Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “limits”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Based Method to Estimate Transformer Primary-Side Voltages with Limited Customer-Side AMI Measurements: Preprint

Distribution control applications such as volt/var optimization, network reconfiguration, and distribution automation require accurate knowledge of the distribution system state. The lack of sufficient sensors on the primary side of distribution networks often limits the accuracy of the control decisions by these applications. The deployment of advanced metering infrastructure (AMI) provides utilities an opportunity to translate the AMI data on the secondary onto the primary so that it can be used as pseudo-measurements to augment the limited existing measurements on the primary. This paper develops an approach for estimating service transformer primary-side voltages by using limited secondary-side AMI measurements. The estimated primary-side voltages can be used by utilities as pseudo-measurements for distribution control applications. The detailed secondary model topology, which is an essential input data for many existing algorithms, is not required for the proposed method. The performance of the proposed method is validated by using AMI measurements from the field and an actual distribution feeder model of San Diego Gas & Electric Company.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cascaded systems and methods for controlling energy use during a demand limiting period

A cascaded control system is configured to control power consumption of a building during a demand limiting period. The cascaded control system includes an energy use setpoint generator and a feedback controller. The energy use setpoint generator is configured to use energy pricing data and measurements of a variable condition within the building to generate an energy use setpoint during the demand limiting period. The feedback controller is configured to use a difference between the energy use setpoint and a measured energy use to generate a control signal for building equipment that operate to affect the variable condition within the building during the demand limiting period.

Wenzel, Michael J.↗

Ultimate Limit of Future Colliders

With seven operational colliders in the world and two under construction, the international particle physics community not only actively explores options for the next facilities for detailed studies of the Higgs/electroweak physics and beyond-the-LHC energy frontier, but also seeks a clear picture of the limits of the colliding beams method. In this paper, we try to consolidate various recent efforts in identifying physics limits of colliders in conjunction with societal sustainability, and share our thoughts about the perspective of reaching the ultimate collider that is at the quantum limit.

43 PARTICLE ACCELERATORS↗

Screening method for pin diodes used in microwave limiters

A method of testing a PIN diode for a power limiter circuit comprises measuring a reverse bias current of the PIN diode; applying a reverse bias voltage to the PIN diode; increasing the reverse bias voltage until the reverse bias current of the PIN diode reaches a threshold current indicative of a reverse voltage breakdown; and determining whether the reverse bias breakdown voltage of the PIN diode is within an acceptable range of reverse bias breakdown voltages corresponding to a power range at which the power limiter circuit would enter power limiting mode with the PIN diode.

Hanna, Charles John↗

Numerical and Experimental Investigations of Polyurethane Foam for Use as Cask Impact Limiter in Accidental Drop Scenarios - 12099

Rigid, closed-cell polyurethane foams are frequently used as cask impact limiters in nuclear materials and hazardous waste transport due to their high energy-absorption potential. When assessing the cask integrity in accidental scenarios based on numerical simulations, a description of the foam damping properties is required for different strain rates and for a wide temperature range with respect to waste heat generation in conjunction with critical operating and environmental conditions. Implementation and adaption of a respective finite element material model strongly relies on an appropriate experimental data base. Even though extensive impact experiments were conducted e.g. in Sandia National Laboratories, Savannah River National Laboratory and by Rolls Royce plc, not all relevant factors were taken into account. Hence, BAM who is in charge of the mechanical evaluation of such packages within the approval procedure in Germany, incorporated systematic test series into a comprehensive research project aimed to develop numerical methods for a couple of damping materials. In a first step, displacement driven compression tests have been performed on confined, cubic specimens at five loading rates ranging from 0.02 mm/s to 3 m/s at temperatures between +90 deg. C and -40 deg. C. Materials include two different polyurethane foam types called FR3718 and FR3730 having densities of 280 kg/m{sup 3} and 488 kg/m{sup 3} from the product line-up of General Plastics Manufacturing Company. Their data was used to adapt an advanced plasticity model allowing for reliably simulating cellular materials under multi-axial compression states. Therefore, an automated parameter identification procedure had been established by combining an artificial neural network with local optimization techniques. Currently, the selected numerical material input values are validated and optimized by means of more complex loading configurations with the prospect of establishing methods applicable to impact limiters under severe accidental conditions. The reference data base is provided by experiments, where weights between 212 kg and 1200 kg have been dropped from heights between 1.25 m and 7 m on confined 10 cm cubic foam specimens. By presenting the deviations between experimental values and the corresponding output of finite element simulations, the potentials and restrictions of the resulting models are highlighted. Systematic compression tests on polyurethane foams had been performed at BAM test site within the framework of a research project on impact limiters for handling casks for radioactive waste. The experimental results had been used to adapt numerical models for simulating the behaviour of different foam types at different temperatures. The loading speed, however, turned out to have a major influence on their flow curves that can not be captured by simple strain-rate dependent multipliers. Especially for guided drop tests that come close to real accidental scenarios there is a significant gap between experimental and numerical results even when applying such advanced material models. Hence, the extensive data base is currently deployed for expanding the standard algorithms to include adequate dynamic hardening factors. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effect of the Presence of Ozone on the Lower Flammability Limit (LFL) of Hydrogen in Vessels Containing Savannah River Site High Level Waste - 12387

