Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Dark-field X-ray imaging of unsaturated water transport in porous materials

We introduce in this Letter an approach to X-ray imaging of unsaturated water transport in porous materials based upon the intrinsic X-ray scattering produced by the material microstructural heterogeneity at a length scale below the imaging system spatial resolution. The basic principle for image contrast creation consists in a reduction of such scattering by permeation of the porosity by water. The implementation of the approach is based upon X-ray dark-field imaging via Talbot-Lau interferometry. The proof-of-concept is provided by performing laboratory-scale dark-field X-ray radiography of mortar samples during a water capillary uptake experiment. The results suggest that the proposed approach to visualizing unsaturated water transport in porous materials is complementary to neutron and magnetic resonance imaging and alternative to standard X-ray imaging, the latter requiring the use of contrast agents because based upon X-ray attenuation only.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Mertens Unrolled Network (MU-Net): A High Dynamic Range Fusion Neural Network for Through the Windshield Driver Recognition

Face recognition of vehicle occupants through windshields in unconstrained environments poses a number of unique challenges ranging from glare, poor illumination, driver pose and motion blur. In this paper, we further develop the hardware and software components of a custom vehicle imaging system to better overcome these challenges. After the build out of a physical prototype system that performs High Dynamic Range (HDR) imaging, we collect a small dataset of through-windshield image captures of known drivers. We then reformulate the classical Mertens-Kautz-Van Reeth HDR fusion algorithm as a pre-initialized neural network, which we name the Mertens Unrolled Network (MU-Net), for the purpose of fine-tuning the HDR output of through-windshield images. Reconstructed faces from this novel HDR method are then evaluated and compared against other traditional and experimental HDR methods in a pre-trained state-of-the-art (SOTA) facial recognition pipeline, verifying the efficacy of our approach.

Ruby, Max↗

SU-E-P-10: Imaging in the Cardiac Catheterization Lab - Technologies and Clinical Applications

Purpose: Diagnosis and treatment of cardiovascular disease in the cardiac catheterization laboratory is often aided by a multitude of imaging technologies. The purpose of this work is to highlight the contributions to patient care offered by the various imaging systems used during cardiovascular interventional procedures. Methods: Imaging technologies used in the cardiac catheterization lab were characterized by their fundamental technology and by the clinical applications for which they are used. Whether the modality is external to the patient, intravascular, or intracavity was specified. Specific clinical procedures for which multiple modalities are routinely used will be highlighted. Results: X-ray imaging modalities include fluoroscopy/angiography and angiography CT. Ultrasound imaging is performed with external, trans-esophageal echocardiography (TEE), and intravascular (IVUS) transducers. Intravascular infrared optical coherence tomography (IVOCT) is used to assess vessel endothelium. Relatively large (>0.5 mm) anatomical structures are imaged with x-ray and ultrasound. IVUS and IVOCT provide high resolution images of vessel walls. Cardiac CT and MRI images are used to plan complex cardiovascular interventions. Advanced applications are used to spatially and temporally merge images from different technologies. Diagnosis and treatment of coronary artery disease frequently utilizes angiography and intra-vascular imaging, and treatment of complex structural heart conditions routinely includes use of multiple imaging modalities. Conclusion: There are several imaging modalities which are routinely used in the cardiac catheterization laboratory to diagnose and treat both coronary artery and structural heart disease. Multiple modalities are frequently used to enhance the quality and safety of procedures. The cardiac catheterization laboratory includes many opportunities for medical physicists to contribute substantially toward advancing patient care.

60 APPLIED LIFE SCIENCES↗

TU-CD-207-12: Impact of Anatomical Noise On Detection Performance of Microcalcifications in Multi-Contrast Breast Imaging

Purpose: The anatomical noise power spectra (NPS) for differential phase contrast (DPC) and dark field (DF) imaging have recently been characterized using a power-law model with two parameters, alpha and beta, an innovative extension to the methodology used in x-ray attenuation based breast imaging such as mammography, DBT, or cone-beam CT. Beta values of 3.6, 2.6, and 1.3 have been measured for absorption, DPC, and DF respectively for cadaver breasts imaged in the coronal plane; these dramatic differences should be reflected in their detection performance. The purpose of this study was to determine the impact of anatomical noise on breast calcification detection and compare the detection performance of the three contrast mechanisms of a multi-contrast x-ray imaging system. Methods: In our studies, a calcification image object was segmented out of the multi-contrast images of a cadaver breast specimen. 50 measured total NPS were measured from breast cadavers directly. The ideal model observer detectability was calculated for a range of doses (5–100%) and a range of calcification sizes (diameter = 0.25–2.5 mm). Results: Overall we found the highest average detectability corresponded to DPC imaging (7.4 for 1 mm calc.), with DF the next highest (3.8 for 1 mm calc.), and absorption the lowest (3.2 for 1 mm calc.). However, absorption imaging also showed the slowest dependence on dose of the three modalities due to the significant anatomical noise. DPC showed a peak detectability for calcifications ∼1.25 mm in diameter, DF showed a peak for calcifications around 0.75 mm in diameter, and absorption imaging had no such peak in the range explored. Conclusion: Understanding imaging performance for DPC and DF is critical to transition these modalities to the clinic. The results presented here offer new insight into how these modalities complement absorption imaging to maximize the likelihood of detecting early breast cancers. J. Garrett, Y. Ge, K. Li: Nothing to disclose. G.-H. Chen: Research funded, GE Healthcare; Research funded, Siemens AX.

