Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid solutions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Finite-amplitude steady waves in plane viscous shear flows

Computations of two-dimensional solutions of the Navier-Stokes equations are carried out for finite-amplitude waves on steady unidirectional flow. Several cases are considered. The numerical method employs pseudospectral techniques in the streamwise direction and finite differences on a stretched grid in the transverse direction, with matching to asymptotic solutions when unbounded. Earlier results for Poiseuille flow in a channel are re-obtained, except that attention is drawn to the dependence of the minimum Reynolds number on the physical constraint of constant flux or constant pressure gradient. Attempts to calculate waves in Couette flow by continuation in the velocity of a channel wall fail. The asymptotic suction boundary layer is shown to possess finite-amplitude waves at Reynolds numbers orders of magnitude less than the critical Reynolds number for linear instability. Waves in the Blasius boundary layer and unsteady Rayleigh profile are calculated by employing the artifice of adding a body force to cancel the spatial or temporal growth. The results are verified by comparison with perturbation analysis in the vicinity of the linear-instability critical Reynolds numbers.

Milinazzo, F. A.↗

Grid-Following Inverters and Synchronous Condensers: A Grid-Forming Pair?

As power systems across the globe continue to achieve higher instantaneous penetrations of power electronic converter-interfaced renewable sources, the stability of these power systems is challenged because of the removal of synchronous machines, from which stability is traditionally derived. Although technological solutions to these stability challenges are on the horizon, such as the use of grid-forming inverters, they are not yet widely applied to larger power systems, which presents operational challenges for power systems achieving these high instantaneous penetrations today. A potential interim solution using existing technologies is to pair synchronous condensers with grid-following inverters, which might prolong the stability of an operating power system while synchronous generators are turned off during periods of high renewable energy availability. This work examines the transient stability of such a solution using PSCAD simulations of a two-bus system coupled to a varied-length transmission line, with a synchronous condenser at one bus and a grid-following inverter with grid-support functionality at the other. The system is exposed to load step, balanced fault, and unbalanced fault perturbations. It was found that this simple system returned to a steady state for transmission line lengths up to 125 km after 10% load steps, or a variety of fault types.

grid-following inverters↗

On the Need for Communication for Voltage Regulation of Power Distribution Grids

We consider the problem of regulating the voltage profile of a power distribution grid by controlling the reactive power injection of distributed microgenerators. We define a very general class of purely local feedback controllers in which reactive power injection is adjusted based on the local voltage measurements. This class includes most of the solutions proposed in the literature and in the latest grid codes. We show that these strategies do not guarantee the desired regulation, as each of them can have an equilibrium that is not feasible with respect to the desired voltage and power constraints. We then propose a networked feedback law to show that, by adding short-range communication between microgenerators, it is possible to design control strategies that provably converge to the feasible set. This fundamental performance gap between local and networked strategies is finally illustrated via simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navier-Stokes calculations using Cartesian grids. I - Laminar flows

A finite-volume formulation for the Navier-Stokes equations using Cartesian grids is used to study flows past airfoils. In addition to the solution of the complete equations, solutions for two simplified versions of the governing equations were obtained and compared with those using body-fitted grids. Results are presented for two airfoil sections, NACA 0012 and RAE 2822, for a range of Mach numbers, angles of attack, and Reynolds numbers. It is shown that the results are highly dependent on the smoothness of the surface grid. Without such smoothness, the skin friction and pressure converge to nonuniform distributions. On the other hand, when surface cells with smoothly varying areas are used, the results compared favorably with calculations employing body-fitted grids.

