Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning

Purpose: To develop a novel algorithm that incorporates prior treatment knowledge into intensity modulated radiation therapy optimization to facilitate automatic treatment planning and adaptive radiotherapy (ART) replanning. Methods: The algorithm automatically creates a treatment plan guided by the DVH curves of a reference plan that contains information on the clinician-approved dose-volume trade-offs among different targets/organs and among different portions of a DVH curve for an organ. In ART, the reference plan is the initial plan for the same patient, while for automatic treatment planning the reference plan is selected from a library of clinically approved and delivered plans of previously treated patients with similar medical conditions and geometry. The proposed algorithm employs a voxel-based optimization model and navigates the large voxel-based Pareto surface. The voxel weights are iteratively adjusted to approach a plan that is similar to the reference plan in terms of the DVHs. If the reference plan is feasible but not Pareto optimal, the algorithm generates a Pareto optimal plan with the DVHs better than the reference ones. If the reference plan is too restricting for the new geometry, the algorithm generates a Pareto plan with DVHs close to the reference ones. In both cases, the new plans have similar DVH trade-offs as the reference plans. Results: The algorithm was tested using three patient cases and found to be able to automatically adjust the voxel-weighting factors in order to generate a Pareto plan with similar DVH trade-offs as the reference plan. The algorithm has also been implemented on a GPU for high efficiency. Conclusions: A novel prior-knowledge-based optimization algorithm has been developed that automatically adjust the voxel weights and generate a clinical optimal plan at high efficiency. It is found that the new algorithm can significantly improve the plan quality and planning efficiency in ART replanning and automatic treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Corrective Action Investigation Plan for Corrective Action Unit 568: Area 3 Plutonium Dispersion Sites Nevada National Security Site, Nevada

CAU 568 is a grouping of sites where there has been a suspected release of contamination associated with nuclear testing. This document describes the planned investigation of CAU 568, which comprises the following corrective action sites (CASs): (1) 03-23-17, S-3I Contamination Area; (2) 03-23-19, T-3U Contamination Area; (3) 03-23-20, Otero Contamination Area; (4) 03-23-22, Platypus Contamination Area; (5) 03-23-23, San Juan Contamination Area; and (6) 03-23-26, Shrew/Wolverine Contamination Area. These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the investigation report.

54 ENVIRONMENTAL SCIENCES↗

Development of Surface Sampling Techniques for the Canister Deposition Field Demonstration (FY22 Update)

This report describes the proposed surface sampling techniques and plan for the multi-year Canister Deposition Field Demonstration (CDFD). The CDFD is primarily a dust deposition test that will use three commercial 32PTH2 NUHOMS welded stainless steel storage canisters in Advanced Horizontal Storage Modules, with planned exposure testing for up to 10 years at an operating ISFSI site. One canister will be left at ambient condition, unheated; the other two will have heaters to achieve canister surface temperatures that match, to the degree possible, spent nuclear fuel (SNF) loaded canisters with heat loads of 10 kW and 40 kW. Surface sampling campaigns for dust analysis will take place on a yearly or bi-yearly basis. The goal of the planned dust sampling and analysis is to determine important environmental parameters that impact the potential occurrence of stress corrosion cracking on SNF dry storage canisters. Specifically, measured dust deposition rates and deposited particle sizes will improve parameterization of dust deposition models employed to predict the potential occurrence and timing of stress corrosion cracks on the stainless steel SNF canisters. The size, morphology, and composition of the deposited dust and salt particles will be quantified, as well as the soluble salt load per unit area and the rate of deposition, as a function of canister surface temperature, location, time, and orientation. Previously, a preliminary sampling plan was developed, identifying possible sampling locations on the canister surfaces and sampling intervals; possible sampling methods were also described. Further development of the sampling plan has commenced through three different tasks. First, canister surface roughness, a potentially important parameter for air flow and dust deposition, was characterized at several locations on one of the test canisters. Second, corrosion testing to evaluate the potential lifetime and aging of thermocouple wires, spot welds, and attachments was initiated. Third, hand sampling protocols were developed, and initial testing was carried out. The results of those efforts are presented in this report. The information obtained from the CDFD will be critical for ongoing efforts to develop a detailed understanding of the potential for stress corrosion cracking of SNF dry storage canisters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference

