Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

An Optimized Photoelectron Track Reconstruction Method for Photoelectric X-Ray Polarimeters

We present a data processing algorithm for angular reconstruction and event selection applied to 2-D photoelectron track images from X-ray polarimeters. The method reconstructs the initial emission angle of a photoelectron from the initial portion of the track, which is obtained by continuously cutting a track until the image moments or number of pixels fall below tunable thresholds. In addition, event selection which rejects round tracks quantified with eccentricity and circularity is performed so that polarimetry sensitivity considering a trade-off between the modulation factor and signal acceptance is maximized. The modulation factors with applying track selection are 26.6 ± 0.4, 46.1 ± 0.4, 62.3 ± 0.4, and 61.8 ± 0.3% at 2.7, 4.5, 6.4, and 8.0 keV, respectively, using the same data previously analyzed by Iwakiri et al. (2016), where the corresponding numbers are 26.9±0.4, 43.4±0.4, 54.4±0.3, and 59.1 ± 0.3%. The method improves polarimeter sensitivity by 5%–10% at the high energy end of the band previously presented (Iwakiri et al. 2016).

Kitaguchi, Takao↗

Aerogel Scattering Filters for Cosmic Microwave Background Observations

We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and sub-millimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultra-low-density (< 100 mg/cu cm) aerogel substrate provides an index of refraction as low as 1.05, removing the need for anti-reflection coatings and allowing for broadband operation from DC to above 1 THz. The size distribution of the scattering particles can be tuned to provide a variable cutoff frequency. Aerogel filters with embedded high-resistivity silicon powder are being produced at 40-cm diameter to enable large-aperture cryogenic receivers for cosmic microwave background polarimeters, which require large arrays of sub-Kelvin detectors in their search for the signature of an inflationary gravitational-wave background.

Essinger-Hileman, Thomas↗

Compact Multi-Channel Infrared Laser Absorption Spectrometer for Spacecraft Fire Safety Monitoring

We report on the design of a six-channel tunable laser absorption spectroscopy instrument for measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of fire events while also indicating what materials have been exposed to heating. Continued post-fire monitoring of these hazardous gases can also facilitate safe and effective cleanup. The sensor is a miniaturized version of a five-channel prototype that was previously validated in ground-based oxidative pyrolysis tests. Here, we describe absorption line selection and theoretical detection limits for a sensor with reduced absorption pathlengths for each detection channel, which allows for a substantial reduction in overall instrument footprint. Ultimately, the new instrument is designed to be used in fire safety tests conducted by NASA, where various materials will undergo oxidative pyrolysis in an unmanned spacecraft returning from low Earth orbit.

Briggs, Ryan M.↗

Goddard Laser for Absolute Measurement of Radiance

High accuracy achieved with temperature stabilized unfiltered trap detectors illuminated by monochromatic light. Tunable lasers and optical parametric oscillators provide orders of magnitude higher spectral radiance than blackbody or other broadband sources; calibrate at high signal levels.

McAndrew, Brendan↗

Time Resolved Irradiance of an Integrating Sphere Illuminated by a Mode-Locked Optical Parametric Oscillator

Tunable laser based illumination sources have been adopted by a number of recent hyperspectral instruments for pre-launch spectral radiometric calibration. Some of these sources use mode-locked cavity configurations, which produce a pulse train and create an undesirable fluctuation in the radiometric source at the mode locking frequency. Although typically this frequency is several orders of magnitude higher than the instrument response, care must be taken to ensure the resultant calibration is not biased due to detector or electronic saturation effects. The temporal averaging properties of an integrating sphere can be used to reduce high frequency fluctuations to an acceptable level. In this work, the time resolved output of an integrating sphere coupled with a mode-locked source was measured. A 76 cm diameter sphere with 30 cm output aperture was illuminated using a mode-locked pulse train at 76 MHz, with single pulse durations of 12 ps. The time constant of the sphere was found to be 36 ns, and the resultant temporal averaging of pulses produced a maximum time varying irradiance at the output of 20% of the mean. The form of this time variance is a sawtooth pattern, with a sharp rise during the introduction of each pulse into the sphere followed by a slower decay between pulses. A comparison of instrument calibration data generated with this integrating sphere using both a mode locked source and a continuous wave source is also given. .

McAndrew, Brendan↗

Polarization-Controlled Directional Multiphoton Photoemission from Hot Spots on Single Au Nanoshells

Directional photoemission from single Au nanoshells is demonstrated in the low-intensity, multiphoton regime. Thisdirectionality is shown to be due to the plasmonic excitation of highly photoemissive, nanometer scale surface regions, which are characterized by correlated momentum mapping, scanning electron microscopy (SEM), and laser polarization-dependence studies. Furthermore, the photoelectron flux from a single nanoshell can be systematically rotated by over 90° in momentum space simply by polarization-controlled coupling to different hot spots. Photoelectrondistributions are directly characterized in momentum space via velocity map imaging (VMI) of the two-dimensional transverse (px, py) momentum components for single nanoshells. For the majority of nanoshells studied, the photoemission is directionally orthogonal to the laser polarization, which implicates nanoscale crevice-shaped "hotspots" clearly observed in the correlated SEM/VMI studies, with the near-field plasmonic nature of these crevices clarified further via finite-element simulations. These results rationalize the large photoemission enhancements observed in previous Au nanoshell studies, but more importantly provide a novel experimental access to directionally tunable electron emission from nanoscale sources. The ability to control photoemission/photocurrent angular distributions at the nanoscale with only modest optical fields indicates a new parameter for optimizing nanoplasmonic system performance and suggests new plasmonic applications such as ultrafast, polarization-controlled photoelectric/photovoltaic switches.

