Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results and planned experiments with the INFN-LNS ray-tracing magnetic spectrometer MAGNEX

The MAGNEX large-acceptance ray-tracing magnetic spectrometer has recently been used with beams from the INFN-LNS Tandem accelerator. After an accurate commissioning, the instrument has started an ambitious experimental program. In the first experiment the {sup 19}F({sup 7}Li,{sup 7}Be){sup 19}O charge-exchange reaction was studied at 52 MeV incident energy. The {sup 19}O excitation energy spectrum was reconstructed and the angular distributions measured. The second experiment was aimed at the study of the {sup 15}C via the {sup 13}C({sup 18}O,{sup 16}O){sup 15}C reaction at 84 MeV incident energy. The ejectiles where detected at forward angles and mass identified by means of an innovative technique. The {sup 15}C excitation energy spectra up to about 20 MeV were obtained with a 250 keV FWHM energy resolution. In addition to several known states, the spectra show two unknown resonant-like structures at 11.4 and 14.0 MeV. The strong population of these structures, together with the measured widths, could indicate the collective nature of these states associated to a correlated neutron pair transfer. Besides the first results of physical interest from these two experiments, future experiments with MAGNEX are briefly outlined.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Full Hemisphere Fermi Surface Mapping Using A Novel Toroidal Electron Spectrometer

An overview is provided of a next-generation toroidal angle-resolving photoemission spectrometer, currently in operation at BESSY II. The instrument features exceptional multi-detection in energy and angle, facilitating rapid full-hemisphere photoemission measurements. The instrument is ideal for band structure and Fermi Surface (FS) mapping using Angle Resolved Photoemission Spectroscopy (ARPES). Recent full-hemisphere FS measurements of a prototypical material, copper, reveal previously unseen fine structure due to lifetime broadening, demonstrating the high angular resolution and dense {kappa}-space sampling capabilities of the instrument.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of electromagnetic processes with the dielectron spectrometer HADES

Dielectron production in pp and dp reactions at 1.25 A.GeV has been studied with the High Acceptance DiElectron Spectrometer (HADES) at GSI. Results obtained in inclusive and exclusive channels are shown, along with {pi}{sup +}, {pi}{sup -} and {eta} production in pp reactions at 1.25 and 2.2 GeV. Perspectives of experiments with {pi}{sup -} beams are outlined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inclusive meson production in 3.5 GeV pp collisions studied with the HADES spectrometer

We present the inclusive di-electron invariant-mass spectrum from p+p interactions at 3.5 GeV kinetic beam energy. It is a very important reference for the study of vector meson production off the nucleus, recently investigated by HADES in p+{sup 93}Nb reactions at the same beam energy. Up to invariant masses of 0.6 GeV/c{sup 2} the main contributions to the e{sup +}e{sup -} spectrum are {pi}{sup 0},{eta}, {omega} and {Delta} Dalitz decays. In the vector-meson region a clear peak corresponding to the {omega} direct decay is reconstructed with {approx_equal}2% mass resolution. Subtracting this peak from the spectrum allows to investigate additional sources, in particular the {rho} meson. Indeed, the latest results from HSD and UrQMD calculations show different distributions for the shape of the {rho} meson at these energies. Therefore it is important to experimentally understand the production mechanism of the {rho} meson in elementary reactions. Besides the spectral shape of the mesons, their inclusive production cross sections are also not known at these energies. Due to the large and flat acceptance of the HADES spectrometer for e{sup +}e{sup -} masses above 0.2 GeV/c{sup 2} and for P{sub T}<1GeV/c, acceptance corrections are to a large extent model independent. This allows us to extract the preliminary inclusive cross section values for the meson productions at these energies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use Of The BigSol Time Of Flight Spectrometer In The Study Of Superheavy Element Production

A time-of-flight spectrometer with the BigSol superconducting solenoid at Texas A and M was used to investigate the possibility to produce heavy and superheavy nuclei by using two body collisions involving heavy projectiles and targets. The reaction {sup 197}Au+{sup 232}Th at 7.5 AMeV is studied in this work. Preliminary results for the yields of heavy nuclei are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fully digital data acquisition system for the neutron time-of-flight spectrometer TOFOR at JET

A prototype of a fully digital data acquisition system based on 1 Gsps 12 bit digitizers for the TOFOR fusion neutron spectrometer at JET is assessed. The prototype system enables the use of geometry-based background discrimination techniques, which are modeled, evaluated, and compared to experimental data. The experimental results are in line with the models and show a significant improvement in signal-to-background ratio in measured time-of-flight spectrum compared to the existing data acquisition system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined inclusive diffractive cross sections measured with forward proton spectrometers at HERA

A combination is presented of the inclusive diffractive cross section measurements made by the H1 and ZEUS Collaborations at HERA. The analysis uses samples of diffractive deep inelastic scattering data where leading protons are detected by dedicated spectrometers. Correlations of systematic uncertainties are taken into account by the combination method, resulting in improved precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Second generation fusion neutron time-of-flight spectrometer at optimized rate for fully digital data acquisition

The progress on high-rate event recording of data is taken as starting point to revisit the design of fusion neutron spectrometers based on the TOF (time-of-flight) technique. The study performed was aimed at how such instruments for optimized rate (TOFOR) can be further developed to enhance the plasma diagnostic capabilities based on measurement of the 2.5 MeV dd neutron emission from D plasmas, especially the weak spectral components that depend on discrimination of extraneous events. This paper describes a design (TOFOR II) adapted for use with digital wave form recording of all detector pulses providing information on both amplitude (pulse height) and timing. The results of simulations are presented and the performance enhancement is assessed in comparison to the present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer

A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity-space sensitivity of the time-of-flight neutron spectrometer at JET

