Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Integrated Bare Narrow Capillary-Hydrodynamic Chromatographic System for Free-Solution DNA Separation at the Single-Molecule Level

We have recently introduced a new technique, Bare Narrow Capillary Hydrodynamic Chromatography (BaNC–HDC), to resolve DNA without sieving matrices. In this technique, the separation capillaries had a diameter usually from a few hundred nanometers to a few micrometers. While high resolutions were obtained (especially for large DNA fragments), the sample injection and DNA elution were tedious, and the separation results (peak areas) were not reproducible. This was caused by the extremely low injection volumes (a few picoliters) and elution rates (<1 nanoliter per minute), which prevented us from utilizing reliable injection valves and commercial high performance liquid chromatographic pumps. In this work, we incorporate a microfabricated chip injector, and a high-pressure electroosmotic pump (EOP) to address these issues. The chip injector allows us to reliably and reproducibly inject low volumes (as low as ~1 pL) of samples into the narrow separation capillary, while the EOP provides flow rates and pressures perfectly suited for BaNC–HDC separations. Using the above system, we resolve kilo base-pair DNA fragments rapidly (in a few min) with high resolutions, and the limit of detection for double stranded DNA reaches a few molecules. The experimental parameters affecting resolutions are also discussed. Incorporation of a chip injection scheme makes automating BaNC–HDC separations readily achievable.

59 BASIC BIOLOGICAL SCIENCES↗

Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Solution‐Like Water Transport Across Molecular to Macroscopic Length Scales in Crosslinked Poly(Ethylene Glycol Diacrylate) Networks With Tailored Sidechains

Poly(ethylene glycol) (PEG)‐based materials, like PEG‐diacrylate (PEGDA), are prized for their hydrophilic, inert properties, and leveraged in hydrogels and as membrane mimics. While network chemistry is often tuned for selective transport and antifouling, fundamental understanding of water dynamics at the network surface and the impact on bulk transport is limited. We utilize Overhauser dynamic nuclear polarization (ODNP) to measure nanoscale water diffusivity near a tethered spin label at the water‐polymer surface and compare it to bulk water diffusivity from pulsed field gradient (PFG) NMR. Via active ester chemistry, spin labels and varied sidechain chemistries are introduced, modulating network hydrophilicity. Tuning network hydration through crosslinker content and functional groups further impacts water diffusivity. Results show rapid nanoscale water transport at the polymer surface, reflecting network volumetric water content, with further modulation by sidechain functionality. These findings demonstrate PEGDA's utility as a membrane mimic and the critical impact of network chemistry on water transport.

hydrogels↗

Benchtop-compatible sample processing workflow for proteome profiling of < 100 mammalian cells

Extending proteomics to smaller samples can enable the mapping of protein expression across tissues with high spatial resolution and can reveal sub-group heterogeneity. However, despite the continually improving sensitivity of LC-MS instrumentation, in-depth profiling of samples containing low-nanogram amounts of protein has remained challenging due to analyte losses incurred during preparation and analysis. To address this, we recently developed nanodroplet processing in one pot for trace samples (nanoPOTS), a robotic/microfluidic platform that generates ready-to-analyze peptides from cellular material in ~200 nL droplets with greatly reduced sample losses. In combination with ultrasensitive LC-MS, nanoPOTS has enabled >3000 proteins to be confidently identified from as few as 10 cultured human cells and ~700 proteins from single cells. However, the nanoPOTS platform requires a highly skilled operator and a costly in-house-built robotic nanopipetting instrument. In this work, we sought to evaluate the extent to which the benefits of nanodroplet processing could be preserved when upscaling reagent dispensing volumes by a factor of 10 to those addressable by commercial micropipette. We characterized the resulting platform, termed microdroplet processing in one pot for trace samples (µPOTS), for the analysis of as few as ~25 cultured HeLa cells (4 ng total protein) or 50 µm square mouse liver tissue thin sections and found that ~1800 and ~1200 unique proteins were respectively identified with high reproducibility. As such, the reduced equipment requirements should facilitate broad dissemination of nanoproteomics workflows by obviating the need for a capital-intensive custom liquid handling system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A microfabricated electroosmotic pump coupled to a gas-diffusion microchip for flow injection analysis of ammonia

Here we have microfabricated two functional components toward developing a microchip flow injection analysis (FIA) system, i.e., an open-channel electroosmotic pump and a gas-diffusion chip, consisting of two microfabricated glass wafers and a porous polytetrafluoroethylene membrane. This is the first application of gas-diffusion separation in a microchip FIA system. To demonstrate the feasibility of using these two components for performing gas-diffusion FIA, we have incorporated them together with a regular FIA injection valve and a capillary electrophoresis absorbance detector in a flow injection system for determination of ammonia in environmental water samples. This system has a limit of detection of 0.10 mg L -1 NH 3 , with a good repeatability (relative standard deviation of less than 5 % for 4.0 mg L - 1 NH 3 ). We also discuss parameters affecting its performance.