The Enhanced Chemical Cleaning (ECC) process uses ozone to effect the oxidation of metal oxalates produced during the dissolution of sludge in the Savannah River Site (SRS) waste tanks. The ozone reacts with the metal oxalates to form metal oxide and hydroxide precipitants, and the CO{sub 2}, O{sub 2}, H{sub 2}O and any unreacted O{sub 3} gases are discharged into the vapor space. In addition to the non-radioactive metals in the waste, however, the SRS radioactive waste also contains a variety of radionuclides, hence, hydrogen gas is also present in the vapor space of the ECC system. Because hydrogen is flammable, the impact of this resultant gas stream on the Lower Flammability Limit (LFL) of hydrogen must be understood for all possible operating scenarios of both normal and off-normal situations, with particular emphasis at the elevated temperatures and pressures of the typical ECC operating conditions. Oxygen is a known accelerant in combustion reactions, but while there are data associated with the behavior of hydrogen/oxygen environments, recent, relevant studies addressing the effect of ozone on the flammability limit of hydrogen proved scarce. Further, discussions with industry experts verified the absence of data in this area and indicated that laboratory testing, specific to defined operating parameters, was needed to comprehensively address the issue. Testing was thus designed and commissioned to provide the data necessary to support safety related considerations for the ECC process. A test matrix was developed to envelope the bounding conditions considered credible during ECC processing. Each test consists of combining a gas stream of high purity hydrogen with a gas stream comprised of a specified mixture of ozone and oxygen in a temperature and pressure regulated chamber such that the relative compositions of the two streams are controlled. The gases are then stirred to obtain a homogeneous mixture and ignition attempted by applying 10J of energy to a fuse wire. A gas combination is considered flammable when a pressure rise of 7% of the initial absolute pressure is observed. The specified testing methodology is consistent with guidelines established in ASTM E-918-83 (2005) 'Standard Practices for Determining Limits of Flammability of Chemicals at Elevated Temperature and Pressure'. The LFL of hydrogen in air was determined and is in good agreement with the literature data. Ozone-oxygen mixtures were found to be flammable at concentrations above 8.3 vol.% based on the ASTM E918 7% pressure rise criteria for flame propagation. This result is lower than previously reported values which can be explained through the variations in the test setup and procedure. It is believed that the lower values obtained in this work are a result of improvements of the test methodology. Tests performed with hydrogen in various concentrations of ozone in oxygen have shown that the LFL of hydrogen decreases as the concentration of ozone in the mixture increases. This testing was designed to provide data under the conditions considered most optimal to produce deflagration. The geometry and materials of construction of the testing vessel; the location of the fuse wire; the magnitude of the supplied energy; the careful minimization of diluents and other contaminants; and meticulous procedural detail to maintain integrity of the ozone to the maximum extent practical, result in data that reflect not the expected process conditions, but those that enhance the possibility of flame propagation. For this reason, there is believed to be considerable conservatism in the indicated results. Per the vendor, the maximum possible ozone concentration producible by the planned ECC Ozone generator is 8 volume percent (the typical maximum operating setpoint concentration is 6.8 vol%), less than the 8.3 minimum volume % concentration shown to be flammable in a 99.999% pure O{sub 2} environment at the optimally conservative conditions established in this testing. Further, the feed to the ECC ozone generator is only 87% oxygen, the remainder, water vapor and nitrogen, both powerful diluents. It is, thus, believed not credible that deflagration can occur at this maximum feed concentration condition. In addition, once the ozone stream contacts the waste stream, the many simultaneous oxidizing reactions will rapidly decompose available ozone to well below flammable levels. Further, because the radiolytically generated hydrogen quantity is negligible compared to the supplied ozone/oxygen stream (0.0004 moles per minute H{sub 2} vs 76 moles per minute ozone/oxygen), even the total H{sub 2}/O{sub 3} mixture, without crediting decomposition reactions, does not approach flammable concentrations. Finally, even at the 'end' of the ECC batch cycle, when most of the metal oxalates have been decomposed, testing has indicated that the ozone concentration in the vapor space of the ECC process vessel reaches a concentration of no more than 3 vol%, remaining well below concentrations of concern. The major issue for the ECC operation established by this testing is the impact of the data when applied to off normal conditions. While it is possible to discontinue ozone addition to the reaction vessel at any time, the radiolytic hydrogen generation rate continues, varying slightly as ambient pressures and temperatures change. Relative to the data generated and analyzed in this testing, the ECC hazards analysis team will re-evaluate off normal conditions (e.g. those during which process exhaust ventilation is lost) such that issues involving mixtures of hydrogen and ozone in the vapor space can be appropriately controlled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring, Cutting and Sorting Irradiated Control Rods to Limit the Volume of Intermediate Level Long-lived Waste - 17001

