Oscillating-Flow Regenerator Test Rig: Hardware and Theory With Derived Correlations for Screens and Felts

A number of wire mesh and metal felt test samples, with a range of porosities, yield generic correlations for friction factor, Nusselt number, enhanced axial conduction ratio, and overall heat flux ratio. This information is directed primarily toward stirling cycle regenerator modelers, but will be of use to anyone seeking to better model fluid flow through these porous materials. Behind these results lies an oscillating-flow test rig, which measures pumping dissipation and thermal energy transport in sample matrices, and several stages of data-reduction software, which correlate instantaneous values for the above dimensionless groups. Within the software, theoretical model reduces instantaneous quantifies from cycle-averaged measurables using standard parameter estimation techniques.

Gedeon, D.↗

Thermal Infrared Spectral Band Detection Limits for Unidentified Surface Materials

Infrared emission spectra recorded by airborne or satellite spectrometers can be searched for spectral features to determine the composition of rocks on planetary surfaces. Surface materials are identified by detections of characteristic spectral bands. We show how to define whether to accept an observed spectral feature as a detection when the target material is unknown. We also use remotely sensed spectra measured by the Thermal Emission Spectrometer (TES) and the Spatially Enhanced Broadband Array Spectrograph System to illustrate the importance of instrument parameters and surface properties on band detection limits and how the variation in signal-to-noise ratio with wavelength affects the bands that are most detectable for a given instrument. The spectrometer's sampling interval, spectral resolution, signal-to-noise ratio as a function of wavelength, and the sample's surface properties influence whether the instrument can detect a spectral feature exhibited by a material. As an example, in the 6-13 micrometer wavelength region, massive carbonates exhibit two bands: a very strong, broad feature at approximately 6.5 micrometers and a less intense, sharper band at approximately 11.25 micrometers. Although the 6.5-micrometer band is stronger and broader in laboratory-measured spectra, the 11.25-micrometer band will cause a more detectable feature in TES spectra.

Kirkland, Laurel E.↗

Retrieval of Precipitation Profiles from Multiresolution, Multifrequency, Active and Passive Microwave Observations

In this study, a technique for estimating vertical profiles of precipitation from multifrequency, multiresolution active and passive microwave observations is investigated using both simulated and airborne data. The technique is applicable to the Tropical Rainfall Measuring Mission (TRMM) satellite multi-frequency active and passive observations. These observations are characterized by various spatial and sampling resolutions. This makes the retrieval problem mathematically more difficult and ill-determined because the quality of information decreases with decreasing resolution. A model that, given reflectivity profiles and a small set of parameters (including the cloud water content, the intercept drop size distribution, and a variable describing the frozen hydrometeor properties), simulates high-resolution brightness temperatures is used. The high-resolution simulated brightness temperatures are convolved at the real sensor resolution. An optimal estimation procedure is used to minimize the differences between simulated and observed brightness temperatures. The retrieval technique is investigated using cloud model synthetic and airborne data from the Fourth Convection And Moisture Experiment. Simulated high-resolution brightness temperatures and reflectivities and airborne observation strong are convolved at the resolution of the TRMM instruments and retrievals are performed and analyzed relative to the reference data used in observations synthesis. An illustration of the possible use of the technique in satellite rainfall estimation is presented through an application to TRMM data. The study suggests improvements in combined active and passive retrievals even when the instruments resolutions are significantly different. Future work needs to better quantify the retrievals performance, especially in connection with satellite applications, and the uncertainty of the models used in retrieval.

Grecu, Mircea↗

The Complete Spectral Catalog of Bright BATSE Gamma-Ray Bursts

We present a systematic spectral analysis of 350 bright Gamma-Ray Bursts (GRBs) observed by the Burst and Transient Source Experiment (BATSE; approx. 30 keV - 2 MeV; including 17 short GRBs) with high energy and time resolution. Our sample was selected from the complete set of 2704 BATSE GRBs based on their energy fluence or peak photon flux values to assure good statistics. To obtain well-constrained, model-unbiased spectral parameters, a set of various photon models is used to fit each spectrum, and internal characteristics of each model are also investigated. A thorough analysis has been performed on 342 time-integrated and 8459 time-resolved burst spectra, and the effects of integration times in determining the spectral parameters are explored. The analysis results presented here provide the most detailed perspective of spectral aspects of the GRB prompt emission to date. Using the results, we study correlations among spectral parameters and spectral evolutions. The results of all spectral fits are available electronically in FITS format, from the High-Energy Astrophysics Science Archive Research Center (HEASARC).

