Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

Response to 'Comment on 'Heat capacity, enthalpy fluctuations, and configurational entropy in broken ergodic systems'' [J. Chem. Phys. 134, 147101 (2011)]

We show that Johari's critique of our work is based on a misunderstanding of ergodic theory and a disregard for the broken ergodic nature of glass. His analysis is in contradiction with well established experimental results in specific heat spectroscopy, shear-mechanical spectroscopy, and the vanishing of heat capacity in the limit of zero temperature. Based on these misinterpretations, Johari arrives at the erroneous conclusion that the residual entropy of glass is real. However, we show that Johari's result is an artifact in direct contradiction with both rigorous theory and experimental measurements.

36 MATERIALS SCIENCE↗

Beyond Archimedean Space-Time Structure

It took two millennia after Euclid and until in the early 1880s, when we went beyond the ancient axiom of parallels, and inaugurated geometries of curved spaces. In less than one more century, General Relativity followed. At present, physical thinking is still beheld by the yet deeper and equally ancient Archimedean assumption. In view of that, it is argued with some rather easily accessible mathematical support that Theoretical Physics may at last venture into the non-Archimedean realms. In this introductory paper we stress two fundamental consequences of the non-Archimedean approach to Theoretical Physics: one of them for quantum theory and another for relativity theory. From the non-Archimedean viewpoint, the assumption of the existence of minimal quanta of light (of the fixed frequency) is an artifact of the present Archimedean mathematical basis of quantum mechanics. In the same way the assumption of the existence of the maximal velocity, the velocity of light, is a feature of the real space-time structure which is fundamentally Archimedean. Both these assumptions are not justified in corresponding non-Archimedean models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Processing of spectrally resolved x-ray images of inertial confinement fusion implosion cores recorded with multimonochromatic x-ray imagers

We discuss the processing of data recorded with multimonochromatic x-ray imagers (MMI) in inertial confinement fusion experiments. The MMI records hundreds of gated, spectrally resolved images that can be used to unravel the spatial structure of the implosion core. In particular, we present a new method to determine the centers in all the array of images, a better reconstruction technique of narrowband implosion core images, two algorithms to determine the shape and size of the implosion core volume based on reconstructed broadband images recorded along three-quasiorthogonal lines of sight, and the removal of artifacts from the space-integrated spectra.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Errors in particle tracking velocimetry with high-speed cameras

Velocity errors in particle tracking velocimetry (PTV) are studied. When using high-speed video cameras, the velocity error may increase at a high camera frame rate. This increase in velocity error is due to particle-position uncertainty, which is one of the two sources of velocity errors studied here. The other source of error is particle acceleration, which has the opposite trend of diminishing at higher frame rates. Both kinds of errors can propagate into quantities calculated from velocity, such as the kinetic temperature of particles or correlation functions. As demonstrated in a dusty plasma experiment, the kinetic temperature of particles has no unique value when measured using PTV, but depends on the sampling time interval or frame rate. It is also shown that an artifact appears in an autocorrelation function computed from particle positions and velocities, and it becomes more severe when a small sampling-time interval is used. Schemes to reduce these errors are demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ observation of non-hemispherical tip shape formation during laser-assisted atom probe tomography

It is shown by SEM imaging of the tip and by observing the emission pattern of the evaporated atoms that laser assisted evaporation in an atom probe can lead to nonhemispherical tip shapes and time-dependent nonuniform emission. We have investigated this nonuniformity by observing the change in field of view when using laser wavelengths of 515 nm and 343 nm on silicon. The change is monitored in situ by 0.5 nm thick silicon oxide. We demonstrate that the field of view can easily be changed by more than 10 nm and that the apparent oxide layer thickness can deviate substantially from its correct value. The dependence of the tip shape deformations and the reconstruction artifacts on the laser wavelength are explained through simulations of the laser-tip interaction and nonhomogeneous heating effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of signal diffusion on x-ray phase contrast images

We discuss the problem of signal diffusion among neighbouring pixels in x-ray phase contrast imaging (XPCi) specifically for coded-aperture (CA) XPCi, but many of the discussed observations are directly transferable to other XPCi modalities. CA XPCi exploits the principle of pixel edge illumination by means of two CA masks. The first mask, placed in contact with the detector, creates insensitive regions between adjacent pixels; the second one, placed immediately before the sample, creates individual beams impinging on the boundaries between sensitive and insensitive regions on the detector, as created by the detector mask. In this way, edge illumination is achieved for all pixels of an area detector illuminated by a divergent and polychromatic beam generated by a conventional source. As the detector mask redefines the resolution properties of the detector, sample dithering can be used to effectively increase the system spatial resolution, without having to apply any post-processing procedure (e.g., deconvolution). This however creates artifacts in the form of secondary fringes (which have nothing to do with phase-related secondary fringes) if there is signal diffusion between adjacent pixels. In non-dithered images, signal diffusion between adjacent pixels causes a reduction in image contrast. This effect is investigated both theoretically and experimentally, and its direct implications on image quality are discussed. The interplay with the sample positioning with respect to the detector pixel matrix, which also has an effect on the obtained image contrast, is also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low energy Xe milling for the quantitative profiling of active dopants by off-axis electron holography