During operation, the PWR control rods are either completely extracted (scram or safety rods) or partially inserted in the operating zone of the core (fine control or operating rods). At the nominal rating conditions or close to them, the operating zone is limited to some steps of insertion in the order of a few tens of cm. In fact, only the lower part of the control rods are subjected to a significant neutron flux with an impact on the neutron activation and so on the waste classification (Low Level Short-lived Waste versus Intermediate Level Long-lived Waste). Our calculative as well as experimental experience confirms the significant presence of radionuclides in the control rods, but only in the lower parts. Measuring, cutting and finally sorting control rod scraps can reduce the volume of Intermediate Level Long-lived Waste planned for our storage deposit facility. This paper presents the EDF/DP2D methodologies followed to determine the sort criteria between the Low Level Short-lived Waste versus the Intermediate Level Long-lived Waste zones for the Silver-Indium-Cadmium control rods. The irradiated control rods are stored in cases without their head. Each case can contain several control rods, and the cases are stored under water in the fuel assembly pool. To calculate the radioactive inventories, we have developed a calculation scheme which is composed of a 3-dimensional mapping of the neutron flux, a calculation of the evolution of the isotopic compositions under neutron flux and finally a comparison between calculated and measured values. The main hypotheses of the control rods calculation take into account: - 3-dimensional geometry and 3-dimensional neutron sources distribution, - the isotopic compositions including impurities, - the history of irradiation resulting mainly from the daily power production, the positions of the control rods in the loading patterns and the positions in the axial operating zone. In order to validate the calculations, measurements were made 20 meters under water in the fuel assembly pool. The experimental results show the presence of many gamma emitter radionuclides. Only Ag-108m was retained for validating the calculations. This is due to the fact that silver is considered as the 'standard' chemical element for our control rods and silver produces Ag-108m which is a long-lived gamma emitter radionuclide. The analysis of the calculated results and the measured values allow us to build a simplified physics model for the simulation of the control rods activation. Finally three sort criteria can be proposed: - Without measurement devices, the sorting is based on an empirical sort criterion. Cuttings must then be made on the 2 back-ends of the control rod pins. This option is due to the difficulty in knowing the orientation of the pins in the storage cases. The cutting lines are placed at approximately 1 m from the 2 back-ends of the pins. This approach does not allow a great optimization of the sorting, less than 50% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With a simple dose rate measurement device, the knowledge of the orientation of the pins in the storage cases allows us to limit cuttings to the lower part of the control rods. Depending on the 'top to tail' cases, between approximately 50% and 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. - With an accurate measurement device, the sorting can be based on a specific activity of Ag-108m. Over 4400 Bq/g of Ag-108m (corresponding to the Intermediate Level Long-lived Waste limit), the control rod pieces can be considered as a long-lived waste. The measurements must be made over the 2 back-ends of control rod pins to examine the cases of 'top to tail' storage. This approach allows a great optimization of the sorting. Depending on the history of irradiation, more than 75% of the length of the control rods can be saved from Intermediate Level Long-lived Waste storage. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

