Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Classroom aerosol dispersion modeling: experimental assessment of a low-cost flow simulation tool

The purpose of this study was to assess the utility of a low-cost flow simulation tool for an indoor air modeling application by comparing its outputs with the results of a physical experiment, as well as those from a more advanced computational fluid dynamics (CFD) software package. In this study, five aerosol dispersion tests were performed in two different classrooms by releasing a CO 2 tracer gas from six student locations. Resultant steady-state concentrations were monitored at 13 locations around the periphery of the room. Subsequently, the experiments were modeled using both a low-cost tool (SolidWorks Flow Simulation) and a more sophisticated tool (STAR-CCM+). Models were evaluated based on their ability to predict the experimentally measured concentrations at the 13 monitoring locations by calculating four performance parameters commonly used in the evaluation of dispersion models: fractional mean bias (FB), normalized mean-square error (NMSE), fraction of predicted value within a factor of two (FAC2), and normalized absolute difference (NAD). The more sophisticated model performed better in 15 of the 20 possible cases (five tests at four parameters each), with parameters meeting acceptance criteria in 19 of 20 cases. However, the lower-cost tool was only slightly worse, with parameters meeting acceptance criteria in 18 of 20 cases, and it performed better than the other tool in 3 of 20 cases. Because it provides useful results at a fraction of the monetary and training cost and is already widely accessible to many institutions, such a tool may be worthwhile for many indoor aerosol dispersion applications, especially for students or researchers just beginning CFD modeling.

54 ENVIRONMENTAL SCIENCES↗

Pre-Test Feasibility Study Of Reactivity Transient Testing On TRISO Fuel In The TREAT Reactor

Uranium oxycarbide (UCO)-bearing tri-structural isotropic (TRISO) particle fuels are expected to be used in numerous US commercial reactor applications within the next decade. In this work, we reviewed historical particle fuel transient experiments to identify gaps in the TRISO fuel performance transient testing. A BISON--Griffin modeling framework was then developed to conduct preliminary TRISO transient analyses and begin to address these gaps. The framework was demonstrated using limiting-case transient conditions from a prototypic high-temperature gas-cooled reactor. It was then applied to develop a matrix of experiments that could be performed in the Transient Reactor Test Facility (TREAT) to (1) evaluate UCO-fueled particle performance at moderate and high heat rates, (2) assess whether historical testing involving UO$_2$-fueled particles is applicable to modern UCO-fueled particles, (3) deconvolute the impacts of temperature and heat rate on particle transient response, and (4) collect the data needed for fuel performance model validation and/or further development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fluid structural interaction simulation of the MP-1 plate performance irradiated in the advanced test reactor

Due to the high neutron fluxes they generate and increased heat transfer performance, plate type fuels are used in the U.S. high-performance research reactors. During irradiation, a significant amount of fission energy (i.e., ~200 MeV per atom) is released by the U-235 chain reaction that is carried away by the coolant. Through thermal hydraulic analysis, the coolant’s heat transfer capability is investigated to ensure that the desired fuel temperature can be maintained. At high temperatures, the plate undergoes elastic/plastic deformation, creep, and swelling as a result of both the temperature gradients and the fission gas production within the fuel. These effects are studied via fuel performance analysis. When the plate deformation is small enough that the coolant flow remains relatively unchanged, conducting these two types of analyses independently will suffice. But at high fuel burnups, the swollen plates may encroach into the coolant channels that separate the fuel plates from each other and cause these channels to narrow. Large reductions in channel gap size imperil cooling performance, causing fuel temperatures to rise. Further, if the plate deformation is asymmetric, the fuel centerline will shift toward one side of the channel, causing an uneven reduction in coolability. In addition, a boehmite (oxide) layer will, over time, grow on the plate surface, further obstructing the heat transfer process. To precisely predict fuel temperatures/deformation, a complete coupled analysis that considers coolant flow, heat transfer, oxide growth, elastic/plastic deformation, creep, and swelling is needed; however, this type of analysis method is not available in the literature. To fill the gap, this research developed a fluid structure interaction (FSI) approach to the fuel plate analysis, then successfully applied it to the Mini-Plate (MP)-1 experiment, which was irradiated in the Advanced Test Reactor (ATR) for both one and two cycles. The complete analysis coupled STAR-CCM+, a computational fluid dynamic (CFD) software for calculating flow, with Abaqus, a finite element analysis code for calculating plate deformation. Improvements in the results were found when comparing the fully coupled analysis to the independently conducted analyses but they were not significant due to the miniature size of the plates and the relatively short irradiation time. In the future, the fully coupled approach presented herein will be applied to full-size fuel plates with longer irradiation cycles once additional experiments become available.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PELICAN Design, Test Planning, and Commissioning Results