Kaneko, Yuki↗

Bulk Surface Momentum Parameters for Satellite-Derived Vegetation Fields

The bulk aerodynamic parameters associated with the absorption of surface momentum by vegetated landscapes are theoretically estimated within the context of Raupach's roughness sublayer formulation. The parameters include the bulk plant drag coefficient, maximum u*/U(sub h), sheltering coefficient, and canopy area density at onset of sheltering. Parameters are estimated for the four principal IGBP land cover classes within the U.S. Southern Great Plains: evergreen needleleaf forests, grasslands, croplands, and open shrublands. The estimation approach applies the Method of Moments to roughness data from several international field experiments and other published sources. The results provide the necessary land surface parameters for satellite-based estimation of momentum aerodynamic roughness length and zero-plane displacement height for seasonally variable vegetation fields employed in most terrestrial and atmospheric simulation models used today. Construction of sample displacement and roughness maps over the Southern United States using MODIS land products demonstrates the potential of this approach for regional to global applications.

Jasinski, Michael F.↗

Development of Three-Dimensional Multicellular Tissue-Like Constructs for Mutational Analysis Using Macroporous Microcarriers

A three-dimensional (3-D), tissue-like model was developed for the genotoxic assessment of space environment. In previous experiments, we found that culturing mammalian cells in a NASA-designed bioreactor, using Cytodex-3 beads as a scaffold, generated 3-D multicellular spheroids. In an effort to generate scaffold-free spheroids, we developed a new 3-D tissue-like model by coculturing fibroblast and epithelial cell in a NASA bioreactor using macroporous Cultispher-S(TradeMark) microcarriers. Big Blue(Registered Trademark) Rat 2(Lambda) fibroblasts, genetically engineered to contain multiple copies (>60 copies/cell) of the Lac I target gene, were cocultured with radio-sensitive human epithelial cells, H184F5. Over an 8-day period, samples were periodically examined by microscopy and histology to confirm cell attachment, growth, and viability. Immunohistochemistry and western analysis were used to evaluate the expression of specific cytoskeletal and adhesion proteins. Key cell culture parameters (glucose, pH, and lactate concentrations) were monitored daily. Controls were two-dimensional mono layers of fibroblast or epithelial cells cultured in T-flasks. Analysis of 3-D spheroids from the bioreactor suggests fibroblast cells attached to and completely covered the bead surface and inner channels by day 3 in the bioreactor. Treatment of the 3-day spheroids with dispase II dissolved the Cultisphers(TradeMark) and produced multicellular, bead-less constructs. Immunohistochemistry confirmed the presence of vi.mentin, cytokeratin and E-cadherin in treated spheroids. Examination of the dispase II treated spheroids with transmission electron microscopy (TEM) also showed the presence of desmosomes. These results suggest that the controlled enzymatic degradation of an artificial matrix in the low shear environment of the NASA-designed bioreactor can produce 3-D tissue-like spheroids. 2