42 ENGINEERING↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗

Powering DNA strand-displacement reactions with a continuous flow reactor

Living systems require a sustained supply of energy and nutrients to survive. These nutrients are ingested, transformed into low-energy waste products, and excreted. In contrast, synthetic DNA strand-displacement reactions typically run within closed systems provided with a finite initial supply of reactants. Once the reactants are consumed, all net reactions halt and the system ceases to function. In the study, we ran DNA strand-displacement reactions in a continuous flow reactor, infusing fresh reactants and withdrawing waste, enabling the system to dynamically update its outputs in response to changing inputs. Running DNA strand-displacement reactions inside of continuous flow reactors allows the system to be re-used for multiple rounds of computation, which could enable the execution of more elaborate information processing tasks, including single-rail negation and sequential logic circuits.

59 BASIC BIOLOGICAL SCIENCES↗

Cell-machine interfaces for characterizing gene regulatory network dynamics

Gene regulatory networks and the dynamic responses theyproduce offer a wealth of information about how biologicalsystems process information about their environment.Recently, researchers interested in dissecting these networkshave been outsourcing various parts of their experimentalworkflow to computers. Here we review how, using microfluidicor optogenetic tools coupled with fluorescence imaging, it isnow possible to interface cells and computers. These platformsenable scientists to perform informative dynamic stimulationsof genetic pathways and monitor their reaction. It is alsopossible to close the loop and regulate genes in real time,providing an unprecedented view of how signals propagatethrough the network. Finally, we outline new tools that can beused within the framework of cell–machine interfaces.

59 BASIC BIOLOGICAL SCIENCES↗

Synergistic foam stabilization and transport improvement in simulated fractures with polyelectrolyte complex nanoparticles: Microscale observation using laser etched glass micromodels

Inaccessibility to direct pore scale observation in hydrocarbon recovery of tight shale formations poses a great challenge to water-energy nexus initiatives and necessitates the use of high throughput technologies to emulate environmentally friendly processes. Herein, we employ a precise glass micromodel fabrication and visualization method to isolate the supercritical CO 2 bubbles surrounded by CO 2 -water lamella prepared in saline produced water stabilized with molecular complexation of zwitterionic surfactants (ZS) and polyelectrolyte complex nanoparticles (PECNP). The Selective Laser Enhanced Etching (SLE) technique was selected for micromodel simulation of high-pressure flow. Two representative designs, (1) fracture/micro-crack network 28 and (2) fracture/matrix were etched on fused silica glass with a laser printing machine and scCO 2 foam was injected to study the foamability, propagation, stability, and fluid loss properties. The highly monodispersed and uniformly distributed array of scCO 2 bubbles were detected in flow of scCO 2 foam in highly saline brine containing ionic complexes of positively charged PECNPs and ZS, whereas foam flow with the lamella containing ZS in fractures offered a noticeably large and polydisperse array of scCO 2 bubbles. scCO 2 bubble motion and deformation were traced, and local description of foam flow was visually examined. The confined array of scCO 2 bubbles stabilized by ZS in microcracks was affected by bubble growth and coalescence, whereas the super-populated array of monodispersed scC O2 bubbles with lamella containing complexes of PECNP and ZS were able to fill the channels with stable configurations within the timeframe of comparative stability measurements. The ability of complex fluid to prevent the formation damage was evaluated through fluid loss visualization in micromodels. Probing scCO 2 foam transport in homogenous porous media revealed smaller volume leak-off for scCO 2 foam containing PECNP-ZS ionic complexes.

