Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Using Machine Learning Methods to Predict Bias in Nuclear Criticality Safety

The manuscript provides a description of the application of machine-learning (ML) tools to the prediction of bias in criticality safety analysis. In particular, a set of over 1000 experiments included in the Whisper package were fed into a variety of ML algorithms (notably Random Forest and AdaBoost) implemented in SciKit-Learn using k-eigenvalue sensitivities (with and without energy dependence) for individual nuclides, and optionally, the simulated k eff as the training features. Ultimately, the ML model was used to predict the bias (k sim - k exp ). The results indicate that use of energy-integrated sensitivity profiles with k sim as training features led to the best predictions as quantified by root-mean square and mean absolute errors. In particular, the best-case estimates came from AdaBoost, with a mean absolute error of 0.00174, which is less than the mean experimental uncertainty of 0.00328 for the experiments included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Technical Note: Millimeter precision in ultrasound based patient positioning: Experimental quantification of inherent technical limitations

Purpose: To identify the relevant technical sources of error of a system based on three-dimensional ultrasound (3D US) for patient positioning in external beam radiotherapy. To quantify these sources of error in a controlled laboratory setting. To estimate the resulting end-to-end geometric precision of the intramodality protocol. Methods: Two identical free-hand 3D US systems at both the planning-CT and the treatment room were calibrated to the laboratory frame of reference. Every step of the calibration chain was repeated multiple times to estimate its contribution to overall systematic and random error. Optimal margins were computed given the identified and quantified systematic and random errors. Results: In descending order of magnitude, the identified and quantified sources of error were: alignment of calibration phantom to laser marks 0.78 mm, alignment of lasers in treatment vs planning room 0.51 mm, calibration and tracking of 3D US probe 0.49 mm, alignment of stereoscopic infrared camera to calibration phantom 0.03 mm. Under ideal laboratory conditions, these errors are expected to limit ultrasound-based positioning to an accuracy of 1.05 mm radially. Conclusions: The investigated 3D ultrasound system achieves an intramodal accuracy of about 1 mm radially in a controlled laboratory setting. The identified systematic and random errors require an optimal clinical tumor volume to planning target volume margin of about 3 mm. These inherent technical limitations do not prevent clinical use, including hypofractionation or stereotactic body radiation therapy.

60 APPLIED LIFE SCIENCES↗

Estimating Sample Heterogeneity and Expected Scatter Due to Cracking in Packed Powder Samples Using a Two-Phase Model

High-precision Hugoniot measurements of heterogeneous materials are a key tool in creating accurate equations of state, but such measurements are prone to larger uncertainties than their homogeneous counterparts. To efficiently reduce these uncertainties one must estimate the relative contributions of different error sources. Sample cracking is one likely source. Here we estimate its contribution through modeling, using computed tomography scans of powdered single crystal quartz samples to estimate typical packing variation within and between samples. Samples were prepared using the same materials and methods. Furthermore, cracks were prominent in the samples. We describe a simple model to estimate shock transit time variation for a single shot due to cracking, and estimate that up to 3% variation can be attributed to these structures. This suggests that decreasing variation requires addressing such packing heterogeneities during target fabrication rather than experimental diagnostics.

36 MATERIALS SCIENCE↗

Status after 5 Years of Survival Compliance Testing in the Federal Columbia River Power System (FCRPS)

Survival studies of juvenile salmonids implanted with acoustic tags have been conducted at hydroelectric dams within the Federal Columbia River Power System (FCRPS) in the Columbia and Snake rivers between 2010 and 2014 to assess compliance with dam passage survival standards stipulated in the 2008 Biological Opinion (BiOp). For juvenile salmonids migrating downstream in the spring, dam passage survival defined as survival from the upstream dam face to the tailrace mixing zone must be ≥96% and for summer migrants, ≥93%, and estimated with a standard error ≤1.5% (i.e., 95% confidence interval of ±3%). A total of 29 compliance tests have been conducted at 6 of 8 FCRPS main-stem dams, using over 109,000 acoustic-tagged salmonid smolts. Of these 29 compliance studies, 23 met the survival standards and 26 met the precision requirements. Of the 6 dams evaluated to date, individual survival estimates range from 0.9597 to 0.9868 for yearling Chinook Salmon, 0.9534 to 0.9952 for steelhead, and 0.9076 to 0.9789 for subyearling Chinook Salmon. These investigations suggest the large capital investment over the last 20 years to improve juvenile salmon passage through the FCRPS dams has been beneficial.

