Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consumer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

An expert-systems approach to automatically determining flaw depth within Candu pressure tubes - 221

Delayed Hydride Cracking (DHC) is a crack growth mechanism that occurs in zirconium alloys, including the pressure tubes of CANDU reactors. DHC is caused by hydrogen in solution in zirconium components being diffused to any flaws present, resulting in an increased concentration of hydrogen within these flaws. An increased hydrogen concentration can lead to brittleness, followed by cracking, in high-stress regions of a pressure tube. Regular in-service ultrasonic inspection of CANDU pressure tubes aims to locate and classify any flaws that pose a potential for DHC initiation. A common approach to inspection is the use of a bespoke tool containing multiple ultrasonic transducers to ensure that each point on the pressure tube is inspected from a minimum of three angles during a scan. All flaws from within the inspected pressure tubes must be characterized prior to restarting the reactor, thus the time-consuming analysis process lies on the critical outage path. This process is manually intensive and often requires a significant amount of expert knowledge. A modular system to automatically process outage data to provide decision support to analysts has been developed. This system saves time on the critical outage path while providing repeatable and explicable measurements. Part of the analysis process requires the depth of all flaws to be measured, which is often the most time consuming stage of the analysis process. This paper describes an approach that utilizes captured analysts knowledge to perform automatic flaw depth estimation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of Passive Heat Removal Capability of FHR Based on Efficient Surrogate Model and GenFlow

Code Scaling, Applicability and Uncertainty Evaluation Methodology (CSAU) is used for quantifying reactor safety margins and works as an alternative method for licensing nuclear power plant. In the framework of CSAU, sensitivity and uncertainty analysis (SA and UA) should be performed. However, for large-scale complicated thermal hydraulics analysis simulated by code (e.g. RELAP5, CFD and subchannel analysis, the sensitivity and uncertainty analysis is really time-consuming. Furthermore, sometimes it is not feasible to perform SA and UA. Specifically, the computation time for Monte Carlo sampling or advanced LHS sampling can be neglected, but the computation time for thermal hydraulics code makes up main part of time during SA and UA process. In order to accelerate the speed of SA and UA, thermal hydraulics code can be improved based on advanced mathematic algorithm or using parallel method. However, the development for new mathematic method needs long time and strict verification and validation process is needed for a new code, which usually takes a couple of years or even longer time to have an approved code that can be used in nuclear industry. An alternative way to improve the speed of SA and UA is using surrogate model. The surrogate model is derived from the input as well as output data of the original code, assuming the code as a black box. The most common method is using response surface method (RSM) as a surrogate for the code, the input parameters are then sampled from their assumed distribution and the corresponding value of the response surface function is calculated. However, a couple of input parameters need hundreds or even thousands of original code calculations. The large number of runs is an obvious disadvantage of this method. Besides, the second disadvantage is an appropriate response surface function must be selected (e.g. quadratic, cubic, quartic, with or without cross product terms, or using a non-polynomial form) to avoid the overfit and underfit problem. This process is time consuming and expensive. Polynomial chaos expansion method is a reasonably fast and attractive alternative, stochastic model. The chaos expansion provides an efficient high-order method of including non-linear effects in stochastic analysis. Usually, the information about the model parameters and their probability distribution is limited and the dependence between them is not known. However, if arbitrary polynomial chaos is used, instead of assuming probability distribution for input parameters which may introduces additional subjectivity into the analysis, the available information can directly and most purely be used in stochastic analysis based on arbitrary data distribution. Thus, it is not necessary to know the exact probability density functions to perform SA and UA based on arbitrary polynomial chaos (aPC). The aPC has been applied for uncertainty quantification in many fields (e.g. in solid mechanics, fluid flows, thermal sciences), and become widely used in nuclear industry recently. Mk1 PB-FHR is a small modular fluoride-salt-cooled, high-temperature reactors (FHRs) that is a concept design by University of California, Berkeley (UCB). It has inherently safe features like natural-circulation-driven systems (e.g. direct reactor auxiliary cooling system (DRACS)) to passively remove decay heat from the reactor core during design basis and beyond design. It is necessary to perform SA and UA, since the licensing process of this new kind of reactor is under way and there are many design parameters that have not been fixed. Current nuclear commercial codes, such as RELAP5, have mainly been developed for light water reactors, which require the use of comprehensive two-phase flow models. This capability is not required to simulate single-phase flow phenomena in FHRs, whose baseline coolant, flibe, remains liquid up to 1430 deg. C at atmospheric pressure. The FHR advanced natural circulation analysis (FANCY) code has been developed specifically for FHR technology modeling and validation work has been performed by using CIET data in UCB. The code has been renamed General Flow (GenFlow) because it has been further developed to have the capability to model complicated pipework system based on object-oriented concept for user friendly purpose. Besides, it can be used to simulate both the force circulation as well as natural circulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Evaluation of Energy Storage Options for Nuclear Power