Frymier, Paul D., Jr.↗

A hub and spoke approach to optimizing energy wheeling of renewable resources

The deployment of zero carbon renewable energy sources needs to increase significantly to support the goal of net zero greenhouse gas emissions by 2050. At the same time energy end use needs to decarbonize. This will change both energy supply and energy demand patterns, requiring the energy delivery infrastructure (grid-based transmission circuits) to become increasingly flexible to maintain security of supply everywhere and always. The integration of zero carbon renewable energy requires cross-border and cross energy system coupling and a fit-for-purpose design. Nowadays, energy systems are planned, designed and operated in silos with a strong national focus. However, large-scale offshore wind production needs to be transported to deep inland locations, across country borders. The increased peak generation capacity of renewable energy sources will, at times, significantly exceed demand (Matthew Langholtz, 2020). The traditional solution of continuously reinforcing and extending the electricity grid is not sustainable from a cost and societal perspective. This paper will, however, propose a deterministic approach on how networked (interconnected grid) Points of receipt (POR) to Points of Delivery (POD) can be optimized for wheeling renewable energy resources while minimizing energy cost with a hub and spoke approach. The statistical approach will be done via using existing daily energy market clearing prices, available transmission capacity and firm daily transmission prices in open access energy markets. Renewable energy targets, including specific offshore wind targets, need to be in line with the ramp-up as implied by the Paris Agreement. These targets are required to provide industry with a secure market outlook that allows them to build up supply chains accordingly. Optimizing wheeled energy paths from carbon neutral resources such as renewables make them not only cost competitive on the unit commitment stack, but also more accessible on the dispatch stack to other carbon heavy forms of generation such as coal and natural gas turbines (Matthew Langholtz, 2020). This correlates to maximizing renewable resource inertia (wind, solar, biomass) within an interconnected grid without having to consider additional expansion of resources via land purchases and de-forestation.

Mukherjee, Srijib↗

Evaluation of Counter-Based Dynamic Load Balancing Schemes for Massive Contingency Analysis on Over 10,000 Cores

Contingency analysis studies are necessary to assess the impact of possible power system component failures. The results of the contingency analysis are used to ensure the grid reliability, and in power market operation for the feasibility test of market solutions. Currently, these studies are performed in real time based on the current operating conditions of the grid with a set of pre-selected contingency list, which might result in overlooking some critical contingencies caused by variable system status. To have a complete picture of a power grid, more contingencies need to be studied to improve grid reliability. High-performance computing techniques hold the promise of being able to perform the analysis for more contingency cases within a much shorter time frame. This paper evaluates the performance of counter-based dynamic load balancing schemes for a massive contingency analysis program on 10,000+ cores. One million N-2 contingency analysis cases with a Western Electricity Coordinating Council power grid model have been used to demonstrate the performance. The speedup of 3964 with 4096 cores and 7877 with 10240 cores are obtained. This paper reports the performance of the load balancing scheme with a single counter and two counters, describes disk I/O issues, and discusses other potential techniques for further improving the performance.

Balancing Schemes for Massive Contingency↗

An efficient flexible-order model for 3D nonlinear water waves

The flexible-order, finite difference based fully nonlinear potential flow model described in [H.B. Bingham, H. Zhang, On the accuracy of finite difference solutions for nonlinear water waves, J. Eng. Math. 58 (2007) 211-228] is extended to three dimensions (3D). In order to obtain an optimal scaling of the solution effort multigrid is employed to precondition a GMRES iterative solution of the discretized Laplace problem. A robust multigrid method based on Gauss-Seidel smoothing is found to require special treatment of the boundary conditions along solid boundaries, and in particular on the sea bottom. A new discretization scheme using one layer of grid points outside the fluid domain is presented and shown to provide convergent solutions over the full physical and discrete parameter space of interest. Linear analysis of the fundamental properties of the scheme with respect to accuracy, robustness and energy conservation are presented together with demonstrations of grid independent iteration count and optimal scaling of the solution effort. Calculations are made for 3D nonlinear wave problems for steep nonlinear waves and a shoaling problem which show good agreement with experimental measurements and other calculations from the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cell volume control at a surface for three-dimensional grid generation packages

