Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,423 records · Page 79

HIGH-MODE RAYLEIGH-TAYLOR GROWTH IN NIF IGNITION CAPSULES

An assessment of short wavelength hydrodynamic stability is an essential component in the optimization of NIF ignition target designs. Using highly-resolved massively-parallel 2-D Hydra simulations, we routinely evaluate target designs up to mode numbers of 2000 ({lambda} {approx} 2 {micro}m). On the outer ablator surface, mode numbers up to {approx}300 ({lambda} {approx} 20 {micro}m) can have significant growth in CH capsule designs. At the internal fuel:ablator interface mode numbers up to {approx}2000 are important for both CH and Be designs. In addition, 'isolated features' on the capsule, such as the 'fill-tube' ({approx} 5 {micro}m scale-length) and defects, can seed short wavelength growth at the ablation front and the fuel:ablator interface, leading to the injection of {approx} 10's ng of ablator material into the central hot-spot. We are developing methods to measure high-mode mix on NIF implosion experiments. X-ray spectroscopic methods are appealing since mix into the hot-spot will result in x-ray emission from the high-Z dopant (Cu or Ge) in the ablator material (Be or CH).

42 ENGINEERING↗

Real-time x-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions

Purpose: X-ray fluoroscopically guided cardiac electrophysiology (EP) procedures are commonly carried out to treat patients with arrhythmias. X-ray images have poor soft tissue contrast and, for this reason, overlay of a three-dimensional (3D) roadmap derived from preprocedural volumetric images can be used to add anatomical information. It is useful to know the position of the catheter electrodes relative to the cardiac anatomy, for example, to record ablation therapy locations during atrial fibrillation therapy. Also, the electrode positions of the coronary sinus (CS) catheter or lasso catheter can be used for road map motion correction.Methods: In this paper, the authors present a novel unified computational framework for image-based catheter detection and tracking without any user interaction. The proposed framework includes fast blob detection, shape-constrained searching and model-based detection. In addition, catheter tracking methods were designed based on the customized catheter models input from the detection method. Three real-time detection and tracking methods are derived from the computational framework to detect or track the three most common types of catheters in EP procedures: the ablation catheter, the CS catheter, and the lasso catheter. Since the proposed methods use the same blob detection method to extract key information from x-ray images, the ablation, CS, and lasso catheters can be detected and tracked simultaneously in real-time.Results: The catheter detection methods were tested on 105 different clinical fluoroscopy sequences taken from 31 clinical procedures. Two-dimensional (2D) detection errors of 0.50 {+-} 0.29, 0.92 {+-} 0.61, and 0.63 {+-} 0.45 mm as well as success rates of 99.4%, 97.2%, and 88.9% were achieved for the CS catheter, ablation catheter, and lasso catheter, respectively. With the tracking method, accuracies were increased to 0.45 {+-} 0.28, 0.64 {+-} 0.37, and 0.53 {+-} 0.38 mm and success rates increased to 100%, 99.2%, and 96.5% for the CS, ablation, and lasso catheters, respectively. Subjective clinical evaluation by three experienced electrophysiologists showed that the detection and tracking results were clinically acceptable.Conclusions: The proposed detection and tracking methods are automatic and can detect and track CS, ablation, and lasso catheters simultaneously and in real-time. The accuracy of the proposed methods is sub-mm and the methods are robust toward low-dose x-ray fluoroscopic images, which are mainly used during EP procedures to maintain low radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Direct Analysis of Single Cells by Mass Spectrometry at Atmospheric Pressure