The dynamics of energy generation, delivery, and consumption in the United States continue to change as new energy sources come online and consumers purchase more energy-intensive devices. The percentage of electricity generation from variable renewable energy sources like wind and solar power has grown year after year. Meanwhile, the evolution of electric vehicles, smart devices, and consumer appliances is changing the way that electricity is used. As a result of these trends, nuclear power plants (NPPs) are being asked to operate more flexibly. Newly constructed, advanced nuclear power plants (A-NPPs) will likely need to adapt their business models with these market shifts in mind. In the future, A-NPPs might operate in an electricity system that values flexibility (e.g. fast ramping) more than stability (e.g. baseload supply). The current fleet of NPPs is struggling to remain economically viable in competitive markets that favor low natural gas prices and renewable energy sources with low marginal costs. Rising construction costs and ambiguous national policies have only added to the challenges facing plant operators. The industry as a whole is in decline, with 19 reactors in the process of being decommissioned and 5 of these plants retiring in the past decade. However, NPPs also provide several performance and environmental benefits by maintaining a high capacity factor and generating almost zero greenhouse gas (GHG) emissions over the life cycle of the plant. As more areas of energy consumption in the United States are electrified, NPPs could potentially replace coal and natural gas as a source of heat and power to help decarbonize the U.S. energy mix. Improving the flexibility of newly constructed A-NPPs to increase revenue through market hedging and reduce costs via stable operation was explored in this analysis. The increasing penetration of variable energy resources could contribute to the uncertainty of electricity demand, which could in turn increase the need for dispatchable electricity generating units. This role is currently filled by inexpensive natural gas combined cycle (NGCC) plants, whereas coal and NPPs have traditionally been called upon to provide baseload power by maintaining a constant power output. As wholesale electricity prices continue to fall due to low natural gas prices and federally subsidized renewable energy, this business model has begun to fail, resulting in incidences of NPPs selling electricity at a loss. Since it has not been economically favorable for NPPs to operate flexibly in this situation in the past, due to their low variable costs compared to fossil fuel power plants, NPPs in the United States were not built with this purpose in mind. Therefore, legacy NPPs have had difficulty adapting to these shifting dynamics due to regulatory and technical constraints, coupled with a lack of meaningful experience. NPPs in France have operated in this manner for years, due to a much higher percentage of baseload generators and a lower percentage of fast-ramping NGCC plants. The integration of energy storage technologies (ESTs) alongside newly constructed A-NPPs will be investigated in this analysis as an alternative method for helping NPPs resolve the economic challenges they currently face. Although the deregulation of energy markets in the United States is responsible for much of the increased competition from natural gas and renewable energy that has negatively impacted NPPs, this process has also led to the creation of ancillary service markets. ESTs can provide many of these services, so an integrated energy storage system could supplement both the reliability of the electricity grid and the economic performance of a NPP by bidding into these markets. However, many technical, financial, and regulatory barriers still prevent ESTs from operating profitably in this space. The purpose of this body of work is to compile a transparent database of metrics for available ESTs and identify barriers to widespread deployment. An analytical selection methodology was also developed to identify favorable technologies for integration with specific NPPs based on information supplied by an interested developer. These tools could help reduce the perceived risk surrounding investment in energy storage systems, which could help both NPPs in need of economic assistance and ESTs in need of further research and development.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Grid Intensity Map-Based Source Model for Monte Carlo Modeling of IMRT Field Irradiation - Paper 5

