Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “risk mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Synchronized Sensor Array for Remote Monitoring of Avian and Bat Interactions with Offshore Renewable Energy Facilities

Wind energy production in the U.S. is projected to increase to 35% of our nation’s energy by 2050. This substantial increase in the U.S. is only a portion of the global wind industry growth, as many countries strive to reduce greenhouse gas emissions. A major environmental concern and potential market barrier for expansion of wind energy is bird and bat mortality from impacts with turbine blades, towers, and nacelles. Carcass surveys are the standard protocol for quantifying mortality at onshore sites. This method is imperfect, however, due to survey frequency at remote sites, removal of carcasses by scavengers between surveys, searcher efficiency, and other biases as well as delays of days to weeks or more in obtaining information on collision events. Furthermore, carcass surveys are not feasible at offshore wind energy sites. Near-real-time detection and quantification of interaction rates is possible at both onshore and offshore wind facilities using an onboard, integrated sensor package with data transmitted to central processing centers. We developed and experimentally tested an array of sensors that continuously monitors for interactions (including impacts) of birds and bats with wind turbines. The synchronized array includes three sensor nodes: (1) vibration (accelerometers and contact microphones), (2) optical (visual and infrared spectrum cameras), and (3) bioacoustics (acoustic and ultrasonic microphones). Accelerometers and contact acoustic microphones are placed at the root of each blade to detect impact vibrations and sound waves propagating through the structure. On-board data processing algorithms using wavelet analysis detect impact signals exceeding background vibration. Stereo-visual and infrared cameras were placed on the nacelle to allow target tracking, distance, and size calculations. On-board image processing and target detection algorithms identify moving targets within the camera field of view. Bioacoustic recorders monitor vocalizations and echolocations to aid in identifying organisms involved in interactions. Data from all sensors are temporarily stored in ring (i.e., circular) buffers with a duration varying by sensor type. Detection of target presence or impact by any of the sensors can trigger the archiving of data from all buffers for transmission to a central data processing center for evaluation and post-processing. This mitigates the risk of “data mortgages” posed by continual recording and minimizes personnel time required to manually review event data. We first conducted individual component tests at laboratories and field sites in Corvallis and Newport, Oregon, and Seattle and Sequim, Washington. We conducted additional component tests on research wind turbines at the North American Wind Research and Training Center, Mesalands Community College (MCC; General Electric 1.5 MW turbine), New Mexico, and the National Wind Technology Center, National Renewable Energy Laboratory (NREL; Controls Advanced Research Turbines 3 [CART 3] 600 kW Westinghouse turbine), Colorado. We conducted fully integrated system tests at NREL in October 2014 and April 2015. We used only research wind turbines so that we could conduct controlled, experimentally generated impacts using empty and water-filled tennis balls shot from a compressed air cannon on the ground. The approx. 57-140 g tennis balls (depending on water content) were at the upper mass range for bats, but lower mass range for marine birds. Therefore, the ability to detect collisions of most seabirds is likely greater than our experiments demonstrate, but possibly lower for some bats depending on the background signal of a given turbine. Vibration data demonstrated that background signals of operating turbines varied markedly among the CART 3 under normal operation (greatest), GE (moderate), and CART 3 during idle rotation (generator not engaged; least). In total, we measured 63 experimental blade impacts on the two research turbines. Impaction detection was dependent on background signals, position of impact on the blade (a tip strike resulted in the strongest impact signal), and impact kinetics (velocity of ball and whether the ball struck the surface of the blade or the leading edge of the blade struck the ball). Overall detection percentage ranged from 100% for the “quietest” conditions (CART 3 idle rotation), down to 35% for the noisiest (CART 3 normal operation). Impact signals were detected from sensors on more than one blade (i.e., blades other than the blade struck) 50% - 75% of the time. Stereo imaging provided valuable metrics, but increased data processing and equipment cost. Given the cost of cameras with sufficient resolution for target identification, we suggest mounting cameras directly on the blades to continuously view the entire rotor swept area with the fewest number of cameras. Bioacoustic microphones provide taxonomic identification, as well as information on ambient noise levels. They also assist in identifying environmental conditions such as hail storms, high winds, thunder, lightning, etc., that may contribute to a collision or a false positive detection. We demonstrated a proof of concept for an integrated sensor array to detect and identify bird and bat collisions with wind turbines. The next phase of research and development for this system will miniaturize and integrate sensors from all three nodes into a single wireless package that can be attached directly to the blade. This next generation system would use all “smart” sensors capable of onboard data processing to drastically reduce data streams and processing time on a central computer. A provisional patent for the blade mounted system was submitted by Oregon State University and recorded by the U.S. Patent and Trademark Office (application no. 62313028). Eventually, technology and industry advances will allow this low cost monitoring system to be designed into materials during manufacturing so that all turbines could be monitored with either a subset or full suite of sensors. As standard equipment on all commercial turbines, the sensor suite would allow the industry to effectively monitor whether individual turbines were causing mortalities or not and under what circumstances. It would also provide real-time evaluation of mechanical and structural integrity of a turbine via vibration, image, and acoustic data streams, thereby permitting modifications in operation to limit environmental or mechanical damage.

