Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Non-linear Wire Rope Isolator Model to Enhance Transportation Simulation of Fragile Equipment

Abstract Introduction Wire rope isolators are often used as means of vibration isolation for the transportation of fragile machine equipment. When deployed as suspension systems in a transportation scenario, a simple spring–damper model is often used to predict the dynamic loads that act on the structure being transported. However, this simple model has proved to be too simplistic to be used in the development of an accurate numerical model that can predict the vibration levels experienced by the inner components of fragile equipment during its transportation. This paper describes the experimental tests conducted on a wire rope isolator used for the transportation of the prototype SSR1 cryomodule. Materials and methods A hysteretic Bouc–Wen model has been used to analytically describe the force–deformation relationship of the wire rope isolators. The developed model of the isolator has been implemented in a larger model to simulate the actual transportation of the prototype SSR1 cryomodule, a section of the new PIP-II linear accelerator under construction at Fermilab. A series of multibody dynamic simulations with rigid and flexible components was used to numerically determine the acceleration of some critical components. Results and conclusions An actual experimental transportation was simulated using two numerical models: the developed Bouc–Wen model and a conventional spring–damper model. It is shown how the Bouc–Wen formulation of the isolator characteristics drastically improves the correspondence between experimental and simulated results if compared to a spring–damper model, especially in the range of 0–30 Hz which is the most critical for transportation problems.

42 ENGINEERING↗

Electric System Intra-hour Operation Simulator

ESIOS is a software program developed at Pacific Northwest National Laboratory (PNNL) that performs intra-hour dispatch and automatic generation control (AGC) simulations for electric power system frequency regulation and load/variable generation following. The program dispatches generation resources at minute interval to meet control performance requirements, while incorporating stochastic models of forecast errors and variability with generation, load, interchange and market behaviors. The simulator also contains an operator model that mimics manual actions to adjust resource dispatch and maintain system reserves. Besides simulating generation fleet intra-hour dispatch, ESIOS can also be used as a test platform for the design and verification of energy storage, demand response, and other technologies helping to accommodate variable generation.

Lu, Shuai↗

Experimental and Numerical Characterization of High Temperature Deformation Behavior of 347H Stainless Steel

This study investigates how temperature affects the plasticity and thermal creep behavior of 347H stainless steel under uniaxial tension. The research combined experimental testing with advanced computational modeling. Two types of experiments were conducted: uniaxial tensile tests at temperatures from 100°C to 750°C using strain rates of ~10⁻⁴ s⁻¹, and creep tests at temperatures between 600°C and 750°C under various stress levels. These experimental results were used to develop and validate a new integrated mechanistic model that can predict material behavior under any loading condition while accounting for both stress and temperature effects. The model was implemented using a polycrystalline microstructure simulation framework based on elasto-viscoplastic Fast Fourier Transform (EVPFFT). It incorporates three key deformation mechanisms: thermally activated dislocation glide, dislocation climb, and vacancy diffusional creep. The model accounts for internal stress distribution within single crystals and considers how precipitates and solute atoms (both interstitial and substitutional) affect dislocation movement. After validation against experimental data, the model was used to generate Ashby-Weertman deformation mechanism maps for 347H steel, providing new insights into how microstructure influences the activation of different creep mechanisms.

Joy, Jobin K.↗

Compare Energy Use in Variable Refrigerant Flow Heat Pumps Field Demonstration and Computer Model

Variable Refrigerant Flow (VRF) heat pumps are often regarded as energy efficient air-conditioning systems which offer electricity savings as well as reduction in peak electric demand while providing improved individual zone setpoint control. One of the key advantages of VRF systems is minimal duct losses which provide significant reduction in energy use and duct space. However, there is limited data available to show their actual performance in the field. Since VRF systems are increasingly gaining market share in the US, it is highly desirable to have more actual field performance data of these systems. An effort was made in this direction to monitor VRF system performance over an extended period of time in a US national lab test facility. Due to increasing demand by the energy modeling community, an empirical model to simulate VRF systems was implemented in the building simulation program EnergyPlus. This paper presents the comparison of energy consumption as measured in the national lab and as predicted by the program. For increased accuracy in the comparison, a customized weather file was created by using measured outdoor temperature and relative humidity at the test facility. Other inputs to the model included building construction, VRF system model based on lab measured performance, occupancy of the building, lighting/plug loads, and thermostat set-points etc. Infiltration model inputs were adjusted in the beginning to tune the computer model and then subsequent field measurements were compared to the simulation results. Differences between the computer model results and actual field measurements are discussed. The computer generated VRF performance closely resembled the field measurements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bulk Loading Terminal Ethanol Storage, 500,000 gal, Construction

