Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “completely positive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Exercise with prebreathe appears to increase protection from decompression sickness: Preliminary findings

Extravehicular activity (EVA) from the Space Shuttle involves one hour of prebreath with 100% oxygen, decompression of the entire Shuttle to 10.2 psia for at least 12 hours, and another prebreath for 40 minutes before decompression to the 4.3 psia suit pressure. We are investigating the use of a one-hour prebreathe with 100% oxygen beginning with a ten-minute strenuous exercise period as an alternative for the staged decompression schedule described above. The 10-minute exercise consists of dual-cycle ergometry performed at 75% of the subject's peak oxygen uptake to increase denitrogenation efficiency by increasing ventilation and perfusion. The control exposures were preceded by a one-hour prebreathe with 100% oxygen while resting in a supine position. The twenty-two male subjects were exposed to 4.3 psia for 4 hours while performing light to moderate exercise. Preliminary results from 22 of the planned 26 subjects indicate 76% DCS following supine, resting prebreathe and 38% following prebreathe with exercise. The staged decompression schedule has been shown to result in 23% DCS which is not significantly different from the exercise-enhanced prebreathe results. Prebreathe including exercise appears to be comparable to the protection afforded by the more lengthy staged decompression schedule. Completion of the study later this year will enable planned statistical analysis of the results.

Webb, James T.↗

ROSAT X-Ray Observation of the Second Error Box for SGR 1900+14

The positions of the two error boxes for the soft gamma repeater (SGR) 1900+14 were determined by the "network synthesis" method, which employs observations by the Ulysses gamma-ray burst and CGRO BATSE instruments. The location of the first error box has been observed at optical, infrared, and X-ray wavelengths, resulting in the discovery of a ROSAT X-ray point source and a curious double infrared source. We have recently used the ROSAT HRI to observe the second error box to complete the counterpart search. A total of six X-ray sources were identified within the field of view. None of them falls within the network synthesis error box, and a 3 sigma upper limit to any X-ray counterpart was estimated to be 6.35 x 10(exp -14) ergs/sq cm/s. The closest source is approximately 3 min. away, and has an estimated unabsorbed flux of 1.5 x 10(exp -12) ergs/sq cm/s. Unlike the first error box, there is no supernova remnant near the second error box. The closest one, G43.9+1.6, lies approximately 2.dg6 away. For these reasons, we believe that the first error box is more likely to be the correct one.

Li, P.↗

Is There an Arctic Ozone Hole?

Total ozone observations from the Total Ozone Mapping Spectrometer (TOMS) instruments during March 1997 revealed an extensive region of low column densities in the Arctic region centered near the north pole. Values were below 250 Dobson units for nearly a two week period during this period, and were correlated with the position of the northern lower stratospheric polar vortex. The March 1997 average total ozone column densities were more than 30% lower than the average of column densities observed during the 1979-1982 March period. Both the northern spring seasons of 1998 and 1999 have shown much higher levels of total ozone. In this presentation, we will discuss the causes of the low total ozone values in 1997 and contrast those low values with the higher 1998 and 1999 observations. I will additionally discuss the just completed SOLVE campaign and the March 2000 ozone values.

Newman, Paul A.↗

Role of nitric oxide in adenosine-induced vasodilation in humans

Vasodilation is one of the most prominent effects of adenosine and one of the first to be recognized, but its mechanism of action is not completely understood. In particular, there is conflicting information about the potential contribution of endothelial factors. The purpose of this study was to explore the role of nitric oxide in the vasodilatory effect of adenosine. Forearm blood flow responses to intrabrachial adenosine infusion (125 microg/min) were assessed with venous occlusion plethysmography during intrabrachial infusion of saline or the nitric oxide synthase inhibitor NG-monomethyl-L-arginine (L-NMMA) (12.5 mg/min). Intrabrachial infusions of acetylcholine (50 microg/min) and nitroprusside (3 microg/min) were used as a positive and negative control, respectively. These doses were chosen to produce comparable levels of vasodilation. In a separate study, a second saline infusion was administered instead of L-NMMA to rule out time-related effects. As expected, pretreatment with L-NMMA reduced acetylcholine-induced vasodilation; 50 microg/min acetylcholine increased forearm blood flow by 150+/-43% and 51+/-12% during saline and L-NMMA infusion, respectively (P<.01, n=6). In contrast, L-NMMA did not affect the increase in forearm blood flow produced by 3 microg/min nitroprusside (165+/-30% and 248+/-41% during saline and L-NMMA, respectively) or adenosine (173+/-48% and 270+/-75% during saline and L-NMMA, respectively). On the basis of our observations, we conclude that adenosine-induced vasodilation is not mediated by nitric oxide in the human forearm.

