Shuttle lidar resonance fluorescence investigations. I - Analysis of Na and K measurements. II - Analysis of thermospheric Mg/+/ measurements

Optical radar systems (lidar) have a number of advantages compared to passive techniques with respect to applications involving the measurement of alkali atoms (Na and K) in the atmosphere. By using Shuttle-borne optical radar systems, analytical capabilities can be extended to cover wider geographic areas. One of the objectives of the present investigation is to assess the performance and application of a recently defined Shuttle optical radar system for the measurements of sodium and potassium in the 80-110-km region. A second objective is related to a study of the effects of high-intensity laser beams on the optical radar measurements, giving particular attention to the saturation in the atomic absorption of laser photons. A numerical simulation is conducted of the measurements of magnesium ions (Mg/+/) over the 80-500-km altitude range using recently defined Shuttle optical radar system parameters to study the performance of such a system.

Yeh, S.-D.↗

Quadrupole mass spectrometer for Space Shuttle applications - Flight capabilities and ground calibration

The AFGL Quadrupole Ion/Neutral Mass Spectrometer (QINMS), its flight capabilities, and a few examples of QINMS data from the STS-4 flight are discussed in addition to the beam facility and calibration procedures used at the Los Alamos National Laboratory facility. A 5-eV atomic oxygen beam is produced using a continuous optical discharge technique, and the resulting pumped beam has sufficient high flux and velocity to simulate orbital conditions. The calibrated instrument will be used in the NASA Johnson Space Center Evaluation of Oxygen Interactions with Materials experiment to measure the density of ambient oxygen and to identify the products of oxygen-surface reactions.

Hunton, D. E.↗

Ground and space based optical analysis of materials degradation in low-Earth-orbit

There is strong interest in being able to accurately and sensitively monitor materials degradation in both ground-based and space-based environments. Two optical techniques for sensitive degradation monitoring are reviewed: spectroscopic ellipsometry and photothermal spectroscopy. These techniques complement each other in that ellipsometry is sensitive to atomically thin surface and subsurface changes, and photothermal spectroscopy is sensitive to local defects, pin-holes, subsurface defects, and delamination. Progress in applying these spectroscopies (both ex situ and in situ) to atomic oxygen degradation of space materials is reviewed.

Woollam, John A.↗

The use of plasma ashers and Monte Carlo modeling for the projection of atomic oxygen durability of protected polymers in low Earth orbit

The results of ground laboratory and in-space exposure of polymeric materials to atomic oxygen has enabled the development of a Monte Carlo computational model which simulates the oxidation processes of both environments. The cost effective projection of long-term low-Earth-orbital durability of protected polymeric materials such as SiO(x)-coated polyimide Kapton photovoltaic array blankets will require ground-based testing to assure power system reliability. Although silicon dioxide thin film protective coatings can greatly extend the useful life of polymeric materials in ground-based testing, the projection of in-space durability based on these results can be made more reliable through the use of modeling which simulates the mechanistic properties of atomic oxygen interaction, and replicates test results in both environments. Techniques to project long-term performance of protected materials, such as the Space Station Freedom solar array blankets, are developed based on ground laboratory experiments, in-space experiments, and computational modeling.