Purpose: First, to show that low-dose-rate prostate brachytherapy plans using oblique needle trajectories are more successful than parallel trajectories for large prostates with pubic arch interference (PAI); second, to test the accuracy of delivering an oblique plan by using a three-dimensional (3D) transrectal ultrasonography (TRUS)-guided mechatronic system. Methods and Materials: Prostates were contoured for 5 subjects' 3D TRUS images showing a maximum PAI of {<=}1 cm and a prostate volume of <50 cc. Two planning studies were done. First, prostate contours were artificially enlarged to 45 to 80 cc in 5- to 10-cc increments for a single subject. Second, all subject prostate contours were enlarged to 60 cc. For each study, three types of plans were manually created for comparison: a parallel needle template (PT) plan, a parallel needle no-template (PNT) plan, and an oblique needle no-template (OBL) plan. Needle positions and angles were not discretized for nontemplate plans. European Society for Therapeutic Radiology and Oncology dose-volume histogram guidelines, iodine-125 (145-Gy prescription, 0.43 U), and needle angles of <15 Degree-Sign were used. An OBL plan was delivered to a pubic arch containing a 60-cc prostate phantom that mimicked the anatomy of the subject with the greatest PAI (23% by volume). Results: In the increasing-prostate volume study, OBL plans were successful for prostates of {<=}80 cc, and PT plans were successful for prostates of <65 cc. In paired, one-sided t tests for the 60-cc volume study, OBL plans showed dosimetric improvements for all organs compared to both of the parallel type plans (p < 0.05); PNT plans showed a benefit only in planning target volumes receiving more than 100 Gy compared to PT plans. A computed tomography scan of the phantom showed submillimeter seed placement accuracy in all directions. Conclusion: OBL plans were significantly better than parallel plans, and an OBL plan was accurately delivered to a 60-cc prostate phantom with 23% PAI by volume.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reuse Permit I-161-02 Quality Assurance Project Plan (QAPP) for Required Environmental and Process Monitoring. Idaho National Laboratory Advanced Test Reactor (ATR) Complex Cold Waste Ponds

The Department of Environmental Quality (DEQ) issued Reuse Permit No. I-161-02 (hereafter permit) for the Idaho National Laboratory (INL) Advanced Test Reactor (ATR) Complex Cold Waste Ponds (CWP) on November 20, 2014. Permit Section 3 compliance activity (CA), CA-161-02, requires the permittee to prepare and implement a Quality Assurance Project Plan (QAPP) within 6 months of permit issuance. This QAPP is prepared in accordance with CA-161-02 using a template provided by DEQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Development of a Beam Halo Monitor

Muons, Inc. proposed improved Residual-Gas luminescent Beam Profile Monitors for Intense Beams by adding novel features including a mirascope, a light collecting device devised in the 16th century by an inventor of the telescope. A modern mirascope consists of 2 paraboloids. Light generated by the beam is collected by the paraboloids and creates a beam image. By placing a lens near the image it is possible to collect almost 100% of the emitted light, up to ten times better than existing fluorescence profilometers. Intense (multi-MW) proton beams pose a challenge for beam profile measurements. Solid-based beam intercepting instrumentation produces unallowable levels of radiation at these high powers. An alternative is to use a zero-or-low mass device such as a residual-gas profile monitor, either through collection of ionization or fluorescence. Fluorescence has an intrinsic advantage over the usual collection of ionized electrons in that it is not affected by the strong and variable electric and magnetic fields created by the beam that can distort profiles and make calibration difficult. For this reason, we proposed the fluorescence technique using the mirascope and other methods to enhance light collection and versatility by modifying the residual gas and its spatial distribution. In Phase I, we designed a mirascope and its electronics for commissioning and beam tests in a proposed Phase II. The design was based on optical simulations done in Phase I, and a physics run plan was developed for optimizing and testing. The Phase II experimental site and program have been planned and our goal is to produce a universal low cost Mirascope Residual-Gas Luminescent Beam Profile Monitor that can replace all other profile monitors currently used in accelerators.