acoustic tags↗

THE FOURTH US NAVAL OBSERVATORY CCD ASTROGRAPH CATALOG (UCAC4)

The fourth United States Naval Observatory (USNO) CCD Astrograph Catalog, UCAC4, was released in 2012 August (double-sided DVD and CDS data center Vizier catalog I/322). It is the final release in this series and contains over 113 million objects; over 105 million of them with proper motions (PMs). UCAC4 is an updated version of UCAC3 with about the same number of stars also covering all-sky. Bugs were fixed, Schmidt plate survey data were avoided, and precise five-band photometry was added for about half the stars. Astrograph observations have been supplemented for bright stars by FK6, Hipparcos, and Tycho-2 data to compile a UCAC4 star catalog complete from the brightest stars to about magnitude R = 16. Epoch 1998-2004 positions are obtained from observations with the 20 cm aperture USNO Astrograph's 'red lens', equipped with a 4k by 4k CCD. Mean positions and PMs are derived by combining these observations with over 140 ground- and space-based catalogs, including Hipparcos/Tycho and the AC2000.2, as well as unpublished measures of over 5000 plates from other astrographs. For most of the faint stars in the southern hemisphere, the first epoch plates from the Southern Proper Motion program form the basis for PMs, while the Northern Proper Motion first epoch plates serve the same purpose for the rest of the sky. These data are supplemented by 2MASS near-IR photometry for about 110 million stars and five-band (B, V, g, r, i) APASS data for over 51 million stars. Thus the published UCAC4, as were UCAC3 and UCAC2, is a compiled catalog with the UCAC observational program being a major component. The positional accuracy of stars in UCAC4 at mean epoch is about 15-100 mas per coordinate, depending on magnitude, while the formal errors in PMs range from about 1 to 10 mas yr{sup -1} depending on magnitude and observing history. Systematic errors in PMs are estimated to be about 1-4 mas yr{sup -1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust initialization of 2D-3D image registration using the projection-slice theorem and phase correlation

Purpose: The image registration literature comprises many methods for 2D-3D registration for which accuracy has been established in a variety of applications. However, clinical application is limited by a small capture range. Initial offsets outside the capture range of a registration method will not converge to a successful registration. Previously reported capture ranges, defined as the 95% success range, are in the order of 4-11 mm mean target registration error. In this article, a relatively computationally inexpensive and robust estimation method is proposed with the objective to enlarge the capture range. Methods: The method uses the projection-slice theorem in combination with phase correlation in order to estimate the transform parameters, which provides an initialization of the subsequent registration procedure. Results: The feasibility of the method was evaluated by experiments using digitally reconstructed radiographs generated from in vivo 3D-RX data. With these experiments it was shown that the projection-slice theorem provides successful estimates of the rotational transform parameters for perspective projections and in case of translational offsets. The method was further tested on ex vivo ovine x-ray data. In 95% of the cases, the method yielded successful estimates for initial mean target registration errors up to 19.5 mm. Finally, the method was evaluated as an initialization method for an intensity-based 2D-3D registration method. The uninitialized and initialized registration experiments had success rates of 28.8% and 68.6%, respectively. Conclusions: The authors have shown that the initialization method based on the projection-slice theorem and phase correlation yields adequate initializations for existing registration methods, thereby substantially enlarging the capture range of these methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Making Steppingstones out of Stumbling Blocks: A Bayesian Model Evidence Estimator with Application to Groundwater Transport Model Selection