Banks, Bruce A.↗

Determining the Molecular Growth Mechanisms of Tetragonal Lysozyme Crystals

Studies of the growth of tetragonal lysozyme crystals employing atomic force microscopy (AFM) have shown the advantages of this technique in investigating the growth mechanisms of protein crystals [1]. The resolution of these studies was in the micron range, which revealed surface features such as the occurrence of dislocations and 2D nucleation islands, similar to those found in inorganic systems. They clearly showed that the crystals grew by these surface growth mechanisms. However, the studies also revealed some surprising features, such as bimolecular growth step heights and pronounced growth anisotropies on the (110) face, which could not be explained. In previous studies we employed Periodic Bond Chain (PBC) theory to tetragonal lysozyme crystal growth and found that the crystals were constructed by strongly bonded molecular chains forming helices about the 43 axes [2,3]. The helices were connected to each other with weaker bonds. The growth process was shown to proceed by the formation of these 43 helices, resulting in bimolecular growth steps on the (110) face. It was also shown to explain many other observations on tetragonal lysozyme crystal growth. Although PBC analysis is not a new technique [4], it has not been widely used as the mechanisms predicted from it could not be experimentally verified. In this study the growth process of these crystals was investigated, particularly for the (110) face, employing some newly developed high resolution AFM techniques. These techniques allowed individual lysozyme molecules on the crystal faces to be resolved and predictions from PBC analyses to be tested. The analyses had shown that of the two possible packing arrangements on (110) faces, only one would actually occur. Employing the first of the newly developed techniques, these faces were scanned by high resolution AFM. The resulting images were then compared with the theoretically constructed images for the two possible packing arrangements on the (110) face. The theoretical images were constructed by convolution of the crystal surface shape obtained from crystallographic data with the AFM tip shape. The comparison confirmed the prediction that the molecular packing arrangement of these faces corresponded to that for complete 43 helices. The second AFM technique that was developed was used to follow the growth process by measuring the dimensions of individual growth units on the (110) face. Linescans across a growth step, performed near the saturation limit of the crystals, allowed the growth unit dimensions to be measured. These measurements showed that growth on the (110) face proceeded by the formation of new 43 helices from the addition of at least tetramer units in the [110] direction. In the [001] direction growth proceeded by the addition of various aggregate units corresponding to the 4(sub 3) helices.

Li, Huayu↗

New Methods of Sample Preparation for Atom Probe Specimens

Magnetite is a common conductive mineral found on Earth and Mars. Disk-shaped precipitates approximately 40 nm in diameter have been shown to have manganese and aluminum concentrations. Atom-probe field-ion microscopy (APFIM) is the only technique that can potentially quantify the composition of these precipitates. APFIM will be used to characterize geological and planetary materials, analyze samples of interest for geomicrobiology; and, for the metrology of nanoscale instrumentation. Prior to APFIM sample preparation was conducted by electropolishing, the method of sharp shards (MSS), or Bosch process (deep reactive ion etching) with focused ion beam (FIB) milling as a final step. However, new methods are required for difficult samples. Many materials are not easily fabricated using electropolishing, MSS, or the Bosch process, FIB milling is slow and expensive, and wet chemistry and the reactive ion etching are typically limited to Si and other semiconductors. APFIM sample preparation using the dicing saw is commonly used to section semiconductor wafers into individual devices following manufacture. The dicing saw is a time-effective method for preparing high aspect ratio posts of poorly conducting materials. Femtosecond laser micromachining is also suitable for preparation of posts. FIB time required is reduced by about a factor of 10 and multi-tip specimens can easily be fabricated using the dicing saw.

rock varnish↗

Medicine Delivery Device with Integrated Sterilization and Detection

Sterile delivery devices can be created by integrating a medicine delivery instrument with surfaces that are coated with germicidal and anti-fouling material. This requires that a large-surface-area template be developed within a constrained volume to ensure good contact between the delivered medicine and the germicidal material. Both of these can be integrated using JPL-developed silicon nanotip or cryo-etch black silicon technologies with atomic layer deposition (ALD) coating of specific germicidal layers. Nanofabrication techniques that are used to produce a microfluidics device are also capable of synthesizing extremely hig-hsurface-area templates in precise locations, and coating those surfaces with conformal films to manipulate their surface properties. This methodology has been successfully applied at JPL to produce patterned and coated silicon nanotips (also known as black silicon) to manipulate the hydrophilicity of surfaces to direct the spreading of fluids in microdevices. JPL s ALD technique is an ideal method to produce the highly conformal coatings required for this type of application. Certain materials, such as TiO2, have germicidal and anti-fouling properties when they are illuminated with UV light. The proposed delivery device contacts medicine with this high-surface-area black silicon surface coated with a thin-film germicidal deposited conformally with ALD. The coating can also be illuminated with ultraviolet light for the purpose of sterilization or identification of the medicine itself. This constrained volume that is located immediately prior to delivery into a patient, ensures that the medicine delivery device is inherently sterile.

