Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “code review”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Analysis of the Argonne distance tabletop exercise method.

The purpose of this report is to summarize and evaluate the Argonne Distance Tabletop Exercise (DISTEX) method. DISTEX is intended to facilitate multi-organization, multi-objective tabletop emergency response exercises that permit players to participate from their own facility's incident command center. This report is based on experience during its first use during the FluNami 2007 exercise, which took place from September 19-October 17, 2007. FluNami 2007 exercised the response of local public health officials and hospitals to a hypothetical pandemic flu outbreak. The underlying purpose of the DISTEX method is to make tabletop exercising more effective and more convenient for playing organizations. It combines elements of traditional tabletop exercising, such as scenario discussions and scenario injects, with distance learning technologies. This distance-learning approach also allows playing organizations to include a broader range of staff in the exercise. An average of 81.25 persons participated in each weekly webcast session from all playing organizations combined. The DISTEX method required development of several components. The exercise objectives were based on the U.S. Department of Homeland Security's Target Capabilities List. The ten playing organizations included four public health departments and six hospitals in the Chicago area. An extent-of-play agreement identified the objectives applicable to each organization. A scenario was developed to drive the exercise over its five-week life. Weekly problem-solving task sets were designed to address objectives that could not be addressed fully during webcast sessions, as well as to involve additional playing organization staff. Injects were developed to drive play between webcast sessions, and, in some cases, featured mock media stories based in part on player actions as identified from the problem-solving tasks. The weekly 90-minute webcast sessions were discussions among the playing organizations that were moderated by a highly-qualified public health physician, who reviewed key scenario developments and player actions, as well as solicited input from each playing organization. The exercise control structure included trusted agents who oversaw exercise planning, playing organization points of contact to ensure exercise coordination, and exercise controller/evaluators to initiate and oversee exercise play. A password-protected exercise website was designed for FluNami 2007 to serve as a compartmentalized central information source, and for transmitting exercise documents. During the course of FluNami 2007, feedback on its quality was collected from players and controller/evaluators. Player feedback was requested at the conclusion of each webcast, upon completion of each problem-solving task, and on October 17, 2007, after the final webcast session had ended. The overall average score given to FluNami 2008 by the responding players was 3.9 on a five-point scale. In addition, suggestions for improving the process were provided by Argonne controller/evaluators after the exercise concluded. A series of recommendations was developed based on feedback from the players and controller/evaluators. These included improvements to the exercise scope and objectives, the problem-solving tasks, the scenarios, exercise control, the webcast sessions, the exercise website, and the player feedback process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The Appropriateness of Renal Angioplasty. The ANPARIA Software: A Multidisciplinary Expert Panel Approach

Percutaneous transluminal renal angioplasty (PTRA) is an invasive technique that is costly and involves the risk of complications and renal failure. The ability of PTRA to reduce the administration of antihypertensive drugs has been demonstrated. A potentially greater benefit, which nevertheless remains to be proven, is the deferral of the need for chronic dialysis. The aim of the study (ANPARIA) was to assess the appropriateness of PTRA to impact on the evolution of renal function. A standardized expert panel method was used to assess the appropriateness of medical treatment alone or medical treatment with revascularization in various clinical situations. The choice of revascularization by either PTRA or surgery was examined for each clinical situation. Analysis was based on a detailed literature review and on systematically elicited expert opinion, which were obtained during a two-round modified Delphi process. The study provides detailed responses on the appropriateness of PTRA for 1848 distinct clinical scenarios. Depending on the major clinical presentation, appropriateness of revascularization varied from 32% to 75% for individual scenarios (overal 48%). Uncertainty as to revascularization was 41% overall. When revascularization was appropriate, PTRA was favored over surgery in 94% of the scenarios, except in certain cases of aortic atheroma where sugery was the preferred choice. Kidney size >7 cm, absence of coexisting disease, acute renal failure, a high degree of stenosis ({>=}70%), and absence of multiple arteries were identified as predictive variables of favorable appropriateness ratings. Situations such as cardiac failure with pulmonary edema or acute thrombosis of the renal artery were defined as indications for PTRA. This study identified clinical situations in which PTRA or surgery are appropriate for renal artery disease. We built a decision tree which can be used via Internet: the ANPARIA software (http://www.chu-clermontferrand.fr/anpariahttp://www.chu-clermontferrand.fr/anparia/). In numerous clinical situations uncertainty remains as to whether PTRA prevents deterioration of renal function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review of Activities using the Pulsed Neutron Facility and 2.5-GeV Electron Linac at Pohang Accelerator Laboratory