Bayesian model evidence (BME) is a measure of the average fit of a model to observation data given all the parameter values that the model can assume. By accounting for the trade-off between goodness-of-fit and model complexity, BME is used for model selection and model averaging purposes. For strict Bayesian computation, the theoretically unbiased Monte Carlo based numerical estimators are preferred over semi-analytical solutions. This study examines five BME numerical estimators and asks how accurate estimation of the BME is important for penalizing model complexity. The limiting cases for numerical BME estimators are the prior sampling arithmetic mean estimator (AM) and the posterior sampling harmonic mean (HM) estimator, which are straightforward to implement, yet they result in underestimation and overestimation, respectively. We also consider the path sampling methods of thermodynamic integration (TI) and steppingstone sampling (SS) that sample multiple intermediate distributions that link the prior and the posterior. Although TI and SS are theoretically unbiased estimators, they could have a bias in practice arising from numerical implementation. For example, sampling errors of some intermediate distributions can introduce bias. We propose a variant of SS, namely the multiple one-steppingstone sampling (MOSS) that is less sensitive to sampling errors. We evaluate these five estimators using a groundwater transport model selection problem. SS and MOSS give the least biased BME estimation at an efficient computational cost. If the estimated BME has a bias that covariates with the true BME, this would not be a problem because we are interested in BME ratios and not their absolute values. On the contrary, the results show that BME estimation bias can be a function of model complexity. Thus, biased BME estimation results in inaccurate penalization of more complex models, which changes the model ranking. This was less observed with SS and MOSS as with the three other methods.

54 ENVIRONMENTAL SCIENCES↗

A Framework to Integrate Human Reliability Data Obtained from Different Sources Based on the Complexity Scores of Proceduralized Tasks

For many decades, PSA (Probabilistic Safety Assessment) or PRA (Probabilistic Risk Assessment) techniques have been used to enhance the operational safety of nuclear power plants (NPPs) based on the consideration of potential hazards that could result in an unexpected consequence. As human error is one of the potential hazards, diverse human reliability analysis (HRA) methods have been proposed to provide a systematic way to estimate the likelihood of human errors (i.e., human error probability, HEP) in specific task contexts. Accordingly, it is evident that the quality of HRA results strongly depends on the credibility of HEP estimations. This implies that, in terms of enhancing this credibility, the collection of raw information (HRA data) that is helpful for understating when and why human errors occur is a crucial issue. In order to address this issue, in this study, the feasibility of a framework to integrate HRA data obtained from different sources is investigated based on the complexity of proceduralized tasks.

99 GENERAL AND MISCELLANEOUS↗

The L_X-M relation of Clusters of Galaxies

We present a new measurement of the scaling relation between X-ray luminosity and total mass for 17,000 galaxy clusters in the maxBCG cluster sample. Stacking sub-samples within fixed ranges of optical richness, N200, we measure the mean 0.1-2.4 keV X-ray luminosity, <L{sub X}>, from the ROSAT All-Sky Survey. The mean mass, <M{sub 200}>, is measured from weak gravitational lensing of SDSS background galaxies (Johnston et al. 2007). For 9 {le} N{sub 200} < 200, the data are well fit by a power-law, <L{sub X}>/10{sup 42} h{sup -2} ergs{sup -1} = (12.6{sub -1.3}{sup +1.4}(stat) {+-} 1.6 (sys)) (<M{sub 200}>/10{sup 14} h{sup -1} M{sub {circle_dot}}){sup 1.65{+-}0.13}. The slope agrees to within 10% with previous estimates based on X-ray selected catalogs, implying that the covariance in L{sub X} and N{sub 200} at fixed halo mass is not large. The luminosity intercept is 30%, or 2{sigma}, lower than determined from the X-ray flux-limited sample of Reiprich & Boehringer (2002), assuming hydrostatic equilibrium. This slight difference could arise from a combination of Malmquist bias and/or systematic error in hydrostatic mass estimates, both of which are expected. The intercept agrees with that derived by Stanek et al. (2006) using a model for the statistical correspondence between clusters and halos in a WMAP3 cosmology with power spectrum normalization {sigma}{sub 8} = 0.85. Similar exercises applied to future data sets will allow constraints on the covariance among optical and hot gas properties of clusters at fixed mass.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise Measurement of the Spin Parameter of the Stellar-Mass Black Hole M33 X-7