limiting rods selection in large break LOCA analysis with the RELAP5-3D code

The Nuclear Regulatory Commission (NRC) is proposing a new rulemaking on emergency core system/loss-of-coolant accident (LOCA) performance analysis. In the proposed rulemaking, designated as 10 CFR 50.46(c), the US NRC put forward an equivalent cladding oxidation criterion as a function of cladding pre-transient hydrogen content. The proposed rulemaking imposes more restrictive and burnup-dependent cladding embrittlement criteria; consequently more fuel rods need to be analyzed under LOCA conditions to maintain the safety margin, compared to the current practice in which only one hot rod needs to be analyzed. New analysis methods are required to provide a thorough characterization of the reactor core in order to identify the locations of the limiting rods under LOCA conditions. In this work, the best-estimate plus uncertainty analysis capability for large break LOCA with the new cladding embrittlement criteria using the RELAP5-3D code is established and demonstrated with a reduced set of uncertainty parameters. With the new analysis method, the limiting transient case and the limiting rods can be easily identified in response to the proposed new rulemaking. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

WIPP Space Faces TRU Waste Disposal Limits; The Volume Reducing Solution - 18365

Transuranic (TRU) waste packaging for removal from a glovebox has for many years involved the use of bags as the primary containment. In many cases, many hydrogenous layers of bags, yards of tape, and multiple filters are added to the waste stream in order to get the TRU waste into the final 55 gallon drum package to be shipped and buried at the Waste Isolation Pilot Plant (WIPP). The WIPP is currently limited to a total finite disposed volume of Contact Handled (CH) and Remote Handled (RH) TRU waste. As of early 2014 over half of the allotted WIPP volume had been filled with mainly CH-TRU waste. Based on current bag operation packaging methods used, the Department of Energy's (DOE) remaining CH and RH waste will not fit in the remaining limited WIPP space. Bag operations, can be performed safely by good operators following tedious repetitive processes and many Administrative Safety Controls. Since the bag is the only confinement layer between the contamination and the operator, contamination incidents can occur. Bag-out operations require close proximity to the waste to perform the process. With some waste streams, this close to waste proximity increases operator radiation dose. Central Research Laboratories (CRL), based in Red Wing Minnesota, who for many decades has developed proven engineered material transfer solutions based around their Rapid Transfer Port (RTP) technology, has worked with DOE sites to develop a TRU Waste Management Solution. The solution is a single filtered large Polyethylene (PE) or Stainless Steel (SST) Rapid Transfer Port container in a standard Department of Transportation (DOT) 7A, Type A drum, which allows for loading of TRU waste directly from the operational glovebox without the use of bags, sleeves or tapes to provide leak tight containment. All operator interventions to connect and disconnect a drum to and from the glovebox are achieved in an upright ergonomic position by one (1) operator in less than three (3) minutes. Minimal As Low As Reasonably Achievable (ALARA) levels are achieved during connect and disconnect of the drum, due to the engineered safety controls of the RTP. The CRL RTP solution allows glovebox or re-packaged TRU waste to be safely transferred to the final 55 Gallon drum container without additional bags or tape. The high diffusion coefficient filter on the CRL RTP 55G container and elimination of added hydrogenous packaging, improves the Decay Heat Limit (DHL) per drum for most TRU waste types compared with bagged drums, and in most cases allows more TRU waste to be loaded per drum. Inorganic TRU waste materials can be packaged directly into the CRL RTP SST drum container to the maximum DHL and Fissile Gram Equivalent (FGE) allowable for a drum. This paper will show how highly efficient TRAMPAC approved TRU waste packaging of CH and RH TRU waste can be accomplished in a safer, cost effective manner without adding any additional packaging materials to the waste stream, thus increasing the chance of placing all DOE's legacy and to be generated TRU waste in the remaining WIPP space. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Criticality hazard identification technique for development of safe operating limits and restrictions - 14367

