplification to get good WGM signal, we have characterized the injected and extracted beam signal in single pass commissioning, and also verified the debunching effect of the ALPHA storage ring. A modulation-demodulation signal processing method is developed to measure the current and longitudinal profile of injected beam. By scanning the dipole strength in the injection line, we have reconstructed the tomography of the longitudinal phase space of the LINAC beam. In the accumulation mode, ALPHA will be operated under a low energy and high current condition, where intra beam scattering (IBS) becomes a dominant effect on the beam emittance. A self consistent simulation, including IBS effect, gas scattering and linear coupling, has been carried out to calculate the emittance of the stored beam.

43 PARTICLE ACCELERATORS↗

Advanced Analytical Methodologies Enable Feedstock Screening and Correlation to Pyrolysis Yields and Catalytic Upgrading

Pyrolysis of lignocellulosic biomass can serve as a powerful pathway for the generation of renewable fuels and industrial products. However, procurement of some biomass may be costly, especially when there is competition for alternative uses. Forestry and agricultural byproducts may serve as valuable pyrolysis feedstocks due to their high availability and low cost. Although waste products may fill demand for affordable pyrolysis feedstocks, they are often high in ash and extractives which contribute to unfavorable changes in pyrolysis vapor composition, as well as end products. The work presented here investigates the correlations between various pine anatomical fractions to understand their effect on pyrolysis oil composition for forest residues. Analytical pyrolysis coupled to direct analysis by molecular beam mass spectrometry (MBMS) provides real-time monitoring of pyrolysis vapor composition, even for compounds that are not amenable to gas chromatography. Statistical analysis of MBMS data from the fast pyrolysis (FP) of clean pine, cambium, twigs and branches, needles, bark, and a forest residue samples revealed that bark and needles made the greatest differences in the vapor composition of forest residues during pyrolysis and were enriched in resin acids, furfural derivatives, and ions that have been previously observed from catalysis corresponding to ash content. These results were also compared to catalytic fast pyrolysis (CFP) using a platinum on titania catalyst, and correlations between FP and CFP products were observed for the anatomical fractions. The forest residues and corresponding anatomical fractions from a stand of 23-year-old pine will be converted by fast pyrolysis in a bench-scale 2-inch fluidized-bed reactor, and statistical correlations between the bench-scale products and analytical-scale pyrolysis vapors will be shown. This work highlights the power of advanced analytical methodologies in determining the contributions of vapor components to catalytic pyrolysis outcomes for mixed feedstocks and demonstrates the use of analytical methodologies to better screen feedstocks prior to pyrolysis.

analytical↗

Amplification of laser imprint in the presence of strong, externally imposed, target-normal magnetic fields

Here, an experiment was performed on the OMEGA EP Laser System to investigate the effects of magnetic fields on laser imprint. A 30 µ⁢m thick CH target was driven by a single beam delivering 3.0 kJ of UV energy in a 5 ns square pulse without smoothing by spectral dispersion. The Rayleigh-Taylor amplification of this beam's imprint on the target surface was monitored using face-on gated x-ray radiography from a Gd backlighter. Magnetic fields of up to 45 T were applied normal to the target surface. Analysis of the resulting radiographs shows a 60 ± 13% increase in the spectrally resolved surface perturbation amplitudes, consistent at all times and for all unsaturated frequencies. This consistency indicates that the increase in perturbation amplitudes was due to a change in the initial amplitudes rather than Rayleigh-Taylor growth. This is supported by the trajectory of individual modes and the inferred time-averaged perturbation growth rates. Laser imprint is therefore inferred to have increased due to strong magnetic fields that remain in the conduction zone of the target, suppressing off-axis electron motion and limiting the effects of thermal smoothing.

direct drive↗

SU-C-207A-02: Proton Radiography Using Pencil Beam Scanning and a Novel, Low-Cost Range Telescope

