Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power optimizer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Silicon-on-insulator-based high-voltage, high-temperature integrated circuit gate driver for silicon carbide-based power field effect transistors

Silicon carbide (SiC)-based field effect transistors (FETs) are gaining popularity as switching elements in power electronic circuits designed for high-temperature environments like hybrid electric vehicle, aircraft, well logging, geothermal power generation etc. Like any other power switches, SiC-based power devices also need gate driver circuits to interface them with the logic units. The placement of the gate driver circuit next to the power switch is optimal for minimising system complexity. Successful operation of the gate driver circuit in a harsh environment, especially with minimal or no heat sink and without liquid cooling, can increase the power-to-volume ratio as well as the power-to-weight ratio for power conversion modules such as a DC-DC converter, inverter etc. A silicon-on-insulator (SOI)-based high-voltage, high-temperature integrated circuit (IC) gate driver for SiC power FETs has been designed and fabricated using a commercially available 0.8--m, 2-poly and 3-metal bipolar-complementary metal oxide semiconductor (CMOS)-double diffused metal oxide semiconductor (DMOS) process. The prototype circuit-s maximum gate drive supply can be 40-V with peak 2.3-A sourcing/sinking current driving capability. Owing to the wide driving range, this gate driver IC can be used to drive a wide variety of SiC FET switches (both normally OFF metal oxide semiconductor field effect transistor (MOSFET) and normally ON junction field effect transistor (JFET)). The switching frequency is 20-kHz and the duty cycle can be varied from 0 to 100-. The circuit has been successfully tested with SiC power MOSFETs and JFETs without any heat sink and cooling mechanism. During these tests, SiC switches were kept at room temperature and ambient temperature of the driver circuit was increased to 200-C. The circuit underwent numerous temperature cycles with negligible performance degradation.

99 GENERAL AND MISCELLANEOUS↗

A novel triple power cycle featuring a gas turbine cycle with supercritical carbon dioxide and organic Rankine cycles: Thermoeconomic analysis and optimization

In this study, a novel triple power cycle is proposed where waste heat from a gas turbine cycle is utilized to drive a supercritical carbon dioxide (s-CO 2 ) recompression cycle and a recuperative organic Rankine cycle (ORC) in sequence. A detailed thermoeconomic model is developed and implemented in MATLAB to evaluate the performance of the proposed cycle under different operating conditions. Optimization using a particle swarm optimization (PSO) algorithm is performed to minimize the levelized cost of electricity (LCOE) and determine the optimum design conditions of the cycle. The optimization results show that for a 100 MW cycle, the overall thermal efficiency and LCOE are 0.521 and $\$52.819$/MWh, respectively. The turbine inlet temperature of the gas turbine and s-CO 2 cycles are found as the most influential parameters on the thermoeconomic performance of the triple cycle. The proposed triple cycle shows an excellent waste energy recovery potential and superiority over a very thermodynamically efficient cycle from the literature, which included a gas turbine topping cycle and a complex cascade s-CO 2 power cycle used a bottoming cycle. As a result, the proposed triple cycle shows up to 0.9% points higher efficiency while it has fewer heat exchangers and turbomachinery than the cycle from the literature.

30 DIRECT ENERGY CONVERSION↗

Parallel Hybrid Turboprop Performance Modeling and Optimization

NASA’s Electrified Powertrain Flight Demonstration (EPFD) project conducts ground and flight tests of integrated Megawatt (MW) class hybrid-electric powertrain systems on regional turboprop aircraft demonstrators. To meet the increased demand for assessment of potential capabilities and benefits from these novel vehicle configurations, NASA is developing tooling and models to estimate the performance of hybridized regional turboprops. This paper covers the development of a parametrically driven performance model for a De Havilland Canada Dash 8-400 (Q400) regional turboprop integrated with a novel parallel hybrid architecture using the Gascon framework. Gascon is a modern reimplementation of the General Aviation Synthesis Program (GASP) built using the Condor mathematical modeling framework in Python. Within Gascon, a parametric representation of the parallel hybrid architecture was synthesized, which features the electric motor coupled to the power turbine. This capability allows for in-the-loop optimization of the parametric parallel hybrid architecture to characterize the mission capabilities and fuel savings of the design and determine optimal power scheduling strategies for efficient electric power management for a given mission. The study shows that a fuel savings of up to 20% can be achieved, but that increased fuel savings comes at the expense of payload capacity.