To support design efforts for the Versatile Test Reactor (VTR) core assemblies, an experimental facility has been designed and constructed at Argonne National Laboratory to match the hydraulic flow conditions within the VTR’s primary heat transport system (PHTS). This facility, the Pressure drop Experimental Loop for Investigations of Core Assemblies in advanced Nuclear reactors, PELICAN, provides the ability to measure pressure drop across a full-scale fuel assembly containing prototypic axial reflectors, fuel, and plena components. The PELICAN facility was designed and built to offer maximum flexibility, allowing testing from short sub-sections all the way to the full-length core fuel assemblies. The report presents the high-level program objectives, a summary of the facility design, instrumentation, and control systems, and the testing procedure. The outcomes from facility characterization efforts and first test matrix results are then presented and then, finally, the conclusion contains a summary of the future work to be performed. This test facility was designed to match the hydraulic conditions of the flowing sodium in the VTR using water as a surrogate fluid. To do so, the water is elevated to a temperature of 110°C where its viscosity matches that of sodium, and with a 50-HP centrifugal pump, is capable of generating full scale flow rates to achieve prototypic Reynolds and Euler number flow conditions. To prevent boiling, the system is maintained at elevated pressure of at least 2.7-3.0 bar (40-44 psig). A set of 15 tests have been used to perform checkout activities in order to commission the device, survey the capabilities of PELICAN, and generate experimental data at isothermal conditions and over a range of flow rates up to 44 kg/s (700 GPM) to produce datasets used in the verification and validation of VTR design and modeling efforts. Initial testing focused on facility characterization, which assessed the operational capabilities of various control systems. The thermal control system was qualified, including the thermal response of the loop to the heat added by self- and auxiliary heaters, the chiller and heat exchanger systems for removing excess heat, and their coupled ability to maintain steady-state isothermal conditions as desired. Additionally, the pressure control system was verified to ensure necessary operating environments that promote pump health and prevent boiling of loop inventory at high temperatures could be met. With these systems in place, the first set of matrix tests have been carried out using orifice plates with inner diameters of 2.25-inches and 2.5-inches. Orifice plate flow behavior is well covered in scientific literature, and the results find good agreement with the measured pressure drop vs flow rate and those of theoretical predictions. This initial testing not only helps to validate the experiment, but it also produces a high quality data set for a geometry that is easily reproducible for simulations. Finally, the report is concluded with a discussion of the work to come and provides a snapshot of the test articles in the experimental pipeline whose designs are being inspired by the current designs from the VTR.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Handbook for Performing Hydrocarbon Fuel Fires in XTF For Fast-Heat System Level Tests

This document serves to provide information on all aspects of a system level thermal qualification test including a description of the setup and conduct of a full system fuel fire test in the Thermal Test Complex (TTC) Crosswind Test Facility (XTF). This might be referred to as a “handbook” for future tests. This information is intended to assist technologists and test directors in performing these types of tests in the future.