17 WIND ENERGY↗

Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

High R-value wall assemblies (R-40 and above) are gaining popularity in the market due to programs such as the U.S. Department of Energy Zero Energy Ready Home program, Passive House, Net Zero Energy Home challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used double-wall systems to achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double-wall systems is that there are very few new exterior details. Exterior sheathings, structural bracings, house wraps or building paper, window and door flashings, and siding attachments are usually identical to good details in conventional framed-wall systems. However, although the details in double-wall systems are very similar to those in conventional stick framing, there is sometimes less room for error. Several studies have confirmed colder temperatures of exterior sheathing in high R-value wall assemblies that do not have exterior rigid foam insulation. These colder temperatures can lead to increased chances for condensation from air exfiltration, and they have the potential to result in moisture-related problems (Straube and Smegal 2009, Arena 2014, Ueno 2015). The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and reduce material brought to landfills due to failures and resulting decay. Although this document focuses on double-wall framing techniques, the majority of the information about how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture-related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super-insulated homes. The information is applicable to both new construction and gut-rehabilitation projects in Climate Zones 5 and higher.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrothermal Liquefaction and Upgrading of Municipal Wastewater Treatment Plant Sludge: A Preliminary Techno-Economic Analysis, Rev.1

A preliminary process model and techno-economic analysis (TEA) was completed for fuel produced from hydrothermal liquefaction (HTL) of sludge waste from a municipal wastewater treatment plant (WWTP) and subsequent biocrude upgrading. The model is adapted from previous work by Jones et al. (2014) for algae HTL, using experimental data generated in fiscal year 2015 (FY15) bench-scale HTL testing of sludge waste streams. Testing was performed on sludge samples received from Metro Vancouver’s Annacis Island WWTP (Vancouver, B.C.) as part of a collaborative project with the Water Environment and Reuse Foundation (WERF). The full set of sludge HTL testing data from this effort will be documented in a separate report to be issued by WERF. This analysis is based on limited testing data and therefore should be considered preliminary. In addition, the testing was conducted with the goal of successful operation, and therefore does not represent an optimized process. Future refinements are necessary to improve the robustness of the model, including a cross-check of modeled biocrude components with the experimental GCMS data and investigation of equipment costs most appropriate at the relatively small scales used here. Environmental sustainability metrics analysis is also needed to understand the broader impact of this technology pathway. The base case scenario for the analysis consists of 10 HTL plants, each processing 100 dry U.S. ton/day (92.4 ton/day on a dry, ash-free basis) of sludge waste and producing 234 barrel per stream day (BPSD) biocrude, feeding into a centralized biocrude upgrading facility that produces 2,020 barrel per standard day of final fuel. This scale was chosen based upon initial wastewater treatment plant data collected by PNNL’s resource assessment team from the EPA’s Clean Watersheds Needs Survey database (EPA 2015a) and a rough estimate of what the potential sludge availability might be within a 100-mile radius. In addition, we received valuable feedback from the wastewater treatment industry as part of the WERF collaboration that helped form the basis for the selected HTL and upgrading plant scales and feedstock credit (current cost of disposal). It is assumed that the sludge is currently disposed of at $16.20/wet ton ($46/dry ton at 35% solids; $50/ton dry, ash-free basis) and this is included as a feedstock credit in the operating costs. The base case assumptions result in a minimum biocrude selling price of $3.8/gge and a minimum final upgraded fuel selling price of $4.9/gge. Several areas of process improvement and refinements to the analysis have the potential to significantly improve economics relative to the base case: •Optimization of HTL sludge feed solids content •Optimization of HTL biocrude yield •Optimization of HTL reactor liquid hourly space velocity (LHSV) •Optimization of fuel yield from hydrotreating •Combined large and small HTL scales specific to regions (e.g., metropolitan and suburban plants) Combined improvements believed to be achievable in these areas can potentially reduce the minimum selling price of biocrude and final upgraded fuel by about 50%. Further improvements may be possible through recovery of higher value components from the HTL aqueous phase, as being investigated under separate PNNL projects. Upgrading the biocrude at an existing petroleum refinery could also reduce the MFSP, although this option requires further testing to ensure compatibility and mitigation of risks to a refinery. And finally, recycling the HTL aqueous phase product stream back to the headworks of the WWTP (with no catalytic hydrothermal gasification treatment) can significantly reduce cost. This option is uniquely appropriate for application at a water treatment facility but also requires further investigation to determine any technical and economic challenges related to the extra chemical oxygen demand (COD) associated with the recycled water.