43 PARTICLE ACCELERATORS↗

Fuel Safety Research Plan for Accident Tolerant Fuels

This document outlines a strategic plan for a safety research program for accident tolerant fuels. Accident tolerant fuels (ATFs) are nuclear fuel materials and designs for existing and future light water reactors. This effort is under the Department of Energy Office of Nuclear Energy’s Nuclear Technology Research and Development Advanced Fuels Campaign. The development of ATF is an industry lead initiative with fuel designs being championed by Westinghouse, Framatome, and General Electric. Industry goals for ATF deployment include implementing the first batch reloads of coated cladding and doped fuel designs into commercial reactors by 2023 and having the first batch reloads of more advanced designs into commercial reactors by 2026. Follow on goals include implementing the first full cores of coated cladding and doped fuel designs into commercial reactors by 2026 and implementing full cores of more advanced designs by 2030. The objectives of the national laboratory research programs within the Advanced Fuels Campaign related to ATF are: 1. Develop and maintain of unique nuclear testing infrastructure, which includes test reactors, hot cell PIE equipment, and unique out of pile separate effects testing facilities. 2. Respond directly to industry requests for support by partnering with the ATF vendors and executing experiments and/or analysis on their behalf. 3. Conduct independent scientific investigations into the performance of the different ATF concepts that are relevant to Industry designs. To achieve these objectives, the safety research program will execute transient irradiation experiments at the TREAT facility at Idaho National Laboratory with the aim of identifying the relevant transient fuel behaviors for each fuel design in order to establish appropriate fuel safety criteria and thresholds. Two test series are described in this plan, (1) an Integral Test Series, and (2) a Focused Effects Test Series. In fulfillment of the first objective for the safety research program, Integral Effects Tests will be developed and demonstrated using standard UO2 Zircaloy fuel designs in both the fresh and previously irradiated case. The Integral Test Series will consist of three campaigns to evaluate transient fuel performance in Reactivity Initiated Accidents, Loss of Coolant Accidents, and in generalized Power Cooling Mismatch scenarios. Development of these test programs also enables the safety research program to fulfill its second objective by making these three test programs available to each industry team. Initially, priority will be given in the integral test series to the coated cladding and doped fuel concepts as their deployment schedule is the most aggressive. To fulfill the third objective of the safety research program, a Focused Effects Test Series is also being developed which will examine specific transient fuel behaviors that are of general interest to all the ATF designs under development. These tests look at transient fuel behavior related to pellet cladding mechanical interaction, coated cladding swelling, rupture, and time at temperature behavior, non oxide fuel melting and mechanical interaction with Silicon Carbide cladding, UO2 and doped UO2 fuel fragmentation and transient fission gas release, and finally fuel coolant interaction. This document provides a general overview of the objectives of the safety research program as well as providing background into how programs like this have been used in the past to develop the criteria necessary for the safe operation of the present fuel designs. An overview of the materials and methods used for safety testing is presented. Finally the Integral and Focused Effects tests series are introduced and described. This document will be maintained as a “living” document with annual updates to reflect evolving requirements and needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Post-irradiation examination of AGR-3/4 TRISO fuel compacts using three-dimensional X-ray computed tomography

The AGR-3/4 irradiation tests combined the third and fourth planned irradiation experiments in the US Department of Energy’s Advanced Gas Reactor (AGR) testing campaign of tri-structural isotropic (TRISO) fuel compacts. In this article, we present post-irradiation examination (PIE) using X-ray computed tomography (XCT) of two unirradiated and two irradiated compacts from the AGR-3/4 irradiation tests. The irradiated compacts studied (compact 7–1 and compact 12–4) represent the upper and lower limit of burnup within the AGR-3/4 irradiation experiment. This article presents a detailed quantitative analysis on the post-irradiation structure of TRISO fuel compacts. Various quantitative parameters including shape, size, and packing of kernels, and their spatial distribution, were utilized to gain insights into the structural changes caused by irradiation. The equivalent diameter and sphericity were found to increase and decrease, respectively, in irradiated compact 7–1 due to its higher burnup. Nearest neighbor distance between fuel kernels decreased after irradiation, suggesting irradiation-induced shrinkage of graphitic matrix. Furthermore, each compact in AGR-3/4 irradiation tests contained 20 designed-to-fail (DTF) fuel particles that were meant to act as a source of fission product release to the experiment test train. Furthermore, in the present work, all DTF fuel particles in the four compacts studied were identified, and it was found that they exhibited larger kernel swelling in compact 12–4 and smaller kernel swelling in compact 7–1, compared to the driver particles.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Depleted-Uranium Strength and Damage Behavior