42 ENGINEERING↗

Chromium Tolerant, Highly Active and Stable Electrocatalytic Internal Surface Coating for Cathode of Commercial SOFCs (Final Report)

This project is aimed to develop a chromium (Cr) tolerant, highly active, and stable coating layer on the internal surfaces of the porous composite cathode from commercially available SOFCs. Such coating layer was developed using the additive manufacturing process of Atomic Layer Deposition (ALD) and has been applied on the cathode consisting of either an electronic conductor of LaxSr 1-x MnyO 3-δ (LSM) or mixed ionic and electronic conducting La x Sr 1-x Co y Fe 1-y O 3-δ (LSCF). PI's work has demonstrated that the internal surface of cathode from the commercial cells, can be further tailored using ALD coating to dramatically enhance the cell performance. For instance, ALD layer consisting heterostructured nano composite of nano-Pt and nano-(Mn 0.8 Co 0.2 ) 3 O 4 oxide on the internal surface of porous LSM/YSZ cathode from SOFCs, has resulted in the large reduction of the cell polarizations resistance by up to 53%, and enormous increase of power density over 370%. For the cells with LSCF/Sm 2 O 3 doped CeO 2 (SDC) cathode, the conformal layer of nano-composite consisting of superjacent CoOx and subjacent minimum amount of Pt nano-grains has resulted in the power density enhancement by 126% for the large scale industry tubular cells at 750°C, and both the performance enhancement and nanostructure of the ALD layer are stable over ~ 2000 h continuous operation performed at industry test station. In the meanwhile, those ALD coating layer developed by PI's work is also inherently Cr-tolerant, and could act as physical barrier for preventing Cr diffusion into the cathode backbone, so as to mitigate the Cr poisoning effect on the cathode. In this project, the impact of Cr on the performance of those ALD coated commercial cells has been evaluated. Based on evolution of the cell performance, the ALD coating layer chemistry and ALD coating layer thickness has been optimized to maximize the overall Cr tolerance, cell power density and cell longevity. Different ALD coating has been applied onto the internal surface of LSM/YSZ and LSCF/SDC backbone respectively. The architecture/scaffold structures on the internal surface of different cathode, designed by this project, was catalogued and analyzed using High Resolution Transmission Electron Microscopy (HRTEM), and cell power/durability performance are assured via comprehensive electrochemical performance testing in the industry operation relevant conditions. The impact of the electrochemical operation current density, the water humidity, the cell operation temperature, and cell operation duration on the Cr tolerance of ALD coated cells has been systematically investigated. There is completely different nanostructure degradation mechanisms between LSM and LSCF cells induced by Cr contamination. For the LSCF/SDC baseline cell, With the Cr source, there is no apparent Sr surface segregation phase even for the baseline cell operated for 3000 h at 750 °C. With the Cr source, there is significant amorphous (SrCr)Ox phase accumulated in the original pore region. For the commercial baseline cells, Cr contaminants on the LSM electrode severely impacted the entire cell's electrochemical performance and nanostructure degradation. Those degradations include (1). Peak power density loss of 64 % after 109 h of operation. The dramatic increase in Rp (2). They are cracking at LSM/SSZ interface, LSM grains. SSZ remains intact but with (CrMn)Ox. By contrast, ALD coating (MnCo)Ox/Pt dramatically improves the Cr resistance, as follows (1). ALD-coated cell with a power density is 280-380 % of the baseline cell, depending on the ALD layer thickness. (2). For a cell with a 20 nm thick ALD layer, there is a large performance enhancement (> 200 % power density) induced by ALD coating of Cr-tolerant Mn 0.8 Co 0.2 Ox. (3). For a cell with a 20 nm thick ALD layer, after 168 h at 750 °C power density of the ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination for 109 h. The ALD coating on the internal surface of cathode developed by this project integrated multi-functions. Those multi-functions include (1). Dramatically improving the cell power density for the commercial cells; (2). Dramatically improving contamination resistance of the cathode, for being an excellent protection coating layer sealing off Cr contamination. (3). Dramatically increasing the cell longevity by potentially preventing the microstructure evolution and grain coarsening of the cathode. Overall, this project will provide a simple solution to simultaneously enhance power density and increase the reliability, robustness, and endurance of commercial SOFCs, over the entire operating temperature range of 650-800 °C. For the inherently functional SOFC, the ALD coating of LSM based cathode mitigate the Cr-contamination. Power density of ALD-coated cell is ~ 600% of that baseline cell upon operation with Cr contamination. In addition to SOFCs, the novel on-demand design approach and creation of multifunctional heterogeneous architecture on the electrode surface presented in this work opens further research for their application in other types of fuel cells, batteries, and sensors for which electrochemical reactions on the surface are similarly critical.

