Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diameter distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

On the burning behavior of pulverized coal chars

A model that predicts the physical changes that pulverized coal char particles undergo during combustion has been developed. In the model, a burning particle is divided into a number of concentric annular volume elements. The mass loss rate, specific surface area, and apparent density in each volume element depend upon the local particle conditions, which vary as a consequence of the adsorbed oxygen and gas-phase oxygen concentration gradients inside the particle. The model predicts the particle's burning rate, temperature, diameter, apparent density, and specific surface area as combustion proceeds, given ambient conditions and initial char properties. A six-step heterogeneous reaction mechanism is used to describe carbon reactivity to oxygen. A distributed activation energy approach is used to account for the variation in desorption energies of adsorbed O-atoms on the carbonaceous surface. Model calculations support the three burning zones established for the oxidation of pulverized coal chars. The model indicates two types of zone II behavior, however. Under weak zone II burning conditions, constant-diameter burning occurs up to 30% to 50% conversion before burning commences with reductions in both size and apparent density. Under strong zone II conditions, particles burn with reductions in both size and apparent density after an initial short period (conversion) of constant-diameter burning. Model predictions reveal that early in the oxidation process, there is mass loss at constant diameter under all zone II burning conditions. Such weak and strong burning behavior cannot be predicted with the commonly used power-law model for the mode of burning employing a single value for the burning mode parameter. Model calculations also reveal how specific surface area evolves when oxidation occurs in the zone II burning regime. Based on the calculated results, a surface area submodel that accounts for the effects of pore growth and coalescence during combustion under zone I conditions was modified to permit the characterization of the variations in specific surface area that occur during char conversion under zones II conditions. The modified surface area model is applicable to all burning regimes. Calculations also indicate that the particle's effectiveness factor varies during conversion under zone II burning conditions. With the adsorption/desorption mechanism employed, a near first-order Thiele modulus-effectiveness factor relationship is obeyed over the particle's lifetime. (author)

01 COAL, LIGNITE, AND PEAT↗

Aerodynamic Characteristics of a Circular Cylinder at Mach Number of 6.86 and Angles of Attack up to 90 Degrees

Pressure-distribution and force tests of a circular cylinder have been made in the Langley 11-inch hypersonic tunnel at a Mach number of 6.86, a Reynolds number of 129,000 based on diameter, and angles of attack up to 90 degrees. The results are compared with the hypersonic approximation of Grimminger, Williams, and Young and with a simple modification of the Newtonian flow theory. The comparison of experimental results shows that either theory gives adequate general aerodynamic characteristics but that the modified Newtonian theory gives a more accurate prediction of the pressure distribution. The calculated crossflow drag coefficients plotted as a function of crossflow Mach number were found to be in reasonable agreement with similar results obtained from other investigations at lower supersonic Mach numbers. Comparison of the results of this investigation with data obtained at a lower Mach number indicates that the drag coefficient of a cylinder normal to the flow is relatively constant for Mach numbers above about 4.

Penland, Jim A↗

Mechanical properties of nanoporous gold in tension

We report results of the tensile properties of nanoporous gold (NPG) as a function of the density and average ligament diameter. As-dealloyed tensile samples were thermally treated to coarsen the length scale of the NPG structure while increasing the sample density resulting from thickness reductions. The behaviors of samples with mean ligament diameters ranging from 30 to 750 nm and corresponding densities ranging from 0.30 to 0.57 that of bulk gold were examined. Digital image analysis was used to obtain ligament size histograms that were fit to the Weibull distribution. The Young's modulus was found to obey a power law, but with an exponent larger than that predicted by Gibson-Ashby scaling. The fracture behavior showed a brittle-ductile transition as a function of increasing ligament size. For samples characterized by a mean ligament diameter less than ~ 220 nm, the tensile behavior was linear elastic to sample fracture while samples with larger scale ligaments showed macroscopic yielding prior to fracture. These results are interpreted within the framework of extreme value statistics.