Jordan, Jacqueline A.↗

Design and Development of the SMAP Microwave Radiometer Electronics

The SMAP microwave radiometer will measure land surface brightness temperature at L-band (1413 MHz) in the presence of radio frequency interference (RFI) for soil moisture remote sensing. The radiometer design was driven by the requirements to incorporate internal calibration, to operate synchronously with the SMAP radar, and to mitigate the deleterious effects of RFI. The system design includes a highly linear super-heterodyne microwave receiver with internal reference loads and noise sources for calibration and an innovative digital signal processor and detection system. The front-end comprises a coaxial cable-based feed network, with a pair of diplexers and a coupled noise source, and radiometer front-end (RFE) box. Internal calibration is provided by reference switches and a common noise source inside the RFE. The RF back-end (RBE) downconverts the 1413 MHz channel to an intermediate frequency (IF) of 120 MHz. The IF signals are then sampled and quantized by high-speed analog-to-digital converters in the radiometer digital electronics (RDE) box. The RBE local oscillator and RDE sampling clocks are phase-locked to a common reference to ensure coherency between the signals. The RDE performs additional filtering, sub-band channelization, cross-correlation for measuring third and fourth Stokes parameters, and detection and integration of the first four raw moments of the signals. These data are packetized and sent to the ground for calibration and further processing. Here we discuss the novel features of the radiometer hardware particularly those influenced by the need to mitigate RFI.

radio frequency interference↗

Reply to Comment by Laprise on 'the Added Value to Global Model Projections of Climate Change by Dynamical Downscaling: a Case Study over the Continental U.S. Using the GISS-ModelE2 and WRF Models'

In his comment, Laprise raises several points that we agree merit consideration. His primary critique is that our study [Racherla et al., 2012] tested the ability of the WRF regional climate model to reproduce historical temperature and precipitation change relative to the driving global climate model (GCM) using only a single simulation rather than an ensemble. He asserts that the observed changes are smaller than the internal variability in the climate system (i.e., not statistically significant) and that thus a single simulation should not necessarily be able to capture the observations. Laprise points out that the statistical signal is reduced for a multi-decadal trend such as the one we analyzed in comparison with mean climatology and cites two studies showing that for particular climate parameters it can take any years for a signal to be discerned over internal variability. He states that The results of theexperiment as designed were strongly influenced by the presence of internal variability and sampling errors,which masked the rather small climate changes that may have occurred as a consequence of changes inforcing during the period considered. While Laprise discusses statistics in general terms at some length, for the actual climate trends examined in our study, he offers no evidence that the forced signal was smallcompared with internal variability. The two studies he cites [de Ela et al., 2013; Maraun, 2013] do not provide convincing evidence as they concern climate variables averaged over different times and areas. One in fact examines extreme precipitation events, which by definition are rare and thus have a lower significance level. We accept the general point that it is important to consider internal variability, and as noted in our paper we agree that an ensemble of simulations is in principle an optimal, though computationally expensive, approach. While we did not present the statistical significance of the observations in our original paper, we have now evaluated those for the regional temperature trends used in our study to evaluate the added value of WRF and thus can analyze data as to the magnitude of the trends with respect to internal variability.

climate↗

Investigation of Magmatic Activities on Early Mars Using Igneous Mineral Chemistry in Gale Crater, Mars