An alternate method of calculating the cell size for orthogonality control in the solution of Poisson's 3D space equations is presented. The method provides the capability to enforce a better initial guess for the grid distribution required for boundary layer resolution. This grid point distribution is accomplished by enforcing grid spacing from a grid block boundary where orthogonality is required. The actual grid spacing or cell size for that boundary is determined by the two or four adjacent boundaries in the grid block definition, which are two dimensional grids. These two dimensional grids are in turn defined by the user using insight into the flow field and boundary layer characteristics. The adjoining boundaries are extended using a multifunctional blending scheme, with user control of the blending and interpolating functions to be used. This grid generation procedure results in an enhanced computational fluid dynamics calculation by allowing a quicker resolution of the configuration's boundary layer and flow field and by limiting the number of grid re-adaptations. The cell size specification calculation was applied to a variety of configurations ranging from axisymmetric to complex three-dimensional configurations. Representative grids are shown for the Space Shuttle and the Langley Lifting Body (HL-20).

Alter, Stephen J.↗

On a Future for Smart Inverters with Integrated System Functions

The modern electric power grid is gradually evolving to include high penetration power electronics in a distributed architecture which will pose pressing new challenges on power quality, system control, and operation. The state-of-the-art smart inverters for solar photovoltaics may not be sufficient to address some of the stability and control challenges such as harmonic resonances due to the interactions of multiple power electronics converters. This paper discusses a future of smart inverters with integrated system functions and its associated challenges, and identifies smart inverter research trends and features in the context of flexible control architectures. Future power electronics research will shift from hardware solutions to more control solutions with integrated system functions under distributed power grid scenarios with small-scale power electronics interfaced with distributed generations and loads.

Xue, Yaosuo↗

National power grid simulation capability : need and issues

On December 9 and 10, 2008, the Department of Homeland Security (DHS) Science and Technology Directorate sponsored a national workshop at Argonne National Laboratory to explore the need for a comprehensive modeling and simulation capability for the national electric power grid system. The workshop brought together leading electric power grid experts from federal agencies, the national laboratories, and academia to discuss the current state of power grid science and engineering and to assess if important challenges are being met. The workshop helped delineate gaps between grid needs and current capabilities and identify issues that must be addressed if a solution is to be implemented. This report is a result of the workshop and highlights power grid modeling and simulation needs, the barriers that must be overcome to address them, and the benefits of a national power grid simulation capability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Survey of Composite Grid Generation for General Three-dimensional Sections

The generation and use of composite grids for general three-dimensional physical boundary configurations is discussed, and the availability of several codes or procedures is noted. With the composite framework, the physical region is segmented into sub-regions, each bounded by six curved sides, and a grid is generated in each sub-region. These grids may be joined at the interfaces between the sub-regions with various degrees of continuity. This structure allows codes to be constructed to operate on rectangular blocks in computational space, so that existing solution procedures can be readily incorporated in the construction of codes for general configurations. Numerical grid generation is an integral part of the numerical solution of partial differential equations and is one of the pacing items in the development of codes for general configurations. The numerically generated grid frees the computational simulation from restriction to certain boundary shapes and allows general codes to be written in which the boundary shape is specified simply by input. The numerically generated grid allows all computation to be done on a fixed square grid in the computational space, which is always rectangular by construction.

Thompson, J. F.↗

Energy storage planning for enhanced resilience of power systems against wildfires and heatwaves

Extreme weather events pose significant risks to power grid stability due to their severe consequences and potential for widespread failures. Energy storage systems hold great potential for enhancing grid resilience against such events by providing reliable power during peak demand periods. However, accurately quantifying the size, location, and investment costs of new energy storage assets is a complex task, as energy storage planning decisions depend on the investment choices of other generation technologies and the integration of new transmission projects. Here, this paper presents a novel capacity expansion planning framework that simultaneously optimizes investments in energy storage, generation, and transmission, determining their optimal size, location, and type, while incorporating extreme weather events into long-term planning. More specifically, our stress-event-informed planning framework integrates the impact of heatwaves and wildfires into the planning process, identifying least-cost investment solutions that comply with policy goals and enhance grid resilience. The proposed framework employs machine-learning-based modeling to project heatwave-induced loads and performance-based risk assessment to evaluate wildfire-driven transmission line derates. Using industry-standard datasets to accurately represent the transmission topology of the Western Interconnection (WI) system, the proposed framework is applied to the WI 40-zone system, with investment decisions reported for the years 2030, 2035, and 2040. Simulation results reveal that with just a 10% increase in investment costs, resilience against extreme events can be significantly improved, with investment decisions heavily favoring energy storage, particularly 4-hour energy storage systems.