Pettine, Jacob↗

Uncertainties for Pre- and Post-Launch Radiometric Calibration of Imaging Spectrometers for Multi-Sensor Applications

An important aspect to using imaging spectrometer data is the radiometric characterization and calibration of the sensors and validation of their data products and doing so with error budgets with known traceability. The radiometric accuracy of a given sensor is important for demonstrating the expected quality of data from the sensor. Known traceability allows data from multiple sensors to be directly comparable as will become more important in the near future with the expected launches of multiple imaging spectrometers from multiple countries, agencies, and commercial entities. The current work describes the state of pre- and post-launch radiometric absolute and relative uncertainties and their role in harmonising on-orbit data. Examples of prelaunch uncertainties based on the calibration of EnMAP and the calibration planned for the CLARREO Pathfinder Mission are presented highlighting recent work in the area of detector-based approaches using tunable laser sources. Post-launch calibration approaches for Pathfinder, EnMAP, CHIME, and DESIS including traditional vicarious calibration methods and the challenges of working with commercial data are presented. The vicarious calibration discussion relies on the example of the recently-available RadCalNet data to describe typical methods and challenges that will be faced when harmonising data between imaging spectrometers as well as with multispectral sensors.

Thome, K.↗

Mid Lift-to-Drag Ratio Rigid Vehicle 6-DoF Performance for Human Mars Entry, Descent, and Landing: A Fractional Polynomial Powered Descent Guidance Approach

Defining a feasible vehicle design and mission architecture capable of reliably delivering apayload of 20 metric tons (mt) or more is a great challenge for landing humans on Mars. TheMid Lift-to-Drag Rigid Vehicle (MRV), a rigid decelerator studied in NASA’s Entry, Descent,and Landing Architecture Study (EDLAS), has shown to be a viable vehicle candidate forfuture human Mars missions. As the vehicle concept matures, models of increasing fidelity areadded to the six-degree-of-freedom (6DoF) EDL simulation. This paper presents 6DoFsimulation results using model updates for vehicle mass properties, fineness ratio, andaerodynamic-propulsive interactions. Additionally, an assessment of the Fractional-Polynomial Powered Descent Guidance (FP2DG) performance is presented, and the vehicleperformance is compared with the Tunable Apollo Powered Descent Guidance (TAPDG).Finally, Monte Carlo results of the vehicle design trades are presented.

Johnson, Breanna J.↗

Improvements in Ionic Liquid Technology for Carbon Dioxide Removal Applications

Carbon dioxide removal from cabin air continues to be of vital importance for future space missions. Current and proposed approaches have employed solid sorbents, hollow fiber membrane separators, and direct liquid sorbent contactors. Recent developments in ionic liquids have potential to improve performance in all three of these technologies. Efficient encapsulation of ionic liquids by polymeric shell can enable their use in a solid sorbent-like configuration without significant integration intervention to the current space technology. Poly(ionic liquid)-ionic liquid membranes have the potential to cross over the Robeson selectivity-permeability upper bound, and thereby outperform traditional membranes used in hollow fibers. Advances in ionic liquid chemistry enables performance improvements in liquid sorbent contactors owing to the tunable gravimetric CO2 capacity, reaction enthalpy and liquid viscosity. This paper will describe recent work in each of these areas.

Ionic Liquid,Carbon Dioxide,Air Revitalization↗

Applying Sensor Uncertainty Mitigation Schemes to Detect-and-Avoid Systems

Impact of sensor noise on the performance of Detect-And-Avoid (DAA) systems can be reduced by implementing various mitigation schemes. This paper evaluates the Sensor Uncertainty Mitigation (SUM) method, implemented in the Detect and Avoid Alerting Logic for Unmanned Systems (DAIDALUS) algorithm, a reference implementation in the DAA minimum operational performance standards. DAIDALUS SUM performance is evaluated using a few safety and operational suitability metrics and compared with more traditional approaches using static safety buffers. A large number of encounters representative of low-speed unmanned aircraft against non-cooperative manned aircraft are simulated and evaluated. An air-to-air radar model produces representative sensor noise for the DAA system. Results show that increasing the tunable parameters for horizontal and vertical uncertainty in DAIDALUS SUM improves the safety metric at the cost of increasing the number of system alerts leading to increased workload. A range of SUM parameters is recommended as suitable values for the type of operations considered for this work. General trends and optimal SUM configurations were found to be nearly the same for two large and very different encounter data sets.