One objective of rover missions is exploring the geological context of the surroundings. Over the years, igneous petrology and sedimentology have been disconnected, the first investigating magmatic processes and volcanic activities, and the second seeking environmental conditions in the past and assessing the habitability of the planet. Although different, one is related to the other: igneous rocks are altered and broken down, leading to the formation of sedimentary rocks, which can in turn be used to back out the nature of their magmatic source. The Curiosity rover that landed in the 3.7 Gyr old impact crater Gale is traveling through sedimentary rocks. About fifty float rocks have been observed, and several of them with ambiguous texture and composition have been classified as igneous or sedimentary depending on studies such as Jake_M. The composition of several unambiguous igneous rocks has been analyzed [4- 6] but their heterogeneity at a larger instrumental (measurement size < 2 cm) scale prevents the measurement of a bulk composition as performed on Earth. An original approach avoiding these two last issues is to consider igneous mineral chemistry analyzed within igneous and sedimentary rocks to assess magmatic processes that could have formed them. Most Curiosity data are used to explore ancient environmental conditions, and a significant number of compositional analyses are under-explored for constraining magmatic activities. We will present how we can make use of sedimentary data for investigating igneous processes in the vicinity of Gale crater. Geological Context: We focus on the first 750 martian days, corresponding to measurements in a coherent lacustrine sedimentary unit called Bradbury, because all sedimentary rocks were sourced from the same watershed and appear to have a consistent source with minimal alteration [2-3]. Igneous detrital minerals including feldspar and pyroxene, are observed in sedimentary rocks. Monte Carlo models showed that minimal cation loss is observed based on the composition of all Bradbury rocks, implying negligible weathering [3]. Although clay minerals are detected in few rocks [7], chemical compositions of rocks can be explained by a mixture of primary igneous minerals [3]. Variation of composition within Bradbury rocks can be explained by mineral sorting and one distinct source component. While a common magmatic source is suggested, Bradbury sediments likely come from several volcanic eruptions from a single magmatic chamber [9- 10]. The occurrence of alkali minerals like sanidine and K-rich rocks throughout Bradbury supports the presence of a potassic component, likely trachytic, while plagioclase and a mafic composition suggest a basaltic component [8-9]. Instruments: Mineral chemistry can be estimated by three instruments onboard Curiosity. The CheMin instrument enables detection of mineral assemblages using X-ray diffraction (XRD). Using Rietveld refinement, each mineral is identified according to their 1D XRD pattern [11]. Note that distinction between pyroxene minerals is challenging with the CheMin instrument due to overlapping peaks on XRD patterns and low angular resolution of the instrument [12]. Then, using least square regression and optimization algorithms based on unit-cell parameters, mineral chemistry has been estimated by [11]. Plagioclase composition has been estimated using the NaAlSi3O8- CaAl2Si2O8 system and alkali feldspar is based on the NaAlSi3O8-KAlSi3O8 system (stars in Fig.1). Two mudstone samples (John Klein and Cumberland) and one sandstone sample (Windjana) were analyzed by CheMin at Yellowknife Bay and Kimberley, respectively. Figure 1. Ternary diagrams of feldspars (top) and pyroxene (bottom) quadrilateral. Stars correspond to CheMin composition and the gray patches to ChemCam composition. The colored dots are the composition of feldspar and pyroxene that crystallized during fractional crystallization at FMQ+1 of a melt extracted at distinct melting degree during the adiabatic ascent of a primitive mantle composition, without any water (left panels) and with 0.5 wt.% of water (right panels) at distinct pressure. The ChemCam instrument enables the analysis of the chemical compositions of rocks at hundreds of micrometer scale (350-550 μm) using laser induced breakdown spectroscopy (LIBS), which may provide the composition of minerals when they are larger than the beam spot (>550 μm) [13]. Within >5000 LIBS points, we performed a typical stoichiometric filtering allowing us to distinguish 56 feldspar and 10 pyroxene mineral compositions (grey patches in Fig. 1). Finally, the Alpha Particle X-ray Spectrometer (APXS) analyzes the composition of rocks with a 1.6 cm diameter spot size. Monte Carlo mass balance modeling allowed [3] to decipher a feldspar range varying between An30 and An40 (Fig. 1). Discussion: Although there could be a more complex history and other ways to form the whole compositional range of igneous minerals analyzed within the Bradbury formation, we are presenting here simple magmatic pathways commonly occurring on Earth using the thermodynamical softwares pMELTS and rhyoliteMELTS [14]. The objective is to find reasonable igneous processes that produce minerals that parallel the compositions of feldspar and pyroxene analyzed by the Curiosity rover. As commonly observed for mid-ocean ridge basalts, the adiabatic ascent of a primitive mantle composition [15] partially melting at 2 GPa has been modeled, followed by the extraction of a liquid at distinct degrees of partial melting, which undergoes fractional crystallization at an oxygen fugacity +1 log unit above the fayalite-magnetite-quartz (FMQ) buffer within the crust (0.02-0.4 GPa) with H2O = 0- 0.5 wt. %. These latter conditions correspond to those recorded within igneous clasts from the Noachian martian breccia NWA 7034 and paired and within Gale igneous rocks (colored dots in Fig. 1) [16-17]. To check the reliability of these 2-step models, we also tested fractional crystallization at similar conditions (FMQ+1; P=0.02-0.4 GPa; H2O = 0-0.5 wt. %) of starting compositions corresponding to that of magmas with distinct melting degrees obtained from isobaric experiments at 2 GPa [18]. Mineral compositions obtained from both models are similar. As shown on Fig. 1, the whole range of observed feldspar compositions cannot be reproduced by fractionation of one magma only. Indeed, while alkali feldspar and Na-plagioclase likely crystallized from fractional crystallization of a low-degree melt (here <15%), plagioclase and pyroxene can only be formed by fractional crystallization of a higher degree melt (here >19%). The corresponding liquid descent lines are broadly in agreement with compositions estimated by ChemCam corresponding to float igneous rocks (Fig. 2) [4-6]. Figure 2. Silica versus alkali content. Lines show the liquid lines of descent from magmas with distinct degrees of melting. Gray patches represents the composition of Gale igneous rocks [4-6]. Trachytic to rhyolitic magmas crystallize alkali feldspar, and andesite to dacite magmas likely form plagioclase. Therefore, at least two starting magmas at distinct melting degrees, which could easily come from a single mantle source, are necessary to explain the whole compositional range of feldspar and pyroxene analyzed within Bradbury rocks. Conclusion: Because rocks from the Bradbury formation are likely originating from the same magmatic source with minimal weathering as supported by several studies using different approaches, igneous mineral chemistry analyzed by CheMin and ChemCam allows us to back out reasonable magmatic pathways that could have crystallized them. Fractional crystallization of at least two starting magmas originating from distinct melting degrees of a single mantle source can explain the whole range of feldspar and pyroxene composition. Both alkaline and sub-alkaline liquids can be produced, with compositions corresponding to those of the igneous rocks analyzed by ChemCam within the Bradbury formation, highlighting the complexity of Mars magmatism.