The velocity-space sensitivities of fast-ion diagnostics are often described by so-called weight functions. Recently, we formulated weight functions showing the velocity-space sensitivity of the often dominant beam-target part of neutron energy spectra. These weight functions for neutron emission spectrometry (NES) are independent of the particular NES diagnostic. Here we apply these NES weight functions to the time-of-flight spectrometer TOFOR at JET. By taking the instrumental response function of TOFOR into account, we calculate time-of-flight NES weight functions that enable us to directly determine the velocity-space sensitivity of a given part of a measured time-of-flight spectrum from TOFOR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuterium density profile determination at JET using a neutron camera and a neutron spectrometer

In this work we estimate the fuel ion density profile in deuterium plasmas at JET, using the JET neutron camera, the neutron time-of-flight spectrometer TOFOR, and fusion reactivities modeled by the transport code TRANSP. The framework has been tested using synthetic data, which showed that the density profile could be reconstructed with an average accuracy of the order of 10 %. The method has also been applied to neutron measurements from a neutral beam heated JET discharge, which gave n{sub d}/n{sub e} ≈ 0.6 ± 0.3 in the plasma core and n{sub d}/n{sub e} ≈ 0.4 ± 0.3 towards the edge. Correction factors for detector efficiencies, neutron attenuation, and back-scattering are not yet included in the analysis; future work will aim at refining the estimated density.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radial collimator for a time-of-flight neutron spectrometer

We have engineered and installed a radial collimator for use in the scattered beam of a neutron time-of-flight spectrometer at a spallation neutron source. The radial collimator may be used with both thermal and epithermal neutrons, reducing the detected scattering intensity due to material outside of the sample region substantially. The collimator is located inside of the sample chamber of the instrument, which routinely cycles between atmospheric conditions and cryogenic vacuum. The oscillation and support mechanism of the collimator allow it to be removed from use without breaking vacuum. We describe here the design and characterization of this radial collimator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the {sup 63-66}Fe and {sup 64-67}Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for {sup 66}Fe and {sup 67}Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of {sup 65}Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in {sup 67}Co is confirmed. Relative mass uncertainties as low as 4x10{sup -8} are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of {sup 64}Co, where a 5sigma deviation is observed. Using these data the two neutron separation energies S{sub 2n} are calculated. However, the large error bars in the mass values of the neighbor Fe and Co isotopes with N>40 complicate the validation of a weak subshell closure at N=40 for the Co isotopes or the possible reduction in the neutron shell gap in the case of the Fe isotopes, in accordance with the theoretical predictions of an onset of deformation in the region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Convergence Studies of Thermal and Electromagnetic Transient Quench Analysis of 11 GeV Super High Momentum Spectrometer Superconducting Magnets in Jefferson Lab

This paper presents results of convergence studies of transient thermal and electromagnetic quench analysis of five Super High Momentum Spectrometer (SHMS) superconducting magnets: HB, Q1, Q2, Q3, and Dipole, using Vector Fields Quench analysis codes. The convergence of the hot spot temperature and solution solve times were used to investigate the effects of element types, mesh densities, and tolerance criteria. The comparisons between tetrahedral elements and hexahedral elements was studied, and their advantages and disadvantages were discussed. Based on the results of convergence studies, a meshing guideline for coils is presented. The impact of iteration tolerance to the hot spot temperature was also explored, and it is found that tight tolerances result in extremely long solve times with only marginal improvements in the results.

43 PARTICLE ACCELERATORS↗

Development of a Silicon Drift Detector Array: An X-ray Fluorescence Spectrometer for Remote Surface Mapping

Over the past three years NASA Marshall Space Flight Center has been collaborating with Brookhaven National Laboratory to develop a modular Silicon Drift Detector (SDD) X-Ray Spectrometer (XRS) intended for fine surface mapping of the light elements of the moon. The value of fluorescence spectrometry for surface element mapping is underlined by the fact that the technique has recently been employed by three lunar orbiter missions; Kaguya, Chandrayaan-1, and Chang'e. The SDD-XRS instrument we have been developing can operate at a low energy threshold (i.e. is capable of detecting Carbon), comparable energy resolution to Kaguya (<150 eV at 5.9 keV) and an order of magnitude lower power requirement, making much higher sensitivities possible. Furthermore, the intrinsic radiation resistance of the SDD makes it useful even in radiation-harsh environments such as that of Jupiter and its surrounding moons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial studies of the gamma resonance of the {sup 109m}Ag isomer with a gravitational gamma spectrometer

The problem of observing the Moessbauer resonance absorption of gamma rays from long-lived isomers is briefly outlined, first and foremost for {sup 109m}Ag taken as an example. Experiments indicative of a small broadening of the Moessbauer gamma line of this isomer in metallic silver are described. This circumstance made it possible to develop and manufacture a gravitational gamma spectrometer and to perform the first experiments with it, which confirm once again the previous data on a small width of the gamma line in question. The broadening factor obtained from these data proved to be 6.3{sub -1.9}{sup +5.2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of a Portable, Battery-Powered Quadrupole Mass Spectrometer for Real-Time Sampling of Materials

We have designed and constructed a low cost, portable, battery-powered quadrupole mass spectrometer for use in the materials analysis of gaseous, liquid or solid field samples. The system may be configured for continuous sampling of ambient gas samples, or for the analysis of small solid, liquid or gas samples in sealed glass vials. The system is capable of measuring partial pressures down to the 10<-10> Torr range, and may be operated on battery power for several hours in a field deployment. Information is presented on the specific design parameters and on the testing of the instrument. Preliminary results are reported for solid dinitrotoluene (DNT) and for chlorinated hydrocarbons and other contaminants in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