This unit process models the mass of steel plate and stainless steel used for the construction of ethanol storage tanks with a total capacity of 500,000 gallons at a bulk loading terminal. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1601A8D1-92CB-4ACF-A3DD-FDA16F97630A

03 NATURAL GAS↗

The Stress Analysis of PF1A Lower Terminals, Leads, and Bus Bars for NSTX-U

Both PF1A upper coils and lower coils experienced difficult situations during the National Spherical Torus Experiment–Upgrade (NSTX-U) machine operations in 2016. There are huge up-down electromagnetic forces on PF1A terminals, coil leads, and bus bars. Therefore, further analysis and additional reinforcement supports are needed to reduce the stress on the coil terminals and leads. Structural, thermal, and electromagnetic analyses of the three-dimensional PF1A lower bus bar and coil lead model have been performed using imported electromagnetic loads with the worst cases of 96 scenarios through the global Biot-Savart stick model. The reinforcement blocks for the PF1A lower coil leads and flags and two clamps were analyzed and installed for field testing. Finally, the coil leads and bus bars used in the field testing were qualified for the normal NSTX-U operating loads allowing similar reinforcement details to be used in the real NSTX-U machine.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demand-Side Grid (dsgrid) TEMPO Light-Duty Vehicle Charging Profiles v2022

Simulated hourly electric vehicle charging profiles for light-duty household passenger vehicles in the contiguous United States, 2018-2050. Profiles are differentiated by scenario, county, household and vehicle types, and charging type. Data was produced in 2022 using the Transportation Energy & Mobility Pathway Options (TEMPO) model and published in demand-side grid (dsgrid) toolkit format. Data are available for three adoption scenarios: "AEO Reference Case", which is aligned with the U.S. EIA Annual Energy Outlook 2018 (linked below), "EFS High Electrification", which is aligned with the High Electrification scenario of the Electrification Futures Study (linked below), and "All EV Sales by 2035", which assumes that average passenger light-duty EV sales reach 50% in 2030 and 100% in 2035. The charging shapes are derived from two key assumptions of which data users should be aware: "ubiquitous charger access", meaning that drivers of vehicles are assumed to have access to a charger whenever a trip is not in progress, and "immediate charging", meaning that immediately after trip completion, vehicles are plugged in and charge until they are either fully recharged or taken on another trip. These assumptions result in a bounding case in which vehicles' state of charge is maximized at all times. This bounding case would minimize range anxiety, but is unrealistic from the point of view of both electric vehicle service equipment (EVSE) (i.e., charger) access, and plug-in behavior as it can result in dozens of charging sessions per week for battery electric vehicles (BEVs) that in reality are often only plugged in a few times per week.

Array↗

Report on Aging and Irradiation Theoretical Model Development for Alloy 690 in Grizzly

This report describes the current efforts to implement a model to predict the engineering scale behavior of irradiated and aged Ni 2 Cr model alloy and Alloy 690 into the Grizzly software. Grizzly is a multiphysics simulation code under development at Idaho National Laboratory to simulate aging mechanisms and their effects on the integrity of critical LWR components. Engineering scale behavior of materials are strongly impacted by the underlying microstructure: the distribution and interaction of dislocations and defects within the individual grains dictates how the material will respond to loading. The evolution of these dislocations and defects determines how the engineering scale material will perform under different loading and environmental conditions. Mesoscale models can function as a bridge to connect microstructure evolution models to engineering models of the ductile-brittle transition temperature (DBTT) curve and fracture. The toughness of a material, which governs the engineering scale fracture behavior, is a function of both elastic deformation and plastic deformation. While the yield stress measurements capture the elastic contribution to a material’s toughness, information about the dislocation movement is required to understand the plastic component of toughness. Crystal plasticity models predict dislocation density evolution and thereby connect microstructure evolution to engineering scale behavior predictions. These models calculate the plastic strain within a metal as a function of dislocations and other crystal defects, including precipitates and interstitial loops, among others, by tracking dislocation movement and the interaction of these dislocations with the crystal defects. Within NiCr alloys, long-range ordered (LRO) precipitates form under aging conditions. These precipitates act as barriers to dislocation motion and are either sheared by dislocations or pin dislocations. Additional defects, such as stacking fault tetrahedra (SFTs) from irradiation damage, also impede dislocation motion in these alloys. A crystal plasticity mode for Ni 2 Cr model alloy and Alloy 690 is being currently implemented in the Grizzly code at INL. This report includes a description of the theoretical models incorporated into the Grizzly crystal plasticity code. These theoretical models include mechanisms for dislocation glade and twinning as well as dislocation-defect interaction relationship for both LRO precipitates and SFTs. We have selected these dislocation models based on the deformation mechanisms observed in experimental micropillar compression tests conducted on the Ni 2 Cr model alloy. The models are then extended to Alloy 690 with ongoing parameter fitting.