Non-NASA Center↗

Exploration Laboratory Analysis FY13

The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk, which is stated as the Risk of Inability to Adequately Treat an Ill or Injured Crew Member, and ExMC Gap 4.05: Lack of minimally invasive in-flight laboratory capabilities with limited consumables required for diagnosing identified Exploration Medical Conditions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability in future exploration missions. Mission architecture poses constraints on equipment and procedures that will be available to treat evidence-based medical conditions according to the Space Medicine Exploration Medical Conditions List (SMEMCL), and to perform human research studies on the International Space Station (ISS) that are supported by the Human Health and Countermeasures (HHC) element. Since there are significant similarities in the research and medical operational requirements, ELA hardware development has emerged as a joint effort between ExMC and HHC. In 2012, four significant accomplishments were achieved towards the development of exploration laboratory analysis for medical diagnostics. These achievements included (i) the development of high priority analytes for research and medical operations, (ii) the development of Level 1 functional requirements and concept of operations documentation, (iii) the selection and head-to-head competition of in-flight laboratory analysis instrumentation, and (iv) the phase one completion of the Small Business Innovation Research (SBIR) projects under the topic Smart Phone Driven Blood-Based Diagnostics. To utilize resources efficiently, the associated documentation and advanced technologies were integrated into a single ELA plan that encompasses ExMC and HHC development efforts. The requirements and high priority analytes was used in the selection of the four in-flight laboratory analysis performers. Based upon the competition results, a down select process will be performed in the upcoming year. Looking ahead, this unified effort has positioned each element for an in-flight lab analysis demonstration of select diagnostics measurements in the 2015 timeframe.

Krihak, Michael↗

Simulation of a scintillator-based fast ion loss detector for steady-state operation in Wendelstein 7-X (invited)

A quantitative theoretical framework has been created to model neutral beam injection and fast ion losses in the Wendelstein 7-X (W7-X) stellarator, including a novel method to develop synthetic diagnostics for fast ion loss detectors (FILDs) of many types, such as scintillating and Faraday Cup FILDs. This is the first time that this has been done in stellarator geometry with this level of fidelity, providing a way for fast ion losses to be predicted more precisely in future stellarator experiments and in W7-X. Simulations of the signal seen by a Faraday Cup FILD have been completed for multiple W7-X plasmas and show close agreement with the measured signals. This method is now applied to an actively water-cooled, scintillator-based FILD, which is currently in development to measure the fast ion loss distribution in W7-X in greater detail. The design makes use of a double slit to measure energy-and-pitch-angle-resolved losses of both co-going and counter-going fast ions. The diagnostic, which can be inserted to different radial positions, has been designed to withstand steady-state heat fluxes of up to 120 kW/m 2 along with additional transient heat loads of 100 kW/m 2 lasting for up to 20 s at a time. Simulations of W7-X standard magnetic configuration show up to 8 × 10 13 (s –1 cm –2 ) ion fluxes onto the sensor from each neutral beam source and no signal from the counter-going slit. Finally, these simulations will help inform experimental proposals for future W7-X campaigns after installation of this diagnostic.

3D printing↗

Investigation of the utility of ERTS-1 imagery for updating land use and resource data in Guatemala

The author has identified the following significant results. An intensive analysis of the imagery received has been completed and findings are reported. Conclusions are restricted by receipt of only limited amounts of cloud-free coverage of test areas. In most cases the interpretation findings were as anticipated from previous experience with multiband images. Band 7 provides promising indication of some economically important environmental communities. It also permits viewing through thin cirrus cloud layers for features of medium to high contrast. Band 4 provides information of submerged reefs and of movement of suspended sediment bodies in water areas. ERTS-1 bulk images have positional mapping accuracy adequate for representation at 1:1,000,000 scale maps. Cloud cover is a true constraint to useable satellite coverage.