Purpose: While the energy of therapeutic proton beams can be adjusted to penetrate to any given depth in water, range uncertainties arise in patients due in part to imprecise knowledge of the stopping power of protons in human tissues [1]. Proton radiography is one approach to reduce the beam range uncertainty [2], thereby allowing for a reduction in treatment margins and dose escalation. Methods: The authors have adapted a novel detector technology based on Micromesh Gaseous Structure (“Micromegas”) for proton therapy beams and have demonstrated fine spatial and time resolution of magnetically scanned proton pencil beams, as well as wide dynamic range for dosimetry [3]. The authors have constructed a prototype imaging system comprised of 5 Micromegas layers. Proton radiographs were obtained downstream of solid water assemblies. The position-sensitive monitor chambers in the IBA proton delivery nozzle provide the beam entrance position. Results: Our technique achieves spatial resolution as low as 300 µm and water-equivalent thickness (WET) resolution as good as 0.02% (60 µm out of 31 cm total thickness). The dose delivered to the patient is kept below 2 cGy. The spatial resolution as a function of sample rate and number of delivered protons is found to be near the theoretical Cramer-Rao lower bound. By extrapolating the CR bound, we argue that the imaging dose could be further lowered to 1 mGy, while still achieving submillimeter spatial resolution, by achievable instrumentation and beam delivery modifications. Conclusion: For proton radiography, high spatial and WET resolution can be achieved, with minimal additional dose to patient, by using magnetically scanned proton pencil beams and Micromegas detectors.

60 APPLIED LIFE SCIENCES↗

SU-F-P-30: Clinical Assessment of Auto Beam-Hold Triggered by Fiducial Localization During Prostate RapidArc Delivery

Purpose: To assess the clinical efficacy of auto beam hold during prostate RapidArc delivery, triggered by fiducial localization on kV imaging with a Varian True Beam. Methods: Prostate patients with four gold fiducials were candidates in this study. Daily setup was accomplished by aligning to fiducials using orthogonal kV imaging. During RapidArc delivery, a kV image was automatically acquired with a momentary beam hold every 60 degrees of gantry rotation. The position of each fiducial was identified by a search algorithm and compared to a predetermined 1.4 cm diameter target area. Treatment continued if all the fiducials were within the target area. If any fiducial was outside the target area the beam hold was not released, and the operators determined if the patient needed re-alignment using the daily setup method. Results: Four patients were initially selected. For three patients, the auto beam hold performed seamlessly. In one instance, the system correctly identified misaligned fiducials, stopped treatment, and the patient was re-positioned. The fourth patient had a prosthetic hip which sometimes blocked the fiducials and caused the fiducial search algorithm to fail. The auto beam hold was disabled for this patient and the therapists manually monitored the fiducial positions during treatment. Average delivery time for a 2-arc fraction was increased by 59 seconds. Phantom studies indicated the dose discrepancy related to multiple beam holds is <0.1%. For a plan with 43 fractions, the additional imaging increased dose by an estimated 68 cGy. Conclusion: Automated intrafraction kV imaging can effectively perform auto beam holds due to patient movement, with the exception of prosthetic hip patients. The additional imaging dose and delivery time are clinically acceptable. It may be a cost-effective alternative to Calypso in RapidArc prostate patient delivery. Further study is warranted to explore its feasibility under various clinical conditions.

60 APPLIED LIFE SCIENCES↗

Monitoring technology

A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

Stevenson, William A.↗

Monitoring technology

A process for infrared spectroscopic monitoring of insitu compositional changes in a polymeric material comprises the steps of providing an elongated infrared radiation transmitting fiber that has a transmission portion and a sensor portion, embedding the sensor portion in the polymeric material to be monitored, subjecting the polymeric material to a processing sequence, applying a beam of infrared radiation to the fiber for transmission through the transmitting portion to the sensor portion for modification as a function of properties of the polymeric material, monitoring the modified infrared radiation spectra as the polymeric material is being subjected to the processing sequence to obtain kinetic data on changes in the polymeric material during the processing sequence, and adjusting the processing sequence as a function of the kinetic data provided by the modified infrared radiation spectra information.

Stevenson, William A.↗

Apparatus and method for monitoring of gas having stable isotopes

Gas having stable isotopes is monitored continuously by using a system that sends a modulated laser beam to the gas and collects and transmits the light not absorbed by the gas to a detector. Gas from geological storage, or from the atmosphere can be monitored continuously without collecting samples and transporting them to a lab.