36 MATERIALS SCIENCE↗

Texture analysis of small renal cell carcinomas at MDCT for predicting relevant histologic and protein biomarkers

Purpose: To assess CT texture features of small renal cell carcinomas (≤ 4cm) for association with key pathologic features including protein biomarkers. Methods: Quantitative CT texture analysis (CTTA) of small renal cancers (≤ 4cm) was performed on non-contrast and portal venous phase abdominal MDCT scans with an ROI drawn at the largest cross-sectional diameter of the tumor using commercially available software. Texture parameters including mean pixel attenuation, the standard deviation (SD) of the pixel distribution histogram, entropy, the mean of positive pixels, the skewness (i.e., asymmetry) of the pixel histogram, kurtosis (i.e., peakness) of the pixel histogram, and the percentage of positive pixels were correlated with pathologic data from surgical resection, including histology and nuclear grade, as well as microarray analysis in a subset (n = 40) including Ki67 index, CRP, and neovascularization (CD105/CD31). Results: Portal venous phase images were available in 249 patients (105 women, 144 men; mean age, 56.7 years) with tumors ≤ 4cm (mean, median, range, ± SD; 2.66, 2.60, 0.3–4.0 ± 0.85 cm). CT texture features of standard deviation, mean of the positive pixels, and entropy of the pixel histogram were significantly associated with histologic cell type (clear vs. non-clear; p < 0.001). Entropy and mean of the positive pixels also showed an association with nuclear grade, although not statistically significant. In the microarray analysis subset, kurtosis of the pixel histogram was associated with CD105/CD31 (p = 0.05). SD also showed some association with CD 105 positivity (p = 0.02) and CAIX expression (p = 0.01). Non-contrast CT images were available in 174 patients (72 women, 102 men; mean age, 57.5 years). Although the association with histology was not as strong as on the portal venous phase, in the subset of patients with microarray data, SD was found to correlate with CRP (p = 0.08), kurtosis with CRP (p = 0.004), CD105/CD31 (p = 0.002), and with Ki 67 index (p < 0.001). Conclusion: CT texture features were significantly associated with important histopathologic features in small renal cancers. These non-invasive measures can be performed retrospectively and may provide useful information when determining follow-up and treatment of small renal cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D pore analysis of gasoline particulate filters using X-ray tomography: impact of coating and ash loading

Since particulate emissions control technologies are dependent on filtration technologies, development of porous materials with optimized pore structures is crucial to improve filtration efficiency and pressure drop across filters. Despite increasing attention to 3D measurements of porous materials, there are few reports of pore structure investigations of diesel/gasoline particulate filters (D/GPFs) using 3D visualization techniques. Here, GPF 3D pore structures were examined using X-ray tomography (XRT) to identify the impacts of catalyst coating or ash loading. Voxel resolution of 2.93 mu m made it impossible to distinguish coating or ash materials from the cordierite substrate or to recognize smaller pores than the voxel resolution. However, pores up to 200 mu m, which are responsible for the most pore volume, were successfully analyzed. Coating and ash loading resulted in lowering average pore diameter, total porosity, and open porosity, as the peak density of pore diameter at 60 mu m decreased, while pores below 20 mu m increased. Also, the visualized closed pores, which were homogeneously distributed throughout the bare filter, tended to get larger from inlet to outlet sides and more likely to be on the surface inlet due to coating and ash loading, indicating gas pathways originally existing in open pores were blocked due to coating and ash loading, leading to increased pressure drop. The ash impact was found to be more noticeable on mid and back positions than on front position. In addition, the investigation of areal porosity along the direction of gas flow suggested that while ash penetration could reach the outlet side as noted from increased closed pore population, most ash particles would be contained up to 150 mu m. Lastly, the 2D crosscut microscopic analysis that requires destructive procedures with the limited examination area could provide underestimation of ash penetration, whereas the 3D XRT analysis seems to provide more accurate information of pore structure changes due to ash loading at different locations.