We report on activities using a pulsed neutron facility consisting of an electron linear accelerator, a water-cooled Ta target with a water moderator, and a 12 m time-of-flight path. It is possible to measure neutron total cross sections in the neutron energy range from 0.01 eV to a few hundred eV by using the neutron time-of-flight method; photo-neutron cross sections can also measure by using the bremsstrahlung from the electron linac. A {sup 6}LiZnS(Ag) glass scintillator was used as a neutron detector. The neutron flight path from the water-cooled Ta target to the neutron detector was 12.1 m. In this paper, we report total cross sections of Nb and also resonance parameters obtained using the SAMMY fitting program. The present results are compared with the previous experimental results and the evaluated data in ENDF/B-VII. We also report on the mass-yield distribution of fission products in the 2.5-GeV bremsstrahlung-induced fission of {sup nat}Pb and {sup 209}Bi measured at the 2.5-GeV electron linac using a recoil catcher and an off-line {gamma}-ray spectrometric technique.

43 PARTICLE ACCELERATORS↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 130: Storage Tanks, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 130, Storage Tanks, identified in the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended February 2008). Corrective Action Unit 130 consists of the seven following corrective action sites (CASs) located in Areas 1, 7, 10, 20, 22, and 23 of the Nevada Test Site: • 01-02-01, Underground Storage Tank • 07-02-01, Underground Storage Tanks • 10-02-01, Underground Storage Tank • 20-02-03, Underground Storage Tank • 20-99-05, Tar Residue • 22-02-02, Buried UST Piping • 23-02-07, Underground Storage Tank This plan provides the methodology for field activities needed to gather the necessary information for closing each CAS. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 130 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible recommendation that no further corrective action is necessary. This will be presented in a Closure Report that will be prepared and submitted to the Nevada Division of Environmental Protection (NDEP) for review and approval. The sites will be investigated based on the data quality objectives (DQOs) finalized on April 3, 2008, by representatives of NDEP; U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each CAS in CAU 130. The DQO process developed for this CAU identified the following expected closure options: (1) investigation and confirmation that no contamination exists above the final action levels, leading to a no further action declaration; (2) characterization of the nature and extent of contamination, leading to closure in place with use restrictions; or (3) clean closure by remediation and verification. The following text summarizes the SAFER activities that will support the closure of CAU 130: • Perform site preparation activities (e.g., utilities clearances, geophysical surveys). • Move or remove and dispose of debris at various CASs, as required. • Collect environmental samples from designated target populations (e.g., stained soil) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish no further action as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. • If a COC is present at a CAS, either: - Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Obtain consensus from NDEP that the preferred closure option is sufficient to protect human health and the environment. • Close the underground storage tank(s) and their contents, if any, in accordance with Nevada Administrative Code regulations. • Remove the lead brick(s) found at any CAS in accordance with the Resource Conservation and Recovery Act.

54 ENVIRONMENTAL SCIENCES↗

Reassessing Double-Ended Guillotine Break Requirements: Evidence-Based Analysis of Regulatory Assumptions After Five Decades of Nuclear Operation

After five decades of nuclear power operation encompassing more than 20,000 reactor-years across 35 countries and 647 reactors, zero double-ended guillotine breaks (DEGBs) have been documented in commercial reactor coolant systems—despite DEGB being the fundamental design-basis assumption driving Emergency Core Cooling System (ECCS) sizing, structural protection requirements, and containment design specifications. This report examines the basis for DEGB requirements in nuclear power plant design. The DEGB postulate assumes the instantaneous, complete circumferential severance of the largest diameter pipes in reactor coolant systems, driving major design requirements under 10 Code of Federal Regulations 50.46, General Design Criterion 4 and containment design specifications. The United States (4,880 reactor-years) and France (2,505 reactor-years) contribute the largest operational datasets. Probabilistic assessments estimate direct DEGB occurrence probabilities with extremely low event frequencies, far below the 10-5/reactor-year thresholds typically used to define non-credible events in nuclear-safety analyses; i.e., events with probability this low fall into beyond-design-basis events. Current material-science knowledge demonstrates that the ductile steel materials used in nuclear piping systems exhibit stable crack-growth behavior fundamentally incompatible with instantaneous severance. International regulatory experience, particularly Germany’s comprehensive break-preclusion implementation, and successful leak-before-break (LBB) applications in almost all of U.S. pressurized water reactor units validate that alternatives can maintain safety performance while reducing economic burden. Current DEGB protection systems impose estimated lifetime costs of hundreds of millions of dollars per unit, over the life of a plant across the nuclear industry (including ongoing costs), representing substantial resource allocation toward scenarios with extremely low probability. Although this report acknowledges uncertainties regarding long-term aging effects, potential synergistic degradation mechanisms, and site-specific seismic considerations that warrant continued evaluation as regulatory policy evolves, there remains no documented evidence that a DEGB has occurred as a consequence of the conditions or mechanisms described in this report. This report acknowledges the Nuclear Regulatory Commission’s (NRC’s) recent efforts—outlined in the draft Interim Staff Guidance (ISG) NRC-DSS-ISG-2025-XX (“Treatment of Certain Loss-of-Coolant Accident Locations as Beyond-Design-Basis Accidents Draft Interim Staff Guidance”)—to reduce overly conservative requirements for large-break loss of coolant accidents through technical justifications and exemptions. However, extensive operating experience and validated methodologies—such as LBB and in-service inspection programs—demonstrate that the probability of a DEGB in reactor coolant-loop piping is extremely low, even under seismic conditions. The authors and reviewers of this report recommend that DEGB be removed as a design-basis event through formal rulemaking, rather than case-by-case exemptions, to better reflect credible failure modes, align with current data, and align with modern, risk-informed safety analysis.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Analyst - A Device for Continuous Repeating Real-Time Assay of HPGe, CZT, or Scintillation Gamma Spectra - 18574