Off-axis electron holography is a powerful technique that can be used to measure the active dopants in semiconductors. The preparation of thin transmission electron microscopy specimens containing nm-scale regions of interest is extremely challenging and as a consequence ion milling is an essential tool. The exposure of doped specimens to energetic ions creates defects deep in the specimens that trap the active dopants, being the principle cause of what is known as the inactive region. The inactive thickness leads to an underestimation of the dopant potential in the specimens. Here we show that this artifact can be significantly reduced from 140 nm for specimens prepared using only Ga ions at 30 kV to only 10 nm by preparing specimens using 1.5 keV Xe ions for specimens containing p-n junctions with dopant concentrations of 2 x 10{sup 18} cm{sup -3}.

36 MATERIALS SCIENCE↗

Development of an X-ray Micro-Laminography System at SPring-8

An x-ray micro-laminography system has been developed at SPring-8 and applied to measurements of planar objects that cannot be observed by x-ray computed tomography. To reconstruct a sectional image parallel to the planar surface, a filtered back-projection technique considering the inclination angle of a rotational axis was developed. Experimental conditions suitable for laminography measurements in this system were investigated. Spatial resolution in the reconstructed plane was almost determined by the detector resolution, while the spatial resolution perpendicular to the planar surface tended to be worse by the artifacts inherent of the laminographic scanning and reconstruction method. A laminated test sample was clearly observed in three dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

Fabrication of sharp tungsten-coated tip for atomic force microscopy by ion-beam sputter deposition

Tungsten (W) is significantly suitable as a tip material for atomic force microscopy (AFM) because its high mechanical stiffness enables the stable detection of tip-sample interaction forces. We have developed W sputter-coating equipment to compensate the drawbacks of conventional Si cantilever tips used in AFM measurements. By employing an ion gun commonly used for sputter cleaning of a cantilever tip, the equipment is capable of depositing conductive W films in the preparation chamber of a general ultrahigh vacuum (UHV)-AFM system without the need for an additional chamber or transfer system. This enables W coating of a cantilever tip immediately after sputter cleaning of the tip apex and just before the use in AFM observations. The W film consists of grain structures, which prevent tip dulling and provide sharpness (<3 nm in radius of curvature at the apex) comparable to that of the original Si tip apex. We demonstrate that in non-contact (NC)-AFM measurement, a W-coated Si tip can clearly resolve the atomic structures of a Ge(001) surface without any artifacts, indicating that, as a force sensor, the fabricated W-coated Si tip is superior to a bare Si tip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temperature dependence of the dielectric response of AlSb

Spectroscopic ellipometry was used to determine the optical response of an intrinsic AlSb film as a function of temperature. The 1.5 {mu}m thick film was grown on a (001) GaAs substrate by molecular beam epitaxy. Measurements were done at temperatures from 300 K to the growth temperature of 800 K over a spectral range of 0.7 to 5.0 eV. To avoid oxidation artifacts, measurements were done with the film in situ. The data were analyzed using a parametric semiconductor model for its temperature dependence.

36 MATERIALS SCIENCE↗

Dielectric Function Spectra and Critical-Point Energies of Cu2ZnSnSe4 from 0.5 to 9.0 eV

We present dielectric function {var_epsilon} = {var_epsilon}{sub 1} + i{var_epsilon}{sub 2} spectra and critical-point energies of Cu{sub 2}ZnSnSe{sub 4} determined by spectroscopic ellipsometry from 0.5 to 9.0 eV. We reduce artifacts from surface overlayers to the maximum extent possible by performing chemical-mechanical polishing and wet-chemical etching of the surface of a Cu{sub 2}ZnSnSe{sub 4} thin film. Ellipsometric data are analyzed by the multilayer model and the {var_epsilon} spectra are extracted. The data exhibit numerous spectral features associated with critical points, whose energies are obtained by fitting standard lineshapes to second energy derivatives of the data. The experimental results are in good agreement with the {var_epsilon} spectra calculated within the GW quasi-particle approximation, and possible origins of the pronounced critical-point structures are identified.