36 MATERIALS SCIENCE↗

CST Batch Contact Equilibrium Testing of TCCR Tank 10H Batch 1 and 1A Waste Supernate Samples

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with crystalline silicotitanate media to process radioactive waste solutions for the removal of Cs-137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium saltcake solids) within the tank followed by at-tank ion exchange column treatment. Equilibrium batch contact tests conducted in the SRNL Shielded Cells laboratory and associated analyses indicated that both the Tank 10H Batch 1 (pre-production) and 1A (production) waste supernates are unique solutions for which CST cesium removal performance is lower than predicted by ZAM modeling. Cesium distribution coefficients (K d ), percent removal, and CST loading data for the TCCR production supernate batch are provided in Table ES-1. ZAM-based cesium loading predictions are compared to the observed loading for the production batch in Figure ES-1, where significantly lower performance was observed than predicted by the model. Even lower cesium loading results (versus ZAM) were observed previously for the in-tank “teabag” batch contact samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Safety assessment of historical masonry churches based on pre-assigned kinematic limit analysis, FE limit and pushover analyses

This study presents some results of a comprehensive numerical analysis on three masonry churches damaged by the recent Emilia-Romagna (Italy) seismic events occurred in May 2012. The numerical study comprises: (a) pushover analyses conducted with a commercial code, standard nonlinear material models and two different horizontal load distributions; (b) FE kinematic limit analyses performed using a non-commercial software based on a preliminary homogenization of the masonry materials and a subsequent limit analysis with triangular elements and interfaces; (c) kinematic limit analyses conducted in agreement with the Italian code and based on the a-priori assumption of preassigned failure mechanisms, where the masonry material is considered unable to withstand tensile stresses. All models are capable of giving information on the active failure mechanism and the base shear at failure, which, if properly made non-dimensional with the weight of the structure, gives also an indication of the horizontal peak ground acceleration causing the collapse of the church. The results obtained from all three models indicate that the collapse is usually due to the activation of partial mechanisms (apse, façade, lateral walls, etc.). Moreover the horizontal peak ground acceleration associated to the collapse is largely lower than that required in that seismic zone by the Italian code for ordinary buildings. These outcomes highlight that structural upgrading interventions would be extremely beneficial for the considerable reduction of the seismic vulnerability of such kind of historical structures.

42 ENGINEERING↗

The performance of measurement-based simple models for the x-band complex permittivity of 370 ohms/sq. Kapton XC

The X-band complex permittivity of a commercially-available, carbon loaded, polyamide film is measured. Simple though approximate models are obtained which are shown to be necessary and suitable for analytic or computational modeling of thin absorbing structures realized with the thin lossy film. The utility of each model is tested against experimental results for thin high-impedance surface (HIS) enhanced Salisbury absorbers, enhanced in the sense that the HIS augmented absorber is much thinner than a conventional Salisbury absorber. Kapton XC(reg.) is a commercially-available, carbon-loaded polyamide film manufactured by Dupont(reg.). Though these films are exceptionally durable and available in a range of surface resistivities, their effective permittivity is complex valued and, therefore, their sheet impedance is frequency dependent as is typical of carbon-loaded dielectrics. We have measured the X-band complex permittivity of Kapton XC(reg.) with a manufacture's quoted direct current (DC) sheet resistivity of approximately 370 {Omega}/sq. and thicknesses of 40.0 {mu}m. This study showed the need for relatively precise knowledge of the real part of a carbon particulate loaded, lossy thin film's permittivity in order to accurately engineer the reflection coefficient of high-impedance surface enhanced electromagnetic absorbers. Specifically, simple, approximate models can be obtained for the X-band complex pennittivity of commercially available, carbon loaded, 370 {Omega}/sq., Kapton XC(reg.) thin film. These simple, approximate models can be used in the analytic modeling of high-impedance surface enhanced X-band absorbers or computational modeling of other possibly more complicated absorbing structures which are composed, in part, of 370 {Omega}/sq. Kapton XC(reg.) and designed to operate within the X-band. Finally, the results of this study illustrate the need for simgle models for calculating the complex permittivity spectra of 370 {Omega}/sq. Kapton XC(reg.) over a relatively broad bandwidth (1-20 GHz) to facilitate accurate analytical and computational modeling.