Sheam, Michael J.↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

Advanced EXAFS analysis techniques applied to the L -edges of the lanthanide oxides

The unique properties of the lanthanide (Ln) elements make them critical components of modern technologies, such as lasers, anti-corrosive films and catalysts. Thus, there is significant interest in establishing structure–property relationships for Ln-containing materials to advance these technologies. Extended X-ray absorption fine structure (EXAFS) is an excellent technique for this task considering its ability to determine the average local structure around the Ln atoms for both crystalline and amorphous materials. However, the limited availability of EXAFS reference spectra of the Ln oxides and challenges in the EXAFS analysis have hindered the application of this technique to these elements. The challenges include the limited k-range available for the analysis due to the superposition of L-edges on the EXAFS, multielectron excitations (MEEs) creating erroneous peaks in the EXAFS and the presence of inequivalent absorption sites. Herein, we removed MEEs to model the local atomic environment more accurately for light Ln oxides. Further, we investigated the use of cubic and non-cubic lattice expansion to minimize the fitting parameters needed and connect the fitting parameters to physically meaningful crystal parameters. The cubic expansion reduced the number of fitting parameters but resulted in a statistically worse fit. The non-cubic expansion resulted in a similar quality fit and showed non-isotropic expansion in the crystal lattice of Nd 2 O 3 . In total, the EXAFS spectra and the fits for the entire set of Ln oxides (excluding promethium) are included. The knowledge developed here can assist in the structural determination of a wide variety of Ln compounds and can further studies on their structure–property relationships.

36 MATERIALS SCIENCE↗

On the possibility to detect multipolar order in URu 2 Si 2 by the electric quadrupolar transition of resonant elastic x-ray scattering

Resonant elastic x-ray scattering is a powerful technique for measuring multipolar order parameters. In this paper, we theoretically and experimentally study the possibility of using this technique to detect the proposed multipolar order parameters in URu 2 Si 2 at the U- L 3 edge with the electric quadrupolar transition. Based on an atomic model, we calculate the azimuthal dependence of the quadrupolar transition at the U- L 3 edge. Our results illustrate the potential of this technique for distinguishing different multipolar order parameters. We then perform experiments on ultraclean single crystals of URu 2 Si 2 at the U- L 3 edge to search for the predicted signal, but do not detect any indications of multipolar moments within the experimental uncertainty. We also theoretically estimate the orders of magnitude of the cross section and the expected count rate of the quadrupolar transition and compare them to the dipolar transitions at the U- M 4 and U- L 3 edges, clarifying the difficulty in detecting higher order multipolar order parameters in URu 2 Si 2 in the current experimental setup.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional atomic force microscopy mapping at the solid-liquid interface with fast and flexible data acquisition

We present the implementation of a three-dimensional mapping routine for probing solid-liquid interfaces using frequency modulation atomic force microscopy. Our implementation enables fast and flexible data acquisition of up to 20 channels simultaneously. The acquired data can be directly synchronized with commercial atomic force microscope controllers, making our routine easily extendable for related techniques that require additional data channels, e.g., Kelvin probe force microscopy. Moreover, the closest approach of the tip to the sample is limited by a user-defined threshold, providing the possibility to prevent potential damage to the tip. The performance of our setup is demonstrated by visualizing the hydration structure above the calcite (10.4) surface in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron-Photon Coincidence Calibration Of Photon Detectors

Absolute and relative detector efficiencies measured. Apparatus uses coincidence-counting techniques to measure efficiency of ultraviolet or vacuum ultraviolet detector at very low radiation intensity. Crossed electron and atomic beams generate photons used to calibrate photon detector. Pulses from electron counter and photon detector(s) processed by standard coincidence-counting techniques. Used to calibrate other detectors or make absolute measurements of incident photon fluxes.