36 MATERIALS SCIENCE↗

Study on premixed combustion in cylindrical micro combustors: Transient flame behavior and wall heat flux

The micro combustor is a key component of the micro thermophotovoltaic (TPV) system. Improving the wall temperature of the micro combustor is an effective way to elevate the system efficiency. An experimental study on the wall temperature and radiation heat flux of a series of cylindrical micro combustors (with a backward-facing step) was carried out. For the micro combustors with d = 2 mm, the regime of successful ignition (under the cold wall condition) was identified for different combustor lengths. Acoustic emission was detected for some cases and the emitted sound was recorded and analyzed. Under the steady-state condition, the effects of the combustor diameter (d), combustor length (L), flow velocity (u{sub 0}) and fuel-air equivalence ratio ({phi}) on the wall temperature distribution were investigated by measuring the detailed wall temperature profiles. In the case that the micro combustor is working as an emitter, the optimum efficiency was found at {phi} {approx} 0.8, independent of the combustor dimensions (d and L) and the flow velocity. Under the experimental conditions employed in the present study, the positions of the peak wall temperature were found to be about 8-11 mm and 4-6 mm from the step for the d = 3 mm and d = 2 mm micro combustors, respectively, which are 8-11 and 8-12 times of their respective step heights. This result suggests that the backward-facing step employed in the combustor design is effective in stabilizing the flame position. (author)

30 DIRECT ENERGY CONVERSION↗

Modeling Pathologic Response of Esophageal Cancer to Chemoradiation Therapy Using Spatial-Temporal {sup 18}F-FDG PET Features, Clinical Parameters, and Demographics

Purpose: To construct predictive models using comprehensive tumor features for the evaluation of tumor response to neoadjuvant chemoradiation therapy (CRT) in patients with esophageal cancer. Methods and Materials: This study included 20 patients who underwent trimodality therapy (CRT + surgery) and underwent {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) both before and after CRT. Four groups of tumor features were examined: (1) conventional PET/CT response measures (eg, standardized uptake value [SUV]{sub max}, tumor diameter); (2) clinical parameters (eg, TNM stage, histology) and demographics; (3) spatial-temporal PET features, which characterize tumor SUV intensity distribution, spatial patterns, geometry, and associated changes resulting from CRT; and (4) all features combined. An optimal feature set was identified with recursive feature selection and cross-validations. Support vector machine (SVM) and logistic regression (LR) models were constructed for prediction of pathologic tumor response to CRT, cross-validations being used to avoid model overfitting. Prediction accuracy was assessed by area under the receiver operating characteristic curve (AUC), and precision was evaluated by confidence intervals (CIs) of AUC. Results: When applied to the 4 groups of tumor features, the LR model achieved AUCs (95% CI) of 0.57 (0.10), 0.73 (0.07), 0.90 (0.06), and 0.90 (0.06). The SVM model achieved AUCs (95% CI) of 0.56 (0.07), 0.60 (0.06), 0.94 (0.02), and 1.00 (no misclassifications). With the use of spatial-temporal PET features combined with conventional PET/CT measures and clinical parameters, the SVM model achieved very high accuracy (AUC 1.00) and precision (no misclassifications)—results that were significantly better than when conventional PET/CT measures or clinical parameters and demographics alone were used. For groups with many tumor features (groups 3 and 4), the SVM model achieved significantly higher accuracy than did the LR model. Conclusions: The SVM model that used all features including spatial-temporal PET features accurately and precisely predicted pathologic tumor response to CRT in esophageal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of excess Te on flux inclusion formation in the growth of cadmium zinc telluride when forced melt convection is applied

The presence of second phase defects, particularly flux inclusions of tellurium rich composition, are of great concern for charge collection efficiency in cadmium zinc telluride (CZT) and cadmium telluride (CT) material intended for applications such as radiation detection. These inclusions can distort applied electric field lines within the detector as well as act as trapping centers for charge carriers. Reduction and/or elimination of these inclusions is required to achieve appropriate charge collection efficiencies, especially in detectors of thicknesses greater than 5 mm. These so-called flux inclusions are understood to form as a consequence of constitutional undercooling at the crystal growth interface. In this study, a forced melt convection technique was applied in Vertical Bridgman (VB) melt growth of CZT without reducing imposed growth rates of ~2 mm/hr. Several rotation profiles were tested while adjusting the melt composition from 51.62 to 61.75 atomic percent (at%) Te where the Te concentration was initially increased to improve overall material purity. With forced melt convection, the best inclusion distributions were achieved with highly Te rich melt compositions, far beyond the stoichiometric composition range for the CZT system. Average inclusion diameters were reduced to 2 µm while inclusions greater than 5 µm were essentially eliminated. Composition analyses of these ingots revealed near equilibrium concentrations of Te, even with ingots grown from Te concentrations as high as 61.75 at% Te. In this paper, a recipe for the reduction of inclusions in CZT melt growth is put forward and the implications of this method on our understanding of inclusion formation are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Infrared laser ablation of poly(vinylidene fluoride): The Loss of HF