The intent of this report is to document the status of our knowledge of the mechanical and damage behavior of Depleted Uranium(DU hereafter). This report briefly summaries the motivation of the experimental and modeling research conducted at Los Alamos National Laboratory(LANL) on DU since the early 1980’s and thereafter the current experimental data quantifying the strength and damage behavior of DU as a function of a number of experimental variables including processing, strain rate, temperature, stress state, and shock prestraining. The effect of shock prestraining on the structure-property response of DU is described and the effect on post-shock mechanical behavior of DU is discussed. The constitutive experimental data utilized to support the derivation of two constitutive strength (plasticity) models, the Preston-Tonks-Wallace (PTW) and Mechanical Threshold Stress (MTS) models, for both annealed and shock prestrained DU are detailed and the Taylor cylinder validation tests and finite-element modeling (FEM) utilized to validate these strength models is discussed. The similarities and differences in the PTW and MTS model descriptions for DU are discussed for both the annealed and shock prestrained conditions. Quasi-static tensile data as a function of triaxial constraint and spallation test data are described. An appendix additionally briefly describes low-pressure equation-of-state data for DU utilized to support the spallation experiments. The constitutive behavior of DU screw/bolt material is presented. The response of DU subjected to dynamic tensile extrusion testing as a function of temperature is also described. This integrated experimental technique is planned to provide an additional validation test in the future. The damage data as a function of triaxiality, tensile and spallation data, is thereafter utilized to support derivation of the Tensile Plasticity (TEPLA) damage model and simulations for comparison to the DU spallation data are presented. Finally, a discussion of future needs in the area of needed DU strength and damage research at LANL is presented to support the development of physically-based predictive strength and damage modeling capability.

36 MATERIALS SCIENCE↗

Developing the Irradiation Plan for U-10Mo LEU Fuel Qualification for the Advanced Test Reactor

The Department of Energy (DOE), National Nuclear Security Administration’s Office of Material Management and Minimization (M3) mission is to convert, remove, and dispose of vulnerable nuclear material located at civilian sites worldwide. As part of its mission, M3’s Office of Convert works around the world to convert research reactors and isotope production facilities to non-weapon-usable nuclear material, both domestically and abroad. In support of this, the Office of Convert is working with the Idaho National Laboratory (INL) to develop and qualify new fuels and technologies to support conversion efforts domestically and abroad. The INL also supports the Office of Convert by working on converting the Advanced Test Reactor (ATR) and the Advanced Test Reactor Critical (ATRC) from using High Enriched Uranium (HEU) fuel to Low Enriched Uranium (LEU) fuel. To ensure the viability of ATR LEU fuel, the fuel system should meet a similar functional and operational envelope as the current HEU fuel. A series of irradiation tests of the U-10Mo LEU fuel system is required to support the qualification of the fuel system for use in the ATR and several other U.S. High-Performance Research Reactors (USHPRRs). These irradiation tests include: • Mini-Plate tests (MP-1, MP-2, and MP-ATR), • Full-Size Plate tests (FSP-1, and FSP-ATR), and • Element Tests (ET-1, ET-2, and ET-3). The MP tests will use multiple small-scale samples that will provide sufficient data across a wide variety of irradiation conditions to qualify the fuel. The FSP tests will use a small number of full-sized fuel plates to confirm the MP test results are representative of the prototypic plate geometry performance. The MP and FSP irradiation tests occur in ATR test locations. The ETs will use full-sized fuel elements located in ATR core driver positions to explore the full operating ranges of the ATR and other USHPRRs and to confirm that the MP and FSP test results are representative of the prototypic element geometry performance. The established testing functional and operational requirements of MP-1, MP-2, FSP-1, and ET 1 achieve the base fuel qualification needs of the USHPRRs, while the high-level purposes of MP-ATR, FSP ATR, ET 2, and ET-3 are focused on demonstrating U-10Mo fuel for ATR use.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DOE Hanford Network Upgrades and Disaster Recovery Exercise Support the Cleanup Mission Now and into the Future