Gascon↗

Transmission Interface Limits for High-Spatial Resolution Capacity Expansion Modeling

Large-scale capacity expansion models typically rely on estimates of the power transfer limits between modeled zones. Accurate estimation of these interface transfer limits (ITLs) requires modeling the underlying transmission network. Here we expand on a maximum flow optimization method that uses linearized power flow to estimate transfer limits. We apply this method to a data set of the U.S. transmission network to estimate ITLs between U.S. counties. By calculating ITLs using different subsets of the network, we evaluate how the size of the network used in the estimation affects the results. The results show diminishing returns to ITL accuracy after six hops, suggesting that a network subset can reasonably be used to approximate ITLs. The county-level estimates produced in this study will support more spatially resolved capacity expansion modeling and will help inform policy making at local and national levels.

capacity planning↗

Transmission Interface Limits for High-Spatial Resolution Capacity Expansion Modeling

Large-scale capacity expansion models typically rely on estimates of the power transfer limits between modeled zones. Accurate estimation of these interface transfer limits (ITLs) requires modeling the underlying transmission network. Here we expand on a maximum flow optimization method that uses linearized power flow to estimate transfer limits. We apply this method to a data set of the U.S. transmission network to estimate ITLs between U.S. counties. By calculating ITLs using different subsets of the network, we evaluate how the size of the network used in the estimation affects the results. The results show diminishing returns to ITL accuracy after six hops, suggesting that a network subset can reasonably be used to approximate ITLs. The county-level estimates produced in this study will support more spatially resolved capacity expansion modeling and will help inform policy making at local and national levels.

capacity planning↗

Parallel Hybrid Turboprop Performance Modeling and Optimization

NASA’s Electrified Powertrain Flight Demonstration (EPFD) project conducts ground and flight tests of integrated Megawatt (MW) class hybrid-electric powertrain systems on regional turboprop aircraft demonstrators. To meet the increased demand for assessment of potential capabilities and benefits from these novel vehicle configurations, NASA is developing tooling and models to estimate the performance of hybridized regional turboprops. This paper covers the development of a parametrically driven performance model for a De Havilland Canada Dash 8-400 (Q400) regional turboprop integrated with a novel parallel hybrid architecture using the Gascon framework. Gascon is a modern reimplementation of the General Aviation Synthesis Program (GASP) built using the Condor mathematical modeling framework in Python. Within Gascon, a parametric representation of the parallel hybrid architecture was synthesized, which features the electric motor coupled to the power turbine. This capability allows for in-the-loop optimization of the parametric parallel hybrid architecture to characterize the mission capabilities and fuel savings of the design and determine optimal power scheduling strategies for efficient electric power management for a given mission. The study shows that a fuel savings of up to 20% can be achieved, but that increased fuel savings comes at the expense of payload capacity.

Gascon↗

On variable hydrostatic transmission for road vehicles, powered by supply of fluid at constant pressure

Various hydrostatic power transmission systems for automotive applications with power supply at constant pressure and unrestricted flow and with a Volvo Flygmotor variable displacement motor as the principal unit were investigated. Two most promising concepts were analyzed in detail and their main components optimized for minimum power loss at the EPA Urban Driving Cycle. The best fuel consumption is less than 10 lit. per 100 kM for a 1542 kG vehicle with a hydrostatic motor and a two speed gear box in series (braking power not recovered). Realistic system pressure affects the fuel consumption just slightly, but the package volume/weight drastically. Back pressure increases losses significantly. Special attention was paid to description of the behavior and modeling of the losses of variable displacement hydrostatic machines.

Magi, M.↗

Systems and methods for energy cost optimization in a building system

Methods and systems to minimize energy cost in response to time-varying energy prices are presented for a variety of different pricing scenarios. A cascaded model predictive control system is disclosed comprising an inner controller and an outer controller. The inner controller controls power use using a derivative of a temperature setpoint and the outer controller controls temperature via a power setpoint or power deferral. An optimization procedure is used to minimize a cost function within a time horizon subject to temperature constraints, equality constraints, and demand charge constraints. Equality constraints are formulated using system model information and system state information whereas demand charge constraints are formulated using system state information and pricing information. A masking procedure is used to invalidate demand charge constraints for inactive pricing periods including peak, partial-peak, off-peak, critical-peak, and real-time.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Agent-Supervisor Coordination for Decentralized Event-Triggered Optimization

This letter proposes decentralized resource-aware coordination schemes for solving network optimization problems defined by objective functions that combine locally evaluable costs with network-wide coupling components. These methods are well suited for a group of supervised agents trying to solve an optimization problem under mild coordination requirements. Each agent has information on its local cost and coordinates with the network supervisor for information about the coupling term of the cost. The proposed approach is feedback-based and asynchronous by design, guarantees anytime feasibility, and ensures the asymptotic convergence of the network state to the desired optimizer. Numerical simulations on a power system example illustrate our results.

decentralized algorithms↗

A Combined Day-ahead and Real-time approach for Scheduling Real and Reactive power dispatch of Battery Energy Storage System

A combined day-ahead (look-ahead) and real-time optimization approach is proposed to schedule BESS real and reactive power dispatch. The look ahead scheduling agent maximizes profit and essentially performs the function of energy arbitrage by looking at forecasted prices, network constraints and BESS operating conditions to generate real power dispatch schedule. While this schedule is followed, the real time optimization agent computes an optimum reactive power set-point (for a particular objective function) using optimal power flow framework. The concepts are implemented by co-simulating legacy tools and demonstrated on a large real world distribution system. In addition to the profits from energy arbitrage, optimum reactive power set point computation results in achieving desirable network attributes like flat voltage profiles and minimizing voltage deviations from desired value.

