Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Modification to the NASA Langley 4- by 7-meter tunnel for improved rotorcraft aerodynamics and acoustics

Investigations have been conducted with the aim of improving circuit mean flow characteristics and test section turbulence intensity in the NASA Langley 4 x 7-m wind tunnel. Flow deflectors were instaled to displace the airstream and provide more symmetrical velocity distributions. The periodic flow pulsations of the open test section configuration were addressed by modifications of either the test section entrance, using triangular vanes, or the test section exit, using an alternative flow collector geometry; the latter proved more effective.

Applin, Z. T.↗

Heat Transfer Experiments of Ribbed, Serpentine Cooling Passages with Supercritical CO2

The results of heat transfer experiments with supercritical CO2 (sCO2) to capture the performance of ribbed, serpentine cooling passages for Reynolds numbers in the range of 100,000 - 400,000 are presented. The oxy-combustion turbine operating in an Allam-Fetvedt cycle has a turbine inlet temperature exceeding 1100°C, necessitating internally cooled turbine blades due to material creep strength limits. Reynolds numbers for sCO2, with its combination of high fluid density and low viscosity, can be up to an order of magnitude higher than comparable internal cooling conditions for an air-breathing engine where the majority of experimental data exists. To improve the prediction of cooling performance through turbulated passages, a test rig was designed and constructed with interchangeable insert capability for operation in sCO2 with heat transfer from a heater outlet flow stream to a lower temperature recuperator outlet flow stream. The inserts included serpentine passage geometry with five passes, one of the inserts including chevron ribs and the other a plain wall. The multi-pass serpentine geometry allowed for the evaluation of the effects 180 deg. tip turns have on the return passage flow characteristics, as they can depart significantly from fully-developed flow characteristics. The test procedure included the use of a modified Wilson plot method, with hot flow stream conditions kept effectively constant so that monitored changes in the overall thermal resistance could be attributed to manipulations in cooling flow stream conditions. Conditions during testing consisted of test section pressures of approximately 180 bar, cooling flow stream temperature of 175°C and hot flow stream temperature of 410°C. Test points at discrete cool flow Reynolds numbers up to 400,000 demonstrated an expected trend of decreased fluid thermal resistance with increasing Reynolds number, while at comparable Reynolds number there was an exhibited lower thermal resistance and higher passage pressure drop for the ribbed insert compared to the plain-walled insert. Processing of test data included establishment of Nusselt number enhancement ratios, so that for different internal cooling passage dimensions in the actual turbine blade at comparable Reynolds number the ratio could be applied to predict cooling performance.

Marshall, Michael↗

Structural tests and development of a laminar flow control wing surface composite chordwise joint

The dramatic increases in fuel costs and the potential for periods of limited fuel availability provided the impetus to explore technologies to reduce transport aircraft fuel consumption. NASA sponsored the Aircraft Energy Efficiency (ACEE) program beginning in 1976 to develop technologies to improve fuel efficiency. The Lockheed-Georgia Company accomplished under NAS1-16235 Laminar-Flow-Control (LFC) Wing Panel Structural Design and Development (WSSD); design, manufacturing, and testing activities. An in-depth preliminary design of the baseline 1993 LFC wing was accomplished. A surface panel using the Lockheed graphite/epoxy integrated LFC wing box structural concept was designed. The concept was shown by analysis to be structurally efficient and cost effective. Critical details of the surface and surface joint was demonstrated by fabricating and testing complex, concept selection specimens. The Lockheed-Georgia Company accomplishments, Development of LFC Wind Surface Composite Structures (WSCS), are documented. Tests were conducted on two CV2 panels to verify the static tension and fatigue strength of LFC wing surface chordwise joints.

Lineberger, L. B.↗

Validation of an Impedance Education Method in Flow

This paper reports results of a research effort to validate a method for educing the normal incidence impedance of a locally reacting liner, located in a grazing incidence, nonprogressive acoustic wave environment with flow. The results presented in this paper test the ability of the method to reproduce the measured normal incidence impedance of a solid steel plate and two soft test liners in a uniform flow. The test liners are known to be locally react- ing and exhibit no measurable amplitude-dependent impedance nonlinearities or flow effects. Baseline impedance spectra for these liners were therefore established from measurements in a conventional normal incidence impedance tube. A key feature of the method is the expansion of the unknown impedance function as a piecewise continuous polynomial with undetermined coefficients. Stewart's adaptation of the Davidon-Fletcher-Powell optimization algorithm is used to educe the normal incidence impedance at each Mach number by optimizing an objective function. The method is shown to reproduce the measured normal incidence impedance spectrum for each of the test liners, thus validating its usefulness for determining the normal incidence impedance of test liners for a broad range of source frequencies and flow Mach numbers. Nomenclature

Watson, Willie R.↗

Total-pressure-tube averaging in pulsating flows.

