Silver clusters tune up electronic properties of graphene nanoflakes: A comprehensive theoretical study

Graphene-silver composites reflect a synergic effect of both components with enhanced electronic, adsorption and catalytic properties. We introduce here the detailed theoretical study on geometric, thermodynamic and electronic properties of silver clusters Ag n (n=2–10) adsorbed on graphene nanoflakes as a model for silver-graphene composites. First, a benchmark study is performed on Ag n …coronene complexes (n=2, 4) by evaluating various functional against reported high level ab-initio method for the selection of best functional for further calculations. Then, density functional theory study at the best chosen level is performed to inquire how clustering of adsorbate attached with carbon surface can impact geometric, electronic and thermodynamic properties of silver-graphene composites. Furthermore, the interaction energies are corrected for dispersion and basis set superposition error in order to get more realistic estimate of interaction energies. In progression, we investigated the dependence of interaction energy upon cluster size and dimensionality. For Ag n …coronene, the binding energies increase monotonically as the number of atoms in the cluster increases. However, for Ag n …dodecabenzocoronene, the interaction energies show a sudden drop at Ag 7 …dodecabenzocoronene. The difference in behavior between Ag n …dodecabenzocoronene and Ag n …coronene for interaction energy is attributed to edge effect present in coronene. Furthermore, coplanar orientations of the silver clusters on polyaromatic hydrocarbons have higher interaction energies. The 2D-3D transition of the silver cluster is observed for Ag 7 …coronene. CDA analysis reveals that backdonation from dodecabenzocoronene to silver clusters is more dominant in Ag 4 –Ag 7 whereas other clusters have dominant charge transfer to dodecabenzocoronene. Charge transfer analysis via constrained density functional theory (CDFT) reveals significant energy lowering from charge donor-acceptor interactions. Further energy decomposition analysis (EDA) using absolutely-localized molecular orbitals (ALMO) suggests that, while charge-transfer is important in these systems, the sum of electrostatics, Pauli repulsion, and London dispersion are far more significant as silver cluster size increases. NCI results also support the presence of van der Waals and electrostatic interactions. The hollow top is most favorite interaction sites compared to bridge top and head top binding sites over coronene lattice. The ionization potential, electron affinity, frontier molecular orbital analysis, chemical hardness, softness, chemical potential, and Fermi levels are deliberated to verify the stability and reactivity of most stable silver-graphene composites. The remarkable outcome of the current findings makes our silver-graphene composite as a potential applicant for high performance electronic and catalytic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Moving Embedded Boundary Approach for the Compressible Navier-Stokes Equations in a Block-Structured Adaptive Refinement Framework

A computational technique has been developed to perform compressible flow simulations involving moving boundaries using an embedded boundary approach within the block-structured adaptive mesh refinement (SAMR) framework of AMReX [1], [91], [92]. We leverage the SAMR capability to obtain quantitatively accurate results whilst using robust, second-order finite volume schemes. A conservative, unsplit, cut-cell approach is utilized and a ghost-cell approach is developed for computing the flux on the moving, embedded boundary faces. A third-order least-squares formulation has been developed to compute the wall velocity gradients, and was found to significantly improve the performance of the solver in terms of the quantitative comparison of surface quantities such as the skin friction coefficient. Various test cases are performed to validate the method, and compared with analytical, experimental, and other numerical results in literature. Inviscid and viscous test cases are performed that span a wide regime of flow speeds - acoustic (harmonically pulsating sphere), smooth flows (expansion fan created by a receding piston) and flows with shocks (shock-cylinder interaction, shock-wedge interaction, pitching NACA 0012 airfoil and shock-cone interaction). A closed system with moving boundaries - an oscillating piston in a cylinder, showed that the percentage error in mass within the system decreases with refinement, demonstrating that the numerical scheme is conservative with grid refinement, but is not discretely conservative. Viscous test cases involve that of a horizontally moving cylinder at Re = 40, an inline oscillating cylinder at Re = 100, and a transversely oscillating cylinder at Re = 185. The judicious use of adaptive mesh refinement with appropriate refinement criteria to capture the regions of interest leads to well-resolved flow features, and good quantitative comparison is observed with the results available in literature.

adaptive refinement↗

Flow condensation heat transfer performance of natural and emerging synthetic refrigerants