There are many situations where a continuous repeating series of quantitative gamma spectral assays is desirable. These include measurements of fluid going through a pipe, of items on a conveyor passing under a detector, a detector aimed at the ground on a moving platform, or a detector in free air as a plume of radioactivity drifts by. While Canberra and many others have built and deployed many of these devices, they have all been custom built for that particular application, and rather expensive. The Data Analyst [DA] is a general purpose device that is designed to fulfill many of these applications without modification, but can be fairly-easily modified if needed. The DA is a small [12 x 18 x 5 cm], low-power [3 W] box that accepts the input from external MCAs, controls the acquisition cycle, analyzes the results, and transmits them to the outside world when needed. The detector-MCAs supported are HPGe with Lynx MCA, NaI or CeBr or LaBr with Osprey MCA, and CZT or CsI with internal MCAs. The DA internal software used for analysis is the full standard Genie analysis software, which is very widely used and well accepted in the industry. This allows exported spectral files to be reviewed and confirmed by Experts, and reanalyzed if needed. The DA hardware is totally autonomous. As soon as power is applied, it starts the pre-programmed sequences of acquisition and analysis. Multiple analysis sequences [called Workflows] can be in operation simultaneously, e.g. with different count times and different nuclide libraries. Only the detector with MCA, and the DA are required in the field. A PC can be connected to the DA locally or remotely via WiFi, USB, or Ethernet. The PC is needed to setup the DA, and to readout the results. The DA also supports [with application-specific programming] external Inputs/Outputs either for recording with the analysis results or for use in the computation of the result, e.g. temperature, flow rate, pressure, ... ]. The DA also has an internal GPS receiver with external antenna. Applications of the DA that are discussed include stack gas effluent activity where a portion of the effluent stream was extracted to flow through a shield with a HPGe detector and Lynx MCA, and measurement of reactor coolant activity where a shielded CZT detector and MCA were aimed at various sections of reactor primary coolant during a maintenance outage. Potential other applications are also described. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lawrence Livermore National Laboratory Emergency Response Capability Baseline Needs Assessment Requirement Document