25 ENERGY STORAGE↗

Oklahoma Wellbore Rasters

Seven raster surfaces generated from wellbore information that are thought to influence fluid and or gas migration in the subsurface. Wellbore information was originally retrieved from the IHS Energy Group (current as of April 2015), which is a proprietary, commercial database containing information for most oil and gas wells in the U.S. Processing of wellbore information into gridded cells was performed to provide a graphic solution to overcome the problem of displaying proprietary well data. No proprietary data are displayed or included in the cell maps. These rasters were developed to serve as inputs to the SIMPA (Spatially Weighted Multivariate Probabilistic Assessment) tool. Each raster surface is a derivative product of wellbore dataset. Each raster represents a single wellbore attribute or combination of attributes that speak to the following wellbore characteristics: number of recompletions, year spud, year abandoned, year completed, number of abandoned wells, hole direction, switch from production to injection. The original wellbore information, retrieved from the IHS Energy Group, are in the form of points – these derivative rasters aggregate point attributes to approximately 1,000-meter resolution grid cells. Each raster only includes cells that contain wellbores with the characteristics represented in each surface (i.e. if the wellbores in a given cell have no year abandoned data, the cell is not included in the raster). Since the raster cells combine data from multiple points in many cases, methods such as the average, minimum, and count are used to summarize the information in each cell. The specific operations used to develop each raster are detailed in its metadata.

Abandoned↗

A Data-Driven Algorithm for Enabling Delay Tolerance in Resilient Microgrid Controls Using Dynamic Mode Decomposition

The increased implementation of smart grid technologies in the power distribution grid presents unique opportunities that enable resiliency, but also brings challenges motivating needs for novel solutions and mitigation techniques. The bi-directional power and data flow allow for the grid to operate with increased resiliency, which is the ability to avoid discontinuity of service to end-use loads during extreme events. However, in applications where control of the distribution grid or microgrid relies on communication networks, the degradation of communication systems in the form of loss or high latency can cause maloperation and result in loss of end-use loads. Here this paper presents a novel framework to enable delay tolerance of centralized microgrid control schemes to mitigate communication system latency impacts and guarantee successful control action. We demonstrate the delay tolerance on a control scheme that operates a battery energy storage system (BESS) to offset the sudden loss of generation and maintain system frequency. During periods of severely degraded communication system performance, the proposed delay-tolerant algorithm compensates for the latency by utilizing a data-driven model generated at the device level using dynamic mode decomposition (DMD) to determine the performance of the communications. The DMD technique predicts the system’s frequency using device-level terminal measurements and provides updated control signals. The HELICS cosimulation platform evaluates the cyber-physical interaction of the power system model in GridLAB-D, the centralized control agent in Python, and the discrete network model in NS-3. The framework is tested and validated on the IEEE-123 node system modified to represent a networked remote microgrid model, and the results show an improvement in the dynamic performance

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of economically viable, highly integrated, highly modular SEGIS architecture