Canadian Nuclear Laboratories' (CNL) National Research Universal (NRU) reactor located at Chalk River Laboratories (CRL) first attained criticality in 1957. Outside of the reactor core, the safe handling and storage of fissile material including experimental fuel components is required to support NRU's ongoing missions of research and medical isotope production [1]. Management of this fissionable material relies heavily on experienced operating staff, who perform work in accordance with a defined set of limits and restrictions as laid out in a Criticality Safety Document (CSD). Historically, the development of CSDs has relied heavily upon criticality safety analysts to gain sufficient knowledge about the facility. This has resulted in significant labor costs due to heavy use of computational methods. This paper describes a new approach for CNL to identify potential criticality scenarios, a 'Criticality Hazard Identification' (CHI) technique, developed from traditional process-oriented hazard and operability analysis, to identify and define operating conditions, identify limits and restrictions for the handling of fissionable materials outside of the core. The approach permits thorough evaluation of potential criticality hazards, for both well-understood historical and proposed future activities, by better leveraging the knowledge of operations personnel as well as other subject matter experts. The resulting document provides a detailed record of the various scenarios that were considered. These improvements to the CSD development and documentation process provide an additional benefit in terms of ease of modification to include new or changed activities within the limits and conditions. (authors)

42 ENGINEERING↗

Atalante research facility new mass limits in a unit containing plutonium and minor actinides - 14402

ATALANTE, located in Marcoule, is one of the main Nuclear Facilities of the French Alternative Energies and Atomic Energy Commission (CEA). This facility is mainly dedicated to research and development for nuclear energy related to the back end of the fuel cycle: spent fuel and final waste management. It is a large research complex housing chemistry and analytical laboratories and shielded cells (240 glove boxes and 11 shielded cells), equipped for basic studies through to demonstration experiments. Within the facility, one unit can contain plutonium and curium at the same time. In this case, nuclear criticality safety is achieved by exercising control over mass. A subcritical mass limit is defined for plutonium (280 g for {sup 239}Pu) and an exemption mass limit (3 g for {sup 245}Cm) is used for the actinide. In order to increase the maximum mass (in particular {sup 245}Cm) which can be handled in the unit, new mass control limits were studied, based on control over the sum of the mass ratio to the upper subcritical mass, noted m{sub lim}, for each nuclide (350 g for {sup 239}Pu; 34.8 g or 23 g for {sup 245}Cm) as shown in equation (1) below. m({sup 239}Pu)/ m{sub lim}({sup 239}Pu)+ m({sup 245}Cm)/m{sub lim}({sup 245}Cm)≤1 (1) To validate this criticality safety control method, a study was conducted to demonstrate that, for different masses of {sup 239}Pu and {sup 245}Cm meeting equation (1), the calculated effective multiplication factor is always lower than the effective multiplication factor corresponding to a sphere of 350 g of pure {sup 239}Pu, moderated, with 20 cm water reflection. The two pseudo fissile media are: - metallic plutonium (100% {sup 239}Pu, density 19.86), moderated with water, - metallic curium (100% {sup 245}Cm, density 13.566), moderated with water. The calculation model is a sphere of {sup 245}Cm metal positioned in a sphere of {sup 239}Pu metal, with optimum moderation for each fissile material, and a full water reflection (20 cm). The results show that, under certain conditions, the effective multiplication factor of the mixture can be higher than the effective multiplication factor of each pure fissile material when using the upper subcritical mass of 34.8 g for {sup 245}Cm. When using 23 g of {sup 245}Cm, the k{sub eff} of the mixture is always lower than the k{sub eff} of pure {sup 239}Pu. These calculations enable the safety documentation to be changed by introducing a new process operational procedure, based on equation (1). This change in procedure allows the operator to work with a larger quantity of curium in the unit. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Transmission Interface Limits for High-Spatial Resolution Capacity Expansion Modeling

Large-scale capacity expansion models typically rely on estimates of the power transfer limits between modeled zones. Accurate estimation of these interface transfer limits (ITLs) requires modeling the underlying transmission network. Here we expand on a maximum flow optimization method that uses linearized power flow to estimate transfer limits. We apply this method to a data set of the U.S. transmission network to estimate ITLs between U.S. counties. By calculating ITLs using different subsets of the network, we evaluate how the size of the network used in the estimation affects the results. The results show diminishing returns to ITL accuracy after six hops, suggesting that a network subset can reasonably be used to approximate ITLs. The county-level estimates produced in this study will support more spatially resolved capacity expansion modeling and will help inform policy making at local and national levels.

capacity planning↗

Strong-Drive Limits in Josephson Circuits: From Chaos to an Unbound-Resonance Threshold