An accurate source model is important for TPS (Treatment Planning System) dose calculation and verification, especially for IMRT (Intensity Modulated Radiotherapy) irregular and inhomogeneous fields. Monte Carlo simulation is the most accurate way to calculate dose distributions in the heterogeneous media like human bodies. A full radiotherapy modeling generally includes Linac modeling and phantom dose calculation. Full Linac modeling is very time-consuming and requires highly detailed knowledge of the accelerator composition and structure, however, which is very difficult to obtain for commercial interests. Often all relevant parameters are not known with sufficient accuracy, and thus a time-consuming tuning of e.g. the electron beam spot size and energy must be performed. A multiple source model (MSM) regards particles coming from different parts of an accelerator as if they are coming from different virtual sources. MSM uses a set of virtual sources representing the treatment beam (e.g. primary photons, head scatter, electron contamination) by a set of analytic functions or histograms with parameters derived from dosimetric measurements or a full MC simulation. Tillikainen et al built a three sub-source model by matching with measurement data using an automatic process to optimize the free model parameters for a Varian 2100 C/D accelerator. Lin et al have built a convenient five-photon-sub-source model for Varian 2300C 6 MV-X beam based on Monte Carlo simulated Linac for ARTS (Accurate Radiotherapy System). The particle generation of MSM is very fast compared to full Linac simulation, and its sampling efficiency is not limited by the size of the phase space file (PSF). However, generally MSM is generated based on regular field PSF and needs an irregular component to form the beam shape meanwhile apt to bringing error Linac modeling and MSM producing from PSF analysis actually both are multi-freedom optimization process by adjusting several parameters (e.g. electron energy and angular divergence). Linac modeling adjusts its parameters from the beginning of electron hitting target through all components to fit the simulation to the measurement. MSM tunes its PSF-derived parameters by optimizing to minimize the deviations between the simulation and the measurement. Since the full Linac modeling and the MSM model both need to fine tune their parameters to match the simulation to the measurement, and sometimes maybe offsets the real accelerator for its multi-parameter optimization process. So, why not fine tune directly all source model parameters just behind all Linac components to fit the simulation to the measurement? A grid intensity-based surface source model was suggested here, which assumed the particle emitting from the bottom surface of Linac last beam trimmer MLC (Multi Leaf Collimator). The particle emitting position is sampled on the grid intensity map optimized by TPS, and the particle weight is adjusted by its original grid intensity. This source model not only takes advantage of the Monte Carlo method in the heterogeneous media, but also avoids effectively the transportation speed shortcoming of Monte Carlo simulation through Linac components. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Induced Radioactivity Analysis for the NSRL Linac in China Using Monte Carlo Simulations and Gamma Spectroscopy - Paper 141