This revision of the LLNL Fire Protection Baseline Needs Assessment (BNA) was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by Martin Gresho, Sandia/CA Fire Marshal. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only address emergency response. The original LLNL BNA was created on April 23, 1997 as a means of collecting all requirements concerning emergency response capabilities at LLNL (including response to emergencies at Sandia/CA) into one BNA document. The original BNA documented the basis for emergency response, emergency personnel staffing, and emergency response equipment over the years. The BNA has been updated and reissued five times since in 1998, 1999, 2000, 2002, and 2004. A significant format change was performed in the 2004 update of the BNA in that it was 'zero based.' Starting with the requirement documents, the 2004 BNA evaluated the requirements, and determined minimum needs without regard to previous evaluations. This 2010 update maintains the same basic format and requirements as the 2004 BNA. In this 2010 BNA, as in the previous BNA, the document has been intentionally divided into two separate documents - the needs assessment (1) and the compliance assessment (2). The needs assessment will be referred to as the BNA and the compliance assessment will be referred to as the BNA Compliance Assessment. The primary driver for separation is that the needs assessment identifies the detailed applicable regulations (primarily NFPA Standards) for emergency response capabilities based on the hazards present at LLNL and Sandia/CA and the geographical location of the facilities. The needs assessment also identifies areas where the modification of the requirements in the applicable NFPA standards is appropriate, due to the improved fire protection provided, the remote location and low population density of some the facilities. As such, the needs assessment contains equivalencies to the applicable requirements. The compliance assessment contains no such equivalencies and simply assesses the existing emergency response resources to the requirements of the BNA and can be updated as compliance changes independent of the BNA update schedule. There are numerous NFPA codes and standards and other requirements and guidance documents that address the subject of emergency response. These requirements documents are not always well coordinated and may contain duplicative or conflicting requirements or even coverage gaps. Left unaddressed, this regulatory situation results in frequent interpretation of requirements documents. Different interpretations can then lead to inconsistent implementation. This BNA addresses this situation by compiling applicable requirements from all identified sources (see Section 5) and analyzing them collectively to address conflict and overlap as applicable to the hazards presented by the LLNL and Sandia/CA sites (see Section 7). The BNA also generates requirements when needed to fill any identified gaps in regulatory coverage. Finally, the BNA produces a customized simple set of requirements, appropriate for the DOE protection goals, such as those defined in DOE O 420.1B, the hazard level, the population density, the topography, and the site layout at LLNL and Sandia/CA that will be used as the baseline requirements set - the 'baseline needs' - for emergency response at LLNL and Sandia/CA. A template approach is utilized to accomplish this evaluation for each of the nine topical areas that comprise the baseline needs for emergency response. The basis for conclusions reached in determining the baseline needs for each of the topical areas is presented in Sections 7.1 through 7.9. This BNA identifies only mandatory requirements and establishes the minimum performance criteria. The minimum performance criteria may not be the level of performance desired Lawrence Livermore National Laboratory or Sandia/CA. Performance at levels greater than those established by this document will provide a higher level of fire safety, fire protection, or loss control and is encouraged. In Section 7, Determination of Baseline Needs, a standard template was used to describe the process used that involves separating basic emergency response needs into nine separate services. Each service being evaluated contains a determination of minimum requirements, an analysis of the requirements, a statement of minimum performance, and finally a summary of the minimum performance. The requirement documents, listed in Section 5, are those laws, regulations, DOE Directives, contractual obligations, or LLNL policies that establish service levels. The determination of minimum requirements section explains the rationale or method used to determine the minimum requirements.

99 GENERAL AND MISCELLANEOUS↗

Radiative Heat Transport and Optical Characterization of High Temperature Molten Salts

The goal of this project was to advance the field of molten fluoride radiative heat transfer (RHT), through optical property measurements, heat transfer loop construction and operation, and computational fluid dynamics simulations. The following outcomes have been accomplished. A comprehensive review has been conducted to compile all available RHT-relevant optical absorption data for molten fluorides. The various measurement methods have also been compiled and critiqued. Thermal emission measurement methods have been refined and documented. A unique thermal emissivity measurement facility has been constructed and used to measure the emissivity of flowing FLiBe-exposed SS316 samples. A slight increase has been observed in the emissivity compared to unexposed SS316. A dual reflectance-emission setup was partially demonstrated for the purpose of molten fluoride absorption measurement. Preliminary infrared edge data for FLiNaK was obtained. A visible near-infrared (NIR) measurement setup has been constructed and will be used to measure absorption of corrosion products in FLiBe. A new multi-band thermal radiation method using blackbody-weighted spectral bands for the absorption-coefficient was deployed to investigate the thermal performance of the UW Natural Circulation FLiBe Loop under various power levels and operating conditions. The results showed an increasing and decreasing trend in the overall heat transfer with optical thickness with a maximum at optical thickness τ D ≈Ο(1). A forced convection FLiBe loop was constructed for the purpose of studying corrosion and thermal hydraulic phenomena. A vertical cantilever pump is used to achieve up to 5 gpm and 5 m/s flow velocity in hot and cold test sections. A methodology has been established for modeling radiative heat transfer (RHT) in molten salt coolants for the purpose of quantifying the contribution of thermal radiation in conditions relevant to FHR or MSR systems. The comparison between the results obtained for forced and mixed convection showed that in the studied ranges of optical thickness, the maximum effect of RHT on overall heat transfer was 60% improvement observed at z/D = 250 for forced convection; whereas for mixed convection, that value was higher at 170% observed at z/D = 30. The highest effect of RHT on the overall energy distribution was observed at τ D ≈3.4. Negligible effect (<20%) was observed above τ D =18 and below τ D ≈0.002. A CFD code-to-code comparison was conducted using COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT, for a forced and mixed convection laminar flow for a grey medium in a vertical heated using both COMSOL Multiphysics at UW-Madison and STAR-CCM at MIT. The relative error was the largest at τ D =40 for the radiative heat flux, bulk temperature, and Nusselt number. On the other hand, the relative error was the least at τ D =0.002 for the conductive heat flux, bulk temperature, and Nusselt number.

