Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Discovery of Soft X-Ray Emission from Io, Europa and the Io Plasma Torus

The Chandra X-ray Observatory observed the Jovian system for about 24 hours on 25-26 Nov 1999 with the Advanced CCD Imaging Spectrometer (ACIS), in support of the Galileo flyby of Io, and for about 10 hours on 18 Dec 2000 with the imaging array of the High Resolution Camera (HRC-I), in support of the Cassini flyby of Jupiter. Analysis of these data have revealed soft (0.25--2 keV) x-ray emission from the moons Io and Europa, probably Ganymede, and from the Io Plasma Torus (IPT). Bombardment by energetic (greater than 10 keV) H, O, and S ions from the region of the IPT seems the likely source of the x-ray emission from the Galilean moons. According to our estimates, fluorescent x-ray emission excited by solar x-rays is about an order of magnitude too weak even during flares from the active Sun to account for the observed x-ray flux from the IPT. Charge-exchange processes, previously invoked to explain Jupiter's x-ray aurora and cometary x-ray emission, and ion stripping by dust grains both fall by orders of magnitude. On the other hand, we calculate that bremsstrahlung emission of soft X-rays from non-thermal electrons in the few hundred to few thousand eV range accounts for roughly one third of the observed x-ray flux from the IPT. Extension of the far ultraviolet (FUV) IPT spectrum likely also contributes.

Elsner, R. F.↗

Evidence for electron energization accompanying spontaneous formation of ion acceleration regions in expanding plasmas

We report experiments conducted in an expanding argon plasma generated in the inductive mode of a helicon source in the Hot hELIcon eXperiment–Large Experiment on Instabilities and Anisotropies facility. As the neutral gas pressure increases, the supersonic ion acceleration weakens. Increasing neutral pressure also alters the radial profile of electron temperature, density, and plasma potential upstream of the plasma expansion region. Langmuir probe measurements of the electron energy probability function (EEPF) show that heating of electrons at the plasma edge by RF fields diminishes with increasing gas pressure, yielding a plasma with a centrally peaked electron temperature, and flat potential profiles at higher neutral pressures. For neutral pressures at which ion acceleration regions develop in the expanding plasma plume, EEPFs reveal electrons with two temperature components.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Oxygen in the heliosphere

Oxygen within the heliosphere, whether neutral or ionized, comes from both the external source in the local interstellar medium (LISM) and internal sources. If transient cometary sources are neglected, Jupiter is the strongest of the internal sources by virtue of its corotation and charge exchange driven neutral wind. O(+) pickup ions are born where the penetrating neutrals lose an electron as a result of photoionization, charge exchange with solar wind protons, or solar wind electron impact ionization. The region of the heliosphere from which these pickup ions arise depends on the phase of the solar cycle as well as on the velocities of the neutrals. The present model of neutral O populations and their ionization suggests that Jovian pickup ions can dominate the inner heliospheric O(+) population if the LISM neutrals are strongly filtered at the heliopause, or are excluded by strong ionizing fluxes from the Sun. Other heliospheric species such as sulfur and nitrogen may have similar origins. These planetary sources need to be taken into account in the interpretation of interplanetary gas and ion composition observations.

Luhmann, J. G.↗

Energy transfer between energetic ring current H(+) and O(+) by electromagnetic ion cyclotron waves

Electromagnetic ion cyclotron (EMIC) waves in the frequency range below the helium gyrofrequency can be excited in the equatorial region of the outer magnetosphere by cyclotron resonant instability with anisotropic ring current H(+) ions. As the unducted waves propagate to higher latitudes, the wave normal should become highly inclined to the ambient magnetic field. Under such conditions, wave energy can be absorbed by cyclotron resonant interactions with ambient O(+), leading to ion heating perpendicular to the ambient magnetic field. Resonant wave absorption peaks in the vicinity of the bi-ion frequency and the second harmonic of the O(+) gyrofrequrency. This absorption should mainly occur at latitudes between 10 deg and 30 deg along auroral field lines (L is greater than or equal to 7) in the postnoon sector. The concomitant ion heating perpendicular to the ambient magnetic field can contribute to the isotropization and geomagnetic trapping of collapsed O(+) ion conics (or beams) that originate from a low-altitude ionospheric source region. During geomagnetic storms when the O(+) content of the magnetosphere is significantly enhanced, the absorption of EMIC waves should become more efficient, and it may contribute to the observed acceleration of O(+) ions of ionospheric origin up to ring current energies.