Garcia, L. E.↗

Entrainment and detrainment in a simple cumulus cloud model

A cumulus cloud model, analogous to the mixed-layer models of the planetary boundary layer and the upper ocean, is developed using a single, unitary entrainment process in which the motion of the cloud boundary relative to the mean flow is permitted, produced, and controlled by turbulent processes. An alternate theory to the mixing-length theory of Asai and Kasahara (1967) is proposed which completely removes the strong scale-dependence of the Asai-Kasahara model. The model reintroduces scale-dependence by introducing including the pe5turbation pressure term of the equation of vertical motion. It is shown that the model predicts deeper clouds than the Asai-Kasahara model for a given sounding, due to the entrainment assumption and the effects of the perturbation pressure. Lateral entrainment dominates cloud-top entrainment, although finite-difference errors increase the cloud-top entrainment rate from zero to a positive value in actual situations. The fractional entrainment rate for updrafts is determined to vary only slightly with height and to decrease only slowly as the cloud radius increases, while the fractional detrainment rate for updrafts increases with height.

Randall, D. A.↗

Modeling of convection phenomena in Bridgman-Stockbarger crystal growth

Thermal convection phenomena in a vertically oriented Bridgman-Stockbarger apparatus were modeled by computer simulations for different gravity conditions, ranging from earth conditions to extremely low gravity, approximate space conditions. The modeling results were obtained by the application of a state-of-the art, transient, multi-dimensional, completely densimetrically coupled, discrete-element computational model which was specifically developed for the simulation of flow, temperature, and species concentration conditions in two-phase (solid-liquid) systems. The computational model was applied to the simulation of the flow and the thermal conditions associated with the convection phenomena in a modified Germanium-Silicon charge enclosed in a stationary fused-silica ampoule. The results clearly indicated that the gravitational field strength influences the characteristics of the coherent vortical flow patterns, interface shape and position, maximum melt velocity, and interfacial normal temperature gradient.

Carlson, F. M.↗

On meteor stream spatial structure theory

The classical spatial representation of meteor streams is an elliptical torus with variable cross section. The position of this torus in space is determined by the mean orbit elements that may be obtained directly from observations of individual meteor stream particles when crossed by the Earth. Since the orbits of individual particles of a stream differ from each other, the distance between them on a plane normal to the mean orbit of elliptical torus forms some area, i.e., a cross section. The size and form of these cross sections change with the change of the direction among the mean orbit and are completely defined by the dispersion values of the orbit elements in a stream. An attempt was made to create an analytical method that would permit description of the spatial and time parameters of meteor streams, i.e., the form and size of their cross section, density of incident flux and their variations along the mean orbit and in time. In this case, the stream is considered as a continuous flux rather than a set of individual particles.

Andreev, G. V.↗

Scientific objectives and first results from COMPTEL

The imaging Compton telescope (COMPTEL) is the first imaging telescope in space to explore the MeV gamma ray range. At present it is performing a complete sky survey. In later phases of the mission, selected celestial objects will be studied in more detail. Targets of special interest in the COMPTEL energy range are radio pulsars, X-ray binaries, novae, supernova remnants, molecular clouds, and the interstellar medium within the Milky Way, as well as the nuclei of active galaxies, supernovae, and the diffuse cosmic background radiation in extragalactic space. The first four months of operation demonstrated that COMPTEL basically performs as expected. The Crab is clearly seen at its proper position in the first images of the anticenter region of the Galaxy. The Crab pulsar lightcurve was measured with unprecedented accuracy. The quasar 3C273 was seen for the first time at MeV-energies. Several cosmic bursts within the COMPTEL field of view could be located to an accuracy of about 1 degree. On June 9, 11, and 15, 1991 COMPTEL observed gamma ray (continuum and line) emission from three solar flares. Neutrons were also detected from the June 9 flare. At the present state of analysis, COMPTEL achieves the prelaunch predictions of its sensitivity within a factor of 2. Based on the present performance of COMPTEL, the team is confident that COMPTEL will fulfill its primary mission of surveying and exploring the MeV sky.