The Synchrotron Radiation Facility of the National Synchrotron Radiation Laboratory (NSRL) located in Hefei, China consists of a 200-MeV electron linear accelerator and an 800-MeV electronic storage ring. Constructed in 1989, the 200-MeV Electron linac is one of the earliest high-energy electron linear accelerators in China. The NSRL is a large-scale experiment device, having been operated more than twenty years, so it is hard to give a historical recount about the injection of NSRL Linac. Lower-energy electrons emitted from the accelerator electron gun are progressively accelerated to about 200 MeV in five acceleration tubes, and then are injected into the electron storage ring, reaching the final energy of 800 MeV. The linear accelerator is a traveling wave linear accelerator, consisting of pre-injection, four 6-m acceleration segment, some beam sensing elements, and focusing inserts. The electrons are accelerated in the acceleration tubes to 32 MeV, 74 MeV, 116 MeV, 158 MeV, respectively, and the electronic energy reaches 200 MeV at the end of the acceleration trip. A scraper is used for beam collimation and is located at the end of each acceleration tube, with a length that increases with the energy to provide sufficient collimation. The NSRL Linac was retired in 2012 due to a plan to upgrade the facility. The decommissioning produced many real challenges related to the methods to handle the large size of the device and the time required to store structural materials until the radioactivity is reduced in the waste repository. These problems should be solved as soon as possible in order for the upgrade to proceed smoothly. At present, no prior decommissioning experience existed in China on such a high-energy electron linear accelerator. Therefore, the decommission project provided an opportunity to study and evaluate the challenges, in particular, involving the induced radioactivity for the purposes of radiation protection. For a well-shielded accelerator facility, the induced radioactivity is an important source of radiation for people who perform the decommissioning. In addition, information on the level of induced radioactivity is needed for disposing of the retired accelerator materials. Therefore it is significant to predict such radioactivity level accurately. However, the induced radioactivity study for such type high-energy electron linear accelerator is very seldom. Particle accelerators that operate at energy greater than 10 MeV will produce induced radioactivity due to well-known photonuclear interactions. However, the assessment of such as induced radioactivity of large-scale installations is a time-consuming process. Experimental methods are time-consuming and require special radiation safety measures to protection the investigators. On the other hand, empirical formula cannot yield sufficiently accurate results. Therefore, Monte Carlo simulation method is the primary means to study such problems. In the decommissioning process of the NSRL Linac, the induced radioactivity assessment will be based on Monte Carlo simulation method as the main auxiliary means to expand a series of studies. (authors)

43 PARTICLE ACCELERATORS↗

Adaptive Laboratory Evolution for Enhanced Performance of Cupriavidus Necator on Formic Acid

The threat of global warming, driven by rising carbon emissions, highlights the need to decarbonize our economy. This requires innovative solutions for managing carbon waste and its effective utilization. One promising method for CO2 capture and sequestration is the electrochemical reduction of CO2 to formic acid, a soluble C1 molecule that can be used to store carbon and energy, and as a feedstock for biological conversion. Cupriavidus necator H16, a soil bacterium capable of consuming and growing on formic acid as its sole carbon and energy source, is well positioned to upgrade CO2-derived formic acid into platform chemicals and fuel precursors. To improve the performance of C. necator on formic acid, adaptive laboratory evolution (ALE), a proven tool for improving microbial fitness, has been conducted using continuous pH-stat bioreactors. The system works on the basis that consumption of formic acid raises the pH and triggers the addition of more formic acid to maintain the pH (in this case 6.7), such that formic acid is provided at the same rate as it is consumed. This system has been coupled with level control to achieve continuous fermentation where cells acquiring mutations that improve growth on formic acid become more abundant in the population, from which they can be isolated and characterized. During developmental experiments it was discovered that formic acid accumulated to inhibitory levels. It was determined that the nitrogen source, ammonium hydroxide, must be tailored to the carbon consumption to avoid formic acid accumulation. The ALE ran in three lineages for approximately 3000 hours and more than 500 generations. Evolved isolates obtained from each lineage demonstrated an increase in growth rate in conjunction with improve formate utilization compared to the parental strain when evaluated in pH-stat bioreactors. The isolates with improved performance were then subjected to whole genome sequencing to identify potentially causative mutations. Mutations in several key genes across different lineages have been found and will be evaluated individually and in combination to identify those that improve growth on formic acid. Incorporating these mutations into production strains has the potential to greatly improve formic acid conversion and further industrial decarbonization.

adaptive laboratory evolution↗

“Max-tech FHR”: What is the maximum technically achievable water delivery capacity from a single 120 V plug?