Anderson, Mark↗

Numerical Modelling of Radionuclide Migration in the Context of a Near-Surface LILW Disposal Facility - 18618

The reference solution for the management of low and intermediate level short-lived waste (LILW) in France consists in their emplacement in concrete vaults built at the near-surface. The corresponding disposal facility under operation by the French waste management organization (Andra), is located in North-eastern France and planned to be closed in 2060. The safety case developed by Andra has to show the evidence that, amongst other aspects, the radionuclide transfer through the confinement barriers will occur in such a way that the human and environmental exposure will be as low as reasonably achievable (ALARA) and in accordance with the dose constraints. For this purpose, modelling is used to integrate uncertainties about the characteristics of concrete components, waste and water table and their evolution in time and space. At last, modelling is finally used to investigate the radiological impact of specific scenarios in which the failure of safety barriers occurs. In the frame of its technical review of the safety assessment, the French Institute for Radiological Protection and Nuclear Safety (IRSN) also performs such kind of numerical modelling of radionuclide fate from the waste to the hydrogeological outlets, in order to check whether the assessment performed by Andra takes into account sufficiently conservative assumptions. The present work aims to evaluate the role of components of the vaults on radionuclide transport during the post-closure period over a few thousand years. For this purpose, IRSN carries out numerical calculations with MELODIE software, which simulates water flow and transport of species, in order to simulate radionuclide migration from waste packages emplaced in a concrete vault to the surrounding groundwater. The developed transport model focuses on 3-H radionuclide and integrates Andra's main assumptions (release model from the waste packages, chemical and hydraulic properties of the vault components, shrinkage and cracks in concrete components). An adaptive mesh method, based on an a posteriori error estimator, was used to model the cracks and the consideration of a strong heterogeneity in the hydraulic and transport parameters values in the different components of the model. This method shows an improvement of results of about 40 times, whereas the mesh size was increased by only 2%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Cementitious Barriers Partnership Experimental Programs and Software Advancing DOE’s Waste Disposal/Tank Closure Efforts – 15436

The U.S. Department of Energy Environmental Management (DOE-EM) Office of Tank Waste Management-sponsored Cementitious Barriers Partnership (CBP) is chartered with providing the technical basis for implementing cement-based waste forms and radioactive waste containment structures for long-term disposal. DOE needs in this area include the following to support progress in final treatment and disposal of legacy waste and closure of High-Level Waste (HLW) tanks in the DOE complex: long-term performance predictions, flow sheet development and flow sheet enhancements, and conceptual designs for new disposal facilities. The DOE-EM Cementitious Barriers Partnership is producing software and experimental programs resulting in new methods and data needed for end-users involved with environmental cleanup and waste disposal. Both the modeling tools and the experimental data have already benefited the DOE sites in the areas of performance assessments by increasing confidence backed up with modeling support, leaching methods, and transport properties developed for actual DOE materials. In 2014, the CBP Partnership released the CBP Software Toolbox –“Version 2.0” which provides concrete degradation models for 1) sulfate attack, 2) carbonation, and 3) chloride initiated rebar corrosion, and includes constituent leaching. These models are applicable and can be used by both DOE and the Nuclear Regulatory Commission (NRC) for service life and long-term performance evaluations and predictions of nuclear and radioactive waste containment structures across the DOE complex, including future SRS Saltstone and HLW tank performance assessments and special analyses, Hanford site HLW tank closure projects and other projects in which cementitious barriers are required, the Advanced Simulation Capability for Environmental Management (ASCEM) project which requires source terms from cementitious containment structures as input to their flow simulations, regulatory reviews of DOE performance assessments, and Nuclear Regulatory Commission reviews of commercial nuclear power plant (NPP) structures which are part of the overall US Energy Security program to extend the service life of NPPs. In addition, the CBP experimental programs have had a significant impact on the DOE complex by providing specific data unique to DOE sodium salt wastes at Hanford and SRS which are not readily available in the literature. Two recent experimental programs on cementitious phase characterization and on technetium (Tc) mobility have provided significant conclusions as follows: recent mineralogy characterization discussed in this paper illustrates that sodium salt waste form matrices are somewhat similar to but not the same as those found in blended cement matrices which to date have been used in long-term thermodynamic modeling and contaminant sequestration as a first approximation. Utilizing the CBP generated data in long-term performance predictions provides for a more defensible technical basis in performance evaluations. In addition, recent experimental studies related to technetium mobility indicate that conventional leaching protocols may not be conservative for direct disposal of Tc-containing waste forms in vadose zone environments. These results have the potential to influence the current Hanford supplemental waste treatment flow sheet and disposal conceptual design.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The cementitious barriers partnership experimental programs and software advancing DOE's waste disposal/tank closure efforts - 15436