09 BIOMASS FUELS↗

Model-Based Extracted Water Desalination System for Carbon Sequestration

Over the last 1.5 years, GE Global Research and Pennsylvania State University defined a model-based, scalable, and multi-stage extracted water desalination system that yields clean water, concentrated brine, and, optionally, salt. The team explored saline brines that ranged across the expected range for extracted water for carbon sequestration reservoirs (40,000 up to 220,000 ppm total dissolved solids, TDS). In addition, the validated the system performance at pilot scale with field-sourced water using GE’s pre-pilot and lab facilities. This project encompassed four principal tasks, in addition to Project Management and Planning: 1) identify a deep saline formation carbon sequestration site and a partner that are suitable for supplying extracted water; 2) conduct a techno-economic assessment and down-selection of pre-treatment and desalination technologies to identify a cost-effective system for extracted water recovery; 3) validate the downselected processes at the lab/pre-pilot scale; and 4) define the scope of the pilot desalination project. Highlights from each task are described below: Deep saline formation characterization The deep saline formations associated with the five DOE NETL 1260 Phase 1 projects were characterized with respect to their mineralogy and formation water composition. Sources of high TDS feed water other than extracted water were explored for high TDS desalination applications, including unconventional oil and gas and seawater reverse osmosis concentrate. Technoeconomic analysis of desalination technologies Techno-economic evaluations of alternate brine concentration technologies, including humidification-dehumidification (HDH), membrane distillation (MD), forward osmosis (FO), turboexpander-freeze, solvent extraction and high pressure reverse osmosis (HPRO), were conducted. These technologies were evaluated against conventional falling film-mechanical vapor recompression (FF-MVR) as a baseline desalination process. Furthermore, a quality function deployment (QFD) method was used to compare alternate high TDS desalination technologies to FF-MVR. High pressure reverse osmosis was found to a be a promising alternative desalination technology. A deep-dive technoeconomic analysis of HPRO was performed, including Capex and Opex estimates, for seawater RO (SWRO). Additionally, two additional cases were explored: 1) a comparison of a SWRO plus HPRO system to the option of doubling the size of a standard seawater RO system to achieve the same total pure water recovery rate; and 2) a flue gas desulfurization wastewater treatment zero-liquid discharge (ZLD) application, where preconcentration with RO (SWRO or SWRO + HPRO) before evaporation and crystallization was compared to FF-MVR and crystallization technologies without RO preconcentration. Pre-pilot process validation Pre-pilot-scale tests were conducted using field production water to validate key process steps for extracted water pretreatment. Approximately 5,000 gallons of field produced water was processed through, microfiltration, ultrafiltration, and steam regenerable sorbent operations. Smaller quantities were processed through microclarification. In addition, analytical methods (purge-and-trap gas chromatography and Hach TOC analytical methods) were validated. Lab-scale HPRO elements were constructed and tested at high pressures, to identify and mitigate technical risks of the technology. Lastly, improvements in RO membrane materials were identified as the necessary next step to achieve further improvement in element performance at high pressure. Scope of Field Pilot A field pilot for extracted water pretreatment was designed.