Electrifying water heating will require affordable, direct drop-in replacements for existing gas water heaters that meet consumer expectations for hot water delivery. For many replacement scenarios, affordability requires a replacement option with like-for-like physical product dimensions, and existing consumer expectations presume a large delivery capacity from a small water heater. This work explores the technical potential for hot water delivery capacity for a heat pump water heater (HPWH) powered from a common 120 V plug. Delivery capability in this work is quantified by two metrics: the First Hour Rating (FHR) defined in the Code of Federal Regulations, and a real-world draw profile that resulted in hot water runout during field studies of 120 V HPWHs. The work focuses on the common “tall-and-slim” gas water heater product category, with external product dimensions of 20 inch diameter and 60 inch height. Using a simulation model in DOE/ORNL Heat Pump Design Model, validated by experimental baseline testing of a commercially available 120 V HPWH model, several measures were evaluated to maximize the delivery capacity of a 120 V HPWH. The 120 V HPWH was constrained by 1) external product dimensions of 20 in diameter and 60 inch height, 2) electrical power of 1.5 kW (85% of the available power from a dedicated 120 V, 15 A circuit), and 3) commercially-available components. The measures implemented included a large compressor, a pumped loop with plate heat exchanger to maximize tank stratification, enlarged heat exchangers, and relatively thin insulation to maximize the water storage volume.

Gluesenkamp, Kyle↗

Energy Efficiency Requirements for Acquisition Professionals

Federal agencies are required to purchase products as certified by EPA or designated by DOE’s Federal Energy Management Program (FEMP). The two programs cover different products, sizes and applications. These requirements also have an associated FAR clause, FAR 52.223-15. They apply to both energy-consuming products and services that use energy-consuming products.

Ackerman, Allison↗

Advanced Building Technologies for Energy Savings and Decarbonization

The building sector is a major consumer of energy, making it essential to explore innovative strategies for reducing its environmental impact. As we shift our focus toward decarbonization and electrification, the need for advanced building operation techniques and equipment becomes increasingly urgent. These advancements are crucial for maintaining or enhancing indoor environmental quality while simultaneously minimizing energy consumption. This Special Issue aims to showcase cutting-edge technologies in building energy management, alongside effective measurement and verification methods. It will also address fault detection and diagnosis approaches, leveraging both simulation and experimental studies. The ultimate goal is to highlight solutions that not only reduce CO₂ emissions but also improve indoor environmental quality, creating healthier and more sustainable living and working spaces. By presenting a diverse array of research contributions, this Special Issue will provide valuable insights into the latest advancements in building energy technologies. It will drive the discussion around effective strategies for energy efficiency and environmental sustainability in the building sector. These efforts can help transform buildings from energy consumers into more efficient spaces that contribute to reducing our overall carbon footprint.

Im, Piljae↗

Zero-power wireless system for crop water content monitoring

Zero power wireless sensors, devices, and systems are used for crop water content monitoring. The sensors consume no power while monitoring for the presence of dry crop conditions. Infrared reflectance from plants is measured and when selected spectral conditions are met, a circuit is closed, activating an alarm, an RFID tag, or a radio transmitter. The deployed sensors consume no power while monitoring, reducing or eliminating the need to change batteries.

Rinaldi, Matteo↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Large-Amplitude Motion Platform: A New Ocean Simulator Can Help Technologies Succeed

It's not always easy to build technologies hearty enough to operate in a powerful ocean environment. And subjecting promising prototypes to real ocean waves can be an expensive, time-consuming, and risky way to get these technologies ready for the high seas. Now, with the National Laboratory of the Rockies' (NLR's) testing platform, called the large-amplitude motion platform (or LAMP for short): www.nlr.gov/water/motion-platform, our experts can replicate powerful ocean waves in a low-risk laboratory setting. The LAMP, coupled with NLR's diverse array of testing instrumentation, can help technology developers rapidly hone their prototypes before embarking on a potentially costly and time-consuming ocean trial.