The mechanism and kinetics of infrared laser ablation of poly(vinylidene fluoride) (PVDF) in vacuum have been investigated to understand how this can be used as a polymer processing technology. The laser heats the surface and initiates decomposition of macromolecules in the molten polymer layer which rapidly leads to production of an ablative flow of polymer decomposition products. There is only a short induction period of up to 2 s before ablation begins. After the initial period, the rate of mass loss increases linearly with the time of laser exposure. Spherical particles with an average diameter of about 100 nm are formed on the surface of the powder coating obtained by laser ablation. Here, the particle distribution ranges from 50 nm to 300 nm. The main gaseous product of ablation is HF from dehydrofluorination. A second important ablation process is the formation of gaseous carbenes generated during secondary reactions. Proposed ablation reactions due to laser-induced thermal dehydrofluorination occur in two stages. In the first stage, a double bond appears in PVDF due to direct loss of HF. Subsequent detachment of HF leads to the appearance of both triple bonds and cumulene bonds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Zeolite-supported Metal Complexes of Rhodium and of Ruthenium: a General Synthesis Method Influenced by Molecular Sieving Effects

A general method for synthesis of supported metal complexes having a high degree of uniformity is presented, whereby organometallic precursors incorporating acetylacetonate (C{sub 5}H{sub 7}O{sub 2}{sup -}, acac) ligands react with zeolites incorporating OHgroups near Al sites. The method is illustrated by the reactions of Rh(acac)(CO){sub 2} and of cis-Ru(acac){sub 2}({eta}{sup 2}-C{sub 2}H{sub 4}){sub 2} with zeolites slurried in n-pentane at room temperature. The zeolites were H-Beta, H-SSZ-42, H-Mordenite, and HZSM-5. Infrared (IR) and extended X-ray absorption fine structure spectra of the zeolites incorporating rhodium complexes indicate the formation of Rh(CO){sub 2}{sup +} bonded near Al sites; similar results have been reported for the formation of zeolite-supported Rh({eta}{sup 2}-C{sub 2}H{sub 4}){sup 2+} from Rh(acac)({eta}{sup 2}-C{sub 2}H{sub 4}){sub 2}. IR spectra of the supported rhodiumgem-dicarbonyls include sharp, well-resolved {nu}{sub CO} bands, demonstrating that the sites surrounding each metal complex are nearly equivalent. The frequencies of the {nu}{sub CO} bands show how the composition of the zeolite influences the bonding of the supported species, demonstrating subtle differences in the roles of the zeolite as ligands. When the zeolite has pore openings larger than the critical diameter of the precursor organometallic compound, the latter undergoes facile transport into the interior of the zeolite, so that a uniform distribution of the supported species results, but when the precursors barely fit through the zeolite apertures, the mass transport resistance is significant and the supported metal complexes are concentrated near the pore mouths.

36 MATERIALS SCIENCE↗

Double-layer ion acceleration triggered by ion magnetization in expanding radiofrequency plasma sources

Ion energy distribution functions downstream of the source exit in magnetically expanding low-pressure plasmas are experimentally investigated for four source tube diameters ranging from about 5 to 15 cm. The magnetic-field threshold corresponding to a transition from a simple expanding plasma to a double layer-containing plasma is observed to increase with a decrease in the source tube diameter. The results demonstrate that for the four geometries, the double layer and the accelerated ion beam form when the ion Larmour radius in the source becomes smaller than the source tube radius, i.e., when the ions become magnetized in the source tube.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of gamma irradiation on hyaluronic acid and dipalmitoylphosphatidylcholine (DPPC) interaction