There is great interest in predicting flow condensation heat transfer for lower global warming potential (GWP) fluids. This paper analyzes the efficacy of common flow condensation correlations developed for particular fluids in order to identify their suitability to predict heat transfer performance of low GWP fluids. Condensation heat transfer data were extracted from the literature, including 19 papers and 1,473 data points for natural refrigerants [i.e., ammonia (R717), CO 2 (R744), propane (R290), isobutane (R600a)] and 35 papers and 5,030 data points for synthetic refrigerants [i.e., R12, R1234yf, R1234ze(E), R1234ze(Z), R22, R32, R41, R123, R125, R134a, R142b, R152a, R161, R404A, R410A, R448A, R449A, R450A, R452B, R454C, R455A, R513A] encompassing tube diameters of 0.1–11.5 mm, mass fluxes of 55–1200 kg/m2s, and saturation temperatures of -25°C–65°C. Correlations analyzed included Akers et al. (1959), Cavallini et al. (2006, 2011), Kim and Mudawar (2013), Macdonald and Garimella (2016), Shah (1979, 2009, 2013, 2016) and Traviss et al. (1973) for smooth tubes and Chamra et al. (2005) and Kedzierski and Goncalves (1999) for enhanced tubes. Since most studies did not report wall temperature, correlations which relied on wall temperature directly or indirectly were excluded from the analysis. For synthetic refrigerants, mean average error (MAE) ranged from 6%–257%, and Cavallini et al. (2011) and Kim and Mudawar (2013) were the best predictors for emerging synthetic refrigerants. Furthermore, the Kim and Mudawar (2013) correlation was found to best predict the heat transfer performance for propane and R600a data, but most correlations did not accurately predict ammonia and CO 2 flow condensation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

More buck-per-shot: Why learning trumps mitigation in noisy quantum sensing

Quantum sensing is one of the most promising applications for quantum technologies. However, reaching the ultimate sensitivities enabled by the laws of quantum mechanics can be a challenging task in realistic scenarios where noise is present. While several strategies have been proposed to deal with the detrimental effects of noise, these come at the cost of an extra shot budget. Given that shots are a precious resource for sensing – as infinite measurements could lead to infinite precision – care must be taken to truly guarantee that any shot not being used for sensing is actually leading to some metrological improvement. In this work, we study whether investing shots in error-mitigation, inference techniques, or combinations thereof, can improve the sensitivity of a noisy quantum sensor on a (shot) budget. We present a detailed bias–variance error analysis for various sensing protocols. Our results show that the costs of zero-noise extrapolation techniques outweigh their benefits. We also find that pre-characterizing a quantum sensor via inference techniques leads to the best performance, under the assumption that the sensor is sufficiently stable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

$\mathrm{PPT}$-Multicore: performance prediction of Open$\mathrm{MP}$ applications using reuse profiles and analytical modeling

In this report we present PPT-Multicore, an analytical model embedded in the Performance Prediction Toolkit (PPT) to predict parallel applications’ performance running on a multicore processor. PPT-Multicore builds upon our previous work towards a multicore cache model. We extract LLVM basic block labeled memory trace using an architecture-independent LLVM-based instrumentation tool only once in an application’s lifetime. The model uses the memory trace and other parameters from an instrumented sequentially executed binary. We use probabilistic and computationally efficient reuse profiles to predict the cache hit rates and runtimes of OpenMP programs’ parallel sections. We model Intel’s Broadwell, Haswell, and AMD’s Zen2 architectures and validate our framework using different applications from PolyBench and PARSEC benchmark suites. The results show that PPT-Multicore can predict cache hit rates with an overall average error rate of 1.23% while predicting the runtime with an error rate of 9.08%.

97 MATHEMATICS AND COMPUTING↗

Validation of URANS and STRUCT-ε turbulence models for stratified sodium flow

Simulations of a transient stratified sodium experiment are carried out using a classic unsteady RANS model and the second-generation URANS model, STRUCT-ε. Turbulence modeling challenges and their implications to stratified flow prediction are discussed in the context of other sources of error. Input errors are discussed and addressed; discretization error is calculated to be less than 5% of the inlet velocity, for 80% of the domain; and remaining errors in temperature distributions are attributed to the turbulence model. Qualitative flow features from the simulations are presented and discussed. Compared to the experiment, the STRUCT-ε turbulence model provides a more physically accurate prediction of temperature and momentum mixing in key regions of the domain. Quantitative measures such as the L 2 norm of the temperature discrepancy demonstrate the improved performance of the STRUCT-ε approach. In conclusion, the magnitude of the temperature fluctuations is very well-predicted by the STRUCT-ε, while URANS overpredicts them by approximately 50%.