Payre, V.↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O2was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M Weisberger↗

Characterization Progress of an Absorption Laser Differential Interferometer

An absorption laser differential interferometer (A-LDI) system can be used to provide simultaneous, colinear measurements of flow properties (pressure, temperature, concentration, velocity) and flow fluctuations. Further characterization work on the absorption aspect of the system is provided in this paper, including characterization of the laser operating parameters, comparisons of two etalons of different free spectral range, and the further evaluation of a fixed-wavelength absorption measurement that can be used to obtain absorption and LDI measurements with the same sampling rate. A 0.4 GHz etalon was demonstrated to provide sufficient fringe peaks at low modulation depths to be used for the low-pressure testing characteristic of hypersonic wind tunnel facilities. The use of a 3 GHz etalon as a low-cost relative wavemeter was tested and validated. Data taken with the fixed-wavelength strategy in a sub-atmospheric test cell using 100% O 2 was successful and will allow absorption and LDI data to be acquired simultaneously, colinearly, and at the same sampling rate, yielding a truly simultaneous measurement of the flow density fluctuations and the flow mean density.

Joshua M. Weisberger↗

Response characteristics of laser diffraction particle size analyzers - Optical sample volume extent and lens effects

The response characteristics of laser diffraction particle sizing instruments were studied theoretically and experimentally. In particular, the extent of optical sample volume and the effects of receiving lens properties were investigated in detail. The experimental work was performed with a particle size analyzer using a calibration reticle containing a two-dimensional array of opaque circular disks on a glass substrate. The calibration slide simulated the forward-scattering characteristics of a Rosin-Rammler droplet size distribution. The reticle was analyzed with collection lenses of 63 mm, 100 mm, and 300 mm focal lengths using scattering inversion software that determined best-fit Rosin-Rammler size distribution parameters. The data differed from the predicted response for the reticle by about 10 percent. A set of calibration factor for the detector elements was determined that corrected for the nonideal response of the instrument. The response of the instrument was also measured as a function of reticle position, and the results confirmed a theoretical optical sample volume model presented here.

Hirleman, E. D.↗

Simultaneous high-P, high-T X ray diffraction study of beta-(Mg,Fe)2SiO4 to 26 GPa and 900 K

Attention is given to the lattice parameters of beta phase (Mg(0.84)Fe(0.16))2SiO4 determined by X-ray diffraction using synchrotron radiation under simultaneous high-pressure and high-temperature conditions. The experiments were conducted up to a pressure of 26 GPa and a temperature of 900 K. High pressures were generated in a Mao-Bell type diamond anvil cell using neon gas as a pressure medium. The sample was heated with an external Ni80Cr20 wire heater. Gold was used as an internal high-pressure calibrant at high temperature. The experimental data indicated the anisotropic behavior of the beta phase at high pressure and temperature, i.e., the c axis is about 35-percent more expansible and about 25-percent more compressible than the a and b axes. A value of 5.1 +/-0.8 was found for the Anderson-Grueneisen parameter. The derived thermodynamic parameters for the beta phase are summarized.