DPPC lipids are the major component constituting the biological membrane, and their importances in various physiological functions are well documented. Hyaluronic acid (HA) in the synovial joint fluid functions as a lubricant, shock absorber and a nutrient carrier. Gamma irradiation has also been found to be effective in depolymerizing and cleaving molecular chains related to free radicals, thus extends with changes in chemical composition as well as its physiological functions. This research are conducted to investigate the hyaluronic acid (HA) and 1,2-dipalmitoyl-sn-glycero-3-phosphatidylcholine (DPPC) interaction in form of vesicles and its effect to gamma radiation. The size of DPPC vesicles formed via gentle hydration method is between 100 to 200 nm in diameter. HA (0.1, 0.5 and 1.0 mg/ml) was added into the vesicles and characterized by using TEM to determine vesicle size distributions, fusion and rupture of DPPC structure. The results demonstrated that the size of the vesicles approximately between 200 to 300 nm which caused by vesicles fusion with HA and formed even larger vesicles. After being irradiated by 0 to 200 Gy, the size of vesicles decreased as HA was degraded. To elucidate the mechanism of these effects, FTIR spectra were carried out and have shown that at absorption bands at 1700–1750 cm{sup −1} due to formation of carboxylic acid and leads to alteration of HA structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis, structural characterization and magnetic properties of Fe/Pt core-shell nanoparticles

Structural and magnetic properties of Fe/Pt core-shell nanostructure prepared by a sequential reduction process are reported. Transmission electron microscopy shows nearly spherical particles fitting a lognormal size distribution with D{sub o} = 3.0 nm and distribution width λ{sub D} = 0.31. In x-ray diffraction, Bragg lines only from the Pt shell are clearly identified with line-widths yielding crystallite size = 3.1 nm. Measurements of magnetization M vs. T (2 K–350 K) in magnetic fields up to 90 kOe show a blocking temperature T{sub B} = 13 K below which hysteresis loops are observed with coercivity H{sub C} increasing with decreasing T reaching H{sub C} = 750 Oe at 2 K. Temperature dependence of the ac susceptibilities at frequencies f{sub m} = 10 Hz–5 kHz is measured to determine the change in T{sub B} with f{sub m} using the Vogel-Fulcher law. This analysis shows the presence of significant interparticle interaction, the Neel-Brown relaxation frequency f{sub o} = 5.3 × 10{sup 10 }Hz and anisotropy constant K{sub a} = 3.6 × 10{sup 6 }ergs/cm{sup 3}. A fit of the M vs. H data up to H = 90 kOe for T > T{sub B} to the modified Langevin function taking particle size distribution into account yields magnetic moment per particle consistent with the proposed core-shell structure; Fe core of 2.2 nm diameter and Pt shell of 0.4 nm thickness.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Radioimmunotherapy with radioactive nanoparticles: First results of dosimetry for vascularized and necrosed solid tumors

Radioimmunotherapy uses monoclonal antibodies that are still labeled with only one radioactive atom. The aim of this paper is to assess, by means of MCNPX simulations, the doses delivered around and throughout a solid tumor when the radioactive atom linked to each antibody is replaced by a 5 nm diameter nanoparticle composed of numerous radionuclides. A new model for a spherical vascularized tumor has been developed in which the antibody distributions inside the tumor can be uniform or heterogeneous. It is also possible to simulate a central necrotic core inside the tumor where the concentration of radiolabeled antibodies is assumed to be zero. Dosimetry calculations have been performed for the beta-emitting radionuclide {sup 90}Y{sub 2}O{sub 3}. Preliminary results show that the irregularity of vasculature and the presence of a necrotic core have a noticeable influence on the deposited dose profiles. Moreover, with a total activity of 5 and 34 MBq for tumor radii of 0.5 and 1.0 cm, respectively, viable tumor cells can receive doses of up to 50 Gy, even if high nonuniformity of the total activity is observed in the tumor. These simulations still require accurate information about antibody characteristics and necrosis sizes but clearly confirm that the use of monoclonal antibodies conjugated to nanoparticles could lead to a considerable enhancement of treatment efficacy against cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-171: Characterization of the New Xoft Axxent Electronic Brachytherapy Source Using PRESAGE Dosimeters