42 ENGINEERING↗

Design Optimization and Measurement Uncertainty of an Electromagnetic Level Sensor for Liquid Metal Reactors

Here, this article describes the design and operation of a prototype mutual inductance level sensor (MILS) and the development and validation of a finite-element analysis (FEA) model describing its behavior. The MILS was designed for use in liquid sodium up to temperatures of 650 °C in the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL). Preliminary testing was performed in a room temperature test stand with aluminum acting as an analog for the sodium to better understand sensor performance and provide accurate code validation data. This experimental data, along with material properties found in literature, were used to validate an FEA model in ANSYS Maxwell. The validated ANSYS Maxwell model was used to examine the performance of the MILS in various environments and under various operating conditions. Simulations suggest the following: The MILS will perform adequately in liquid sodium and liquid lead at temperatures up to 650 °C . The temperature dependence of electrical conductivity imposes a temperature dependence on the sensor that requires proper compensation. The MILS signal sensitivity is maximized when mutual inductance between sensor coils is maximized, and sensor geometry should be selected to account for this factor. The operating frequency of the MILS can be optimized and is dependent on process fluid material, operating temperature, and materials/geometry of sensor system. Finally, the use of a stainless-steel isolating thimble does not adversely affect the sensor signal. The primary sources of error for this MILS system are the accuracy of the calibration standard against which the sensor is calibrated, and the temperature dependence of the sensor. This work contains all the necessary details to recreate the FEA model and results. This model can be used to optimize the performance of a MILS in any operating environment to read any electrically conductive working fluid.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Model uncertainty in accelerator application simulations

Monte-Carlo nuclear reaction and transport codes are widely used to devise accelerator-based nuclear physics experiments; at the same time, many experiments are performed to validate the Monte-Carlo codes, which can be used for the design of full-scale nuclear power applications or the design of new benchmark experiments. Dedicated model benchmark studies investigate a broad range of nuclear reactions and quantities. Examples of these include isotope formation or secondary particle fluxes that result from the interactions of GeV-range hadrons with monoisotopic targets, which can be used to assess the respective systematic uncertainty of models. Such benchmark studies, as well as many nuclear application experiments and simulations carried out by various groups over the last few decades, enable us to draw methodological lessons. In this work, model uncertainty determined based on available experimental data allow us to identify the effects of practitioner expertise as well as the design of codes (user access to micro-scale parameters) on the range of uncertainties. We found that in cases when simulations are performed by code developers or users that are very experienced in performing simulations, the model to experiment quantity ratios generally agree with the limits determined by dedicated benchmark studies. In other cases, the ratios generally tend to be either smaller (underestimation of model error) or larger (overestimation of model error). A plausible explanation of the aforementioned effects is suggested.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Autonomous stabilization with programmable stabilized state

Reservoir engineering is a powerful technique to autonomously stabilize a quantum state. Traditional schemes involving multi-body states typically function for discrete entangled states. In this work, we enhance the stabilization capability to a continuous manifold of states with programmable stabilized state selection using multiple continuous tuning parameters. We experimentally achieve 84.6% and 82.5% stabilization fidelity for the odd and even-parity Bell states as two special points in the manifold. We also perform fast dissipative switching between these opposite parity states within 1.8 μs and 0.9 μs by sequentially applying different stabilization drives. Our result is a precursor for new reservoir engineering-based error correction schemes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum approximate optimization of the long-range Ising model with a trapped-ion quantum simulator

Quantum computers and simulators may offer significant advantages over their classical counterparts, providing insights into quantum many-body systems and possibly improving performance for solving exponentially hard problems, such as optimization and satisfiability. Here, we report the implementation of a low-depth Quantum Approximate Optimization Algorithm (QAOA) using an analog quantum simulator. We estimate the ground-state energy of the Transverse Field Ising Model with long-range interactions with tunable range, and we optimize the corresponding combinatorial classical problem by sampling the QAOA output with high-fidelity, single-shot, individual qubit measurements. We execute the algorithm with both an exhaustive search and closed-loop optimization of the variational parameters, approximating the ground-state energy with up to 40 trapped-ion qubits. We benchmark the experiment with bootstrapping heuristic methods scaling polynomially with the system size. We observe, in agreement with numerics, that the QAOA performance does not degrade significantly as we scale up the system size and that the runtime is approximately independent from the number of qubits. We finally give a comprehensive analysis of the errors occurring in our system, a crucial step in the path forward toward the application of the QAOA to more general problem instances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demonstration of reconstruction-free static magnetic control of DIII-D plasma with deep reinforcement learning

This paper presents the development and experimental validation of a reinforcement learning (RL)-based magnetic controller on the DIII-D tokamak. The controller directly maps raw magnetic diagnostic signals to actuator commands, replacing the traditional isoflux control algorithm based on equilibrium reconstruction. Four RL controllers are trained using the Soft Actor–Critic algorithm with an asymmetric Actor–Critic architecture in the NSFsim simulator. All controllers are deployed in the DIII-D Plasma Control System and operated with a 4 kHz feedback loop. Two randomization strategies are evaluated during training: evolving kinetic profiles and fixed kinetic profiles within each episode. The latter approach is found to better capture experimental deviations in the current density profile and to provide overall improved control performance. Robust operation is demonstrated across heating power scans in both L- and H-mode plasmas, as well as during transient events such as L–H transitions and pellet injections. Control errors in plasma shape and radial position remained within 1.5–2.0 cm and 1 cm, respectively. A notable discrepancy was observed in the vertical X-point position, with errors of up to approximately 4 cm, attributed to the current density distribution mismatches between simulations and experiments.