In 2013, the U.S. Department of Energy's (DOE) Hanford Site, located in Washington State, funded an update to the critical network infrastructure supporting the Hanford Federal Cloud (HFC). The project, called ET-50, was the final step in a plan that was initiated five years ago called "Hanford's IT Vision, 2015 and Beyond." The ET-50 project upgraded Hanford's core data center switches and routers along with a majority of the distribution layer switches. The upgrades allowed HFC the network intelligence to provide Hanford with a more reliable and resilient network architecture. The culmination of the five year plan improved network intelligence and high performance computing as well as helped to provide 10 Gbps capable links between core backbone devices (10 times the previous bandwidth). These improvements allow Hanford the ability to further support bandwidth intense applications, such as video teleconferencing. The ET-50 switch upgrade, along with other upgrades implemented from the five year plan, have prepared Hanford's network for the next evolution of technology in voice, video, and data. Hand-in-hand with ET-50's major data center outage, Mission Support Alliance's (MSA) Information Management (IM) organization executed a disaster recovery (DR) exercise to perform a true integration test and capability study. The DR scope was planned within the constraints of ET-50's 14 hour datacenter outage window. This DR exercise tested Hanford's Continuity of Operations (COOP) capability and failover plans for safety and business critical Hanford Federal Cloud applications. The planned suite of services to be tested was identified prior to the outage and plans were prepared to test the services ability to failover from the primary Hanford data center to the backup data center. The services tested were: Core Network (backbone, firewall, load balancers); Voicemail; Voice over IP (VoIP); Emergency Notification; Virtual desktops; and, Select set of production applications and data. The primary objective of the exercise was to test COOP around the emergency operations at Hanford to provide information on capabilities and dependencies of the current system to insure improved focus of emergency, safety and security capacity in a disaster situation. The integration of the DR test into the ET-50 project allowed the testing of COOP at Hanford and allowed the lessons learned to be defined. These lessons learned have helped improve the understanding of Hanford's COOP capabilities and will be critical for future planning. With the completion of the Hanford Federal Cloud network upgrades and the disaster recovery exercise, the MSA has a clearer path forward for future technology implementations as well as network improvements to help shape the usability and reliability of the Hanford network in support of the cleanup mission.

97 MATHEMATICS AND COMPUTING↗

Commissioning of intensity modulated neutron radiotherapy (IMNRT)