Purpose: To characterize the Xoft Axxent electronic brachytherapy source using PRESAGE™ dosimeters to obtain independent confirmation of TG-43U1 dosimetry values from previous studies and ascertain its reproducibility in HDR brachytherapy. Methods: PRESAGE™ dosimeters are solid, polyurethane-based dosimeters doped with radiochromic leucodyes that produce a linear optical-density response when exposed to radiation. Eight 1-kg dosimeters were scanned prior to irradiation on an optical-CT scanner to eliminate background signal and any optical imperfections from each dosimeter. To quantify potential imaging artifacts due to oversaturated responses in the immediate range of the source, half of the eight dosimeters were cast with a smaller channel diameter of 5.4 mm, and the other half were cast with a larger channel diameter of 15mm. During irradiation, the catheters were placed in the center of each channel. Catheters fit the 5.4mm diameters channels whereas polyurethane plugs were inserted into the larger channels to create a sturdy, immobile catheter which allowed uniform dose distributions. Two dosimeters of each 5.4mm and 15mm were irradiated at either 1517.3 cGy or 2017.5 cGy. Post-irradiation scans were performed within 48 hours of irradiation. A 3D reconstruction based on subtraction of these two images and the relative dose measurements were made using in-house software. Results: Comparing measured radial dose rates with previous results revealed smaller percent errors when PRESAGE™ irradiations were at lower maximum dose. The dosimeters showed small deviations in radial dose function, g{sub p} (r), from previous studies. Among the dosimeters irradiated at 1517.3 cGy, the g{sub p}(r) compared to previous studies fluctuated from 0.0043 to 0.3922. This suggests small fluctuations can drastically change radial dose calculations. Conclusion: The subtraction of pre-irradiation and post-irradiation scans of PRESAGE™ dosimeters using an optical-CT scanner shows promising results in determining 3D dosimetry for Xoft Axxent devices; however, further research is recommended. NIH Grant#: 5-U24-CA081647-13; ROI Grant#: 5R01CA100835.

60 APPLIED LIFE SCIENCES↗

Influence of the Distributed Phase of Gas Bubbles on a Pulsed Electrical Discharge in Water

The development of a pulsed electrical discharge in water with vapor–air microbubbles, the volume distribution of which in water is close to uniform, has been studied experimentally. The presence of volumetric microbubbles with an average diameter of ~50 μm and a bulk gas content of no more than 1% does not change the thermal mechanism of the development of the discharge in water with a conductivity of ~300 μS/cm at overvoltages of 1–1.5, the minimum breakdown voltage being ~9 kV. Under these conditions, the determining role is played by the surface bubbles, which change the observed mechanism of the discharge development. The discharge is initiated in the surface bubbles simultaneously on both electrodes. The growth of the cathode channel at a velocity of ~60 m/s leads to the closure of the 1-cm-long gap during a time of ~160 μs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal Runaway of Li-Ion Cells: How Internal Dynamics, Mass Ejection, and Heat Vary with Cell Geometry and Abuse Type

Thermal runaway of lithium-ion batteries can involve various types of failure mechanisms each with their own unique characteristics. Using fractional thermal runaway calorimetry and high-speed radiography, the response of three different geometries of cylindrical cell (18650, 21700, and D-cell) to different abuse mechanisms (thermal, internal short circuiting, and nail penetration) are quantified and statistically examined. Correlations between the geometry of cells and their thermal behavior are identified, such as increasing heat output per amp-hour (kJ Ah −1 ) of cells with increasing cell diameter during nail penetration. High-speed radiography reveals that the rate of thermal runaway propagation within cells is generally highest for nail penetration where there is a relative increase in rate of propagation with increasing diameter, compared to thermal or internal short-circuiting abuse. For a given cell model tested under the same conditions, a distribution of heat output is observed with a trend of increasing heat output with increased mass ejection. Finally, internal temperature measurements using thermocouples embedded in the penetrating nail are shown to be unreliable thus demonstrating the need for care when using thermocouples where the temperature is rapidly changing. All data used in this manuscript are open access through the NREL and NASA Battery Failure Databank.

25 ENERGY STORAGE↗