A number of total-pressure tubes were tested in a nonsteady flow generator in which the fraction of period that pressure is a maximum is approximately 0.8, thereby simulating turbomachine-type flow conditions. The tests were performed at a pressure level of 1 bar, for Mach numbers up to near 1, and frequencies up to 3 kHz. Most of the tubes indicated a pressure which was higher than the true average. Organ-pipe resonances which further increased the indicated pressure were encountered within the tubes at discrete frequencies. There was no obvious combination of tube diameter, length, and/or geometry variation used in the tests which resulted in negligible averaging error. A pneumatic-type probe was found to measure true average pressure, and is suggested as a comparison instrument to determine whether nonlinear averaging effects are serious in unknown pulsation profiles.

Krause, L. N.↗

Curved-flow, rolling-flow, and oscillatory pure-yawing wind-tunnel test methods for determination of dynamic stability derivatives

Dynamic stability derivatives are evaluated on the basis of rolling-flow, curved-flow and snaking tests. Attention is given to the hardware associated with curved-flow, rolling-flow and oscillatory pure-yawing wind-tunnel tests. It is found that the snaking technique, when combined with linear- and forced-oscillation methods, yields an important method for evaluating beta derivatives for current configurations at high angles of attack. Since the rolling flow model is fixed during testing, forced oscillations may be imparted to the model, permitting the measurement of damping and cross-derivatives. These results, when coupled with basic rolling-flow or rotary-balance data, yield a highly accurate mathematical model for studies of incipient spin and spin entry.

Chambers, J. R.↗

Acoustic tests of a 15.2 centimeter-diameter potential flow convergent nozzle

An experimental investigation of the jet noise radiated to the far field from a 15.2-cm-diam potential flow convergent nozzle has been conducted. Tests were made with unheated airflow over a range of subsonic nozzle exhaust velocities from 62 to 310m/sec. Mean and turbulent velocity measurements in the flow field of the nozzle exhaust indicated no apparent flow anomalies. Acoustic measurements yielded data uncontaminated by internal and/or background noise to velocities as low as 152m/sec. Finally, no significantly different acoustic characteristics between the potential flow nozzle and simple convergent nozzles were found.

Karchmer, A. M.↗

Test of Single-Stage Axial-Flow Fan

A single-stage axial fan was built and tested in the shop of the propeller-research tunnel of the NACA. The fan comprised a simple 24-blade rotor having a diameter of 21 inches and a solidity of 0.86 and a set of 37 contravanes having a solidity of 1.33. The rotor was driven by a 25-horsepower motor capable of rotating at a speed of 3600 r.p.m. The fan was tested for volume, pressure, and efficiency over a range of delivery pressures and volumes for a wide range of contravane and blade-angle settings. The test results are presented in chart form in terms of nondimensional units in order that similar fans may be accurately designed with a minimum effort. The maximum efficiency (88 percent) was obtained by the fan at a blade angle of 30 degrees and a contravane angle of 70 degrees. An efficiency of 80 percent was obtained by the fan with the contravanes removed.

Bell, E Barton↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Evidence of Technetium and Iodine from a Sodalite-Bearing Ceramic Waste Form

Current plans for nuclear waste vitrification at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) lack the capacity to treat all of the low activity waste (LAW) that is not encapsulated in the vitrified product. Several technologies are being considered to treat the excess LAW. One such technology is Fluidized Bed Steam Reforming (FBSR). The FBSR process results in a granular product composed of feldspathoid mineral phases that immobilize the major components in the LAW as well as other contaminants of concern (COCs), with Tc and I expected to be present in sodalite cages formed during the process. In order to meet compressive strength requirements at the Hanford Integrated Disposal Facility (IDF), the granular product may be encapsulated in a monolith. To demonstrate the ability of the technology to serve the mission of managing excess LAW, Single Pass Flow-Through (SPFT) tests have been performed on non-radioactive granular materials and granular materials encapsulated in a geopolymer binder produced at the engineering- and bench-scale as well as a granular product produced at the bench scale with actual Hanford tank waste. SPFT tests were conducted at 40 °C for durations up to 2 months with a flow-through solution buffered at pH 9. The forward reaction rate of the non-radioactive mineral product dissolution based on Si release for the granular product was measured to be (6.2 ± 2.1) × 10-4 g/m2d for the engineering-scale product and (13 ± 4.9) × 10-4 g/m2d for the bench-scale product. The resulting non-radioactive monoliths showed forward reaction rates based on Si release of (3.4 ± 1.1) × 10-4 g/m2d for the engineering-scale material and (4.2 ± 1.5) × 10-4 g/m2d for the bench-scale material demonstrating that encapsulation of the FBSR granular product in a monolith does not significantly alter the performance of the material. Finally, an FBSR granular product created at the bench scale using actual Hanford LAW gave similar release values and also demonstrated that Re and Tc show similar release behavior with a dilute-condition release rate of (1.1 ± 0.5) × 10-4 g/m2d for Tc and (1.6 ± 0.6) × 10-4 g/m2d for Re. We believe that this is the first demonstration to show that Re and I have similar release behavior and that similar behavior of Re and Tc also occurs. These results indicate that the FBSR mineral product may be a suitable supplementary immobilization technique at the Hanford site and they also suggest that both Tc and Re occupy similar sites in the sodalite cage structure.