60 APPLIED LIFE SCIENCES↗

SU-F-T-59: The Effect of Radiotherapy Dose On Immunoadjuvants

Purpose: Combining radiotherapy with immunotherapy is a promising approach to enhance treatment outcomes for cancer patients. This in-vitro study investigated which radiotherapy doses could adversely affect the function of anti-CD40 mAb, which is one of the key immunoadjuvants under investigations for priming such combination therapy. Methods: Human monocyte derived THP-1 cells were treated with 100ng/mL of PMA in chamber slides to differentiate into macrophage. The THP-1 differentiated macrophages were treated with 2uL/ml of the anti-CD40 mAb and incubated at 37°C and 5% CO2 for 24 hours. Anti-CD40 mAb treated cells were then irradiated at different doses of x-rays: (0, 2, 4, 6, 8, and 12) Gy using the Small Animal Radiotherapy Research Platform (SARRP). After radiation, the cells were left at 4°C for 2 hours followed by immunofluorescence assay. A Nikon inverted live-cell imaging system with fluorescence microscope was used to image the cells mounted on a slide fixed with Dapi. For comparison, an ELISA assay was performed with the antibody added to 3mL of PBS in multiple 10mm dishes. The 10mm dishes were irradiated at different x-ray dose: (0, 2, 4, 6, 8. 10, 12, and 15) Gy using the SARRP. Results: The anti-CD40 mAb activating the macrophages starts to lose their viability due to radiation dose between 8Gy to 12Gy as indicated by the immunofluorescence assay. The ELISA assay, also indicated that such high doses could lead to loss of the mAb’s viability. Conclusion: This work suggests that high doses like those employed during Stereotactic Ablative Radiotherapy may affect the viability of immunoadjuvants such as anti-CD 40. This study avails in-vivo experiments combining radiotherapy with anti-cd40 to get synergistic outcomes, including in the treatment of metastatic disease.

60 APPLIED LIFE SCIENCES↗

Principles and techniques of the quantum diamond microscope

We provide an overview of the experimental techniques, measurement modalities, and diverse applications of the quantum diamond microscope (QDM). The QDM employs a dense layer of fluorescent nitrogen-vacancy (NV) color centers near the surface of a transparent diamond chip on which a sample of interest is placed. NV electronic spins are coherently probed with microwaves and optically initialized and read out to provide spatially resolved maps of local magnetic fields. NV fluorescence is measured simultaneously across the diamond surface, resulting in a wide-field, two-dimensional magnetic field image with adjustable spatial pixel size set by the parameters of the imaging system. NV measurement protocols are tailored for imaging of broadband and narrowband fields, from DC to GHz frequencies. Here we summarize the physical principles common to diverse implementations of the QDM and review example applications of the technology in geoscience, biology, and materials science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Reference Hardware and Software Architecture for a Solenoid Pulser for Scientific Instrumentation at the National Ignition Facility

High current, high voltage solenoid pulser power systems for the generation of magnetic fields in a solenoid is not a radical or new concept. Despite being a cornerstone of scientific and weapons research for over 100 years, a commercial off the shelf unit easily configurable for a broad set of applications has yet to appear on the open market. Pulser systems are instead designed for specific target requirements. For gigawatt to terawatt systems, this is unavoidable. For megawatt systems however, many hundreds of thousands of dollars are wasted designing pulser systems from the ground up for clients, when it is possible to simply architect a modular system once that can have its capacitors swapped for many possible target applications. The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory (LLNL) is one such institution that would benefit from such a system, having bought such pulsers for several imaging systems. Ideally, all such a system would require is only a bachelors-level circuit analysis to find the correct capacitor values, as well as a written procedure to calibrate the software to correctly deliver the voltages required by the application. In this work, systems architecture and software engineering techniques are used to design and analyze such a system. Such a design, it is the hope of this author, will be used in scientific and engineering purposes in the future to build solenoid pulsers at the National Ignition Facility and other institutions to drastically cut development costs of scientific instrumentation.