Thorne, Richard M.↗

Orion Portable Fire Extinguisher Performance Testing Against a Laptop Lithium-Ion Battery Stored-Energy Fire-Method, Magnesium Fires, and Combustion By-Product Toxicity

As part of the qualification of the International Space Station (ISS) fine water mist portable fire extinguisher (PFE), several test methods were developed to determine firefighting capability against stored-energy sources. The most challenging of these devised stored-energy fire test methods proved to be the Lithium-ion (Li-ion) battery fire test scenario. The Orion crew capsule will utilize a different PFE technology from ISS (water spray rather than water mist), which spurred the need for the same type of evaluation focused on the sources of stored energy slated for use on Orion. Laptops were identified as a realistic source for stored-energy fires, requiring a modified Li-ion battery fire test scenario. In addition to open test cell (ambient oxygen concentration) testing to evaluate new proposed PFE performance, sealed chamber (20.9% and elevated oxygen concentration) testing was also performed. Chamber testing included combustion product sampling at various fire progression points for analysis and application to Orion emergency equipment design and response planning. The PFE stored-energy fire test methodology was modified and testing performed. Initial tests indicated ignition of the laptop magnesium laptop cases was possible. Additional tests were performed to characterize the laptop magnesium case fire behavior in various configurations. The new water spray PFE technology proved effective in extinguishing laptop stored-energy fires, and much was learned in the way these types of fires progressed. Findings indicate potential laptop magnesium case ignition mitigation strategies need to be further investigated.

Harper, Susana A.↗

Ions with low charges in the solar wind as measured by SWICS on board Ulysses

We present new data on rare ions in the solar wind. Using the Ulysses-SWICS instrument with its very low background we have searched for low-charge ions during a 6-d period of low-speed solar wind and established sensitive upper limits for many species. In the solar wind, we found He(1+)/He(2+) of less than 5 x 10 exp -4. This result and the charge state distributions of heavier elements indicate that all components of the investigated ion population went through a regular coronal expansion and experienced the typical electron temperatures of 1 to 2 million Kelvin. We argue that the virtual absence of low-charge ions demonstrates a very low level of nonsolar contamination in the source region of the solar wind sample we studied. Since this sample showed the FlP effect typical for low-speed solar wind, i.e., an enhancement in the abundances of elements with low first ionization potential, we conclude that this enhancement was caused by an ion-atom separation mechanism operating near the solar surface and not by foreign material in the corona.

Geiss, J.↗

Design of An Improved Miniature Ion Neutral Mass Spectrometer for NASA Applications

The ion optics of NASA's Ion Neutral Mass Spectrometer (INMS) sensor was simulated with three dimensional models of the open source, the quadrupole deflector, the exit lens system and the quadrupole mass analyzer to design more compact models with lower weight. Comparison of calculated transmission with experimental results shows good agreement. Transmission analyses with varying geometrical parameters and voltages throw light on possible ways of reducing the size of the sensor. Trajectories of ions of mass 1-99 amu were simulated to analyze and optimize transmission. Analysis of open source transmission with varying angle of attack shows that the angular acceptance can be considerably increased by programming the voltages on the ion trap/ collimator. Analysis of transmission sensitivity to voltages and misalignments of the quadrupole deflector rods indicate that increased transmission is possible with a geometrically asymmetrical deflector and a deflector can be designed with much lower sensitivities of transmission. Bringing the disks closer together can decrease the size of the quadrupole deflector and also increase transmission. The exit lens system can be redesigned to be smaller by eliminating at least one electrode entirely without loss of transmission. Ceramic materials were investigated to find suitable candidates for use in the construction of lighter weight mass spectrometer. A high-sensitivity, high-resolution portable gas chromatograph mass spectrometer with a mass range of 2-700 amu has been built and will be commercialized in Phase 3.