Initiated in 2008, the SEGIS initiative is a partnership involving the U.S. DOE, Sandia National Laboratories, private sector companies, electric utilities, and universities. Projects supported under the initiative have focused on the complete-system development of solar technologies, with the dual goal of expanding renewable PV applications and addressing new challenges of connecting large-scale solar installations in higher penetrations to the electric grid. Petra Solar, Inc., a New Jersey-based company, received SEGIS funds to develop solutions to two of these key challenges: integrating increasing quantities of solar resources into the grid without compromising (and likely improving) power quality and reliability, and moving the design from a concept of intelligent system controls to successful commercialization. The resulting state-of-the art technology now includes a distributed photovoltaic (PV) architecture comprising AC modules that not only feed directly into the electrical grid at distribution levels but are equipped with new functions that improve voltage stability and thus enhance overall grid stability. This integrated PV system technology, known as SunWave, has applications for 'Power on a Pole,' and comes with a suite of technical capabilities, including advanced inverter and system controls, micro-inverters (capable of operating at both the 120V and 240V levels), communication system, network management system, and semiconductor integration. Collectively, these components are poised to reduce total system cost, increase the system's overall value and help mitigate the challenges of solar intermittency. Designed to be strategically located near point of load, the new SunWave technology is suitable for integration directly into the electrical grid but is also suitable for emerging microgrid applications. SunWave was showcased as part of a SEGIS Demonstration Conference at Pepco Holdings, Inc., on September 29, 2011, and is presently undergoing further field testing as a prelude to improved and expanded commercialization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Grid Architecture Guidance Specification for FAST-DERMS (V.1.0)

This document provides grid architecture guidance to support the Grid Modernization Laboratory Consortium (GMLC) Federated Architecture for Secure and Transactive Distributed Energy Resource Management Solution (FAST-DERMS) project. The FAST-DERMS project seeks to develop an architecture and reference implementation solution that enables the provision of reliable, resilient, and secure transmission and distribution (T&D) grid services through the scalable aggregation and near-real-time management of utility-scale and small-scale distributed energy resources (DERs).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid generation and inviscid flow computation about aircraft geometries

Grid generation and Euler flow about fighter aircraft are described. A fighter aircraft geometry is specified by an area ruled fuselage with an internal duct, cranked delta wing or strake/wing combinations, canard and/or horizontal tail surfaces, and vertical tail surfaces. The initial step before grid generation and flow computation is the determination of a suitable grid topology. The external grid topology that has been applied is called a dual-block topology which is a patched C (exp 1) continuous multiple-block system where inner blocks cover the highly-swept part of a cranked wing or strake, rearward inner-part of the wing, and tail components. Outer-blocks cover the remainder of the fuselage, outer-part of the wing, canards and extend to the far field boundaries. The grid generation is based on transfinite interpolation with Lagrangian blending functions. This procedure has been applied to the Langley experimental fighter configuration and a modified F-18 configuration. Supersonic flow between Mach 1.3 and 2.5 and angles of attack between 0 degrees and 10 degrees have been computed with associated Euler solvers based on the finite-volume approach. When coupling geometric details such as boundary layer diverter regions, duct regions with inlets and outlets, or slots with the general external grid, imposing C (exp 1) continuity can be extremely tedious. The approach taken here is to patch blocks together at common interfaces where there is no grid continuity, but enforce conservation in the finite-volume solution. The key to this technique is how to obtain the information required for a conservative interface. The Ramshaw technique which automates the computation of proportional areas of two overlapping grids on a planar surface and is suitable for coding was used. Researchers generated internal duct grids for the Langley experimental fighter configuration independent of the external grid topology, with a conservative interface at the inlet and outlet.

Smith, Robert E.↗

Controllers for Distributed Grid Support for Power Systems using Hybrid DER plants with Electrolyzers [SWR-20-06]

This software presents the design and control for a hybrid DER site with integrated dispatchable electrolyzers. It is a comprehensive solution for regulating the dispatch of electrolyzer demand to support the grid using the respective control functions. Multiple control functions (ramp control, frequency support control, dispatch prioritization) are developed to integrate the proposed site for multiple services around load, voltage and frequency control. This allows the site owners to participate in both distribution and bulk system energy markets for grid ancillary services.

Jain, Rishabh↗