Analysis of biochemicals in single cells is important for understanding cell metabolism, cell cycle, adaptation, disease states, etc. Even the same cell types exhibit heterogeneous biochemical makeup depending on their physiological conditions and interactions with the environment. Conventional methods of mass spectrometry (MS) used for the analysis of biomolecules in single cells rely on extensive sample preparation. Removing the cells from their natural environment and extensive sample processing could lead to changes in the cellular composition. Ambient ionization methods enable the analysis of samples in their native environment and without extensive sample preparation. The techniques based on the mid infrared (mid-IR) laser ablation of biological materials at 2.94 μm wavelength utilize the sudden excitation of water that results in phase explosion. Ambient ionization techniques based on mid-IR laser radiation, such as laser ablation electrospray ionization (LAESI) and atmospheric pressure infrared matrix-assisted laser desorption ionization (AP IR-MALDI), have successfully demonstrated the ability to directly analyze water-rich tissues and biofluids at atmospheric pressure. In LAESI the mid-IR laser ablation plume that mostly consists of neutral particulate matter from the sample coalesces with highly charged electrospray droplets to produce ions. Recently, mid-IR ablation of single cells was performed by delivering the mid-IR radiation through an etched fiber. The plume generated from this ablation was postionized by an electrospray enabling the analysis of diverse metabolites in single cells by LAESI-MS. This article describes the detailed protocol for single cell analysis using LAESI-MS. The presented video demonstrates the analysis of a single epidermal cell from the skin of an Allium cepa bulb. The schematic of the system is shown in Figure 1. A representative example of single cell ablation and a LAESI mass spectrum from the cell are provided in Figure 2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Percutaneous Irreversible Electroporation (IRE) of Hepatic Malignancy: A Bi-institutional Analysis of Safety and Outcomes

Aim: Irreversible electroporation (IRE) is a non-thermal ablative option in patients unsuitable for standard thermal ablation, due to its potential to preserve collagenous structures (vessels and ducts) and a reduced susceptibility to heat sink effects. In this series from two large tertiary referral hepatobiliary centres, we aim to assess the safety/outcomes of hepatic IRE. Materials and Methods: Bi-institutional retrospective, longitudinal follow-up series of IRE for primary hepatic malignancy; [hepatocellular carcinoma (n = 20), cholangiocarcinoma (n = 3)] and secondary metastatic disease; colorectal (n = 28), neuroendocrine (n = 1), pancreatic (n = 1), breast (n = 1), gastrointestinal stromal tumour (GIST, n = 1) and malignant thymoma (n = 1). Outcome measures included procedural safety/effectiveness, time to progression and time to death. Results: Between 2013 and 2017, 52 patients underwent percutaneous IRE of 59 liver tumours in 53 sessions. All tumours were deemed unsuitable for thermal ablation. Cases were performed using ultrasound (US) or computed tomography (CT) guidance. A complete ablation was achieved in n = 44, (75%) of cases with an overall complication rate of 17% (n = 9). Of the complete ablation group, median time to progression was 8 months. At 12 months, 44% were progression-free (95% CI 30–66%). The data suggest that larger lesion size (> 2 cm) is associated with shorter time to progression and there is highly significant difference with faster time to progression in mCRC compared with HCC. Median survival time was 38 months. Conclusion: This bi-institutional review is the largest UK series of IRE and suggests this ablative technology can be a useful tool, but appears to mainly induce local tumour control rather than cure with HCC having better outcomes than mCRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generation of Subsurface Voids, Incubation Effect, and Formation of Nanoparticles in Short Pulse Laser Interactions with Bulk Metal Targets in Liquid: Molecular Dynamics Study

The ability of short pulse laser ablation in liquids to produce clean colloidal nanoparticles and unusual surface morphology has been employed in a broad range of practical applications. In this paper, we report the results of large-scale molecular dynamics simulations aimed at revealing the key processes that control the surface morphology and nanoparticle size distributions by pulsed laser ablation in liquids. The simulations of bulk Ag targets irradiated in water are performed with an advanced computational model combining a coarse-grained representation of liquid environment and an atomistic description of laser interaction with metal targets. For the irradiation conditions that correspond to the spallation regime in vacuum, the simulations predict that the water environment can prevent the complete separation of the spalled layer from the target, leading to the formation of large subsurface voids stabilized by rapid cooling and solidification. The subsequent irradiation of the laser-modified surface is found to result in a more efficient ablation and nanoparticle generation, thus suggesting the possibility of the incubation effect in multipulse laser ablation in liquids. The simulations performed at higher laser fluences that correspond to the phase explosion regime in vacuum reveal the accumulation of the ablation plume at the interface with the water environment and the formation of a hot metal layer. The water in contact with the metal layer is brought to the supercritical state and provides an environment suitable for nucleation and growth of small metal nanoparticles from metal atoms emitted from the hot metal layer. The metal layer itself has limited stability and can readily disintegrate into large (tens of nanometers) nanoparticles. The layer disintegration is facilitated by the Rayleigh–Taylor instability of the interface between the higher density metal layer decelerated by the pressure from the lighter supercritical water. The nanoparticles emerging from the layer disintegration are rapidly cooled and solidified due to the interaction with water environment, with a cooling rate of ~2 × 10 12 K/s observed in the simulations. The computational prediction of two distinct mechanisms of nanoparticle formation yielding nanoparticles with different characteristic sizes provides a plausible explanation for the experimental observations of bimodal nanoparticle size distributions in laser ablation in liquids. The ultrahigh cooling and solidification rates suggest the possibility for generation of nanoparticles featuring metastable phases and highly nonequilibrium structures.