In prior work, Chandra and Gemini-North observations of the eclipsing X-ray binary M33 X-7 have yielded measurements of the mass of its black hole primary and the system's orbital inclination angle of unprecedented accuracy. Likewise, the distance to the binary is known to a few percent. In an analysis based on these precise results, 15 Chandra and XMM-Newton X-ray spectra, and our fully relativistic accretion disk model, we find that the dimensionless spin parameter of the black hole primary is a{sub *} = 0.77 {+-} 0.05. The quoted 1 {sigma} error includes all sources of observational uncertainty. Four Chandra spectra of the highest quality, which were obtained over a span of several years, all lead to the same estimate of spin to within statistical errors (2%), and this estimate is confirmed by 11 spectra of lower quality. There are two remaining uncertainties: (1) the validity of the relativistic model used to analyze the observations, which is being addressed in ongoing theoretical work; and (2) our assumption that the black hole spin is approximately aligned with the angular momentum vector of the binary, which can be addressed by a future X-ray polarimetry mission.

79 ASTRONOMY AND ASTROPHYSICS↗

THE BUTTERFLY EFFECT IN THE EXTREME-MASS RATIO INSPIRAL PROBLEM

Measurements of gravitational waves from the inspiral of a stellar-mass compact object into a massive black hole are unique probes to test general relativity (GR) and massive black hole (MBH) properties, as well as the stellar distribution about these holes in galactic nuclei. Current data analysis techniques can provide us with parameter estimation with very narrow errors. However, an extreme-mass ratio inspiral (EMRI) is not a two-body problem, since other stellar bodies orbiting nearby will influence the capture orbit. Any deviation from the isolated inspiral will induce a small, though observable, deviation from the idealized waveform which could be misinterpreted as a failure of GR. Based on conservative analysis of mass segregation in a Milky-Way-like nucleus, we estimate that the possibility that another star has a semimajor axis comparable to that of the EMRI is non-negligible, although probably very small. This star introduces an observable perturbation in the orbit in the case in which we consider only loss of energy via gravitational radiation. When considering the two first-order non-dissipative post-Newtonian contributions (the periapsis shift of the orbit), the evolution of the orbital elements of the EMRI turns out to be chaotic in nature. The implications of this study are twofold. From the one side, the application to testing GR and measuring MBH parameters with the detection of EMRIs in galactic nuclei with a millihertz mission will be even more challenging than believed. From the other side, this behavior could in principle be used as a signature of mass segregation in galactic nuclei.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimation of the Mass Absorption Cross Section of the Organic Carbon Component of Aerosols in the Mexico City Metropolitan Area

Data taken from the MCMA-2003 and the 2006 MILAGRO field campaigns are used to examine the absorption of solar radiation by the organic component of aerosols. Using irradiance data from an Multi-Filter Rotating Shadowband Radiometer (MFRSR) and an actinic flux spectroradiometer, we find aerosol single scattering albedo, ω - 0,λ, as a function of wavelength, λ. We find that in near-UV spectral range (defined here as 250 nm to 400 nm) ω - 0,λ is much lower compared to ω - 0,λ at 500 nm suggesting enhanced absorption in the near-UV range. Absorption by elemental carbon, dust, or gas cannot account for this enhanced absorption leaving only the organic part of the aerosol to account for it. We use data from a surface deployed Aerodyne Aerosol Mass Spectrometer (AMS) along with the inferred ω - 0,λ to estimate the Mass Absorption Cross-section (MAC) for the organic carbon. We find that the MAC is about 10.5 m2/g at 300 nm and falls close to zero at about 500 nm; values that are roughly consistent with other estimates of organic carbon MAC. These MAC values can be considered as “radiatively correct” because when used in radiative transfer calculations the calculated irradiances match the measured irradiances at the wavelengths considered here. The uncertainties of individual estimates are quite large, ±30% at 300 nm for the random error, and even larger for a worst-case estimate of the systematic error, ±80%. The error represents the unusual circumstance where no error cancellation is permitted, and is unlikely ever to be realized.

