Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “feedback control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

System Verification of MSL Skycrane Using an Integrated ADAMS Simulation

Mars Science Laboratory (MSL) will use the Skycrane architecture to execute final descent and landing maneuvers. The Skycrane phase uses closed-loop feedback control throughout the entire phase, starting with rover separation, through mobility deploy, and through touchdown, ending only when the bridles have completely slacked. The integrated ADAMS simulation described in this paper couples complex dynamical models created by the mechanical subsystem with actual GNC flight software algorithms that have been compiled and linked into ADAMS. These integrated simulations provide the project with the best means to verify key Skycrane requirements which have a tightly coupled GNC-Mechanical aspect to them. It also provides the best opportunity to validate the design of the algorithm that determines when to cut the bridles. The results of the simulations show the excellent performance of the Skycrane system.

White, Christopher↗

Carbon Nanofiber Nanoelectrodes for Neural Stimulation and Chemical Detection: The Era of Smart Deep Brain Stimulation

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

bioinstrumentation↗

Carbon Nanofiber Nanoelectrodes for Neural Stimulation and Chemical Detection: The Era of "Smart" Deep Brain Stimulation

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

human body↗

Carbon Nanofiber Electrode Array for Neurochemical Monitoring

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report using vertically aligned CNF as neurotransmitter recording electrodes for application in a smart deep brain stimulation (DBS) device. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Early Oscillation Detection for Hybrid DC/DC Converter Fault Diagnosis

This paper describes a novel fault detection technique for hybrid DC/DC converter oscillation diagnosis. The technique is based on principles of feedback control loop oscillation and RF signal modulations, and Is realized by using signal spectral analysis. Real-circuit simulation and analytical study reveal critical factors of the oscillation and indicate significant correlations between the spectral analysis method and the gain/phase margin method. A stability diagnosis index (SDI) is developed as a quantitative measure to accurately assign a degree of stability to the DC/DC converter. This technique Is capable of detecting oscillation at an early stage without interfering with DC/DC converter's normal operation and without limitations of probing to the converter.

Wang, Bright L.↗

Nanobiotechnology in Space Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable "smart" therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Koehne, Jessica E.↗

Carbon Nanomaterials for Biosensing Applications

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable “smart” therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

Carbon Nanomaterials for Biosensing Applications↗

How Do Climate Change Experiments Alter Plot-Scale Climate?

To understand and forecast biological responses to climate change, scientists frequently use field experiments that alter temperature and precipitation. Climate manipulations can manifest in complex ways, however, challenging interpretations of biological responses. We reviewed publications to compile a database of daily plot-scale climate data from 15 active-warming experiments. We find that the common practices of analysing treatments as mean or categorical changes (e.g. warmed vs.unwarmed) masks important variation in treatment effects over space and time. Our synthesis showed that measured mean warming, in plots with the same target warming within a study, differed by up to 1.6° Celsius degrees (63% of target), on average, across six studies with blocked designs. Variation was high across sites and designs: for example, plots differed by 1.1°Celsius degrees (47% of target) on average, for infrared studies with feedback control (n = 3) vs. by 2.2° Celsius degrees (80% of target) on average for infrared with constant wattage designs (n = 2). Warming treatments produce non-temperature effects as well, such as soil drying. The combination of these direct and indirect effects is complex and can have important biological consequences. With a case study of plant phenology across five experiments in our database, we show how accounting for drier soils with warming tripled the estimated sensitivity of budburst to temperature. We provide recommendations for future analyses, experimental design,and data sharing to improve our mechanistic understanding from climate change experiments, and thus their utility to accurately forecast species' responses.

warming experiment↗

Faraday Forcing of High-Temperature Levitated Liquid Metal Drops for the Measurement of Surface Tension

In this work, a method for the measurement of surface tension using continuous periodic forcing is presented. To reduce gravitational effects, samples are electrostatically levitated prior to forcing. The method, called Faraday forcing, is particularly well suited for fluids that require high temperature measurements such as liquid metals where conventional surface tension measurement methods are not possible. It offers distinct advantages over the conventional pulse-decay analysis method when the sample viscosity is high or the levitation feedback control system is noisy. In the current method, levitated drops are continuously translated about a mean position at a small, constant forcing amplitude over a range of frequencies. At a particular frequency in this range, the drop suddenly enters a state of resonance, which is confirmed by large executions of prolate/oblate deformations about the mean spherical shape. The arrival at this resonant condition is a signature that the parametric forcing frequency is equal to the drop’s natural frequency, the latter being a known function of surface tension. A description of the experimental procedure is presented. A proof of concept is given using pure Zr and a Ti(sub 39.5)Zr(sub 39.5)Ni(sub 21) alloy as examples. The results compare favorably with accepted literature values obtained using the pulse-decay method.