Purpose: Intensity modulated neutron radiotherapy (IMNRT) has been developed using inhouse treatment planning and delivery systems at the Karmanos Cancer Center/Wayne State University Fast Neutron Therapy facility. The process of commissioning IMNRT for clinical use is presented here. Results of commissioning tests are provided including validation measurements using representative patient plans as well as those from the TG-119 test suite. Methods: IMNRT plans were created using the Varian Eclipse optimization algorithm and an inhouse planning system for calculation of neutron dose distributions. Tissue equivalent ionization chambers and an ionization chamber array were used for point dose and planar dose distribution comparisons with calculated values. Validation plans were delivered to water and virtual water phantoms using TG-119 measurement points and evaluation techniques. Photon and neutron doses were evaluated both inside and outside the target volume for a typical IMNRT plan to determine effects of intensity modulation on the photon dose component. Monitor unit linearity and effects of beam current and gantry angle on output were investigated, and an independent validation of neutron dosimetry was obtained. Results: While IMNRT plan quality is superior to conventional fast neutron therapy plans for clinical sites such as prostate and head and neck, it is inferior to photon IMRT for most TG-119 planning goals, particularly for complex cases. This results significantly from current limitations on the number of segments. Measured and calculated doses for 11 representative plans (six prostate/five head and neck) agreed to within -0.8 {+-} 1.4% and 5.0 {+-} 6.0% within and outside the target, respectively. Nearly all (22/24) ion chamber point measurements in the two phantom arrangements were within the respective confidence intervals for the quantity [(measured-planned)/prescription dose] derived in TG-119. Mean differences for all measurements were 0.5% (max = 7.0%) and 1.4% (max = 4.1%) in water and virtual water, respectively. The mean gamma pass rate for all cases was 92.8% (min = 88.6%). These pass rates are lower than typically achieved with photon IMRT, warranting development of a planar dosimetry system designed specifically for IMNRT and/or the improvement of neutron beam modeling in the penumbral region. The fractional photon dose component did not change significantly in a typical IMNRT plan versus a conventional fast neutron therapy plan, and IMNRT delivery is not expected to significantly alter the RBE. All other commissioning results were considered satisfactory for clinical implementation of IMNRT, including the external neutron dose validation, which agreed with the predicted neutron dose to within 1%. Conclusions: IMNRT has been successfully commissioned for clinical use. While current plan quality is inferior to photon IMRT, it is superior to conventional fast neutron therapy. Ion chamber validation results for IMNRT commissioning are also comparable to those typically achieved with photon IMRT. Gamma pass rates for planar dose distributions are lower than typically observed for photon IMRT but may be improved with improved planar dosimetry equipment and beam modeling techniques. In the meantime, patient-specific quality assurance measurements should rely more heavily on point dose measurements with tissue equivalent ionization chambers. No significant technical impediments are anticipated in the clinical implementation of IMNRT as described here.

60 APPLIED LIFE SCIENCES↗

Development of an Integrated System for the Long-term Preservation of Records, Knowledge and Memory relating to Radioactive Waste Disposal Facilities - 17099

The Nuclear Energy Agency (NEA) has co-ordinated an international initiative to develop a common approach to the preservation of records, knowledge and long-term memory (RK and M), focused on radioactive waste disposals. The work programme has run in two phases, starting in 2011, with the current phase of the project due to be completed in 2018. Preparations for final reporting are now underway. The detailed implementation of an approach to RK and M preservation for any disposal facility will always remain a national decision. However, the NEA project has produced a 'menu' of tools and techniques that can be accessed and adapted to suit national needs. The common source of these menu components will help to ensure that the memory of the repository is kept alive, that messages to future populations can be clearly understood, and that evidence derived from the disposal environment can be properly interpreted. This paper describes the vision for implementation of the RK and M initiative within national programmes. Practical testing of some components of the menu of tools and techniques is currently underway in France, Sweden and USA, with encouraging results. Other disposal facilities, both under development or in planning, are invited to 'road test' the products and provide feedback. Refinement and maintenance of the tools remains important, and the NEA is committed to ensuring the continued accessibility and availability of the project outputs into the future. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrective Action Investigation Plan for Corrective Action Unit 570: Area 9 Yucca Flat Atmospheric Test Sites Nevada National Security Site, Nevada, Revision 0

CAU 570 comprises the following six corrective action sites (CASs): • 02-23-07, Atmospheric Test Site - Tesla • 09-23-10, Atmospheric Test Site T-9 • 09-23-11, Atmospheric Test Site S-9G • 09-23-14, Atmospheric Test Site - Rushmore • 09-23-15, Eagle Contamination Area • 09-99-01, Atmospheric Test Site B-9A These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on April 30, 2012, by representatives of the Nevada Division of Environmental Protection and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 570. The site investigation process will also be conducted in accordance with the Soils Activity Quality Assurance Plan, which establishes requirements, technical planning, and general quality practices to be applied to this activity. The presence and nature of contamination at CAU 570 will be evaluated based on information collected from a field investigation. Radiological contamination will be evaluated based on a comparison of the total effective dose at sample locations to the dose-based final action level. The total effective dose will be calculated as the total of separate estimates of internal and external dose. Results from the analysis of soil samples will be used to calculate internal radiological dose. Thermoluminescent dosimeters placed near the center of each sample location will be used to measure external radiological dose. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS.