Strong microwave drives enable fast measurement and parametric control in superconducting circuits but can induce transitions out of the intended low-energy manifold. We develop a unified description of strong-drive limits in flux- and charge-driven Josephson circuits across drive frequency and dc flux bias. Using classical phase-space analysis and Floquet--Markov simulations, we identify distinct low- and high-frequency mechanisms. At low frequency, we characterize bound-state resonances and separatrix chaos and find that the flux-drive chaos threshold depends strongly on dc flux bias. At high frequency, these mechanisms are suppressed, and the dissipative steady state transfers from the central bound-state sector to outer resonances formed by above-barrier running trajectories. The resulting unbound-resonance threshold is nearly independent of drive frequency and circuit parameters over the regime studied and is controlled primarily by dc flux bias. Coherent simulations show that parametric operation persists beyond this threshold, but at a reduced rate, setting an effective upper bound on the achievable operation speed. We derive analytical criteria for both thresholds, validate them numerically, and experimentally confirm the predicted dc-bias dependence of the low-frequency threshold in a flux-driven SQUID. We also determine the timescales for transfer into the unbound-resonance regime and relaxation back to the bound-state manifold after the drive is removed. Finally, we relate the stability limits to a complementary picture based on the junction critical current and extend the framework to multitone drives and inductively shunted circuits. Together, these results identify the mechanisms limiting strong driving and suggest routes to extend the stable operating range of Josephson circuits.

You, Xinyuan [Fermilab] (ORCID:0000000291789419)↗

Gradient limitations in room temperature and superconducting acceleration structures

Accelerating gradient is a key parameter of the accelerating structure in large linac facilities, like future Linear Collider. In room temperature accelerating structures the gradient is limited mostly by breakdown phenomena, caused by high surface electric fields or pulse surface heating. High power processing is a necessary procedure to clean surface and improve the gradient. In the best tested X-band structures the achieved gradient is exceed 100 MV/m in of {approx}200 ns pulses for breakdown rate of {approx} 10{sup -7}. Gradient limit depends on number of factors and no one theory which can explain all sets of experimental results and predict gradient in new accelerating structure. In paper we briefly overview the recent experimental results of breakdown studies, progress in understanding of gradient limitations and scaling laws. Although superconducting rf technology has been adopted throughout the world for ILC, it has frequently been difficult to reach the predicted performance in these structures due to a number of factors: multipactoring, field emission, Q-slope, thermal breakdown. In paper we are discussing all these phenomena and the ways to increase accelerating gradient in SC cavity, which are a part of worldwide R&D program.

43 PARTICLE ACCELERATORS↗

INVESTIGATING SCALING LIMITS OF A FIBER BASED RESONANT PROBE FOR METROLOGY APPLICATIONS

Currently, Inertial Confinement Fusion (ICF) and High Energy Density Science (HEDS) targets comprise components with dimensions in the millimeter range, while having micrometerscale, high aspect ratio functional features, including fill-tube holes and counterbores, slotted patterns, and step-joint geometry on hemispherical targets. Representative geometry is shown in Figure 1. Future target designs will likely have additional challenging features. The dimensional metrology of these features is important for a number of reasons, including quantifying geometrical tolerances of as-built components prior to delivery, qualification of sub-components prior to assembly, and as a feedback mechanism for fabrication process development. Variations in geometry from part to part can lead to functional limitations, such as limited flow rates during target filling, unpredictable instabilities during an experiment, and the inability to assemble a target from poorly matched sub-components. Adding to the complexity are the large number and variety of materials, components, and shapes that render any single metrology technique difficult to use with low uncertainty. Adapting standing wave probe technology [i] for micrometer sized features requires the understanding of the physical interaction between the oscillating, slender rod (probe) and the sample as a means of transferring information about the surface, such as topography and material properties, analogous to tapping mode atomic force microscopy (AFM) and/or instrumented indentation machines. By utilizing the variation in dynamic response of the probe as the tip interacts with a surface, information about the sample may be obtained and used for mapping surface topography, and potentially characterizing material properties. The novel long aspect ratio geometry of the probe enables the characterization of features such as small holes, slots, and corners, which typically cannot be accessed using AFM and instrumented indentation technology. Uncertainty of the surface location is a combination of near surface effects such as van der Waals and electrostatic forces combined with contact force such adhesion and meniscus contributions. In addition, environmental effects, such as thermal gradients and air turbulence, will influence probe performance and repeatability. A combination of complex nonlinear models of the tuning fork driver/sensor mechanics, fiber dynamics, circuit response and contact interactions have been developed for the current scale system in an effort to predict scaling limitations of this technology for characterizing micrometer sized features with nanometer sensitivity.

42 ENGINEERING↗