Srivastava, Santosh K.↗

Preliminary investigations into UHCRE thermal control materials (A0178)

An overview of the initial work that was done in the ESTEC Materials and Processes Division to evaluate the effect of space environment on the thermal blankets of the Ultra-Heavy Cosmic Ray Nuclei Experiments (UHCRE) is presented. The topics covered include: (1) a preliminary survey of the perforations of the two-thirds of the thermal blanket returned to ESTEC; (2) thermo-optical properties and thickness recessions of three samples cut from each of the third center parts of the 16 thermal blankets were measured and effects of environments (sun illumination and atomic oxygen fluences); (3) contamination was analyzed on trays, external blanket and internal aluminized Kapton foil by IR technique and scanning electron microscopy SEM/EDX examination; (4) the pattern of contamination on the Al Kapton foils was observed, sketched, and related to atomic oxygen flow; and (5) the Long Duration Exposure Facility (LDEF) yaw angle misorientation was evaluated from the contaminated areas visible on some of the trays. In addition, impacts of micrometeoroids and space debris were experimentally simulated on spare flight thermal blankets. Relations between penetration/perforation hole characteristics and projectile parameters were established.

Levadou, Francois↗

Vacuum ultraviolet absorption in a hydrogen arcjet

Atomic absorption spectroscopy was utilized to measure the ground state atomic hydrogen number density in the plasma produced in a low power hydrogen arcjet. A microwave driven hydrogen plasma was used as the source of radiation resonant with the vacuum ultraviolet Lyman alpha transition. The suitability of this radiation source is discussed. The optical depth of this transition prevented measurements at locations where the ground state atomic hydrogen number density was larger than 3 x 10 exp 19/cu m. These results indicate that other single-photon optical diagnostic techniques are equally ineffective in locations of higher hydrogen number density unless the spectral line shape of the atomic hydrogen absorbers is known.

Manzella, David H.↗

On the mobility and contact resistance evaluation for transistors based on MoS{sub 2} or two-dimensional semiconducting atomic crystals

Contact resistance (R{sub c}) can substantially obscure the extracted mobility based on standard transconductance or two-point conductance measurements of field-effect devices especially for low density of states materials such as MoS{sub 2} or similar atomic crystals. Currently, there exists a pressing need for a routine technique that can decouple mobility extraction from R{sub c}. By combining experiments and analysis, we show that the Y-function method offers a robust route for evaluating the low-field mobility, threshold voltage and R{sub c} even when the contact is a Schottky-barrier as is common in two-dimensional transistors. In addition, an independent modified transfer length method evaluation corroborates the Y-function analysis.

36 MATERIALS SCIENCE↗

A new approach to entangling neutral atoms.

Our team has developed a new approach to entangling neutral atoms with a Rydberg-dressed interaction. Entangling neutral atoms is an essential key of quantum technologies such as quantum computation, many-body quantum simulation, and high-precision atomic sensors . The demonstrated Rydberg-dressed protocol involves adiabatically imposing a light shift on the ground state by coupling an excited Rydberg state with a tuned laser field. Using this technique, we have demonstrated a strong and tunable dipole - dipole interaction between two individually trapped atoms with energy shifts of order 1 MHz, which has been challenging to achieve in other protocols . During this program, we experimentally demonstrated Bell-state entanglement and the isomorphism to the Jaynes - Cumming model of a Rydberg-dressed two-atom system. Our theoretical calculations of a CPHASE quantum logic gate and arbitrary Dicke state quantum control in this system encourage further work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Operando XAS/SAXS: Guiding Design of Single-Atom and Subnanocluster Catalysts

Single-atom and subnanocluster catalysts (SSCs) represent a highly promising class of low-cost materials with high catalytic activity and high atom-utilization efficiency. However, SSCs are susceptible to undergo restructuring during the reactions. Exploring the active sites of catalysts through in situ characterization techniques plays a critical role in studying reaction mechanism and guiding the design of optimum catalysts. In situ X-ray absorption spectroscopy/small-angle X-ray scattering (XAS/SAXS) is promising and widely used for monitoring electronic structure, atomic configuration, and size changes of SSCs during real-time working conditions. Unfortunately, there is no detailed summary of XAS/SAXS characterization results of SSCs. The recent advances in applying in situ XAS/SAXS to SSCs are thoroughly summarized in this review, including the atomic structure and oxidation state variations under open circuit and realistic reaction conditions. Furthermore, the reversible transformation of single-atom catalysts (SACs) to subnanoclusters/nanoparticles and the application of in situ XAS/SAXS in subnanoclusters are discussed. To conlcude, the outlooks in modulating the SSCs and developing operando XAS/SAXS for SSCs are highlighted.