Nevin Brosius↗

Current Performance Characteristics of NASA Langley Research Center's Cockpit Motion Base and Standardized Test Procedure for Future Performance Characterization

This report documents the updated performance characteristics of NASA Langley Research Center's (LaRC) Cockpit Motion Base (CMB) after recent revisions that were made to its inner-loop, feedback control law. The modifications to the control law will be briefly described. The performance of the CMF will be presented. A short graphical comparison to the previous control law can be found in the appendix of this report. The revised controller will be shown to yield reduced parasitic accelerations with respect to the previous controller. Metrics based on the AGARD Advisory Report No. 144 are used to assess the overall system performance due to its recent control algorithm modification. This report also documents the standardized simulator test procedure which can be used in the future to evaluate potential updates to the control law.

Cowen, Brandon↗

Carbon Nanofiber Nanoelectrode Arrays for Neural Implant Devices

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. Here, we report two studies using vertically aligned CNF nanoelectrodes for biomedical applications. CNF arrays are investigated as neural stimulation and neurotransmitter recording electrodes for application in deep brain stimulation (DBS). Polypyrrole coated CNF nanoelectrodes have shown great promise as stimulating electrodes due to their large surface area, low impedance, biocompatibility and capacity for highly localized stimulation. CNFs embedded in SiO2 have been used as sensing electrodes for neurotransmitter detection. Our approach combines a multiplexed CNF electrode chip, developed at NASA Ames Research Center, with the Wireless Instantaneous Neurotransmitter Concentration Sensor (WINCS) system, developed at the Mayo Clinic. Preliminary results indicate that the CNF nanoelectrode arrays are easily integrated with WINCS for neurotransmitter detection in a multiplexed array format. In the future, combining CNF based stimulating and recording electrodes with WINCS may lay the foundation for an implantable smart therapeutic system that utilizes neurochemical feedback control while likely resulting in increased DBS application in various neuropsychiatric disorders. In total, our goal is to take advantage of the nanostructure of CNF arrays for biosensing studies requiring ultrahigh sensitivity, high-degree of miniaturization, and selective biofunctionalization.

carbon nanotubes↗

TPSAS-NF1676L-13606-DND

For over two decades, researchers at NASA Langley Research Center have been combining principles of engineering and psychology to explore the cognitive experiences of system operators. Conceptualizing the application of this interdisciplinary combination in the context of operators? extracurricular activities has resulted in the creation of numerous mental training spin-off technologies. Methods derived from feedback control concepts have been employed to assess the brains responses when managing automation and principles of conditioning have been embodied in devices designed to reinforce effective modes of psychophysiological activity. These methods and devices will be discussed and how they are being applied to ameliorate attention and stress disorders in clinical practice and impediments to optimal performance in sports will be demonstrated.

Alan T Pope↗

Reduced-Order Aerodynamic Modeling Based on CFD Frequency Responses from Multisine Inputs

A system identification analysis was performed to determine a reduced-order model (ROM) of a computational fluid dynamics (CFD) solver in support of linear aeroservoelastic model development and feedback control design. The approach was applied to the FUN3D code for the half-span wind tunnel test article used in the NASA-Boeing collaboration called the Integrated Adaptive Wing Technology Maturation (IAWTM) project. In a transonic flow condition, multiple inputs (11 structural mode displacements and 3 control surface deflections) were simultaneously excited with orthogonal phase-optimized multisines while multiple outputs (the corresponding 14 generalized aerodynamic forces) were recorded. From these recorded times series, the matrix of frequency responses was computed and subsequently fit using rational function approximations (RFAs). It was found that the entire (14 x 14) matrix of frequency responses could be determined from a single CFD run and that results generally followed trends predicted using other methods. Differences were attributed to the modeling fidelity and nonlinearities from structural mode and control surface interactions at higher reduced frequencies. More accurate fits of the RFAs to the frequency response data were obtained by making two CFD runs, one with only structural mode excitations and one with only control surface excitations, which reduced the degree of nonlinearity in the modeling data.

