Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microwave techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Sparse inpainting and isotropy

Sparse inpainting techniques are gaining in popularity as a tool for cosmological data analysis, in particular for handling data which present masked regions and missing observations. We investigate here the relationship between sparse inpainting techniques using the spherical harmonic basis as a dictionary and the isotropy properties of cosmological maps, as for instance those arising from cosmic microwave background (CMB) experiments. In particular, we investigate the possibility that inpainted maps may exhibit anisotropies in the behaviour of higher-order angular polyspectra. We provide analytic computations and simulations of inpainted maps for a Gaussian isotropic model of CMB data, suggesting that the resulting angular trispectrum may exhibit small but non-negligible deviations from isotropy.

79 ASTRONOMY AND ASTROPHYSICS↗

Interaction of Microwaves with Photoelectrons in Semiconductors

Microwave photoconductive decay is widely used to measure the recombination lifetime in semiconductors and is generally considered to be a low-injection technique. Here, the authors examine the technique in detail from both a theoretical and experimental perspective. When the skin or penetration depth is much less than the sample thickness, the reflectance-conductivity relationship is nonlinear when the injected carrier density exceeds about 5% of background doping. However, when the penetration depth is much larger than the sample thickness, the transmitted signal is linear over several orders of magnitude of sample conductivity. In the transmission mode of operation, high-injection lifetime measurements are accurate.

14 SOLAR ENERGY↗

Ultra-narrow-linewidth hybrid-integrated self-injection locked laser at 780 nm

Narrow-linewidth lasers are essential across a wide range of applications, including classical and quantum sensing, trapped ion systems, position/navigation/timing systems, optical clocks, and microwave frequency synthesizers. In the visible and near-visible spectrum, low-noise lasers are particularly important for laser trapping and cooling techniques, which are vital for trapped ion quantum computing, sensing, and atomic clocks. In this context, our work showcases a hybrid-integrated narrow-linewidth laser that operates at 780 nm, achieving a self-heterodyne linewidth of 105 Hz. To validate the experimental results, we performed a numerical analysis that combines insights from a many-body theory applied to the gain region with a travelling-wave model to capture the laser dynamics. Our investigation further delves into how the linewidth of the self-injection locked lasers is influenced by the parameters of micro-ring resonators, aiming to assess the potential for achieving Hz-level integrated laser linewidths at 780 nm. This work not only demonstrates the technical feasibility of Hz-level narrow-linewidth lasers but also lays the groundwork for future explorations in the field.

Prokoshin, Artem (ORCID:0009000699760238)↗

Laboratory Research

To properly interpret the rapidly growing body of data from comet observations, many types of laboratory measurements are needed. These include: (1) molecular spectroscopy in the visible, ultraviolet, infrared and microwave region of the spectra; (2) laser fluorescent spectroscopy of photofragments; (3) laboratory cross-section or reaction rate measurements using flow tube techniques, fluorescent spectroscopy detection for neutrals and ion-molecule reaction techniques; (4) experiments to simulate solar-wind interactions with comets; (5) studies of the properties and behavior of ice mixtures; (6) experiments on the sublimation rate of ice, and the phase transition from amorphous to crystalline ice; (7) investigations of the irradiation of ice; and (8) the electron impact dissociation and excitation of molecules of cometary interest. A nearly completed experiment on the proton irradiation of ice is described.

Donn, B.↗

Microwave Radiation Detector

Direct photon detector responds to microwave frequencies. Method based on trapped-ion frequency-generation standards proposed to detect radio-frequency (RF) radiation at 40.5 GHz. Technique used for directdetection (RF) communication, radar, and radio astronomy.

Lesh, J. R.↗

Tuning Concept for Resonant Cavities

Deviations from resonance detected by sampling phases. Automatic tuner feedback control system derives error signal from E and H plane probe signals. Control objective to maintain phase difference between E and H at 90 degrees. Technique estimated to sensitive to fractional frequency deviation of about 5 X 10-16 and applicable not only to masers but also other microwave elements, including klystrons, general purpose oscillators, and frequency standards.

Sydnor, R. L.↗

Measuring Clouds With Microwaves and Infrared

Combination of microwave and infrared measurements from satellites yields data from which thicknesses and temperature of clouds inferred. Microwave radiation measured by satellite used to determine thickness of cloud and difference between cloud-top temperature and mean temperature of interior. Technique extends capability of previously established method in which infrared radiation returned to satellite by cloud used to determine temperature and altitude of cloud top and fractional area of Earth covered by cloud.

Pandey, P. C.↗

A multisensor approach to sea ice classification for the validation of DMSP-SSM/I passive microwave derived sea ice products

The validation of sea ice products derived from the Special Sensor Microwave Imager (SSM/I) on board a DMSP platform is examined using data from the Landsat MSS and NOAA-AVHRR sensors. Image processing techniques for retrieving ice concentrations from each type of imagery are developed and results are intercompared to determine the ice parameter retrieval accuracy of the SSM/I NASA-Team algorithm. For case studies in the Beaufort Sea and East Greenland Sea, average retrieval errors of the SSM/I algorithm are between 1.7 percent for spring conditions and 4.3 percent during freeze up in comparison with Landsat derived ice concentrations. For a case study in the East Greenland Sea, SSM/I derived ice concentration in comparison with AVHRR imagery display a mean error of 9.6 percent.