36 MATERIALS SCIENCE↗

Development of ion specific media to treat Sr-contaminated water at Fukushima Daiichi Nuclear Power Plant - 15486

Since April of 2011, Kurion, Inc. contracted with the Tokyo Electric Power Company (TEPCO) to remediate cooling water using Ion Specific Media targeting cesium (Cs). The effluent of the Cs-sorption systems routed into a reverse osmosis (RO) system. While the RO permeate was recirculated into the cooling loop, the RO reject was captured in carbon-steel tanks. However, the cesium-extracted tank water at Fukushima Daiichi also has a high strontium (Sr) activity (∼4 x 10{sup 5} Bq/mL) and needs to be reduced to lower the onsite and boundary doses. To treat this highly contaminated water, Kurion developed the Kurion Mobile Processing System (KMPS). The KMPS uses a powder batch-contact addition step in concert with a series of ion exchange vessels to decontaminate the high Sr-activity water. Kurion tested and developed several ion specific media to treat the water. Several inorganic media were evaluated in the down-select for the system. Equilibrium batch tests, shortened contact time batch tests and column tests were performed to assess the media depending on water conditions. Two media were selected for KMPS: FAS-P (a powdered zeolite) to reduce Ca{sup 2+} and Sr{sup 2+} concentrations and TS-G (a synthetic titanosilicate) to polish the Sr{sup 2+} downstream. The results of these laboratory tests and their performance in the field will be discussed. The operation of the system has led to the continued reduction of dose at the Fukushima Daiichi nuclear power plant. This system and these media can be applied to other difficult wastewater solutions involving high levels of contaminants and salinity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Decarbonization through Autonomous Physics-Centric Deep Learning and Optimization of Building Operations (Abstract only)

This project directly addresses the primary goal of Area of Interest 2 in the CRADA call: to advance optimization-based integrated energy management systems in commercial and residential buildings. Pacific Northwest National Laboratory (PNNL) and its industry partner PassiveLogic aim to accomplish this by reaching three key objectives. First, to ensure a broad impact in the building controls industry, PNNL will extend its open-source library for predictive control synthesis by augmenting its capabilities with data-driven self-learning of building models and auto-calibration of predictive controllers. The effort will focus on building use cases selected in collaboration with PassiveLogic. The team will specifically address the development of methods for data-driven adaptation of building models, investigation of model architectures that best address specific building types, and automated synthesis of differentiable predictive controllers that optimize diverse objectives. Second, PNNL will collaborate with PassiveLogic to integrate the aforementioned methods with PasiveLogic’s advanced controls platform. The collaborative integration effort will inform the developments under the first objective by providing specific data on the attainable performance of model learning on resource-constrained edge computing platforms. This software integration effort will increase the technical maturity of the developed libraries by exploring the use of software integration tools and methods. Third, PNNL and PassiveLogic will work to improve the technology readiness of the developed predictive controllers by testing their performance in relevant test environments, such as high-fidelity simulation, hardware in the loop, and actual test buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Progress towards developing neutron tolerant magnetostrictive and piezoelectric transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Towards eliminating systematic errors caused by the experimental conditions in Biochemical Methane Potential (BMP) tests