Schoenfelder, V.↗

Methodologies to determine forces on bones and muscles of body segments during exercise, employing compact sensors suitable for use in crowded space vehicles

A complete description of an instrumented ergometer system, including the sensors, the data acquisition system, and the methodologies to calculate the kinematic parameters were initially developed at Tulane University. This work was continued by the PI at NASA Johnson Space Center, where a flight ergometer was instrumented and tested during a KC-135 Zero-Gravity flight. The sensors that form part of the system include EMG probes and accelerometers mounted on the subject using the ergometer, load cells to measure pedal forces, and encoders to measure position and orientation of the pedal (foot). Currently, data from the flight test is being analyzed and processed to calculate the kinematic parameters of the individual. The formulation developed during the initial months of the grant will be used for this purpose. The system's components are compact (all sensors are very small). A salient feature of the system and associated methodology to determine the kinematics is that although it uses accelerometers, position is not determined by integration. Position is determined by determining the angle of two frames of reference for which acceleration at one point is known in coordinates of both frames.

Figueroa, Fernando↗

Capillary Movement of Liquid in Granular Beds in Microgravity

A more complete understanding of the dynamics of capillary flow through an g unsaturated porous medium would be useful for a number of space and terrestrial applications. One such application involves the development of an effective water and nutrient delivery system for the growth of plants in space. An experiment was conducted on the Mir Space Station that used an experimental cuvette called "Capillary Test Bed". An objective of this experiment was to compare fluid migration in the "Capillary Test Bed" under terrestrial laboratory simulated microgravity conditions by positioning the cuvette such that the hydrostatic force is negated and on Mir at microgravity conditions. Difference in fluid migration in the cuvette were observed. Based on these observations, improvements in the design of the cuvette are under-way that should allow for collection of more precise data in future flight experiments. The results of the MIR experiment and modifications being made to the cuvette for improved data collection will be discussed.

Yendeler, Boris S.↗

Global Monthly and Daily Precipitation Analysis for the Global Precipitation Climatology Project (GPCP): Global and Regional Variations and Trends

The 22 year, monthly, globally complete precipitation analysis of the World Climate Research Program's (WCRP/GEWEX) Global Precipitation Climatology Project (GPCP) and the four year (1997-present) daily GPCP analysis are described in terms of the data sets and analysis techniques used in their preparation. These analyses are then used to study global and regional variations and trends during the 22 years and the shorter-time scale events that constitute those variations. The GPCP monthly data set shows no significant trend in global precipitation over the twenty years, unlike the positive trend in global surface temperatures over the past century. The global trend analysis must be interpreted carefully, however, because the inhomogeneity of the data set makes detecting a small signal very difficult, especially over this relatively short period. The relation of global (and tropical) total precipitation and ENSO (El Nino and Southern Oscillation) events is quantified with no significant signal when land and ocean are combined. In terms of regional trends 1979 to 2000 the tropics have a distribution of regional rainfall trends that has an ENSO-like pattern with features of both the El Nino and La Nina. This feature is related to a possible trend in the frequency of ENSO events (either El Nino or La Nina) over the past 20 years. Monthly anomalies of precipitation are related to ENSO variations with clear signals extending into middle and high latitudes of both hemispheres. The El Nino and La Nina mean anomalies are near mirror images of each other and when combined produce an ENSO signal with significant spatial continuity over large distances. A number of the features are shown to extend into high latitudes. Positive anomalies extend in the Southern Hemisphere from the Pacific southeastward across Chile and Argentina into the south Atlantic Ocean. In the Northern Hemisphere the counterpart feature extends across the southern U.S. and Atlantic Ocean into Europe. In the Southern Hemisphere an anomaly feature is shown to spiral into the Antarctica land mass. The extremes of ENSO-related anomalies are also examined and indicate that globally, during both El Nino and La Nina, more extremes of precipitation (both wet and dry) occur than during the "neutral" regime, with the El Nino regime showing larger magnitudes. The distribution is different for the globe as a whole and when the area is restricted to just land. The recent (1998-present) Tropical Rainfall Measuring Mission (TRMM) observations are also compared with the GPCP analyses and are evaluated with regard to improving the long-term GPCP data set.