Chemistry↗

Hydrodynamic instability growth and mix experiments at the National Ignition Facility

Hydrodynamic instability growth and its effects on implosion performance were studied at the National Ignition Facility [G. H. Miller, E. I. Moses, and C. R. Wuest, Opt. Eng. 443, 2841 (2004)]. Implosion performance and mix have been measured at peak compression using plastic shells filled with tritium gas and containing embedded localized carbon-deuterium diagnostic layers in various locations in the ablator. Neutron yield and ion temperature of the deuterium-tritium fusion reactions were used as a measure of shell-gas mix, while neutron yield of the tritium-tritium fusion reaction was used as a measure of implosion performance. The results have indicated that the low-mode hydrodynamic instabilities due to surface roughness were the primary culprits for yield degradation, with atomic ablator-gas mix playing a secondary role. In addition, spherical shells with pre-imposed 2D modulations were used to measure instability growth in the acceleration phase of the implosions. The capsules were imploded using ignition-relevant laser pulses, and ablation-front modulation growth was measured using x-ray radiography for a shell convergence ratio of ∼2. The measured growth was in good agreement with that predicted, thus validating simulations for the fastest growing modulations with mode numbers up to 90 in the acceleration phase. Future experiments will be focused on measurements at higher convergence, higher-mode number modulations, and growth occurring during the deceleration phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Slowing of Femtosecond Laser-Generated Nanoparticles in a Background Gas

The slowing of Pt nanoparticles in argon background gas was characterized by Rayleigh scattering imaging using a plume of nanoparticles generated by femtosecond laser through thin film ablation (fs-TTFA) of 20 nanometers-thick Pt films. The ablation was performed at threshold laser energy fluences for complete film removal to provide a well-defined plume consisting almost entirely of nanoparticles traveling with a narrow velocity distribution, providing a unique system to unambiguously characterize the slowing of nanoparticles during interaction with background gases. Nanoparticles of ~200 nm diameter were found to decelerate in background Ar gas with pressures less than 50 Torr in good agreement with a linear drag model in the Epstein regime. Based on this model, the stopping distance of small nanoparticles in the plume was predicted and tested by particle collection in an off-axis geometry, and size distribution analysis by transmission electron microscopy. These results permit a basis to interpret nanoparticle propagation through background gases in laser ablation plumes that contain mixed components.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Runaway electron seed formation at reactor-relevant temperature