Bhatti, Bilal A.↗

Data centers as dispatchable loads to harness stranded power

Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast, optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.

97 MATHEMATICS AND COMPUTING↗

Selecting an Architecture for a Safety-Critical Distributed Computer System with Power, Weight and Cost Considerations

This report presents an example of the application of multi-criteria decision analysis to the selection of an architecture for a safety-critical distributed computer system. The design problem includes constraints on minimum system availability and integrity, and the decision is based on the optimal balance of power, weight and cost. The analysis process includes the generation of alternative architectures, evaluation of individual decision criteria, and the selection of an alternative based on overall value. In this example presented here, iterative application of the quantitative evaluation process made it possible to deliberately generate an alternative architecture that is superior to all others regardless of the relative importance of cost.

Torres-Pomales, Wilfredo↗

Optimization of Material Recycling During the Decommissioning Process of Nuclear Power Plants - 16123

The German Government decided in 2011 to phase out nuclear power. Therefore, in the near future there will be several nuclear power plants queued up, in parallel, for dismantling. In nuclear decommissioning there is no standardized procedure available, so that a high level of optimization potential can be assumed. We present the results of a preliminary study, in which the optimization potential of metal recycling during the dismantling process should be estimated. The project can be roughly divided into four sections: - Determination of the metal inventory of an exemplarily selected plant; - Analysis of the recycling routes of scrap metal fractions and assessment of the potential for optimization of each process step during the dismantling; - Conduction of activation calculations to uncover the potential of interim storage allowing for radioactive decay; - In collaboration with the Institute of Process Metallurgy and Metal Recycling at the RWTH Aachen, appropriate process steps and process chains of an optimized metal recycling for each of the resulting scrap metal fractions are identified. The paper and the presentation summarize the status and the results of the project implementation and will address for the optimization potentials for decommissioning projects. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of a method for optimal maneuver analysis of complex space missions

A system that allows mission planners to find optimal multiple-burn space trajectories easily is described. Previously developed methods with different gravity assumptions perform the optimization function. The power of these programs is extended by a method of costate estimation. A penalty function method of constraining coast arc times to be positive is included. The capability of the method is demonstrated by finding the optimal control for three different space missions. These include a shuttle abort-once-around mission and two- and three-burn geosynchronous satellite-placement missions.

Mcadoo, S. F., Jr.↗

TTF3 power coupler thermal analysis for LCLS-II CW operation

The TESLA 9-cell SRF cavity design has been adopted for use in the LCLS-II SRF Linac. Its TTF3 coaxial fundamental power coupler (FPC), optimized for pulsed operation in European XFEL and ILC, requires modest changes to make it suitable for LCLS-II continuous-wave (CW) operation. For LCLS-II it must handle up to 7 kW of power, fully reflected, with the maximum temperature around 450 K, the coupler bake temperature. In order to improve TTF3 FPC cooling, an increased copper plating thickness will be used on the inner conductor of the ‘warm’ section of the coupler. Also, the antenna will be shortened to achieve higher cavity Qext values. Fully 3D FPC thermal analysis has been performed using the SLAC-developed parallel finite element code suite ACE3P, which includes electromagnetic codes and an integrated electromagnetic, thermal and mechanical multi-physics code. In this paper, we present TTF3 FPC thermal analysis simulation results obtained using ACE3P as well as a comparison with measurement results.

43 PARTICLE ACCELERATORS↗

An overview of the operation architectures and energy management system for multiple microgrid clusters

The emerging novel energy infrastructures, such as energy communities, smart building-based microgrids, electric vehicles enabled mobile energy storage units raise the requirements for a more interconnective and interoperable energy system. It leads to a transition from simple and isolated microgrids to relatively large-scale and complex interconnected microgrid systems named multi-microgrid clusters. In order to efficiently, optimally, and flexibly control multi-microgrid clusters, cross-disciplinary technologies such as power electronics, control theory, optimization algorithms, information and communication technologies, cyber-physical, and big-data analysis are needed. This paper introduces an overview of the relevant aspects for multi-microgrids, including the outstanding features, architectures, typical applications, existing control mechanisms, as well as the challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