54 ENVIRONMENTAL SCIENCES↗

Prospective estimation of organ dose in CT under tube current modulation

Purpose: Computed tomography (CT) has been widely used worldwide as a tool for medical diagnosis and imaging. However, despite its significant clinical benefits, CT radiation dose at the population level has become a subject of public attention and concern. In this light, optimizing radiation dose has become a core responsibility for the CT community. As a fundamental step to manage and optimize dose, it may be beneficial to have accurate and prospective knowledge about the radiation dose for an individual patient. In this study, the authors developed a framework to prospectively estimate organ dose for chest and abdominopelvic CT exams under tube current modulation (TCM). Methods: The organ dose is mainly dependent on two key factors: patient anatomy and irradiation field. A prediction process was developed to accurately model both factors. To model the anatomical diversity and complexity in the patient population, the authors used a previously developed library of computational phantoms with broad distributions of sizes, ages, and genders. A selected clinical patient, represented by a computational phantom in the study, was optimally matched with another computational phantom in the library to obtain a representation of the patient’s anatomy. To model the irradiation field, a previously validated Monte Carlo program was used to model CT scanner systems. The tube current profiles were modeled using a ray-tracing program as previously reported that theoretically emulated the variability of modulation profiles from major CT machine manufacturers Li et al., [Phys. Med. Biol. 59, 4525–4548 (2014)]. The prediction of organ dose was achieved using the following process: (1) CTDI{sub vol}-normalized-organ dose coefficients (h{sub organ}) for fixed tube current were first estimated as the prediction basis for the computational phantoms; (2) each computation phantom, regarded as a clinical patient, was optimally matched with one computational phantom in the library; (3) to account for the effect of the TCM scheme, a weighted organ-specific CTDI{sub vol} [denoted as (CTDI{sub vol}){sub organ,weighted}] was computed for each organ based on the TCM profile and the anatomy of the “matched” phantom; (4) the organ dose was predicted by multiplying the weighted organ-specific CTDI{sub vol} with the organ dose coefficients (h{sub organ}). To quantify the prediction accuracy, each predicted organ dose was compared with the corresponding organ dose simulated from the Monte Carlo program with the TCM profile explicitly modeled. Results: The predicted organ dose showed good agreements with the simulated organ dose across all organs and modulation profiles. The average percentage error in organ dose estimation was generally within 20% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. For an average CTDI{sub vol} of a CT exam of 10 mGy, the average error at full modulation strength (α = 1) across all organs was 0.91 mGy for chest exams, and 0.82 mGy for abdominopelvic exams. Conclusions: This study developed a quantitative model to predict organ dose for clinical chest and abdominopelvic scans. Such information may aid in the design of optimized CT protocols in relation to a targeted level of image quality.

60 APPLIED LIFE SCIENCES↗

Using Surface Remote Sensors to Derive Radiative Characteristics of Mixed-Phase Clouds: An Example from M-PACE

Measurements from ground-based cloud radar, high spectral resolution lidar and microwave radiometer are used in conjunction with a column version of the Rapid Radiative Transfer Model (RRTMG) and radiosonde measurements to derive the surface radiative properties under mixed-phase cloud conditions. These clouds were observed during the United States Department of Energy (US DOE) Atmospheric Radiation Measurement (ARM) Mixed-Phase Arctic Clouds Experiment (M-PACE) between September and November of 2004. In total, sixteen half hour time periods are reviewed due to their coincidence with radiosonde launches. Cloud liquid (ice) water paths are found to range between 11.0-366.4 (0.5-114.1) gm-2, and cloud physical thicknesses fall between 286-2075 m. Combined with temperature and hydrometeor size estimates, this information is used to calculate surface radiative flux densities using RRTMG, which are demonstrated to generally agree with measured flux densities from surface-based radiometric instrumentation. Errors in longwave flux density estimates are found to be largest for thin clouds, while shortwave flux density errors are generally largest for thicker clouds. A sensitivity study is performed to understand the impact of retrieval assumptions and uncertainties on derived surface radiation estimates. Cloud radiative forcing is calculated for all profiles, illustrating longwave dominance during this time of year, with net cloud forcing generally between 50 and 90 Wm-2.