20 FOSSIL-FUELED POWER PLANTS↗

HedgeHOGS: A Rapid Nuclear Hedge Sizing and Analysis Tool

The U.S. nuclear stockpile hedge is an inventory of non-deployed nuclear warheads and a force structure capable of deploying those warheads. Current guidance is to retain this hedge to mitigate the risk associated with the technical failure of any single warhead type or adverse geopolitical developments that could require augmentation of the force. The necessary size of the hedge depends on the composition of the nuclear stockpile and assumed constraints. Knowing the theoretical minimum hedge given certain constraints is useful when considering future weapons policy. HedgeHOGS, an Excel-based tool, was developed to enable rapid calculation of the minimum hedge size associated with varying active stockpile composition and hedging strategies.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Battery Deactivation by Electrochemically-Generated Inorganic Thin Films or Other Modifications to the External Casing

Every year in the U.S., more than 3,500 people of all ages swallow miniature disc, coin, or “button” batteries. In recent years, the number of reported battery ingestions has remained level yet the number of documented debilitating or fatal battery ingestions has increased. One particularly important approach to mitigate this risk is developing a solution that acts as the last line of defense: a solution that will prevent injury from accidentally swallowed batteries regardless if the ingestion is discovered or not. The primary objective of this project was to develop a solution that may render a coin cell harmless if it is swallowed. We explored a number of approaches toward this aim and found a composite organic/inorganic material that could be applied to a battery that allowed normal battery operation when dry and that would deactivate when wet. This collaboration between Sandia National Laboratories (SNL) and the Procter and Gamble Company (P&G), enabled by DOE facilities, allowed the development of a potentially simple but effective solution to the rare but horrific damage ingested batteries can do. This solution could have far-reaching effects due to the ubiquity of coin cells, and the potential impact is great for safer batteries that prevent debilitating injury and death.

36 MATERIALS SCIENCE↗

Best Practices for Operation and Maintenance of Photovoltaic and Energy Storage Systems; 3rd Edition

The goal of this guide is to reduce the cost and improve the effectiveness of operations and maintenance (O&M) for photovoltaic (PV) systems and combined PV and energy storage systems. Reported O&M costs vary widely based on the requirements of the system and the nature of the O&M contract, but a more standardized approach to planning and delivering O&M has the potential to both decrease costs and make those costs more predictable over time. This guide encourages adoption of best practices to reduce the cost of O&M and improve the performance of fielded systems, but it also enhances financing of new projects by making cost more predictable and mitigating performance risk. This guide also includes technical improvement opportunities in the design of systems and in specification of equipment because high-quality system deployment improves lifetime project performance and energy production while reducing, or at least optimizing, costs to deliver an O&M program. This guide provides recommendations that increase the effectiveness of O&M services; reduce O&M costs, improve solar asset transparency for investors and rating agencies; provide an industry framework for quality management; and reduce transaction costs.