fluidized bed steam reforming↗

Pressure distributions from subsonic tests of an advanced laminar-flow-control wing with leading- and trailing-edge flaps

An unswept, semispan wing model equipped with full-span leading- and trailing-edge flaps was tested in the Langley 14- by 22-Foot Subsonic Tunnel to determine the effect of high-lift components on the aerodynamics of an advanced laminar-flow-control (LFC) airfoil section. Chordwise pressure distributions near the midsemispan were measured for four configurations: cruise, trailing-edge flap only, and trailing-edge flap with a leading edge Kreuger flap of either 0.10 or 0.12 chord. Part 1 of this report presents a representative sample of the plotted pressure distribution data for each configuration tested. Part 2 (under separate cover) presents the entire set of plotted and tabulated pressure distribution data. The data are presented without analysis.

Applin, Zachary T.↗

Flow Disturbance Characterization Measurements in the National Transonic Facility

Recent flow measurements have been acquired in the National Transonic Facility (NTF) to assess the unsteady flow environment in the test section. The primary purpose of the test is to determine the feasibility of the NTF to conduct laminar-flow-control testing and boundary-layer transition sensitive testing. The NTF can operate in two modes, warm (air) and cold/cryogenic (nitrogen) test conditions for testing full and semispan scaled models. The warm-air mode enables low to moderately high Reynolds numbers through the use of high tunnel pressure, and the nitrogen mode enables high Reynolds numbers up to flight conditions, depending on aircraft type and size, utilizing high tunnel pressure and cryogenic temperatures. NASA's Environmentally Responsible Aviation (ERA) project is interested in demonstrating different laminar-flow technologies at flight-relevant operating conditions throughout the transonic Mach number range and the NTF is well suited for the initial ground-based demonstrations. Roll polar data at selected test conditions were obtained to look at the uniformity of the flow disturbance field in the test section. Data acquired from the rake probes included mean total temperatures, mean and fluctuating static/total pressures, and mean and fluctuating hot-wire measurements. . Based on the current measurements and previous data, an assessment was made that the NTF is a suitable facility for ground-based demonstrations of laminar-flow technologies at flight-relevant conditions in the cryogenic mode.

King, Rudolph A.↗

Pressure distributions from subsonic tests of an advanced laminar-flow-control wing with leading- and trailing-edge flaps

An unswept, semispan wing model equipped with full-span leading- and trailing-edge flaps was tested in the Langley 14- by 22-Foot Subsonic Tunnel to determine the effect of high-lift components on the aerodynamics of an advanced laminar-flow-control (LFC) airfoil section. Chordwise pressure distributions near the midsemispan were measured for four configurations: cruise, trailing-edge flap only, and trailing-edge flap with a leading-edge Krueger flap of either 0.10 or 0.12 chord. Part 1 of this report (under separate cover) presents a representative sample of the plotted pressure distribution data for each configuration tested. Part 2 presents the entire set of plotted and tabulated pressure distribution data. The data are presented without analysis.

Applin, Zachary T.↗

Analysis of screeching in a cold flow jet experiment

The screech phenomenon observed in a one-sixtieth scale model space shuttle test of the solid rocket booster exhaust flow noise has been investigated. A critical review is given of the cold flow test data representative of Space Shuttle launch configurations to define those parameters which contribute to screech generation. An acoustic feedback mechanism is found to be responsible for the generation of screech. A simple equation which permits prediction of screech frequency in terms of basic testing parameters such as the jet exhaust Mach number and the separating distance from nozzle exit to the surface of model launch pad is presented and is found in good agreement with the test data. Finally, techniques are recommended to eliminate or reduce the screech.

Wang, M. E.↗

Thermal performance evaluation of MSFC hot air collectors with various flow channel depth

The test procedures used and the results obtained during the evaluation test program on the MSFC air collector with flow channel depth of 3 in., 2 in., and 1 in., under simulated conditions are presented. The MSFC hot air collector consists of a single glass cover with a nonselective coating absorber plate and uses air as the heat transfer medium. The absorber panel consists of a thin flat sheet of aluminum.

Source record↗