47 OTHER INSTRUMENTATION↗

Online charge measurement for petawatt laser-driven ion acceleration

Laser-driven ion beams have gained considerable attention for their potential use in multidisciplinary research and technology. Preclinical studies into their radiobiological effectiveness have established the prospect of using laser-driven ion beams for radiotherapy. In particular, research into the beneficial effects of ultrahigh instantaneous dose rates is enabled by the high ion bunch charge and uniquely short bunch lengths present for laser-driven ion beams. Such studies require reliable, online dosimetry methods to monitor the bunch charge for every laser shot to ensure that the prescribed dose is accurately applied to the biological sample. In this paper, we present the first successful use of an Integrating Current Transformer (ICT) for laser-driven ion accelerators. This is a noninvasive diagnostic to measure the charge of the accelerated ion bunch. It enables online estimates of the applied dose in radiobiological experiments and facilitates ion beam tuning, in particular, optimization of the laser ion source, and alignment of the proton transport beamline. We present the ICT implementation and the correlation with other diagnostics, such as radiochromic films, a Thomson parabola spectrometer, and a scintillator.

47 OTHER INSTRUMENTATION↗

Clinical Factors Associated With Seroma Volume Reduction in Breast-Conserving Therapy for Early-Stage Breast Cancer: A Multi-Institutional Analysis

Purpose: To correlate clinical factors with seroma volume and reduction; and to determine whether cone-beam CT (CBCT) could be used clinically to monitor seroma reduction. Patients and Methods: This investigation included 102 women from five institutions with stage T1-2 breast cancer treated with breast-conserving therapy. Two CT scans were acquired: the planning CT (CT1) and a second CT (CT2) during radiotherapy (RT). Seroma was contoured on all scans, and correlations between seroma characteristics and clinical factors were investigated by univariate and multivariate analyses. In a substudy, 10 of the 102 patients received multiple CBCT scans during RT. Seroma were contoured by two observers in the substudy. Fifteen time points at which CT and CBCT were performed within 2 days were identified. The levels of correlation in seroma contours between CBCT and CT and between the two observers were examined. Results: The mean relative seroma reduction from CT1 to CT2 was 54% (p < 0.001). A significant inverse relationship was found between relative seroma reduction per week and number of RT fractions given by univariate and multivariate analyses (p = 0.01, 0.03). The mean difference in contoured seroma volumes between CT and CBCT was 12% (3.3 cm{sup 3}). When assessing the relative difference in seroma contours between Observer 1 and Observer 2, an interobserver difference of 12% was demonstrated. Neither discrepancy was clinically significant. Conclusions: Radiotherapy seems to hinder seroma reduction. Volume discrepancies between CBCT and CT were minor, with low interobserver variation, indicating that CBCT might be useful in monitoring seroma reduction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of heterogeneity correction on dosimetric parameters of radiotherapy planning for thoracic esophageal cancer

The present study aimed to investigate the effect of heterogeneity correction (HC) on dosimetric parameters in 3-dimensional conformal radiotherapy planning for patients with thoracic esophageal cancer. We retrospectively analyzed 20 patients. Two treatment plans were generated for each patient using a superposition algorithm on the Xio radiotherapy planning system. The first plan was calculated without HC. The second was a new plan calculated with HC, using identical beam geometries and maintaining the same number of monitor units as the first. With regard to the planning target volume (PTV), the overall mean differences in the prescription dose, maximum dose, mean dose, and dose that covers 95% of the PTV between the first and second plans were 1.10 Gy (1.8%), 1.35 Gy (2.2%), 1.10 Gy (1.9%), and 0.56 Gy (1.0%), respectively. With regard to parameters related to the organs at risk (OARs), the mean differences in the absolute percentages of lung volume receiving greater than 5, 10, 20, and 30 Gy (lung V{sub 5}, V{sub 10}, V{sub 20}, and V{sub 30}) between the first and second plans were 7.1%, 2.7%, 0.4%, and 0.5%, respectively. These results suggest that HC might have a more pronounced effect on the percentages of lung volume receiving lower doses (e.g., V{sub 5} and V{sub 10}) than on the dosimetric parameters related to the PTV and other OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