Highlights: • The evaluated factors introduce significant systematic errors (10–38%) in BMP tests. • Ambient temperature (T) has the most substantial impact (∼10%) at low altitude. • Ambient pressure (p) has the most substantial impact (∼68%) at high altitude. • Continuous monitoring of T and p is not necessary for kinetic calculations. - Abstract: The Biochemical Methane Potential (BMP) test is increasingly recognised as a tool for selecting and pricing biomass material for production of biogas. However, the results for the same substrate often differ between laboratories and much work to standardise such tests is still needed. In the current study, the effects from four environmental factors (i.e. ambient temperature and pressure, water vapour content and initial gas composition of the reactor headspace) on the degradation kinetics and the determined methane potential were evaluated with a 2{sup 4} full factorial design. Four substrates, with different biodegradation profiles, were investigated and the ambient temperature was found to be the most significant contributor to errors in the methane potential. Concerning the kinetics of the process, the environmental factors’ impact on the calculated rate constants was negligible. The impact of the environmental factors on the kinetic parameters and methane potential from performing a BMP test at different geographical locations around the world was simulated by adjusting the data according to the ambient temperature and pressure of some chosen model sites. The largest effect on the methane potential was registered from tests performed at high altitudes due to a low ambient pressure. The results from this study illustrate the importance of considering the environmental factors’ influence on volumetric gas measurement in BMP tests. This is essential to achieve trustworthy and standardised results that can be used by researchers and end users from all over the world.

09 BIOMASS FUELS↗

Exactly energy conserving semi-implicit particle in cell formulation

We report a new particle in cell (PIC) method based on the semi-implicit approach. The novelty of the new method is that unlike any of its semi-implicit predecessors at the same time it retains the explicit computational cycle and conserves energy exactly. Recent research has presented fully implicit methods where energy conservation is obtained as part of a non-linear iteration procedure. The new method (referred to as Energy Conserving Semi-Implicit Method, ECSIM), instead, does not require any non-linear iteration and its computational cycle is similar to that of explicit PIC. The properties of the new method are: i) it conserves energy exactly to round-off for any time step or grid spacing; ii) it is unconditionally stable in time, freeing the user from the need to resolve the electron plasma frequency and allowing the user to select any desired time step; iii) it eliminates the constraint of the finite grid instability, allowing the user to select any desired resolution without being forced to resolve the Debye length; iv) the particle mover has a computational complexity identical to that of the explicit PIC, only the field solver has an increased computational cost. The new ECSIM is tested in a number of benchmarks where accuracy and computational performance are tested. - Highlights: • We present a new fully energy conserving semi-implicit particle in cell (PIC) method based on the implicit moment method (IMM). The new method is called Energy Conserving Implicit Moment Method (ECIMM). • The novelty of the new method is that unlike any of its predecessors at the same time it retains the explicit computational cycle and conserves energy exactly. • The new method is unconditionally stable in time, freeing the user from the need to resolve the electron plasma frequency. • The new method eliminates the constraint of the finite grid instability, allowing the user to select any desired resolution without being forced to resolve the Debye length. • These features are achieved at a reduced cost compared with either previous IMM or fully implicit implementation of PIC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analytical Model of High-Velocity Impact of a Deformable Projectile Against Textile-Based Composites

Textile-based composites are used in manufacturing of ballistic shields due to their favorable combination of mechanical properties which enables weight saving and efficiency while retaining or even improving ballistic performance. Predictive models are an important tool in reducing experimental tests which are still an important step in ballistic shield design. Among those, analytical models provide less accurate results but require far less computational cost than numerical models and can be used for preliminary analyses. Many authors in the literature have developed analytical models for high-velocity impact on textile-based composites based on wave propagation theory and an energy equilibrium approach. The main limitation of these models is the assumption of rigid projectile which leads to the underestimation of the ballistic limit for soft core projectiles, which are a very common type of threat for this kind of protection. For this reason, an enhanced version of these models is reported in this paper, which releases the assumption of rigid projectile and adds erosion and deformation of the projectile to the formulation. Ballistic tests were performed on panels manufactured from layers of Kevlar 29 plain weave fabric embedded in an epoxy matrix. An insight into the different kinds of energy absorption considered by the model shows that projectile deformation plays an important role in the dissipation of the kinetic energy of the projectile in case of intermediate impact velocity. For this reason, the present model delivers more accurate results than the models present in the literature. In particular, the estimation of the ballistic limit is drastically improved which is a key step in ballistic shields optimization.