16 TIDAL AND WAVE POWER↗

Data for "Enhancing Lipid Production in Plant Cells through Automated High-Throughput Genome Engineering and Phenotyping"

Plant bioengineering is a time-consuming and labor-intensive process with no guarantee of achieving desired traits. Here, we present a fast, automated, scalable, high-throughput pipeline for plant bioengineering (FAST-PB) in maize (Zea mays) and Nicotiana benthamiana. FAST-PB enables genome editing and product characterization by integrating automated biofoundry engineering of callus and protoplast cells with single-cell matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). We first demonstrated that FAST-PB could streamline Golden Gate cloning, with the capacity to construct 96 vectors in parallel. Using FAST-PB in protoplasts, we found that PEG2050 increased transfection efficiency by over 45%. For proof-of-concept, we established a reporter-gene-free method for CRISPR editing and phenotyping via mutation of high chlorophyll fluorescence 136. We show that diverse lipids were enhanced up to 6-fold using CRISPR activation of lipid controlling genes. In callus cells, an automated transformation platform was employed to regenerate plants with enhanced lipid traits through introducing multigene cassettes. Lastly, FAST-PB enabled high-throughput single-cell lipid profiling by integrating MALDI-MS with the biofoundry, protoplast, and callus cells, differentiating engineered and unengineered cells using single-cell lipidomics. These innovations massively increase the throughput of synthetic biology, genome editing, and metabolic engineering and change what is possible using single-cell metabolomics in plants.

AI/ML↗

A note on minimizing time assurance tests for repairable systems

We consider assurance testing for repairable systems when supplementary information is available in addition to the data collected in the assurance test. Here, the supplementary information is incorporated using a Bayesian inferential framework. Here we consider assurance testing for a homogeneous Poisson process. In this note we consider an alternative criterion that minimizes the test time while ensuring that the requirements on the producer's and consumer's risks are met. We illustrate the use of this alternative criterion with an example.

42 ENGINEERING↗

Examination of lead concentrations in new decorative enamel paints in four countries with different histories of activity in lead paint regulation

Paints with high lead concentrations (ppm) continue to be sold around the world in many developing countries and those with economies in transition representing a major preventable environmental health hazard that is being increased as the economies expand and paint consumption is increasing. Prior lead paint testing had been performed in Brazil and India and these countries were selected to examine the impact of a new regulatory limit in Brazil and the impact of efforts of non-governmental organizations and others to stop the use of lead compounds in manufacturing paints. Armenia and Kazakhstan, in Central Asia, were selected because no information on lead concentration in those regions was available, no regulatory activities were evident and non-governmental organizations in the IPEN network were available to participate. Another objective of this research was to evaluate the lead loading (µg/cm{sup 2}) limit determined by X-Ray Fluorescence (XRF) for areas on toys that are too small to obtain a sample of sufficient size for laboratory analysis. The lead concentrations in more than three-fourths of the paints from Armenia and Kazakhstan exceeded 90 ppm, the limit in the United States, and 600 ppm, the limit in Brazil. The percentages were about one-half as high in Brazil and India. The average concentration in paints purchased in Armenia, 25,000 ppm, is among the highest that has been previously reported, that in Kazakhstan, 15,700 ppm, and India, 16,600, about median. The average concentration in Brazil, 5600 ppm, is among the lowest observed. Paints in Brazil that contained an average of 36,000 ppm before the regulatory limit became effective were below detection (<9 ppm) in samples collected in the current study. The lack of any apparent public monitoring of paint lead content as part of regulatory enforcement makes it difficult to determine whether the regulation was a major factor contributing to the decline in lead use in these paints. Using data from the current study and those available from other studies 24 of 28 paints from major brands in India decreased from high concentrations to 90 ppm or lower. Since lead concentrations in golden yellow paints from these brands were found to decrease to ≤90 ppm, it is possible that all 28 of these paints now contain ≤90 ppm since yellow paints usually have the highest lead concentrations. Other brands in Brazil and India that have been analyzed only one time had lead concentrations up to 59,000 ppm and 134,000 ppm, respectively. Less than one-third of the paints had notations on their labels with information about lead content and these were sometimes inaccurate. The label from one brand indicating “no added lead” contained paint with 134,000 ppm lead, the highest found in this study. Three percent (3 of 98) of the paints with surface lead loading that did not exceed 2 µg/cm{sup 2}, the limit established by the Consumer Product Safety Improvement Act for small areas on toys, contained greater than 90 ppm lead and thus were false negatives. Of the new paint samples that contained ≤600 ppm, 88% contained ≤90 ppm. Of the samples that contained ≤90 ppm, 97% contained ≤45 ppm and 92% contained ≤15 ppm. Based on these data it appears to be technically feasible to manufacture paints containing ≤90 ppm and in many cases to produce paints that have lead concentrations that do not exceed 15 ppm. - Highlights: • Brazilian paints with high lead (avg. 36,000 ppm) contained <9 ppm after regulation. • Lead in major Indian paint brands decreased to low levels by efforts of NGOs/others. • Most paints with lead ≤600 ppm also are ≤90 ppm and many also ≤15 ppm. • At the CPSIA limit of 2 µg Pb/cm{sup 2} for small areas on toys, 3% exceeded 90 ppm lead. • Most paint brands in Armenia and Kazakhstan based/manufactured outside the country.