Aeroservoelasticity↗

Large-scale Additive Manufacturing for Exploration

Additive Manufacturing (AM) is emerging as a mainstream manufacturing technology, and demand for large part manufacturing is getting stronger. Direct Metal Deposition (DMD) is a DED technology based on laser and powder metal application using a closed-loop-feedback control system. This webinar focuses on additive manufacturing of NASA’s RS-25 engine nozzle liner using DMD technology. This liner (10ft in height and 8ft in diameter) is beyond the print capability of existing 3D printing processes. To print this part, significant advancements were made to the DMD technology by deploying two process heads in the machine and expanding the machine work envelop to allow manufacturing of such large parts in a safe and efficient environment. A successful demonstration of the AM of the RS25 engine nozzle liner marks a new era in 3D printing and elevates the current 3D printing technology to a new level for affordable manufacturing of large metal parts.

Additive Manufacturing↗

Detection and Mitigation of Transient Instabilities in Multi-Agent Systems and Swarms

We first introduce the novel concept of transient instabilities in multi-agent systems and swarms, i.e., a small disturbance leads to increasing-amplitude oscillations throughout the swarm, which results in a large number of inter-agent collisions. This instability is dominant in the transient phase of the system and it does not appear in the steady-state behavior of the system, as each agent uses Lyapunov-stable feedback control laws. We present a rigorous definition of transient instability in swarms, and discuss its key properties. We also present a sufficient condition to check if a swarm will be transient stable. We study the behaviour of different control laws under this condition. We also show how transient instability phenomenon could impact the dynamics of deployable structures. Next, we present a novel control architecture that augments the baseline formation maintenance controller to mitigate transient instabilities. At its heart, the proposed architecture consists of a projection operator based estimator disguised as a reference model that generates collision-free trajectories for the agents to follow. We present numerical simulation results to demonstrate the effectiveness of our proposed approaches.

Quadrelli, Marco B.↗

Recent System Identification Research at NASA Langley Research Center

This talk summarizes some of the recent advances in system identification at NASA Langley Research Center. Efforts discussed were applied to aeroelastic models, aircraft with redundant inputs and feedback control active, and aircraft flying in turbulence. Topics mentioned include experiment design with orthogonal multisine inputs, frequency response estimation, maximum likelihood parameter estimation, and parameter estimation considering process noise.

NASA LaRC↗

Parametric Mechanism Design Through Numerical Optimization and Physics Simulation

Design-Build-Test approaches for developing spaceflight hardware are prohibitively time and cost intensive and often lead to suboptimal mechanism designs. Approaches that couple machine learning and high-fidelity physics simulation could eliminate the need for hardware prototyping and dramatically accelerate the engineering design cycle, ultimately reducing cost. This work presents a modular NASA-developed toolchain to optimize hardware mechanisms in a virtual environment using numerical optimization and multi-body physics simulation. The toolchain enables multi-objective optimization, generates parametric CAD files that can be further post-processed by an end user, and can be expanded to optimize full systems and non-mechanical parameters such as feedback control variables. We demonstrate the toolchain through an independently verifiable design problem that optimizes wheel radius to achieve a desired linear velocity in a rigid-body physics environment when the wheel rotates at a constant angular speed, and then post-process the parametric CAD file of the optimal design generated by the tool before ultimately manufacturing it via 3D printing. We end with a discussion of how the toolchain can incorporate other analysis tools, including finite element analysis, computational fluid dynamics, and granular media simulations.

Optimization↗

An Optimization-Based Toolchain for Parametric Mechanism Design

Design-Build-Test approaches for developing spaceflight hardware are prohibitively time and cost intensive and often lead to suboptimal mechanism designs. Approaches that couple machine learning and high-fidelity physics simulation could eliminate the need for hardware prototyping and dramatically accelerate the engineering design cycle, ultimately reducing cost. This work presents a modular NASA-developed toolchain to optimize hardware mechanisms in a virtual environment using numerical optimization and multi-body physics simulation. The toolchain enables multi-objective optimization, generates parametric CAD files that can be further post-processed by an end user, and can be expanded to optimize full systems and non-mechanical parameters such as feedback control variables. We demonstrate the toolchain through an independently verifiable design problem that optimizes wheel radius to achieve a desired linear velocity in a rigid-body physics environment when the wheel rotates at a constant angular speed, and then post-process the parametric CAD file of the optimal design generated by the tool before ultimately manufacturing it via 3D printing. We end with a discussion of how the toolchain can incorporate other analysis tools, including finite element analysis, computational fluid dynamics, and granular media simulations.

Optimization↗