04 OIL SHALES AND TAR SANDS↗

Dynamic separation of gases using microsieves

Separation of light weight molecules, such as nitrogen, argon, and oxygen, from heavier compounds can have significant impacts on energy capture, environmental monitoring, or isotopic applications. Large-scale gas separation techniques, like gas centrifugation and membrane mitigation, can be problematic as they impart tremendous energy and induce high mechanical stress onto the instrumentation. Microsieves, also known as micronozzles or microfunnels, are developed to create physical barriers to separate specific isotopes and gases. Separation is achieved using a converging and diverging micronozzle to impose supersonic gas flow around a curved wall, and it has been used for the separation of heavy actinide isotopes in low weight gas as well as separation of low weight gas compositions of nitrogen and argon back in 1900s. However, systematic reviews of this unique technology are lacking. The application of the Laval style nozzle, which has a converging/diverging entrance fundamental to the micronozzle, is included in this review due to its importance in industrial applications in uranium (U) isotope refinement. Using advanced computational fluid dynamic (CFD) simulations, the extent of gas separation can be modelled. Herein, we first examine the literature and survey recent advances on fabrication techniques for creating curved micronozzles, methods and separation principles used to design devices. Furthermore, we then follow with highlights of CFD simulations applied to evaluate the separation effects using microsieves. Finally, identification of the gap and recommendation for future development and applications are suggested for using intrinsic molecular features and fluidic dynamics in formulating separation strategies.

30 Microfluidics↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

A resettable in-line particle concentrator using AC electrokinetics for distributed monitoring of microalgae in source waters

Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V. The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.

30 DIRECT ENERGY CONVERSION↗

Microfabricated Renewable Beads-Trapping/Releasing Flow Cell for Rapid Antigen-Antibody Reaction in Chemiluminescent Immunoassay

A filter pillar-array microstructure was coupled with a pneumatic micro-valve to fabricate a reusable miniaturized beads-trapping/releasing flow cell, in which trapping and releasing beads can be conveniently realized by switching the micro-valve. This miniaturized device was suitable to construct automatic fluidic system for “renewable surface analysis”. The renewable surface strategy based on pneumatic micro-valve enabled capture of beads in beads chamber prior to each assay, and release of the used beads after the assay. Chemiluminescent competitive immunoassay of 3,5,6-trichloropyridinol (TCP) was performed as a model to demonstrate the application potential of this reusable miniaturized flow cell. The whole fluidic assay process including beads trapping, immuno-binding, beads washing, beads releasing and signal collection could be completed in 10 min. Immunoassay of TCP using this miniaturized device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device had been successfully used for detection of TCP spiked in rat serum with average recovery of 97%. This investigation provides a rapid, sensitive, reusable, low-cost and automatic miniaturized device for solid-phase biochemical analysis for various purposes.

60 APPLIED LIFE SCIENCES↗

Alexa Fluor-labeled Fluorescent Cellulose Nanocrystals for Bioimaging Solid Cellulose in Spatially Structured Microenvironments

Cellulose nanocrystal materials have been labeled with modern Alexa Fluor dyes in a process that first links the dye to a cyanuric chloride molecule. Subsequent reaction with cellulose nanocrystals provides dyed solid microcrystalline cellulose material that can be used for bioimaging and suitable for deposition in films and spatially structured microenvironments. It is demonstrated with single molecular fluorescence microscopy that these films are subject to hydrolysis by cellulose enzymes.

Alexa Fluor↗

Enhanced Manganese Oxidation at the Biofilm–Fluid Interface Drives Pore-Scale Patterns in Mineral Precipitation

Microbial oxidation of manganese (Mn) from aqueous Mn(II) to solid-phase Mn(III, IV) minerals catalyzes Mn(II) removal in natural and engineered porous systems. However, little is known about the spatiotemporal evolution of Mn biomineralization in confined spaces that experience simultaneous Mn(II) delivery and Mn oxide precipitation. Here, we combine time-lapse microscopy, image analysis, and mass spectrometry to quantify the extent and rate of Mn biomineralization by Pseudomonas putida GB-1 in an optically transparent two-dimensional porous medium. We found that Mn(II) oxidation initially occurred within biofilms but shifted over time toward the edges of biofilms in contact with pore fluid. Minerals precipitated outside of the initial biofilm footprint likely due to surface-mediated oxidation of Mn(II) by nascent biogenic Mn oxides, reinforcing a gradient in mineral accumulation from the Mn(II) source near the reactor inlet to the outlet. The rate of mineral precipitation outside the biofilm footprint surpassed the rate of mineral accumulation inside biofilms within 6 h and accounted for two-thirds of the total Mn oxide mass in the pore space at the end of the experiment. This work advances a mechanistic understanding of coupled biotic and abiotic Mn oxidation in porous environments while providing a novel platform to quantify microbe-mineral-fluid interactions.

Biofilms↗