Swaminathan, Viji K.↗

Energy Storage Grand Challenge: Energy Storage Market Report

As part of the Department of Energy's (DOE) Energy Storage Grand Challenge (ESGC), DOE intends to synthesize and disseminate best available energy storage data, information, and analysis to inform decision-making and accelerate technology adoption. The ESGC Roadmap provides options for addressing technology development, commercialization, manufacturing, valuation, and workforce challenges to position the United States for global leadership in the energy storage technologies of the future. This report provides a baseline understanding of the numerous, dynamic energy storage markets that fall within the scope of the ESGC via an integrated presentation of deployment, investment, and manufacturing data from the best, publicly-available sources. This report covers the following energy storage technologies: lithium ion batteries, lead acid batteries, pumped storage hydropower, comrpessed air energy storage, redox flow batteries, hydrogen, building thermal energy storage, and select long duration energy storage technologies. Not all energy storage technologies and markets could be addressed in this report. Due to the wide array of energy technologies, market niches, and data availability issues, this market report only included a select group of technologies. For example, thermal energy storage technologies are very broadly defined and cover a wide range of potential markets, technology readiness levels, and primary energy sources. In other areas, data scarcity necessitates a greater understanding of future applications and emerging science. Future efforts will update data presented in this report and be expanded to include other energy storage technologies. This data-driven assessment of the current status of energy storage markets is essential to track progress toward the goals described in the Energy Storage Grand Challenge and inform the decision-making of a broad range of stakeholders. At the same time, gaps identified through the development of this report can point to areas where further data collection and analysis could provide an even greater level of understanding of the full range of markets and technologies. Finally, numerous complementary analyses are planned, underway, or completed that will provide a deeper understanding of the specific technologies and markets covered at a high-level in this report.

25 ENERGY STORAGE↗

Development of a position–velocity–time-modulated two-dimensional ion beam figuring system for synchrotron x-ray mirror fabrication

With the rapid evolution of synchrotron x-ray sources, the demand for high-quality precision x-ray mirrors has greatly increased. Single nanometer shape accuracy is required to keep imaging capabilities at the diffraction limit. Ion beam figuring (IBF) has been used frequently for ultra-precision finishing of mirrors, but achieving the ultimate accuracy depends on three important points: careful alignment, accurate dwell time calculation and implementation, and accurate optical metrology. The Optical Metrology Group at National Synchrotron Light Source II has designed and built a position–velocity–time-modulated two-dimensional IBF system (PVT-IBF) with three novel characteristics: (1) a beam footprint on the mirror was used as a reference to align the coordinate systems between the metrology and the IBF hardware; (2) the robust iterative Fourier transform-based dwell time algorithm proposed by our group was applied to obtain an accurate dwell time map; and (3) the dwell time was then transformed to velocities and implemented with the PVT motion scheme. In this study, the technical aspects of the PVT-IBF systems are described in detail, followed by an experimental demonstration of the figuring results. In our first experiment, the 2D RMS in a 50mm×5mm clear aperture was reduced from 3.4 to 1.1 nm after one IBF run. In our second experiment, due to a 5 mm pinhole installed in front of the source, the 2D RMS in a 50mm×5mm clear aperture was reduced from 39.1 to 1.9 nm after three IBF runs, demonstrating that our PVT-IBF solution is an effective and deterministic figuring process.