36 MATERIALS SCIENCE↗

Systematics in the XENON1T data: The 15-keV anti-axion

The XENON1T collaboration Aprile et al. [2020] has found an excess of electron recoil events in their Science Run 1 data below ~7 keV with a spectral shape consistent with that expected from a solar-axion-induced signal. The claimed statistical significance of the solar-axion model over the null hypothesis is 3.5σ. In this work we provide suggestive evidence for mismodeling in the electron recoil data that may decrease the local significance of the axion model. To reach this conclusion, we search for a signal with the spectral template of the solar axion model, but shifted to higher (unphysical) energies above ~7 keV. We find that the distribution of significances found from this side-band analysis does not follow the expected chi-square distribution. For example, we find a high-significance feature in the data, with a global $p$-value $p≈0.026$, when the solar axion model is shifted upwards in energy by ~15 keV and allowed to have a negative normalization. We argue that such statistical tests, if performed a priori, provide a data-driven way to test and potentially account for systematic uncertainties on the background model in low-threshold dark matter experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

The design and construction of a high-resolution velocity-map imaging apparatus for photoelectron spectroscopy studies of size-selected clusters

A new velocity-map imaging apparatus equipped with a laser-vaporization supersonic cluster source and a time-of-flight mass spectrometer is described for high-resolution photoelectron spectroscopy studies of size-selected cluster anions. Vibrationally cold anion clusters are produced using a laser-vaporization supersonic cluster source, size-selected by a time-of-flight mass spectrometer, and then focused co-linearly into the interaction zone of the high-resolution velocity-map imaging (VMI) system. The multilens VMI system is optimized via systematic simulations and can reach a resolution of 1.2 cm{sup −1} (FWHM) for near threshold electrons while maintaining photoelectron kinetic energy resolutions (ΔKE/KE) of ∼0.53% for higher energy electrons. The new VMI lens has superior focusing power over a large energy range, yielding highly circular images with distortions no larger than 1.0025 between the long and short radii. The detailed design, simulation, construction, testing, and performance of the high-resolution VMI apparatus are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of ultra-short laser induced damage threshold of KH{sub 2}PO{sub 4} crystal: Numerical calculation and experimental verification

Rapid growth and ultra-precision machining of large-size KDP (KH{sub 2}PO{sub 4}) crystals with high laser damage resistance are tough challenges in the development of large laser systems. It is of high interest and practical significance to have theoretical models for scientists and manufacturers to determine the laser-induced damage threshold (LIDT) of actually prepared KDP optics. Here, we numerically and experimentally investigate the laser-induced damage on KDP crystals in ultra-short pulse laser regime. On basis of the rate equation for free electron generation, a model dedicated to predicting the LIDT is developed by considering the synergistic effect of photoionization, impact ionization and decay of electrons. Laser damage tests are performed to measure the single-pulse LIDT with several testing protocols. The testing results combined with previously reported experimental data agree well with those calculated by the model. By taking the light intensification into consideration, the model is successfully applied to quantitatively evaluate the effect of surface flaws inevitably introduced in the preparation processes on the laser damage resistance of KDP crystals. This work can not only contribute to further understanding of the laser damage mechanisms of optical materials, but also provide available models for evaluating the laser damage resistance of exquisitely prepared optical components used in high power laser systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thin epitaxial silicon PIN detectors for thermal neutron detection with improved gamma (γ) discrimination

In order to improve the gamma discrimination capability for thermal neutron measurements using silicon PIN detectors, a novel approach of use of thin epitaxial silicon PIN detectors was investigated. Thin epitaxial silicon detectors with thickness of 15 µm were developed and their performance was tested with thermal neutrons using {sup 10}B converter. The performance of this detector was compared with the performance of a 300 µm silicon detector. The results of experiments presented in this paper indicate that thin epitaxial silicon detectors can significantly improve γ discrimination for thermal neutron measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