14 SOLAR ENERGY↗

Alternate Design Concepts for the High Flux Isotope Reactor using Low-Enriched Uranium Fuel Systems: Scoping Analysis

The Oak Ridge National Laboratory (ORNL) High Flux Isotope Reactor (HFIR) is a multi-mission research reactor dedicated mainly to isotope production, neutron scattering experiments, material irradiation, testing and activation. In the framework of non-proliferation policies, the international community is currently aiming to reduce or even eliminate, when and where possible, the use of Highly Enriched Uranium (HEU: 235 U/U ≥ 20 wt. %) in civilian applications. In that context, most research reactors worldwide still operating with HEU fuel are actively engaged in an effort to convert to Low Enriched Uranium fuel system (LEU: 235 U/U < 20 wt. %). Within the US, the High Performance Research Reactor (USHPRR) fleet (which includes HFIR) is expected to convert to LEU fuel using the UMo “monolithic” fuel system currently under development. ORNL is responsible for the development of a LEU design for HFIR. In the past years, Argonne National Laboratory (ANL) offered technical assistance to the ORNL LEU design team whenever deemed appropriate. Due to their complex nature, acceptable HFIR LEU designs identified so far, all based on the UMo monolithic fuel system, would require a substantial fabrication development effort before being proven commercially viable. In order to mitigate technical risks and reduce cost/schedule uncertainties, it appears appropriate to study alternate design solutions and alternate fuel systems as possible backup options for the HFIR conversion to LEU fuel. In that context, ANL has been exploring alternate design concepts for HFIR. Complementing the ORNL design activities, the goal is to find the best design solution for HFIR in term of cost, performance and safety. The present report summarizes the findings regarding two types of alternate conceptual design: U 3 Si 2 designs and un-contoured UMo design. Based on available tools and methods, preliminary analysis show that both concepts could probably meet performance and steady-state safety requirements but element fabrication would remain complex and would require a non-trivial fabrication development effort.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Battery Deactivation by Electrochemically-Generated Short-Circuit

Every year in the U.S., more than 3,500 people of all ages swallow miniature disc, coin, or “button” batteries. In recent years the number of reported battery ingestions has remained level yet the number of documented debilitating or fatal battery ingestions has increased. One particularly important approach to mitigate this risk is developing a solution that will prevent injury from accidentally swallowed batteries regardless if the ingestion is discovered or not. The primary objectives of this project were to i) develop a solution that may render a coin cell harmless if it is swallowed and ii) develop a strategy to implement the solution that would be amenable to a high-throughput manufacturing process. To accomplish these objectives, Sandia refined a previously-identified approach toward this aim and found a composite organic/inorganic material that could be applied to a battery that allowed normal battery operation when dry and that would deactivate when wet. This coating formulation is amenable to straightforward deposition onto coin cells using direct-write or extrusion based approaches that benefited from some additional changes in the ink formulation. In summary, Sandia and Duracell, enabled by DOE facilities, developed an effective solution to the rare but horrific damage ingested batteries can do. This solution could have far-reaching effects due to the ubiquity of coin cells, and the potential impact is great for reducing debilitating injury and death caused by ingested coin cells.

Paxton, Walter↗

CarbonSAFE Rocky Mountain Phase I: Ensuring Safe Subsurface Storage of Carbon Dioxide in the Intermountain West