54 ENVIRONMENTAL SCIENCES↗

WE-H-BRC-06: A Unified Machine-Learning Based Probabilistic Model for Automated Anomaly Detection in the Treatment Plan Data

Purpose: The purpose of this work was to investigate the ability of a machine-learning based probabilistic approach to detect radiotherapy treatment plan anomalies given initial disease classes information. Methods In total we obtained 1112 unique treatment plans with five plan parameters and disease information from a Mosaiq treatment management system database for use in the study. The plan parameters include prescription dose, fractions, fields, modality and techniques. The disease information includes disease site, and T, M and N disease stages. A Bayesian network method was employed to model the probabilistic relationships between tumor disease information, plan parameters and an anomaly flag. A Bayesian learning method with Dirichlet prior was useed to learn the joint probabilities between dependent variables in error-free plan data and data with artificially induced anomalies. In the study, we randomly sampled data with anomaly in a specified anomaly space.We tested the approach with three groups of plan anomalies – improper concurrence of values of all five plan parameters and values of any two out of five parameters, and all single plan parameter value anomalies. Totally, 16 types of plan anomalies were covered by the study. For each type, we trained an individual Bayesian network. Results: We found that the true positive rate (recall) and positive predictive value (precision) to detect concurrence anomalies of five plan parameters in new patient cases were 94.45±0.26% and 93.76±0.39% respectively. To detect other 15 types of plan anomalies, the average recall and precision were 93.61±2.57% and 93.78±3.54% respectively. The computation time to detect the plan anomaly of each type in a new plan is ∼0.08 seconds. Conclusion: The proposed method for treatment plan anomaly detection was found effective in the initial tests. The results suggest that this type of models could be applied to develop plan anomaly detection tools to assist manual and automated plan checks. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

Permanganate Oxidation of Defense Waste Processing Facility (DWPF) Recycle Collection Tank (RCT) Simulants Larger Scale Protocol Runs - Chemical Process Cell (CPC) Nominal and Foamover Conditions

Testing to develop a process to oxidize glycolate and other organic species in non-radioactive waste simulants was requested by Savannah River Remediation (SRR). A Task Technical and Quality Assurance Plan (TTQAP) was written to describe the testing requested by SRR in the development of a process to oxidize glycolate and other organic species that are responsible for hydrogen generation from thermolysis. Scoping studies have been completed as requested by a Technical Assistance Request (TAR) to evaluate the feasibility of using sodium permanganate and Fenton's Reagent (iron catalyzed hydrogen peroxide) for destroying glycolate. The results from these scoping studies were summarized in a report. Six phases of tests with simulants have been planned in developing an oxidation flowsheet for the Recycle Collection Tank (RCT), as shown in Table 1. The first three phases have been completed. The first phase comprised of scoping tests of permanganate and Fenton's reagent. The second phase was a matrix of 23 tests completed to inform a down-select decision by SRR and to complete testing needed to understand the influence of various factors in defining the optimum processing conditions for oxidation of organics. From the results of this testing, oxidation by permanganate was chosen over Fenton's reagent with hydrogen peroxide. The third phase of testing was to demonstrate nominal operation of the permanganate oxidation process under protocols similar to those used in the Defense Waste Processing Facility (DWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-C-BRB-04: Characteristics and Performance Evaluation of the First Commercial MLC for a Robotic Delivery System