Systematic variation of the pre-disruption core electron temperature (T e ) from 1 to 12 keV using an internal transport barrier scenario reveals a dramatic increase in the production of ‘seed’ runaway electrons (REs), ultimately accessing near-complete conversion of the pre-disruption current into sub-MeV RE current. Injected Ar pellets are observed to ablate more intensely and promptly as T e rises. At high T e , the observed ablation exceeds predictions from published thermal ablation models. Simultaneously, the thermal quench (TQ) is observed to significantly shorten with increasing T e —a surprising result. While the reason for the shorter TQ is not yet understood, candidate mechanisms include: insufficiently accurate thermal ablation models, enhanced ablation driven by the seed RE population, or significant parallel heat transport along stochastic fields. Kinetic modeling that self-consistently treats the plasma cooling via radiation, the induced electric field, and the formation of the seed RE is performed. Including the combined effect of the inherent dependence of hot-tail RE seeding on T e together with the shortened TQ, modeling recovers the progression towards near-complete conversion of the pre-disruption current to RE current as T e rises. Measurement of the HXR spectrum during the early current quench (CQ) reveals a trend of decreasing energy with pre-disruption T e . At the very highest T e (≈ 12 keV), ≈ 100% conversion of the thermal current to runaway current is found. The energy of this peculiar RE beam is inferred to be sub-MeV as it emits vanishingly few MeV hard x-rays (HXRs). These measurements demonstrate novel TQ dynamics as Te is varied and illustrate the limitations of treating the RE seed formation problem without considering the inter-related dependencies of the pellet ablation, radiative energy loss, and resultant variations of the TQ duration. Finally, if the observed shortening of the TQ with increasing T e extends to fusion-grade plasmas, than their propensity to form large quantities of RE seeds at high T e may be far worse than previously thought. Positively, the high T e scenario in DIII-D produces REs so prodigiously that it can serve as a meaningful new platform for demonstrating RE avoidance techniques.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Jet Formation Disruption From a Critical Applied Uniform Axial Magnetic Field

We examine the effects of varying the magnitude of an applied, uniform, axial magnetic field (Bz) on the formation of laboratory plasma jets produced by a 1-MA 100-ns rise time pulsed power generator in a radial foil configuration. A Helmholtz coil applies the external magnetic field (0 to 2 T). With a small-enough applied field, the foil surface ablation is relatively azimuthally uniform, and J×B forces drive the ablated plasma inward and upward to form a well-defined azimuthally symmetric jet. Using applied field strengths larger than a critical Bz = 1.1±0.1 T with aluminum foils, the plasma ablation is not azimuthally uniform, discrete bursts of plasma initiate from the foil surface, and the formation of a well-defined jet is disrupted. The critical Bz for this plasma jet formation disruption correlates with the foil material’s electrical resistivity and equation of state (EOS). To better understand the material-dependent phenomenon, we compare the experimental results with 3-D extended magnetohydrodynamics simulations of ablation of a 2 mm × 2 mm by 25-μm slab that represents a section of the radial foil. The simulations initialize the slab in the solid state and include the material resistivity and EOS from the solid to plasma phases. As is observed in the experimental disruption, these simulations show enhanced nonuniform plasma ablation with an applied Bz, which can inhibit the azimuthal uniformity necessary to produce a well-defined plasma jet. Furthermore, the simulations also show a material and resistivity dependence on the ablation process similar to the trend shown by the experiments. These results demonstrate the necessity of accurate, detailed modeling of material properties during the transition from solid to plasma phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-species impurity granule injection and mass deposition projections in NSTX-U discharges Authors

By employing a neutral gas shielding (NGS) model to characterize impurity granule injection the pedestal atomic deposition for three different species of granule: lithium, boron, and carbon are determined. Utilizing the duration of ablation events recorded on experiments performed at DIII-D to calibrate the NGS model we are able to quantify the ablation rate and mass deposition location with respect to the plasma density profile. The species specific granule shielding constant is then used to model granule ablation within NSTX-U discharges. Simulations of 300, 500 and 700 micron diameter granules injected at 50 m/sec are presented for NSTX-U L-mode type plasmas as well as H-mode discharges with low natural ELM frequencies. Additionally, ablation calculations of 500 micron granules of each species are presented at velocities ranging from 50 - 150 m/sec. In H-mode type discharges these simulations show that the majority of the injected granule is ablated within or just past the steep gradient region of the discharge. At this radial position, the perturbation to the background plasma generated by the ablating granule can lead to conditions advantageous for the rapid triggering of an ELM crash event.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-time airborne particle analyzer

An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

47 OTHER INSTRUMENTATION↗

Methods of analyzing composition of aerosol particles

An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

47 OTHER INSTRUMENTATION↗

Using synchrotron X-ray phase-contrast micro-computed tomography to study tissue damage by laser irradiation: STUDY TISSUE DAMAGE BY LASER IRRADIATION

Background and Objective: The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. Study Design/Materials and Methods: A surgical CO2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phasecontrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. Results: We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumeswere performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. Conclusion: We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues.