An integrated CCS pre-feasibility study, CarbonSAF E Rocky Mountain Phase I, was conducted by the U niversity of Utah and its partners as part of the US D epartment of Energy’s Carbon Storage Assurance a nd Facility Enterprise (CarbonSAFE) program. The a ssembled project team consisted of academic, indus try and governmental agencies covering the technic al and non- technical challenges of a commercial-sc ale CO 2 storage facility capable of storing 50 million tonnes of anthropogenically-sourced CO 2 . The Rock y Mountain CarbonSAFE team identified the Hunter Power Plant in central Utah as the primary source of CO 2 on which this study would be focused. The nea rby Huntington power plant, also operated by Rocky Mountain Power, was evaluated as a secondary sou rce of CO 2 . The Hunter plant was chosen because o f an interest in CO 2 capture technology by the plant operator, Rocky Mountain Power, and also because i t is a representative example of a typical coal-fired g enerating station in the Rocky Mountain west. Amine -based and cryogenic-based capture assessments w ere performed for approximately 3 million tonnes per year for one of the boiler units at the Hunter plant, yi elding cost of capture estimates of $\$56$/tonne and $\$4 1.50$/tonne. Transportation and intermediate compre ssion would increase the per tonne costs, but will be highly dependent on specific injection locations and available rights-of-way. A high-level technical sub-ba sinal evaluation was performed on the area surround ing the Hunter and Huntington power plants to verify CO 2 storage capacity and integrity. Initial geologic c haracterization efforts focused on sites immediately adjacent to the Hunter plant, including the deep eolia n Permian White Rim Sandstone, which in outcrop a nd core from other locations indicates high permeabi lity and high porosity. However, petrophysical logs fr om wells near Hunter indicate porosity of only 2-4%. As a result, potential injection sites were moved stru cturally down-dip (to the west), into the high permea bility (~200 mD) and high porosity (20%) Navajo san dstone. A comprehensive analysis of the reservoir a nd seals was conducted, providing data to the model , simulation and risk assessment groups on the proje ct. CO 2 capacity estimates for the Navajo Sandston e approximately 18 kilometers from the Hunter plant are well in excess of the 50 million tonnes goal of the project. Area of Review Delineation and Risk Asse ssment on the Navajo, associated seals and shallow groundwater aquifers identified the most significant risks and mitigation options. A non-technical assessment to a commercial-scale CO 2 storage facility in central Utah was conducted. EPA Underground Injection Control Class VI and National Environmental Policy Act permitting present particularly challenging issues related to the development of any saline aquifer for CO 2 storage, including the area around the Hunter plant. While surface and subsurface ownership and ri ghts are not straightforward, especially on any privat e land, many of the stakeholders in central Utah are accustomed and open to oil/gas/mineral-related activities similar to what would be required for CO 2 storage sites.

01 COAL, LIGNITE, AND PEAT↗

Rapid Carbon Fiber Prepreg Molding Technology for Automobile Structural Parts - "SEAHAWKS"

Carbon fiber reinforced plastics (CFRP) offer a variety of potential benefits to automotive parts vs. metals, mainly in the form of light-weighting, part consolidation, and corrosion resistance. However, complexities of composite manufacturing and lack of robust supply chain evolution and integration have hindered technological advancements to overcome high manufacturing costs, slow production rates and prolonged time to market. As a result, the use of CFRP in automotive structural parts has been limited to expensive “low to medium” volume platforms. The project overall investigates a concept of ecosystem-based composite manufacturing that enables rapid implementation of an integrated manufacturing system. Through partnering with individual organizations in the prepreg supply chain along with their respective technological advancements in materials, part designs, tool, equipment, recycling and repair, this project’s objective is to integrate these technologies into a manufacturing system through optimizing them individually and as a whole. Upon a successful delivery of a finished composite component to market, all associated technologies are evolved to production readiness levels not only individually but also in part of the integrated manufacturing system itself. Risks are mitigated effectively, as development costs and successes (and/or failures) are shared among all organizations. As a result, further cost reduction of the finished component is anticipated. Toray Composites (America) Inc. led the effort along with 13 other organizations to investigate and validate the concept. Phase I of this project via flat panel demonstrations focused on molding aspects of the integrated manufacturing system from several combinations of prepreg materials and molding methods used such as hydraulic press, RapidClave®, heated composite light tool (HCLT), light induction tool (LIT) and Quickstep. Other aspects such as automation equipment, recycling and component identification to further investigate and validate the concept via component demonstration in Phase II were also explored. It was found that several prepreg/process combinations could achieve a 3-6 min cure cycle time with panel thickness from 0.8 to 2.4 mm. This can be achieved under compaction pressure as low as vacuum, leading to composite panels that are void free, have good to excellent molded surfaces, Tg (by G’onset of DMA) ranging from 120-190 °C, and mechanical performance comparable to conventional autoclave cure.