Fei, Yingwei↗

Containerless processing of undercooled melts

The investigation focused on the control of microstructural evolution in Mn-Al, Fe-Ni, Ni-V, and Au-Pb-Sb alloys through the high undercooling levels provided by containerless processing, and provided fundamental new information on the control of nucleation. Solidification analysis was conducted by means of thermal analysis, x-ray diffraction, and metallographic characterization on samples processed in a laboratory scale drop tube system. The Mn-Al alloy system offers a useful model system with the capability of phase separation on an individual particle basis, thus permitting a more complete understanding of the operative kinetics and the key containerless processing variables. This system provided the opportunity of analyzing the nucleation rate as a function of processing conditions and allowed for the quantitative assessment of the relevant processing parameters. These factors are essential in the development of a containerless processing model which has a predictive capability. Similarly, Ni-V is a model system that was used to study duplex partitionless solidification, which is a structure possible only in high under cooling solidification processes. Nucleation kinetics for the competing bcc and fcc phases were studied to determine how this structure can develop and the conditions under which it may occur. The Fe-Ni alloy system was studied to identify microstructural transitions with controlled variations in sample size and composition during containerless solidification. This work was forwarded to develop a microstructure map which delineates regimes of structural evolution and provides a unified analysis of experimental observations. The Au-Pb-Sb system was investigated to characterize the thermodynamic properties of the undercooled liquid phase and to characterize the glass transition under a variety of processing conditions. By analyzing key containerless processing parameters in a ground based drop tube study, a carefully designed flight experiment may be planned to utilize the extended duration microgravity conditions of orbiting spacecraft.

Perepezko, J. H.↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Monte Carlo inversion of seismic data

The analytic solution to the linear inverse problem provides estimates of the uncertainty of the solution in terms of standard deviations of corrections to a particular solution, resolution of parameter adjustments, and information distribution among the observations. It is shown that Monte Carlo inversion, when properly executed, can provide all the same kinds of information for nonlinear problems. Proper execution requires a relatively uniform sampling of all possible models. The expense of performing Monte Carlo inversion generally requires strategies to improve the probability of finding passing models. Such strategies can lead to a very strong bias in the distribution of models examined unless great care is taken in their application.

Wiggins, R. A.↗

Lake Superior water quality near Duluth from analysis of aerial photos and ERTS imagery

ERTS imagery of Lake Superior in the late summer of 1972 shows dirty water near the city of Duluth. Water samples and simultaneous photographs were taken on three separate days following a heavy storm which caused muddy runoff water. The water samples were analyzed for turbidity, color, and solids. Reflectance and transmittance characteristics of the water samples were determined with a spectrophotometer apparatus. This same apparatus attached to a microdensitometer was used to analyze the photographs for the approximate colors or wavelengths of reflected energy that caused the exposure. Although other parameters do correlate for any one particular day, it is only the water quality parameter of turbidity that correlates with the aerial imagery on all days, as the character of the dirty water changes due to settling and mixing.

Scherz, J. P.↗

Electromagnetic radiation screening of microcircuits for long life applications

The utility of X-rays as a stimulus for screening high reliability semiconductor microcircuits was studied. The theory of the interaction of X-rays with semiconductor materials and devices was considered. Experimental measurements of photovoltages, photocurrents, and effects on specified parameters were made on discrete devices and on microcircuits. The test specimens included discrete devices with certain types of identified flaws and symptoms of flaws, and microcircuits exhibiting deviant electrical behavior. With a necessarily limited sample of test specimens, no useful correlation could be found between the X-ray-induced electrical response and the known or suspected presence of flaws.

Brammer, W. G.↗