Ablation↗

Benchmarking Cylindrical Blast Wave Theory Against the OSIRIS-REx Sample Return Capsule Reentry

Weak shock theory based on cylindrical blast waves has been used to interpret meteor infrasound, but it has not been systematically benchmarked against a non-ablating hypersonic source with independently known parameters. The objective of this study is not to propose a new theoretical framework, but to evaluate the operational validity of the existing suite of blast radius formulations against a high-fidelity ground truth dataset. The OSIRIS-REx Sample Return Capsule reentry on 24 September 2023 provides such a benchmark because the capsule geometry, trajectory, and infrasound emission points are constrained from mission data and ray tracing, reducing source-side uncertainty associated with ablation. Using observations from 39 infrasound stations, this benchmarking study evaluates six published blast radius (${R}_{0}$ ) formulations and three weak-shock transition coefficients ( C ) within a stratified atmospheric propagation model to predict signal period and peak overpressure. The benchmarking identifies the Sakurai formulation as the best-performing formulation for non-ablating bodies, with the Jones/Plooster formulation performing comparably when a physically appropriate C is adopted. Sakurai and Jones/Plooster yield linear-period median absolute percentage residuals of 9% and 11%, respectively. The period predictions show only weak sensitivity to C at these propagation distances. The Mach-diameter approximation commonly used in meteor studies overestimates ${R}_{0}$ by more than a factor of 3 in the absence of ablation. Finally, these results establish a performance baseline for applying cylindrical blast wave theory to effectively non-ablating hypersonic bodies and demonstrate that the signal period is a robust observable for constraining ${R}_{0}$.

atmospheric entry↗

Outcomes of Locoregional Tumor Therapy for Patients with Hepatocellular Carcinoma and Transjugular Intrahepatic Portosystemic Shunts

PurposeLocoregional therapy for hepatocellular carcinoma (HCC) can be challenging in patients with a transjugular intrahepatic portosystemic shunt (TIPS). This study compares safety and imaging response of ablation, chemoembolization, radioembolization, and supportive care in patients with both TIPS and HCC.MethodsThis retrospective study included 48 patients who had both a TIPS and a diagnosis of HCC. Twenty-nine of 48 (60 %) underwent treatment for HCC, and 19/48 (40 %) received best supportive care (i.e., symptomatic management only). While etiology of cirrhosis and indication for TIPS were similar between the two groups, treated patients had better baseline liver function (34 vs. 67 % Child-Pugh class C). Tumor characteristics were similar between the two groups. A total of 39 ablations, 17 chemoembolizations, and 10 yttrium-90 radioembolizations were performed on 29 patients.ResultsAblation procedures resulted in low rates of hepatotoxicity and clinical toxicity. Post-embolization/ablation syndrome occurred more frequently in patients undergoing chemoembolization than ablation (47 vs. 15 %). Significant hepatic dysfunction occurred more frequently in the chemoembolization group than the ablation group. Follow-up imaging response showed objective response in 100 % of ablation procedures, 67 % of radioembolization procedures, and 50 % of chemoembolization procedures (p = 0.001). When censored for OLT, patients undergoing treatment survived longer than patients receiving supportive care (2273 v. 439 days, p = 0.001).ConclusionsAblation appears to be safe and efficacious for HCC in patients with TIPS. Catheter-based approaches are associated with potential increased toxicity in this patient population. Chemoembolization appears to be associated with increased toxicity compared to radioembolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gallbladder Cryoablation: Proof of Concept in a Swine Model for a Percutaneous Alternative to Cholecystectomy