54 ENVIRONMENTAL SCIENCES↗

A study on phthalate metabolites, bisphenol A and nonylphenol in the urine of Chinese women with unexplained recurrent spontaneous abortion

Humans are widely exposed to phthalates, bisphenol A and nonylphenol owing to the ubiquitous use of these chemicals in consumer products. Increasing attention has been paid to exposure to phthalates, bisphenol A and nonylphenol because of their potential adverse effects on human fertility. A validated method was developed to investigate the three classes of environmental estrogen, mentioned above, in the urine of Chinese women of Nanjing area with unexplained recurrent spontaneous abortion. Solid-phase extraction coupled with ultra performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) was used. In this method, amounts of bisphenol A (BPA), nonylphenol (NP) and four phthalate metabolites, mono-n-butyl phthalate (MBP), mono-isobutyl phthalate (MiBP), mono-benzyl phthalate (MBzP) and mono-2-ethylhexyl phthalate (MEHP), along with their isotope labeled internal standards, were measured using UPLC-MS/MS operated in negative electrospray ionization multiple reaction monitoring mode. The limits of detection were 0.3 ng/mL for the four phthalate metabolites, and 0.5 ng/mL for bisphenol A and nonylphenol. For women with unexplained recurrent spontaneous abortion, the mean concentrations of MBP, MiBP, MBzP, MEHP, BPA and 4-n-NP were 6.52±6.04, 5.51±4.19, 0.53±0.42, 10.12±4.16, 7.13±7.42, 0.41±0.49 ng/mL (mean±SD), respectively. For the control group, the mean concentrations of the corresponding analytes were 4.15±3.57, 2.96±3.30, 0.46±0.49, 6.50±2.81, 4.43±2.23,0.48±0.43 ng/mL (mean±SD), respectively. Levels of MiBP and MEHP were significantly different between the two groups, using Wilcoxon rank sum tests. This method can be applied in epidemiological studies to explore the association between exposure to environmental estrogens and relevant adverse outcomes. - Highlights: • Studied on the exposure level of six analytes in Chinese women with unexplained recurrent spontaneous abortion. • Differences in MEHP and MiBP urine levels were found between case and control groups. • A robust UPLC-MS/MS method was established for detecting phthalate monoesters, bisphenol A and nonylphenol. • An excellent solid-phase extraction method was established for urine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dietary exposure and human risk assessment of phthalate esters based on total diet study in Cambodia