The U.S. Department of Energy Environmental Management (DOE-EM) Office of Tank Waste Management sponsored Cementitious Barriers Partnership (CBP) is chartered with providing the technical basis for implementing cement-based waste forms and radioactive waste containment structures for long-term disposal. DOE needs in this area include the following to support progress in final treatment and disposal of legacy waste and closure of High-Level Waste (HLW) tanks in the DOE complex: - Long-term performance predictions and - Flow sheet development and flow sheet enhancements - Conceptual designs for new disposal facilities The DOE-EM Cementitious Barriers Partnership is producing software and experimental programs resulting in new methods and data needed for end-users involved with environmental cleanup and waste disposal. Both the modeling tools and the experimental data have already benefited the DOE sites in the areas of performance assessments by increasing confidence backed up with modeling support, leaching methods, and transport properties developed for actual DOE materials. In 2014, the CBP Partnership released the CBP Software Toolbox - 'Version 2.0' which provides concrete degradation models for: 1) sulfate attack, 2) carbonation, 3) chloride initiated rebar corrosion, and includes constituent leaching. These models are applicable and can be used by both DOE and the Nuclear Regulatory Commission (NRC) for service life and long-term performance evaluations and predictions of nuclear and radioactive waste containment structures across the DOE complex (Figure 1) including Future SRS salt-stone and HLW tank performance assessments and special analyses - Hanford site HLW tank closure projects and other projects in which cementitious barriers are required - The Advanced Simulation Capability for Environmental Management (ASCEM) project which requires source terms from cementitious containment structures as input to their flow simulations - Regulatory reviews of DOE performance assessments - Nuclear Regulatory Commission reviews of commercial nuclear power plant (NPP) structures which are part of the overall US Energy Security program to extend the service life of NPPs In addition, the CBP experimental programs have had a significant impact on the DOE complex by providing specific data unique to DOE sodium salt wastes at Hanford and SRS which are not readily available in the literature. Two recent experimental programs on cementitious phase characterization and on technetium (Tc) mobility have provided significant conclusions as summarized below: Recent mineralogy characterization discussed in this paper illustrates that sodium salt waste form matrices are somewhat similar to but not the same as those found in blended cement matrices which to date have been used in long-term thermodynamic modeling and contaminant sequestration as a first approximation. Utilizing the CBP generated data in long-term performance predictions provides for a more defensible technical basis in performance evaluations. - In addition, recent experimental studies related to technetium mobility indicate that conventional leaching protocols may not be conservative for direct disposal of Tc- containing waste forms in vadose zone environments. These results have the potential to influence the current Hanford supplemental waste treatment flow sheet and disposal conceptual design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field and Model Data Associated with the Manuscript “Drivers of Streamflow Intermittency in Humid Regions: 2. Evaluating Controls on Flow Persistence in an Urbanized Catchment”