42 ENGINEERING↗

Multispectral mapping of the lunar surface using ground-based telescopes

Images of the lunar surface were obtained at several wavelengths using a silicon vidicon imaging system and ground-based telescopes. These images were recorded and processed in digital form so that quantitative information was preserved. The photometric precision of the images is shown to be better than 1%. Ratio images calculated by dividing images obtained at two wavelengths (0.40/0.56 and 0.95/0.56 microns) are presented for about 50% of the lunar frontside. Spatial resolution is about 2 km at the subearth point. A complex of distinct units is evident in the images. Earlier work with the reflectance spectrum of lunar materials indicates that, for the most part, these units are compositionally distinct.

Mccord, T. B.↗

The low intensity X-ray imaging scope /Lixiscope/

A fully portable, small-format X-ray imaging system, Lixiscope (low intensity X-ray imaging scope) is described. In the prototype, which has been built to demonstrate the feasibility of the Lixiscope concept, only well-developed and available components have been used. Consideration is given to the principles of operation of the device, some of its performance characteristics as well as possible dental, medical and industrial applications.

Yin, L. I.↗

Lunar multispectral maps - Part II of the lunar nearside

Images of the lunar surface are being obtained at several wavelengths using a silicon vidicon imaging system and ground-based telescopes. These images are recorded and processed in digital form so that quantitative information is preserved; their photometric precision has been shown to be 1% or better. Ratio images, calculated by dividing those obtained at two wavelengths (0.40/0.56 and 0.95/0.56 micron), were presented in an earlier article, and more are presented here for a total coverage of about 60% of the lunar frontside. Spatial resolution is about 2 km at the subearth point. A complex of distinct units is evident in the images. Earlier work with the reflectance spectrum of lunar materials indicates that for the most part these units are compositionally distinct. These digital images are being used by lunar geologists to interpret the history of the lunar surface.

Mccord, T. B.↗

Lunar maria and related deposits: Preliminary Galileo imaging results

During the Earth-Moon flyby the Galileo Solid State Imaging system obtained new information on lunar media. Imaging data in spectral bands from 0.4 to 1.0 micron wavelength provide color data for deposits on the western limb. General objectives were to determine the composition and stratigraphy of mare and related deposits for areas not previously seen well in color, and to compare the results with well-studied nearside maria. Initial results from images reduced with preliminary calibrations show that Galileo spectral reflectance data are consistent with previous earthbased observations.

Greeley, R.↗

Dexterity enhancement in microsurgery using telemicro-robotics

The presentation will focus on finding the spectrum of dexterity performance while performing microsurgery in various specialties. It will be noted that individuals vary markedly in their performance in the position, velocity, stability, and force domains. There are surgeons who have a tremor who otherwise move very slowly and carefully while there are other surgeons who apply excessive force, but never have a tremor or move excessively fast. There are yet other surgeons who move excessively fast, yet they do not have a tremor. Dexterity enhancement includes position down scaling, tremor filtering, fatigue elimination, and other second-order issues such as confining the work space, velocities, accelerations, or forces. It will be described that the hand's position performance is degraded when it is asked to actuate the tools and that remote actuation alone increases the positioning capabilities. It will be noted that rotary and telescopic functions are far more difficult than writing or engraving-like motions. The safety issues concerning velocities and forces will be discussed and the need for impedance control pointed out. Simplistically, the devices should be made with variable compliance so that they can function rigidly as a robot would or compliantly as a human would, depending on the setting of this parameter. Tool interfaces will be discussed with an emphasis on the overall performance of the position, end effector, and tool as a unit. Space constraints, force, and velocity requirements will be discussed in this section as well. Referencing the coordinate system to pre- or inter-operative imaging systems will be discussed as well as an emphasis on the system architecture.

Charles, Steve↗

Accuracy of Pressure Sensitive Paint

Uncertainty in pressure sensitive paint (PSP) measurement is investigated from a standpoint of system modeling. A functional relation between the imaging system output and luminescent emission from PSP is obtained based on studies of radiative energy transports in PSP and photodetector response to luminescence. This relation provides insights into physical origins of various elemental error sources and allows estimate of the total PSP measurement uncertainty contributed by the elemental errors. The elemental errors and their sensitivity coefficients in the error propagation equation are evaluated. Useful formulas are given for the minimum pressure uncertainty that PSP can possibly achieve and the upper bounds of the elemental errors to meet required pressure accuracy. An instructive example of a Joukowsky airfoil in subsonic flows is given to illustrate uncertainty estimates in PSP measurements.