PurposeTo investigate the feasibility of percutaneous gallbladder cryoablation (GBC) under CT guidance in a swine model with histopathologic correlation.Materials and MethodsInstitutional Animal Care and Use Committee approval was obtained for this study protocol. Five pigs underwent GBC. Under CT guidance, 3–4 cryoprobes were positioned percutaneously at the gallbladder margins. Thermocouple probes were placed percutaneously at the gallbladder fundus, neck, free wall, and gallbladder fossa. Two freeze–thaw cycles ranging from 10 to 26 min were performed. The subjects were sacrificed 5 h after cryoablation. The gallbladder and bile ducts were resected, stained, and examined microscopically.ResultsGBC was completed in all subjects. A 10-mm ablation margin was achieved beyond all gallbladder walls. Thermocouple probes reached at least −20 °C. Intra-procedural body temperature decreased to a minimum of 35 °C but recovered after the procedure. Intra- and post-procedural vital signs otherwise remained within physiologic parameters. Non-target ablation occurred in the stomach and colon of the first two subjects. Histology demonstrated complete denudation of the gallbladder epithelium, hemorrhage, and edema within the muscularis layer, and preservation of the microscopic architecture of the common bile duct in all cases.ConclusionPercutaneous gallbladder cryoablation is feasible, with adequate ablation margins obtained and histologic changes demonstrating transmural necrosis. Adjacent structures included in the ablation may require conservative ablation zones, hydrodissection, or continuous saline lavage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PES1 regulates sensitivity of colorectal cancer cells to anticancer drugs

Highlights: ► PES1 was overexpressed in diverse cancer cell lines. ► PES1-ablation enhances DNA damage response by decreasing DNA repair. ► PES1-ablation increases the sensitivity of HCT116 cells to chemotherapeutic agents. ► PES1-ablation is associated with diminished nuclear entry of RAD51. -- Abstract: PES1 (also known as Pescadillo), a nucleolar protein, was involved in biogenesis of ribosomal RNA. Up-regulation of PES1 has been documented in some human cancers, indicating that PES1 may play some crucial roles in tumorigenesis. In our previous study, it was found that silencing of PES1 resulted in decreased proliferation of colorectal cancer cells. We also noticed that depletion of PES1 altered expression profiles of diverse genes. In the present study, we validated the expression changes of a subset of genotoxic stress-related genes in PES1-silenced HCT116 cells by quantitative RT-PCR. The steady and etoposide-induced phosphorylated H2AX (γ-H2AX) were higher in PES1-silenced cells than in control cells. Besides, etoposide-induced γ-H2AX persisted longer in PES1-silenced cells after removing the etoposide. Next, results of comet assay revealed decreased DNA repair after PES1-ablation. PES1-ablated cells were more sensitive to chemotherapeutic agents, which could be reversed by reconstitution with exogenous PES1. Furthermore, deletion of PES1 diminished steady and DNA damage-induced levels of nuclear RAD51. Our results uncover a potential role of PES1 in chemoresistance by regulating DNA damage response in colorectal cancer cells.

60 APPLIED LIFE SCIENCES↗

Combining Laser Ablation/Liquid Phase Collection Surface Sampling and High-Performance Liquid Chromatography Electrospray Ionization Mass Spectrometry

This paper describes the coupling of ambient pressure transmission geometry laser ablation with a liquid phase sample collection method for surface sampling and ionization with subsequent mass spectral analysis. A commercially available autosampler was adapted to produce a liquid droplet at the end of the syringe injection needle while in close proximity to the surface to collect the sample plume produced by laser ablation. The sample collection was followed by either flow injection or a high performance liquid chromatography (HPLC) separation of the extracted components and detection with electrospray ionization mass spectrometry (ESI-MS). To illustrate the analytical utility of this coupling, thin films of a commercial ink sample containing rhodamine 6G and of mixed isobaric rhodamine B and 6G dyes on glass microscope slides were analyzed. The flow injection and HPLC/ESI-MS analysis revealed successful laser ablation, capture and, with HPLC, the separation of the two compounds. The ablated circular area was about 70 m in diameter for these experiments. The spatial sampling resolution afforded by the laser ablation, as well as the ability to use sample processing methods like HPLC between the sample collection and ionization steps, makes this combined surface sampling/ionization technique a highly versatile analytical tool.

Laser Ablation↗