detect and avoid↗

Aerogel Scattering Filters for Cosmic Microwave Background Observations

We present the design and performance of broadband and tunable infrared-blocking filters for millimeter and submillimeter astronomy composed of small scattering particles embedded in an aerogel substrate. The ultralow-density (typically<150 mg/cm3) aerogel substrate provides an index of refraction as low as 1.05, removing the need for antireflection coatings and allowing for broadband operation from DC to above 1 THz. The size distribution of the scattering particles can be tuned to provide a variable cutoff frequency. Aerogel filters with embedded high-resistivity silicon powder are being produced at 40 cm diameter to enable large-aperture cryogenic receivers for cosmic microwave background polarimeters, which require large arrays of sub-Kelvin detectors in their search for the signature of an inflationary gravitational-wave background.

Thomas Essinger-Hileman↗

Microwave Power Detection With Voltage-Gated Graphene

Commercially available, chemical vapor deposition grown, graphene has been used to realizevoltage-gate tunable, microwave power detectors. Corbino disc structures with chrome/gold contacts havebeen fabricated on top of graphene deposited on P-type silicon substrates with silicon dioxide gate oxides.Devices of varying sizes were used to detect a 433.92 MHz signal. These test structures exhibited a peak power detection sensitivity of 3.25 mV/mW at 292 K and 5.43 mV/mW at 80 K. The improved graphene detectors exceed the sensitivity of previously reported graphene detectors, 0.86 mV/mW, as well as previously explored carbon nanotube bolometers, 0.36 mV/mW

Michael R. Gasper↗

Sliding Mode Transient Scaling Controller for Gas Turbine Engine Emulation on an Electric Machine

The testing of hybrid-electric aircraft propulsion system components and control strategies has dictated the need for a low-cost gas turbine engine (GTE) emulation testbed. Within that testbed, electric machines (EMs) are used to emulate the dynamics of a GTE. GTE mathematical models are used to provide control torque commands to EMs. Most GTEs operate at much higher power levels than commercially available EMs. Therefore, the transient shaft dynamics of the GTE must be scaled appropriately. The sliding mode controller being presented here aims to deliver a control torque to an electric machine with a fixed inertia that will allow it to mimic the response of a GTE with a different inertia. This solution provides an easily scalable and tunable transient emulation method without having to scale the GTE mathematical model and/or add inertia to the physical EM shaft. This controller has been proven in simulation to produce nearly identical transient rotational speed response to a reference GTE shaft model which has a large difference in rotational inertia compared to the motor. Also, the inherent robustness of the sliding mode control scheme results in negligible changes in performance for large amounts of parameter uncertainty while minimizing high frequency fluctuations in the control signal.

sliding mode↗

Improvements in CALIOP Smoke Optical Depth over Clouds

Smoke over marine stratocumulus is ubiquitous off the south west coast of Africa during biomass burning season. The vertical profile measurements provided by the CALIOP lidar are successfully able to distinguish between smoke and underlying clouds. With over 14 years of observations, the CALIOP data set is a valuable asset for quantifying the radiative impact of smoke over clouds in this region. However past studies have shown that CALIOP overestimates the base altitudes of strongly attenuating smoke layers. This is because CALIOP layer detection operates on the 532 nm attenuated backscatter signal. Smoke strongly attenuates light at this wavelength, so CALIOP feature detection at times assigns a base altitude that is higher than the true layer base for optically thick layers. This can be confirmed by the 1064 nm attenuated backscatter signal, also measured by CALIOP. In order to improve the AOD for smoke over clouds, a new algorithm has been implemented in for an upcoming CALIOP level 2 data release that will extend the base altitudes of smoke layers over clouds. Tunable restrictions are put in place to ensure that smoke bases are only extended within a reasonable smoke-to-cloud gap distance and only when there is strong reason to believe that smoke exists within the gap. This presentation will summarize the new smoke base extension algorithm and summarize its performance. We will demonstrate that base extension is primarily invoked off the south west coast of Africa as expected. We will also quantify the increase in smoke AOD that will be reported in the upcoming level 2 data release.

Jason L Tackett↗

AOTF Polarimetric Hyperspectral Imaging for Mine Detection.

This paper reports an analysis of polarimetric hyperspectral imagery of an outdoor scene containing a number of inactive mines. The imagery was taken with a visible/near-infrared acousto-optic tunable filter prototype system. The result has illustrated that the characteristics of mine smooth surfaces can create high signals in polarization difference images and consequently provide a quick and reliable approach for detection.

['Mine↗

Mine Discrimination Using Multispectral Imagery With Feedforward Neural Networks

Simulated mine detection was performed on a polarimetric hyperspectral imaging dataset collected by using an acousto-optic tunable filter camera. A feedforward artificial neural network was programmed to recognize predefined spectral "templates." The simulation results are provided along with the preprocessing steps and window sizes leading to mine detection without false alarms.

polarimetric↗