47 OTHER INSTRUMENTATION↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Activation, Dehydrogenation, and Carbon–Carbon Coupling of Methane by Iridium Cations Studied by Infrared Multiple Photon Dissociation Spectroscopy and Density Functional Theory

Products resulting from the sequential activation of one, two, three, and four methane molecules by atomic iridium cations were characterized by gas-phase infrared multiple photon dissociation spectroscopy and density functional theory (DFT) calculations. Iridium cations were generated using a laser ablation source and reacted with methane in a linear radiofrequency ion trap before mass analysis and spectroscopic interrogation in a Fourier transform ion cyclotron resonance mass spectrometer coupled to the free-electron laser for intracavity experiments (FELICE) beamline. Product ions were irradiated using infrared light over the 250–1500 cm –1 range. Comparisons between the experimental and DFT-calculated spectra enabled structural determination of the products formed. The observed products include HIrCH + , Ir(CH 2 ) 2 + , H s Ir(C 3 H 5 ) + , and Ir(CH 3 ) s (C 3 H 5 ) + , where the subscript s denotes a syn orientation of the two ligands. Furthermore, formation of the latter two products provides evidence for efficient C–H bond activation and subsequent C–C coupling on the atomic iridium cation.

Chemical reactions↗

Selective Binding and Light-Driven Release of Fluorous PF 6 – and Radioactive 99 TcO 4 – Anions for All-to-Nothing Liquid–Liquid Extraction

The removal of anions from aqueous media using molecular receptors in liquid–liquid extraction is a long-standing strategy to clean up contaminated water sources. Therein, high selectivity is needed to remove specific ions from mixtures of other ions, and high affinity provides extractions at low concentrations. However, the high affinity creates a conundrum by impeding the release of the ions in any stripping steps needed for further processing. To circumvent this problem, light-responsive receptors have been proposed as candidates for turning off the binding, but they are currently untested in liquid–liquid extraction. We tested the feasibility of light-driven release using a cyanostar macrocycle. We demonstrate the selective extraction of PF$^{–}_{6}$ anions over large excesses of competing anions (Cl – , NO$^{–}_{3}$, SO$^{2–}_{4}$) followed by photodriven release for quantitative isolation of the target. Release relies on photoisomerization of the macrocycle’s five stilbenes generating distorted isomers to turn off binding. With modest reversibility, only a single-shot release was demonstrated, akin to photodriven uncaging. These methods were extended to the capture and photodriven release of ReO$^{–}_{4}$ and radioactive 99 TcO$^{–}_{4}$ anions at ∼90% efficiency. Extraction was demonstrated down to the highly dilute 4 ppb levels of the 99 TcO$^{–}_{4}$ anion. Furthermore, this proof-of-concept demonstration verifies the use of a large change in affinity for the all-to-nothing capture and release of target anions between liquid phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

Synthetic Calcium Carbonate Production by Carbon Dioxide (CO 2 ) Mineralization of Industrial Waste Brines