DIII-D↗

Speeding up particle track reconstruction using a parallel Kalman filter algorithm

One of the most computationally difficult problems expected for the High-Luminosity Large Hadron Collider (HL-LHC) is determining the trajectory of charged particles during event reconstruction. Algorithms used at the LHC today rely on Kalman filtering, which builds physical trajectories incrementally while incorporating material effects and error estimation. Recognizing the need for faster computational throughput, we have adapted Kalman-filter-based methods for highly parallel, many-core SIMD architectures that are now prevalent in high-performance hardware. In this paper, we discuss the design and performance of the improved tracking algorithm, referred to as mkFit. A key piece of the algorithm is the Matriplex library, containing dedicated code to optimally vectorize operations on small matrices. The physics performance of the mkFit algorithm is comparable to the nominal CMS tracking algorithm when reconstructing tracks from simulated proton-proton collisions within the CMS detector. We study the scaling of the algorithm as a function of the parallel resources utilized and find large speedups both from vectorization and multi-threading. mkFit achieves a speedup of a factor of 6 compared to the nominal algorithm when run in a single-threaded application within the CMS software framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CUDO: closed-form universal dwell-time optimization for computer-controlled optical surfacing

Precision optical figuring demands fast and accurate dwell time optimization to reach nanometer- and sub-nanometer-level accuracy in next-generation optical systems. We introduce CUDO (closed-form universal dwell-time optimization), the first, to the best of our knowledge, unified closed-form analytical framework that supports both function-form and matrix-form dwell time models in computer-controlled optical surfacing (CCOS). In contrast to traditional methods, which rely on iterative optimization and hyperparameter tuning, our framework derives direct analytical solutions with no adjustable parameters. This approach unifies the solution principles of existing methods within a single mathematical model, delivering three key advantages: (1) accuracy on par with, or superior to, iterative solvers, (2) substantial reduction in computation time, and (3) numerical robustness. Comparative studies with prior art confirm that closed-form solutions achieve equivalent residual error while removing runtime bottlenecks. By simplifying the implementation and enabling real-time, scalable deployment, CUDO establishes a practical foundation for future deterministic fabrication of large-aperture and high-performance optics.

36 MATERIALS SCIENCE↗

Solute chemistry for streams draining geomorphic features and varying land cover gradients in the East River watershed, Colorado

This dataset contains solute chemistry data and GPS coordinates for surface water samples collected in the East River watershed in the Elk and West Elk Ranges of Colorado from August 3rd through August 11th, 2022. Samples were collected from streams and groundwater seeps as part of a comprehensive analysis within the watershed of how different geomorphic features (such as landslides and rock glaciers) along with variations in land cover (such as the presence of vegetation) affect stream water quality in this Rocky Mountain headwater environment. This dataset includes concentrations of the following in a single csv file: fluoride, chloride, sulfate, nitrate, calcium, potassium, magnesium, sodium, silicon, and total organic carbon (TOC). All concentrations are reported in mg/L. The sulfate data in this version have been updated to account for an earlier ion chromatograph instrument method error whereby sulfate and bromide peaks overlapped in calibration solution samples, biasing calculated sulfate concentrations low by 30-50%. Sulfate data reported herein are from a re-run of the samples performed in December 2024 using a corrected instrument method. All samples were stored under refrigerated conditions and filtered on initial collection.

54 ENVIRONMENTAL SCIENCES↗

Strengthening Technical Safeguards of Fresh Fuel Through International Cooperation

Over time, nuclear fuel designs have shifted towards having higher initial enrichments and a greater number of burnable poison rods. This enables increased burnup for commercial reasons. These changes have made safeguards measurements of the 235 U content in modern fresh fuel more challenging.This is addressed here through a re-evaluation of the UNCL (Uranium Neutron Collar–Light Water Reactor Fuel)poison rod correction factor. Coefficients of the poison rod correction factor were updated by simulating response of AngraII PWR fuel with a wide range of both burnable poison rods and Gd 2 O 3 contentper rod. Benchmark comparisons are made to experiments performed at Resende (Brazil) and CNEN/LASAL in Brazil. By updating these coefficients, while maintaining the same mathematical form to allow INCC to be used without software modification,it was possible to reduce error in experimental 235 U linear density assay by an order of magnitude.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