This package contains field data, modeling files, and scripts supporting the investigation of the drivers of streamflow intermittency in an urbanized catchment. It includes the field data collected from electrical resistivity tomography (ERT) surveys, distributed temperature sensing (DTS), continuous self-potential (SP) monitoring, groundwater and stilling well. In addition, it contains the data and results of the coupled water- and electrical-flow model developed using the COMSOL Multiphysics and Advanced Terrestrial Simulator (ATS), as well as software files and Jupyter notebooks used to process the data and generate figures in the manuscript submitted for peer review. The data archive is organized in the following directories: 1) Climate Includes hourly precipitation and daily evapotranspiration time series (2024 – 2025) provided as CSV files, alongside a text file detailing dataset units. 2) Coupled_model Field_Application subfolder contains the ATS XML input scripts, data files, output data for the SP site. It also contains the Jupyter notebook (Plot_final_calib.ipynb) to visualize the results of the modeled SP, stream-groundwater exchange and moisture content. The flow model simulation is executed using the ATS XML scripts and the included Python script (generate_data_set.py) to convert ATS output to COMSOL-ready input. COMSOL Multiphysics template (.m can only be used with COMSOL with MATLAB) is executed using the ATS output data to simulate the potential field. 3) Discharge Includes the electrical conductivity (EC) time series (provided as CSV files) from salt slug injections. It also includes the Jupyter notebook (Discharge_process.ipynyb) used to estimate discharge. All discharge measurements collated into rating_curve_processed.csv 4) DTS Contains collated DTS data including raw Stokes and anti-Stokes measurement (provided as .h5 file). It also includes DTS processing.ipynb, a Jupyter notebook for calibrating the DTS data using dts_calibration Python package. cooler_calibration.csv is the DTS calibration CSV used in the calibration sequence. 5) ERT Contains raw resistivity data (provided as CSV files), spatial location of each of the electrodes (provided as CSV files), and files used for the resistivity inversion. 6) Slug_test Includes the slug test data at all the groundwater wells provided as CSV files, as well as the Jupyter notebook (Slug_test.ipynb) for calculating hydraulic conductivity. 7) SP Contains the SP data collected in field at the SP sites (provided as CSV files). 8) Well_data Contains two subfolders: 1) Raw, which provides unprocessed pressure, electrical conductivity and temperature timeseries downloaded from the loggers in all the groundwater and stilling wells, and 2) Processed, which contains sorted, QA/QC timeseries data for each well. The data archive also contains data_process.ipynb, a Jupyter notebook used for field data analysis and generating figures (plotting well, SP, climate, and discharge data, as well as calculating head gradient at sites with nested groundwater wells). Note: Code files (.ipynb, .py, .xml) can be opened in any standard code editor, .exo file can be viewed using Paraview, .h5 files can be opened using HDFView software and h5py Python package, and .resipy file can be opened with the open-source ResIPy software.

ATS↗

Innovative Advanced Hydrogen Mobile Fueler (Final Technical Report)

The US Department of Energy (DOE) funded a project to design, develop, deploy and analyze the economic viability of an innovative Advanced Hydrogen Mobile Fueler (AHMF). As part of the design activity the project team defined specifications based upon vehicle requirements and compliance with specific fueling performance criteria. The AHMF was originally designed to fuel 10-20 fuel cell vehicles (FCV) per day, consistent with the requirements of the H70 fueling category. The AHMF is able to operate without remote power connections, is modular for easy transport and deployment, and can provide expanded daily capacity and multi-day operations using delivered gaseous hydrogen. Toward the end of the project, due to request from the hydrogen industry and some necessary modifications of the AHMF, the system is now modified to fuel heavy duty vehicles. The project was conducted over two primary phases, each including several key tasks, subtasks, and project milestones. Phase 1 involved the design, development, and construction of the AHMF, moving from a conceptual design through to completion of assembly and testing. In addition to reviewing several different approaches, the team chose to take a conventional station design and modify it for mobile fueling. There were several innovative components included in the design. The high pressure storage was the first to achieve a US Department of Energy (DOE) Special Permit (SP 20391) to transport high pressure hydrogen (95 MPa) in a composite cylinder. The second novel system was a liquid nitrogen (LIN) cooling system with a compact heat exchanger. Without this change, the cooling system would not be able to fit into the AHMF. Phase 2 demonstrated the AHMF by fueling fuel cell buses at a fleet in Pomona, CA. The site was chosen because a temporary fueling solution was required while a fixed station was being installed. The existing permits for the fixed station and non-public access also was a determining factor. Over two months, the buses were fueled 320 times with over 5000 kg of hydrogen from tube trailers. Existing shore power was used, and the average electrical efficiency was 0.13 kWh/kg. The average liquid nitrogen (LIN) consumption was 90.68 scf/kg. The fueling and consumption data was provided to the National Renewable Energy Laboratory (NREL) for analysis. An economic analysis was performed and will be provided in a separate report. The project was successful, but not without challenges and lessons learned. The DOT special permit led the way for the use of high pressure, composite cylinders and is being by multiple other systems and applications. The pandemic along with time for the DOT special permit approval delayed the project for years. The team also believes that hydrogen mobile fueling has a use for the industry, especially during this upcoming phase of expansion. However, it does have its limitations due to high cost to build and operate, and the same permitting challenges as a fixed station. A fully capable system at the speeds and pressures of the AHMF may not be necessary for most applications and would help reduce the cost and increase storage capacity. The on-board generator can be easily replaced with shore power or the wide range of power generation solutions in the marketplace. One of the major results of the project was the development of new code language in National Fire Protection Agency (NFPA) 2 and the International Fire Code (IFC) for on-demand mobile fueling. This will provide guidance for Authorities Having Jurisdiction (AHJ) and user on how to permit temporary fueling sites across the nation.