The global scale of CO 2 emission has crossed 36 B tons, and the United State represents 14% of the total emissions. In light of the high cost associated with current CO 2 capture processes ($60-to-150 per ton of CO 2 ), carbon capture and utilization (CCU), wherein CO 2 is converted to beneficial products, provides a pragmatic path to overcome the economic barrier for CO 2 emissions control. In particular, CO 2 mineralization offers an attractive route as it produces high-value mineral carbonates that sequester CO 2 in a stable form. For instance, fine precipitated calcium carbonate, a valuable product with unit price in the range of $230-280/t and a global market projected to reach 99 M tons in 2020, can be produced by capturing CO 2 within aqueous Ca 2+ solution. However, two critical challenges need to be overcome—(i) the need for costly processes such as electrolysis or addition of alkali hydroxides to maintain alkalinity during mineralization, and (ii) the geographic availability of Ca-rich solutions (or brines) which often renders efficient integration with power plants impractical. To simultaneously address these challenges, this project developed two novel routes to enable carbonate production based on efficient CO 2 mineralization. In one variation, the project developed a new alkaline carbonation process to capture CO 2 and produce calcite precipitates from coal ashes. Herein, coal ash is carbonated first in a sodium carbonate solution. The carbonation reaction produces sodium hydroxide and raises the solution pH. This high-pH hydroxide solution is then used for CO 2 capture, which converts the sodium hydroxide solution back to sodium carbonate to repeat the carbonation cycle. The carbonated ash residue is refined with a CO 2 pressure swing step to produce high-purity precipitated calcium carbonate. In another variation, Ca-rich produced water brine serves as the Ca-source to mineralize CO 2 . An H + /Na + ion-exchange cycle was designed to provision alkalinity during mineralization and regenerate the ion-exchange reagent in brines with high salinity. Ca-depleted brines can then be treated within a centralized water treatment facility. Both variations beneficially utilize reject streams—such as coal ashes and brines from oil and gas extraction or CO 2 storage operations—that are available at substantial quantities in the vicinity of coal power plants within the U.S. In addition to technology development, this project included techno-economic and life-cycle analysis to identify technically and economically appropriate solutions for power plants in different geographic locations. Taken together, the project provides a unique route to integrate CO 2 emissions control and waste handling/treatment for coal power plants, while producing a high-value product to offset the economic burden associated with waste management. The developed processes utilize post-desulfurization flue gas from coal-fired power plants as is. The CO 2 conversion reactions are performed in alkaline brines at ambient pressure from the flue gas, thereby minimizing the energy burden. By beneficiation of industrial waste streams with low energy input, the processes offers significant technical advantages in energy and CO 2 footprint over the current paradigm of precipitated calcium carbonate production, which involves calcination of limestone at processing temperatures in excess of 800 °C. Overall, this project developed viable CO 2 mineralization processes while strategically maximizing the economic benefit.

01 COAL, LIGNITE, AND PEAT↗

Diffusion coefficients in the envelopes of white dwarfs

The diffusion of elements is a key process in understanding the unusual surface composition of white dwarfs and their spectral evolution. The diffusion coefficients of Paquette et al. have been widely used to model diffusion in white dwarfs. In this work, we perform new calculations of the coefficients of interdiffusion and ionic thermal diffusion with (1) a more advanced model that uses a recent modification of the calculation of the collision integrals that is more suitable for the partially ionized, partially degenerate, and moderately coupled plasma and (2) classical molecular dynamics. The coefficients are evaluated for silicon and calcium in white dwarf envelopes of hydrogen and helium. A comparison of our results with Paquette et al. shows that the latter systematically underestimates the coefficient of interdiffusion yet provides reliable estimates for the relatively weakly coupled plasmas found in nearly all types of stars, as well as in white dwarfs with hydrogen envelopes. In white dwarfs with cool helium envelopes (${T}_{\mathrm{eff}}$ < 15,000 K), the difference grows to more than a factor of two. We also explored the effect of the ionization model used to determine the charges of the ions and found that it can be a substantial source of discrepancy between different calculations. Finally, we consider the relative diffusion timescales of Si and Ca in the context of the pollution of white dwarf photospheres by accreted planetesimals and find factor of ≳3 differences between calculations based on Paquette et al. and our model.

79 ASTRONOMY AND ASTROPHYSICS↗

Photoionization mass spectrometer

Photoionization source with a vacuum UV monochromator is used in ion reaction kinetics. Monochromator passes only the photon energies near the threshold of the selected ionization process. Absence of electron impact alleviates creation of different type ions that result in ion fragmentation.

Warneck, P.↗

SERT D spacecraft study

The SERT D (Space Electric Rocket Test - D) study defines a possible spacecraft project that would demonstrate the use of electric ion thrusters for long-term (5 yr) station keeping and attitude control of a synchronous orbit satellite. Other mission objectives included in the study were: station walking to satellite rendezvous and inspection, use of low cost attitude sensing system, use of an advanced solar array orientation and slip ring system, and an ion thruster integrated directly with a solar array power source. The SERT D spacecraft, if launched, will become SERT 3 the third space electric thruster test.

Source record↗