Purpose: To assess characteristics and performance of the “Incise™” MLC (41 leaf pairs, 2.5mm width, FFF linac) mounted on the robotic SRS/SBRT platform “CyberKnife M6™” in a pre-clinical 5 months (11/2014–03/2015) test period. Methods: Beam properties were measured with unshielded diodes and EBT3 film. The CyberKnife workspace for MLC was analyzed by transforming robot node coordinates (cranial / body paths) into Euler geometry. Bayouth tests for leaf / bank position accuracy were performed in standard (A/P) and clinically relevant non-standard positions, before and after exercising the MLC for 10+ minutes. Total system and delivery accuracy were assessed in End-to-End tests and dosimetric verification of exemplary plans. Stability over time was evaluated in Picket-Fence-and adapted Winston-Lutz-tests (AQA) for different collimator angles. Results: Penumbrae (80–20%, with 100%=2*dose at inflection point; SAD 80cm; 10cm depth) parallel / perpendicular to leaf motion were 2.87/2.64mm for the smallest (0×76×0.75cm{sup 2}) and 5.34/4.94mm for the largest (9.76×9.75cm{sup 2}) square field. MLC circular field penumbrae exceeded fixed cones by 10–20% (e.g. 60mm: 4.0 vs. 3.6mm; 20mm: 3.6 vs. 2.9mm). Interleaf leakage was <0.5%. Clinically accessible workspace with MLC covered (non-coplanar) gantry angles of [-113°;+112°] (cranial) and [-108°;+102°] (body), and collimator angles of [-100°;+107°] (cranial) and [-91°;+100°] (body). Average leaf position offsets were ≤0.2mm in 14 standard A/P Bayouth tests and ≤0.6mm in 8 non-standard direction tests. Pre-test MLC exercise increased jaggedness (range ±0.3mm vs. ±0.5mm) and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.39±0.06mm in 6 End-to-End tests. Picket-Fence and AQA showed no adverse trends during the test period. Conclusion: The Incise™ MLC for CyberKnife M6™ displayed high accuracy and mechanical stability over the test period. The specific CyberKnife geometry and performance after exercise demand dedicated QA measures. This work is in part funded by a research grant from Accuray Inc, Sunnyvale, USA. Erasmus MC Cancer Institute also has research collaborations with Elekta AB, Stockholm, Sweden. C Fuerweger has previously received speaker honoraria from Accuray Inc, Sunnyvale, USA.

60 APPLIED LIFE SCIENCES↗

WE-AB-209-05: Development of an Ultra-Fast High Quality Whole Breast Radiotherapy Treatment Planning System

Purpose: To enable near-real-time (<20sec) and interactive planning without compromising quality for whole breast RT treatment planning using tangential fields. Methods: Whole breast RT plans from 20 patients treated with single energy (SE, 6MV, 10 patients) or mixed energy (ME, 6/15MV, 10 patients) were randomly selected for model training. Additional 20 cases were used as validation cohort. The planning process for a new case consists of three fully automated steps:1. Energy Selection. A classification model automatically selects energy level. To build the energy selection model, principle component analysis (PCA) was applied to the digital reconstructed radiographs (DRRs) of training cases to extract anatomy-energy relationship.2. Fluence Estimation. Once energy is selected, a random forest (RF) model generates the initial fluence. This model summarizes the relationship between patient anatomy’s shape based features and the output fluence. 3. Fluence Fine-tuning. This step balances the overall dose contribution throughout the whole breast tissue by automatically selecting reference points and applying centrality correction. Fine-tuning works at beamlet-level until the dose distribution meets clinical objectives. Prior to finalization, physicians can also make patient-specific trade-offs between target coverage and high-dose volumes.The proposed method was validated by comparing auto-plans with manually generated clinical-plans using Wilcoxon Signed-Rank test. Results: In 19/20 cases the model suggested the same energy combination as clinical-plans. The target volume coverage V100% was 78.1±4.7% for auto-plans, and 79.3±4.8% for clinical-plans (p=0.12). Volumes receiving 105% Rx were 69.2±78.0cc for auto-plans compared to 83.9±87.2cc for clinical-plans (p=0.13). The mean V10Gy, V20Gy of the ipsilateral lung was 24.4±6.7%, 18.6±6.0% for auto plans and 24.6±6.7%, 18.9±6.1% for clinical-plans (p=0.04, <0.001). Total computational time for auto-plans was < 20s. Conclusion: We developed an automated method that generates breast radiotherapy plans with accurate energy selection, similar target volume coverage, reduced hotspot volumes, and significant reduction in planning time, allowing for near-real-time planning.

60 APPLIED LIFE SCIENCES↗