14 SOLAR ENERGY↗

Coherent control and time-dependent density functional theory: Towards creation of wave packets by ultrashort laser pulses

Explicitly time-dependent density functional theory (TDDFT) is a formally exact theory, which can treat very large systems. However, in practice it is used almost exclusively in the adiabatic approximation and with standard ground state functionals. Therefore, if combined with coherent control theory, it is not clear which control tasks can be achieved reliably, and how this depends on the functionals. In this paper, we continue earlier work in order to establish rules that answer these questions. Specifically, we look at the creation of wave packets by ultrashort laser pulses that contain several excited states. We find that (i) adiabatic TDDFT only works if the system is not driven too far from the ground state, (ii) the permanent dipole moments involved should not differ too much, and (iii) these results are independent of the functional used. Additionally, we find an artifact that produces fluence-dependent excitation energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extracting core shape from x-ray images at the National Ignition Facility

Measuring the shape of implosions is critical to inertial confinement fusion experiments at the National Ignition Facility. We have developed techniques that have proven successful for extracting shape information from images of x-ray self-emission recorded by a variety of diagnostic instruments for both DT-filled targets and low-yield surrogates. These key results help determine optimal laser and target parameters leading to ignition. We have compensated for instrumental response and have employed a variety of image processing methods to remove artifacts from the images while retaining salient features. The implosion shape has been characterized by decomposing intensity contours into Fourier and Legendre modes for different lines of sight. We also describe procedures we have developed for estimating uncertainties in these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

How Grain Boundaries in Cu(In,Ga)Se2 Thin Films are Charged: Revisit

Potential measurements on Cu(In,Ga)Se{sub 2} thin films using scanning Kelvin probe force microscopy have been reported extensively to address grain-boundary (GB) recombination by examining GB charging. However, the results are highly inconsistent. We revisit this issue by measuring high- and low-quality wide-bandgap films and using a complementary method of scanning capacitance microscopy. Our results show consistent positively charged GBs in our high-quality films with minimal surface defects, except for the {Sigma}3[112] GBs, which are charge neutral. We discuss possible artifacts due to surface defects when examining the GB charging and the role of GBs in the device performance.

14 SOLAR ENERGY↗

X-ray Talbot-Lau interferometer for high-speed phase imaging and tomography using white synchrotron radiation

The Talbot interferometer using white synchrotron radiation has already been demonstrated for high-speed X-ray phase imaging and tomography as well as four-dimensional phase tomography for an observation of a dynamic specimen. In those previous experiments, the grating lines were oriented horizontally because the synchrotron radiation source size is large in the horizontal direction, and only the vertical spatial coherence satisfies the requirement for the operation of the Talbot interferometer given its distance from the source. For non-rigid samples, the horizontal axis of rotation causes unwanted motion of the sample due to gravity which results to artifact in the tomography reconstruction. For fluid samples, a vertical rotation axis is certainly necessary. While it is possible to orient the sample rotation axis perpendicular to the grating lines of the Talbot interferometer, solving the definite integral of the differential phase images to obtain the phase shift for x-ray phase tomography proves to be cumbersome when the sample extends outside the image and there is no null region for which the integration constant is known. In this work we aimed at increasing the spatial coherence of the x-rays along the horizontal so that the grating lines and the sample rotation axis could be oriented vertically. A Talbot-Lau interferometer was constructed by adding an absorption grating which acted as vertical line sources of horizontally spatially coherent white synchrotron radiation to the Talbot interferometer. An average of 20% moire fringe visibility was obtained. The set-up was demonstrated for highspeed phase tomography of a polymer sample.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CR mammography: Design and implementation of a quality control program

Despite the recent acquisition of significant quantities of computed radiography CR equipment for mammography, Mexican regulations do not specify the performance requirements for digital systems such as those of CR type. The design of a quality control program QCP specific for CR mammography systems was thus considered relevant. International protocols were taken as reference to define tests, procedures and acceptance criteria. The designed QCP was applied in three CR mammography facilities. Important deficiencies in spatial resolution, noise, image receptor homogeneity, artifacts and breast thickness compensation were detected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large-field high-contrast hard x-ray Zernike phase-contrast nano-imaging beamline at Pohang Light Source

We developed an off-axis-illuminated zone-plate-based hard x-ray Zernike phase-contrast microscope beamline at Pohang Light Source. Owing to condenser optics-free and off-axis illumination, a large field of view was achieved. The pinhole-type Zernike phase plate affords high-contrast images of a cell with minimal artifacts such as the shade-off and halo effects. The setup, including the optics and the alignment, is simple and easy, and allows faster and easier imaging of large bio-samples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent synchrotron radiation for broadband terahertz spectroscopy

We present the first high resolution (10{sup -3} cm{sup -1}) interferometric measurements in the 200-750 GHz range using coherent synchrotron radiation, achieved with a low momentum compaction factor. The effect of microbunching on spectra is shown, depending on the bunch current. A high signal-to-noise ratio is reached thanks to an artifact correction system based on a double detection scheme. Combined to the broad emitted spectral range and high flux (up to 10{sup 5} times the incoherent radiation), this study demonstrates that coherent synchrotron radiation can now be used for stability-demanding applications, such as gas-phase studies of unstable molecules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