Adler, Robert F.↗

Video Analysis for Surveillance of Spacecraft Parachute Systems

The Commercial Crew Program (CCP) has established a surveillance methodology to ensure the reliability of spacecraft parachute systems. The implemented methodology relies on an interconnected framework consisting of imagery analysis, hardware inspections, and vehicle data analysis. Imagery analysis serves as a foundation for these core activities which provide a robust approach to the surveillance of spacecraft parachute systems. As the surveillance framework has been developed, the role of imagery has become more prominent, and therefore imagery requirements have changed. To complete photogrammetric analysis, careful consideration must be made to the role of imagery, required data, imagery requirements, the analysis process, and mission planning. The role of imagery will drive the required data, which will in turn drive imagery requirements. Imagery requirements are likely to drive mission planning through consideration to camera selection and placement. If onboard imagery is required, the camera and data system must be implemented prior to launch. If external imagery is required, the photography package must be implemented such that it can be positioned for a return and free of potential debris fields. For these reasons, an integrated approach must be used to build an imagery package around the required analysis with careful coordination with mission planners.

parachutes↗

Video Analysis for Surveillance of Spacecraft Parachute Systems

The Commercial Crew Program (CCP) has established a surveillance methodology to ensure the reliability of spacecraft parachute systems. The implemented methodology relies on an interconnected framework consisting of imagery analysis, hardware inspections, and vehicle data analysis. Imagery analysis serves as a foundation for these core activities which provide a robust approach to the surveillance of spacecraft parachute systems. As the surveillance framework has been developed, the role of imagery has become more prominent, and therefore imagery requirements have changed. To complete photogrammetric analysis, careful consideration must be made to the role of imagery, required data, imagery requirements, the analysis process, and mission planning. The role of imagery will drive the required data, which will in turn drive imagery requirements. Imagery requirements are likely to drive mission planning through consideration to camera selection and placement. If onboard imagery is required, the camera and data system must be implemented prior to launch. If external imagery is required, the photography package must be implemented such that it can be positioned for a return and free of potential debris fields. For these reasons, an integrated approach must be used to build an imagery package around the required analysis with careful coordination with mission planners.

parachutes↗

Dark Energy Survey: A 2.1% measurement of the angular baryonic acoustic oscillation scale at redshift z eff = 0.85 from the final dataset

Here, we present the angular diameter distance measurement obtained with the baryonic acoustic oscillation (BAO) feature from galaxy clustering in the completed Dark Energy Survey, consisting of six years (Y6) of observations. We use the Y6 BAO galaxy sample, optimized for BAO science in the redshift range 0.6 < z <1.2, with an effective redshift at z eff = 0.85 and split into six tomographic bins. The sample has nearly 16 million galaxies over 4,273 square degrees. Our consensus measurement constrains the ratio of the angular distance to sound horizon scale to D M ⁡(z eff )/r d = 19.51 ± 0.41 (at 68.3% confidence interval), resulting from comparing the BAO position in our data to that predicted by planck Λ⁢CDM via the BAO shift parameter α =(D M /r d )/(D M /r d ) PLANCK . To achieve this, the BAO shift is measured with three different methods, angular correlation function (ACF), angular power spectrum (APS), and projected correlation function (PCF), obtaining α = 0.952 ± 0.023, 0.962 ± 0.022, and 0.955 ± 0.020, respectively, which we combine to α = 0.957 ± 0.020, including systematic errors. When compared with the Λ⁢CDM model that best fits planck data, this measurement is found to be 4.3% and 2.1⁢σ below the angular BAO scale predicted. To date, it represents the most precise angular BAO measurement at z > 0.75 from any survey and the most precise measurement at any redshift from photometric surveys. The analysis was performed blinded to the BAO position, and it is shown to be robust against analysis choices, data removal, redshift calibrations, and observational systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