Liu, Tianshu↗

Microspheres in Plasma Display Panels

Filling small bubbles of molten glass with gases is just as difficult as it sounds, but the technical staff at NASA is not known to shy away from a difficult task. When Microsphere Systems, Inc. (MSI), of Ypsilanti, Michigan, and Imaging Systems Technology, Inc. (IST), of Toledo, Ohio, were trying to push the limits of plasma displays but were having difficulty with the designs, NASA s Glenn Garrett Morgan Commercialization Initiative (GMCI) assembled key personnel at Glenn Research Center and Ohio State University for a brainstorming session to come up with a solution for the companies. They needed a system that could produce hollow, glass micro-sized spheres (microspheres) that could be filled with a variety of gasses. But the extremely high temperature required to force the micro-sized glass bubbles to form at the tip of a metal nozzle resulted in severe discoloration of the microspheres. After countless experiments on various glass-metal combinations, they had turned to the GMCI for help. NASA experts in advanced metals, ceramics, and glass concluded that a new design approach was necessary. The team determined that what was needed was a phosphate glass composition that would remain transparent, and they went to work on a solution. Six weeks later, using the design tips from the NASA team, Tim Henderson, president of MSI, had designed a new system in which all surfaces in contact with the molten glass would be ceramic instead of metal. Meanwhile, IST was able to complete a Phase I Small Business Innovation Research (SBIR) grant supported by the National Science Foundation (NSF) and supply a potential customer with samples of the microspheres for evaluation as filler materials for high-performance insulations.

Source record↗

Prediction and Evaluation of the Image of the WFIRST Coronagraph Pupil at the Shaped-Pupil Mask

To create a high contrast field of view with a shaped pupil coronagraph (SPC), the telescope pupil is imaged onto the shaped pupil mask, the shaped pupil mask is designed and fabricated through a design optimization based on a given pupil wavefront, and deformable mirrors (DM) in the coronagraph are modulated according to a nonlinear optimization procedure. Both the mask design optimization and the DM optimization require accurate knowledge of the image of the pupil at the shaped pupil plane for the calculation of Jacobians, and the evaluation of alignment tolerances. The shaped pupil coronagraphs demonstrated in the high contrast imaging testbed (HCIT) at JPL has heretofore assumed perfect imaging of the pupil onto the shaped pupil mask. Similarly, the design and performance modeling of the WFIRST CGI instrument makes the same assumption. In this paper we estimate and compare the image of the pupil mask at the shaped pupil plane in the case of the coronagraph testbed, and the image of the telescope pupil at the shaped pupil plane for the WFIRST CGI instrument. The estimated pupil images include field curvature and aberrations resulting from the layout of the parabolic mirror imaging system, which is optimized for the source image, not the image of the pupil. We also show the results of direct measurement of the image of the pupil mask at the shaped pupil plane in the coronagraph testbed.

Crowther, Blake↗

Lens-free compound eye cameras based on angle-sensitive meta-surfaces

A lens-free ultrathin imaging sensor using a compound-eye vision modality can be formed by forming a metasurface on each pixel of an array of pixels in a solid state imaging sensor. The metasurface can be configured to form a diffraction grating that directs light incident on the metasurface at a predefined angle to excite surface plasmon polaritons into the solid state imaging sensor and light incident at any other angle is reflected or diffracted away from the metasurface. Each pixel of the imaging sensor can be configured using the metasurface to only receive light incident from a different portion of a field of view. A computational imaging system can be used to construct the image from the individual pixels.

Paiella, Roberto↗

X-ray Diffraction Crystal Calibration and Characterization

National Security Technologies’ X-ray Laboratory is comprised of a multi-anode Manson type source and a Henke type source that incorporates a dual goniometer and XYZ translation stage. The first goniometer is used to isolate a particular spectral band. The Manson operates up to 10 kV and the Henke up to 20 kV. The Henke rotation stages and translation stages are automated. Procedures have been developed to characterize and calibrate various NIF diagnostics and their components. The diagnostics include X-ray cameras, gated imagers, streak cameras, and other X-ray imaging systems. Components that have been analyzed include filters, filter arrays, grazing incidence mirrors, and various crystals, both flat and curved. Recent efforts on the Henke system are aimed at characterizing and calibrating imaging crystals and curved crystals used as the major component of an X-ray spectrometer. The presentation will concentrate on these results. The work has been done at energies ranging from 3 keV to 16 keV. The major goal was to evaluate the performance quality of the crystal for its intended application. For the imaging crystals we measured the laser beam reflection offset from the X-ray beam and the reflectivity curves. For the curved spectrometer crystal, which was a natural crystal, resolving power was critical. It was first necessary to find sources of crystals that had sufficiently narrow reflectivity curves. It was then necessary to determine which crystals retained their resolving power after being thinned and glued to a curved substrate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Get the Picture?

Positive Systems has worked in conjunction with Stennis Space Center to design the ADAR System 5500. This is a four-band airborne digital imaging system used to capture multispectral imagery similar to that available from satellite platforms such as Landsat, SPOT and the new generation of high resolution satellites. Positive Systems has provided remote sensing services for the development of digital aerial camera systems and software for commercial aerial imaging applications.

Source record↗