36 MATERIALS SCIENCE↗

Preliminary IHE Qualification of a PATO/Viton-A Formulation: Shock-to-Detonation Experiments

All nuclear weapons in the stockpile require high explosive (HE) components to function. These explosives create safety hazards during storage, handling, and stockpile maintenance operations, where unintentional initiation can cause serious injuries, death, or significant damage to facilities and the environment. To mitigate these risks, the explosive formulation(s) used in these components should be as resistant to accidental initiation as possible. Mass-detonable explosives that are “so insensitive that the probability of accidental initiation or transition from burning to detonation is negligible” are defined by Chapter IX of the DOE Explosive Safety Standard as insensitive high explosives (IHE). The IHE in most common use in the DOE is currently PBX 9502 (95%wt TATB, 5%wt Kel-F800). The Los Alamos and Lawrence Livermore National Laboratories have established a series of experiments used to classify new HE formulations as either conventional HE (CHE) or IHE. This report describes three sets of gas gun experiments on a new candidate IHE formulation consisting of 95.5%wt 3-Picrylamino-1,2,4-Triazole (PATO) and 4.5%wt Viton-A. These experiments provide a preliminary evaluation of the performance of this material on the shock-to-detonation (SDT) portion of this qualification standard.

3-Picrylamino-1,2,4-Triazole↗

HPC for the EEC: Industrial Trade Tools for the Aging Energy Infrastructure

The petrochemical and refining sectors are challenged with reliably delivering safer and cleaner energy to US consumers, while meeting an ever-growing global demand. The petrochemical and refining infrastructure in the USA is aging, and corrosion and damage mechanisms are constant threats to mechanical integrity, safety, and profitability. However, governments and industry stakeholders are reluctant to replace or upgrade the existing infrastructure due to the immense cost. To better understand and mitigate the risks of aging energy infrastructure, strong technical analysis capabilities, combined with optimized monitoring and decision making, is critical. Today, this is accomplished via complex simulations and data analysis. To this end, advanced High-Performance-Computing (HPC) software will be leveraged and integrated in easy-to-use industrial trade tools, to lower the barrier for new users, increase the ease of access for experienced users, and allow for smarter decisions to be made in the midstream and downstream energy sectors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Three-Dimensional Flow Analysis Methodology for Assessing Stream Stability and Channel Migration

Increases in the frequency and magnitude of weather events that deviate significantly from average are being observed both globally and in the U.S. Adaptation strategies need to account for and mitigate increased risks to transportation infrastructure that result from more extreme weather. The present study is a part of a project that covers a sensitivity study of the potential impacts of increases in stream flows due to rain events and floods on an active section of the Maple River near Iowa Highway 175 and Danbury, Iowa, which is shown. This study focuses on the use of advanced three-dimensional (3D) computational fluid dynamics (CFD) techniques to enhance the assessment of increased risks to stream stability of a section of the Maple River that may erode into Iowa Highway 175. The methodology developed and presented can be applied to a wide variety of streams and rivers that may face increased risk of migration due to changes in weather patterns and severity of weather events. The Maple River is a laterally active channel flowing through agricultural land that has migrated several hundred feet in recent decades and is currently within approximately 100 feet of the Highway 175 Right-of-Way. In addition to the near-term threat to the highway from the closest river meander, there is also a concern that other river meanders could develop into longer-term threats, especially if increasing intensity or frequency of rain events increase the rate of meander development and channel migration by changing the long-term hydrology of the Maple River.

54 ENVIRONMENTAL SCIENCES↗

Cost Effective 6.5% Silicon Steel Laminate for Electric Machines

Iowa State University teamed with United Technologies Research Center and the University of Delaware and demonstrated a high switching frequency non-rare earth permanent magnet motor. A prototype motor with 400 Hz switching frequency, dummy MnBi permanent magnet with 8 MGOe energy density, and 6.5%Si steel as the laminate materials was designed, built, and tested. The performance of the prototype met the expectations showing a higher frequency motor enabled by 6.5%Si steel is a viable approach to meet DOE 2022 cost and performance targets for electric vehicle drive. Adoption of 6.5%Si steel will result in 3% improvement in energy conversion efficiency of the soft magnetic materials. In addition, the ability to use non-rare earth magnet for high power density application effectively mitigate the risk of EV traction motor from the rising rare earth price.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAB stacks are 625 to 47,237 scfm for LB-C2, 1,704 to 103,131 scfm for LB-S1, and 467 to 18,088 scfm for LB-S2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10 degrees, except for the LB-C2 Fan A results, which were an average of 17.6 degrees; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 3.5% COV, which were all within the range of the target %COV values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