Phthalate esters are used in a wide variety of consumer products, and human exposure to this class of compounds is widespread. Nevertheless, studies on dietary exposure of human to phthalates are limited. In this study, to assess the daily intakes of phthalate esters and the possible adverse health impacts, different food samples were collected from three areas of Cambodia, one of the poorest countries in the world. The ∑phthalate ester concentrations in Kampong Cham, Kratie and Kandal provinces ranged from 0.05 to 2.34 (median 0.88) μg g{sup −1}, 0.19–1.65 (median 0.86) μg g{sup −1} and 0.24–3.05 (median 0.59) μg g{sup −1} wet weight (ww), respectively. Di-2-Ethylhexyl phthalate (DEHP) and diisobutyl phthalate (DiBP) were the predominant compounds among all foodstuffs. The estimated daily intake (EDI) of phthalate esters for the general population in Kampong Cham, Kratie and Kandal was 34.3, 35.6 and 35.8 μg kg{sup −1} bw d{sup −1}, respectively. The dietary daily intake of DEHP, benzylbutyl phthalate (BBP) and di-n-butyl phthalate (DBP) in Kampong Cham, Kratie and Kandal were below the tolerable daily intakes (TDI) imposed by the European Food Safety Authority (EFSA) and reference doses (RfD) imposed by The United States Environmental Protection Agency (USEPA). Rice contributed the greatest quantity of DEHP to the daily intake in Cambodia so may deserve further exploration. To our knowledge, this is the first study to investigate the occurrence and the daily intakes of phthalate esters in Cambodia. - Highlights: • Phthalate esters concentration in daily foodstuffs collected from Cambodia. • Investigate the bioaccessbility of phthalate esters via the foodstuffs consumption. • Health risk evaluation of dietary exposure to phthalate esters.

54 ENVIRONMENTAL SCIENCES↗

U.S. domestic cats as sentinels for perfluoroalkyl substances: Possible linkages with housing, obesity, and disease

Perfluoroalkyl substances (PFAS), such as perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA), are persistent, globally distributed, anthropogenic compounds. The primary source(s) for human exposure are not well understood although within home exposure is likely important since many consumer products have been treated with different PFAS, and people spend much of their lives indoors. Herein, domestic cats were used as sentinels to investigate potential exposure and health linkages. PFAS in serum samples of 72 pet and feral cats, including 11 healthy and 61 with one or more primary disease diagnoses, were quantitated using high-resolution time-of-flight mass spectroscopy. All but one sample had detectable PFAS, with PFOS and perfluorohexane sulfonate (PFHxS) ranging from <LOQ to 121 and <LOQ to 235 ng/mL, respectively. PFAS prevalence and geometric means in cats were very similar to contemporary NHANES reports of human sera in the U. S. population. The highest PFAS serum concentrations detected were in indoor cats due to disproportionately elevated PFHxS levels. Ranked by quartile, contingency testing indicated that total PFAS levels were positively associated with living indoors and with higher body weight and body condition scores. Individual PFAS quartile rankings suggested positive associations with respiratory effusion, thyroid, liver, and possibly chronic kidney disease. Domestic cats appear to be useful sentinels for assessing primary PFAS exposure routes, especially indoor sources of relevance to children. Additional case-control studies in pet cats are warranted to better define the potential health associations observed herein. A “One Health” approach assessing humans, pets, and their common environment may improve our understanding of chronic low-level, largely indoor, PFAS exposure and effects in humans and animals alike. - Highlights: • PFAS serum concentrations were measured in healthy and diseased U. S. domestic cats. • Most abundant were PFOS (range < LOQ to 121) and PFHxS (< LOQ to 235 ng/mL). • PFAS geometric means were very similar to that reported in U.S. human sera by NHANES. • Higher ΣPFAS levels were positively associated with living indoors and with obesity. • Associations with lung, liver, thyroid, or kidney disease may guide future studies.

54 ENVIRONMENTAL SCIENCES↗