54 ENVIRONMENTAL SCIENCES↗

Neumann Series Based Voltage Sensitivity Analysis for Three Phase Distribution System

In this letter, a simplified voltage sensitivity analysis technique that can provide accurate estimates of voltage change across the network for a given change in bus power injections in a three-phase unbalanced distribution network is proposed. This technique is derived from the first-order approximation of the Neumann series, which allows maintaining the accuracy of the solution while the computational effort is reduced. Here, the proposed technique is tested on a 559-bus unbalanced distribution system with multiple distributed generation resources. The results show that the average error in the voltage estimates with the proposed method is not more than 0.3% with the execution time of similar order relative to the state-of-the-art sensitivity analysis methods.

42 ENGINEERING↗

Real-time estimators for scattering observables: A full account of finite-volume errors for quantum simulation

The real-time correlators of quantum field theories can be directly probed through new approaches to simulation, such as quantum computing and tensor networks. This provides a new framework for computing scattering observables in lattice formulations of strongly interacting theories, such as lattice quantum chromodynamics. In this paper, we prove that the proposal of real-time estimators of scattering observables is universally applicable to all scattering observables of gapped quantum field theories. All finite-volume errors are exponentially suppressed, and the rate of this suppression is controlled by the regulator considered, namely, a displacement of the spectrum of the theory into the complex plane. A partial restoration of Lorentz symmetry by averaging over different boosts gives an additional suppression of finite volume errors. Our results also apply to the simulation of wave packet scattering, where a similar averaging is performed to construct the wave packets that regulate the finite volume effects. This result represents a necessary key step toward determining a broad class of scattering observables via quantum computing that are currently inaccessible via classical computing. Such observables are relevant for various applications, including hadron spectroscopy, hadron structure, and precision tests of the Standard Model. We also comment on potential applications of our results to traditional computational schemes.

Burbano, Ivan M. [University of California, Berkel↗

SU-G-IeP3-12: Preliminary Report On the Experience of Patient Radiation Dose Monitoring and Tracking Systems; PEMNET, Radimetrics and DoseWatch

Purpose: Three patient radiation dose monitoring and tracking (PRDMT) systems have been in operation at this institution for the past 6 months. There are useful information that should be disseminated to those who are considering installation of PRDMT programs. In addition, there are “problems” uncovered in the process of estimating fluoroscopic “peak” skin dose (PSD), especially, for those patients who received interventional angiographic studies and in conjunction with surgical procedures. Methods: Upon exporting the PRDMT data to Microsoft Excel program, the peak skin dose can be estimated by applying various correction factors including; attenuation due to the tabletop and examination mattress, table height, tabletop translation, backscatter, etc. A procedure was established to screen and divide the PRDMT reported radiation dose and estimated PSD to three different levels of threshold to assess the potential skin injuries, to assist patient follow-up, risk management and provide radiation dosimetry information in case of “Sentinel Event”. Results: The Radiation Dose Structured Report (RDSR) was found to be the prerequisite for the PRDMT systems to work seamlessly. And, the geometrical parameters (gantry and table orientation) displayed by the equipment are not necessarily implemented in the “patient centric” manner which could result in a large error in the PSD estimation. Since, the PRDMT systems obtain their pertinent data from the DICOM tags including the polarity (+ and − signs), the geometrical parameters need to be verified. Conclusion: PRDMT systems provide a more accurate PSD estimation than previously possible as the air-kerma-area dose meter become widely implemented. However, care should be exercised to correctly apply the geometrical parameters in estimating the patient dose. In addition, further refinement is necessary for these software programs to account for all geometrical parameters such as the tabletop translation in the z-direction in particular.

60 APPLIED LIFE SCIENCES↗