36 MATERIALS SCIENCE↗

On the design of magnetically insulated transmission lines for z -pinch loads

Many papers have been published on the theory of magnetic insulation and the use of Z flow analysis of magnetically insulated transmission lines (MITL’s). We describe herein a novel design process using the circuit code SCREAMER , for a real-world MITL for z-pinch loads based on the Z flow model of magnetic insulation. In particular, we design a 15-TW, 10-MA, 100 ns double-disk transmission lines using only circuit modeling tools and Z flow analysis of the MITL. Critical issues such as current loss to the anode during the setup of magnetic insulation and the transition from a non-emitting vacuum power feed to a MITL play a large role in the MITL design. This very rapid design process allows us for the first time to explore innovative MITL designs such as variable-impedance MITL’s that provide a significantly lower total inductance and improved energy delivery to the load. In conclusion the tedious process of modeling the final MITL design with highly resolved 2-D and 3-D electromagnetic particle-in-cell codes occurs as a validation step, not as part of the design process.

42 ENGINEERING↗

FAST Model Calibration and Validation of the OC5-DeepCwind Floating Offshore Wind System Against Wave Tank Test Data

During the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project, which focused on the validation of numerical methods through comparison against tank test data, the authors created a numerical FAST model of the 1:50-scale DeepCwind semisubmersible system that was tested at the Maritime Research Institute Netherlands ocean basin in 2013. The OC5 project revealed a general underprediction of loads and motions by the participating numerical models. This paper discusses several model calibration studies that were conducted to identify potential model parameter adjustments that help to improve the agreement between the numerical simulations and the experimental test data. These calibration studies cover wind-field-specific parameters (coherence, turbulence), and hydrodynamic and aerodynamic modeling approaches, as well as rotor model (blade-pitch and blade-mass imbalances) and tower model (structural tower damping coefficient) adjustments. These calibration studies were conducted based on relatively simple calibration load cases (wave only/wind only). The agreement between the final FAST model and experimental measurements is then assessed based on more complex combined wind and wave validation cases. The analysis presented in this paper does not claim to be an exhaustive parameter identification study but is aimed at describing the qualitative impact of different model parameters on the system response. This work should help to provide guidance for future systematic parameter identification and uncertainty quantification efforts.

17 WIND ENERGY↗

Load monitoring and compensation strategies for guided-waves based structural health monitoring using piezoelectric transducers

Accurate interpretation of in-situ piezoelectric sensor signals is a challenging task. This article presents the development of a numerical compensation model based on physical insight to address the influence of structural loads on piezo-sensor signals. The model requires knowledge of in-situ strain and temperature distribution in a structure while acquiring sensor signals. The parameters of the numerical model are obtained using experiments on flat aluminum plate under uniaxial tensile loading. It is shown that the model parameters obtained experimentally can be used for different structures, and sensor layout. Furthermore, the combined effects of load and temperature on the piezo-sensor response are also investigated and it is observed that both of these factors have a coupled effect on the sensor signals. It is proposed to obtain compensation model parameters under a range of operating temperatures to address this coupling effect. An important outcome of this study is a new load monitoring concept using in-situ piezoelectric sensor signals to track changes in the load paths in a structure.

environmental compensation↗

Heterogeneous climate change impacts on electricity demand in world cities circa mid-century

Rising ambient temperatures due to climate change will increase urban populations’ exposures to extreme heat. During hot hours, a key protective adaptation is increased air conditioning and associated consumption of electricity for cooling. But during cold hours, milder temperatures have the offsetting effect of reducing consumption of electricity and other fuels for heating. We elucidate the net consequences of these opposing effects in 36 cities in different world regions. We couple reduced-form statistical models of cities’ hourly responses of electric load to temperature with temporally downscaled projections of temperatures simulated by 21 global climate models (GCMs), projecting the effects of warming on the demand for electricity circa 2050. Cities' responses, temperature exposures and impacts are heterogeneous, with changes in total annual consumption ranging from –2.7 to 5.7%, and peak power demand increasing by as much as 9.5% at the multi-GCM median. The largest increases are concentrated in more economically developed mid-latitude cities, with less developed urban areas in the tropics exhibiting relatively small changes. The results highlight the important role of the structure of electricity demand: large temperature increases in tropical cities are offset by their inelastic responses, which can be attributed to lower air-conditioning penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.

Wang, Peng↗