Steffen, K.↗

Observations of the Thermal Structure and Dynamics of the Martian Atmosphere

Information on the thermal structure of the Martian atmosphere has been obtained using several different techniques, including in situ sounding from decent probes, radio occultations and infrared thermal emission measurements from orbiters, and earth based full-disk microwave measurements. Knowledge of the 3- dimensional atmospheric temperature field and its temporal variation provides an important observational approach to the study of the dynamics of the atmosphere. Comparison of the observed thermal structure with results from a Mars General Circulation Model (MGCM) can be used to refine the model and provide greater insight into the physical processes controlling the dynamics of the atmosphere. Direct assimilation of the temperature observations into an MGCM can also be used to address similar goals. In addition, relatively simple diagnostic models can be applied to the data to directly obtain information on winds and other meteorological properties of the atmosphere. In this overview, we concentrate primarily on the structure retrieved from thermal emission measurements. Additional information is contained in the original extended abstract.

Conrath, B. J.↗

Observation of Spontaneous Coherence in Bose-Einstein Condensate of Magnons

The room-temperature dynamics of a magnon gas driven by short microwave pumping pulses is studied. An overpopulation of the lowest energy level of the system following the pumping is observed. Using the sensitivity of the Brillouin light scattering technique to the coherence degree of the scattering magnons we demonstrate the spontaneous emergence of coherence of the magnons at the lowest level, if their density exceeds a critical value. This finding is clear proof of the quantum nature of the observed phenomenon and direct evidence of Bose-Einstein condensation of magnons at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave remote sensing: Active and passive. Volume 2 - Radar remote sensing and surface scattering and emission theory

The fundamental principles of radar backscattering measurements are presented, including measurement statistics, Doppler and pulse discrimination techniques, and associated ambiguity functions. The operation of real and synthetic aperture sidelooking airborne radar systems is described, along with the internal and external calibration techniques employed in scattering measurements. Attention is given to the physical mechanisms responsible for the scattering emission behavior of homogeneous and inhomogeneous media, through a discussion of surface roughness, dielectric properties and inhomogeneity, and penetration depth. Simple semiempirical models are presented. Theoretical models involving greater mathematical sophistication are also given for extended ocean and bare soil surfaces, and the more general case of a vegetation canopy over a rough surface.

Ulaby, F. T.↗

Microwave induced plasma discharge in multi-cell superconducting radio-frequency cavity

A R&D effort for in situ cleaning of 1.5 GHz Superconducting Radio Frequency (SRF) cavities at room temperature using the plasma processing technique has been initiated at Jefferson Lab. This is a step toward the cleaning of cryomodules installed in the Continuous Electron Beam Accelerator Facility (CEBAF). For this purpose, we have developed an understanding of plasma discharge in a 5-cell CEBAF-type SRF cavity having configurations similar to those in the main accelerator. The focus of this study involves the detailed investigations of developing a plasma discharge inside the cavity volume and avoids the breakdown condition in the vicinity of the ceramic RF window. A plasma discharge of the gas mixture Ar–O{sub 2} (90%:10%) can be established inside the cavity volume by the excitation of a resonant 4π/5 TM{sub 010}-mode driven by a klystron. The absence of any external magnetic field for generating the plasma is suitable for cleaning cavities installed in a complex cryomodule assembly. The procedures developed in these experimental investigations can be applied to any complex cavity structure. Details of these experimental measurements and the observations are discussed in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave remote plasma enhanced-atomic layer deposition system with multicusp confinement chamber

A microwave remote Plasma Enhanced-Atomic Layer Deposition system with multicusp confinement chamber is established at the Plasma and Beam Physics research facilities, Chiang Mai, Thailand. The system produces highly-reactive plasma species in order to enhance the deposition process of thin films. The addition of the multicusp magnetic fields further improves the plasma density and uniformity in the reaction chamber. Thus, the system is more favorable to temperature-sensitive substrates when heating becomes unwanted. Furthermore, the remote-plasma feature, which is generated via microwave power source, offers tunability of the plasma properties separately from the process. As a result, the system provides high flexibility in choice of materials and design experiments, particularly for low-temperature applications. Performance evaluations of the system were carried on coating experiments of Al{sub 2}O{sub 3} layers onto a silicon wafer. The plasma characteristics in the chamber will be described. The resulted Al{sub 2}O{sub 3} films—analyzed by Rutherford Backscattering Spectrometry in channeling mode and by X-ray Photoelectron Spectroscopy techniques—will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rotating odd-parity Lorentz invariance test in electrodynamics

We report the first operation of a rotating odd-parity Lorentz invariance test in electrodynamics using a microwave Mach-Zehnder interferometer with permeable material in one arm. The experiment sets a direct bound to {kappa}{sub tr} of -0.3{+-}3x10{sup -7}. Using new power recycled waveguide interferometer techniques (with the highest spectral resolution ever achieved of 2x10{sup -11} rad/{radical}(Hz)) we show an improvement of several orders of magnitude is attainable in the future.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic and Atomic Structure Parameters of Sc-doped Barium Hexagonal Ferrites

Scandium-doped M-type barium hexagonal ferrites of the composition BaFe12?xScxO19 are well suited for low frequency microwave device applications such as isolators and circulators. A series of Sc-doped M-type barium hexagonal ferrite powders (x = 0-1.2) were prepared by conventional ceramic processing techniques. The resulting powders were verified to be pure phase and maintain the nominal chemical stoichiometry by x-ray diffraction and energy dispersive x-ray spectroscopy, respectively. Static magnetic measurements indicated that both saturation magnetization and uniaxial magnetocrystalline anisotropy field decreased with increasing concentration of scandium. Extended x-ray absorption fine structure measurements were carried out to clarify the correlation between the magnetic and atomic structure properties. It is found that the substituted Sc has a strong preference for the bipyramidal site. Nevertheless, the substitution did not introduce additional atomic structural disorder into the barium hexagonal structure. The structural study provided important evidence to quantitatively explain the change in dc and microwave magnetic properties due to Sc ion doping.

36 MATERIALS SCIENCE↗