08 HYDROGEN↗

The Influences of Neutron Irradiation on Aggregate Induced Degradation of Concrete

Reactor cavity concrete, the primary support structure for the reactor pressure vessel (RPV), is exposed to chronic neutron/gamma radiation during normal operation. During long term operation, the interaction of neutron irradiation with the concrete’s constituents may cause premature degradation of the concrete structure, as highlighted by a review of concrete properties in nuclear power plant environments. At high fluence levels, as in biological shielding, neutron irradiation may cause amorphization of the crystalline components of concrete, i.e., mineral aggregates, and volume changes, which are typically expansive in nature. Volume expansion can generate tensile stresses within concrete which can induce microcracking and/or result in debonding of aggregate with the matrix. On the other hand, structural disordering can result in changes in the stability of the phase in aqueous environments. This report presents the findings of investigations performed over 3 years through the collaboration of researchers from University of California, Los Angeles, Arizona State University, and Oak Ridge National Laboratory. The first part of the study addresses the effect of neutron irradiation on the durability of aggregates. Comparisons of aqueous dissolution rates, as a function of pH and temperature, were performed for aggregates that are either pristine (i.e., non-irradiated) or exposed to Ar+ ion irradiation at specified doses. These experimental results were coupled with molecular dynamics simulations of atomic scale changes in the crystallographic structure of the mineral and any resulting changes in physical properties (e.g., density) that result. The second section focuses on macroscopic effects of such changes in aggregate behavior in concrete degradation, primarily through changes in the concrete’s microstructure. Particularly, the effects akin to those originating from alkali-silica reaction (ASR) were evaluated. The project is structured to encompass 6 main tasks, as follows: Task 1: Selection of aggregates in relation to their abundance and mineralogy, and their irradiation Task 2: Molecular dynamics (MD): The effects of irradiation on the atomic disordering of aggregates Task 3: The influences of irradiation on aggregate reactivity Task 4: Reactive-transport simulation of expansive product formation in concrete microstructures Task 5: X-FEM-based modeling of damage evolution due to irradiation-induced aggregates reactions Task 6: Benchmarking, verification and validation of the simulation modules Thus, a rigorous understanding of irradiation-assisted mineral alterations was used to develop a mechanistic degradation model for concrete exposed to neutrons, while considering aspects of: chemical reaction (dissolution and precipitation), mass and ion transport, and damage evolutions. The models developed were embedded in a multi-physics aging code for nuclear components and structures called Grizzly, which allows for benchmarking, verification, and validation against expansion data acquired on concrete undergoing alkali-silica reaction, a physically/chemically equivalent form of degradation that develops in the absence of radiation. These findings provide insight into the sensitivities of minerals to irradiation, by highlighting characteristics of concretes and power plants subject to such risks. The research will aid the nuclear power industry to anticipate and mitigate such risks in light of second license renewals.

36 MATERIALS SCIENCE↗

Evaluation of superficial dosimetry between treatment planning system and measurement for several breast cancer treatment techniques

Purpose: Dosimetric accuracy in radiation treatment of breast cancer is critical for the evaluation of cosmetic outcomes and survival. It is often considered that treatment planning systems (TPS) may not be able to provide accurate dosimetry in the buildup region. This was investigated in various treatment techniques such as tangential wedges, field-in-field (FF), electronic compensator (eComp), and intensity-modulated radiotherapy (IMRT). Methods: Under Institutional Review Board (IRB) exemption, radiotherapy treatment plans of 111 cases were retrospectively analyzed. The distance between skin surface and 95% isodose line was measured. For measurements, Gafchromic EBT2 films were used on a humanoid unsliced phantom. Multiple layers of variable thickness of superflab bolus were placed on the breast phantom and CT scanned for planning. Treatment plans were generated using four techniques with two different grid sizes (1 Multiplication-Sign 1 and 2.5 Multiplication-Sign 2.5 mm{sup 2}) to provide optimum dose distribution. Films were placed at different depths and exposed with the selected techniques. A calibration curve for dose versus pixel values was also generated on the same day as the phantom measurement was conducted. The DICOM RT image, dose, and plan data were imported to the in-house software. On axial plane of CT slices, curves were drawn at the position where EBT2 films were placed, and the dose profiles on the lines were acquired. The calculated and measured dose profiles were separated by check points which were marked on the films before irradiation. The segments of calculated profiles were stretched to match their resolutions to that of film dosimetry. Results: On review of treatment plans, the distance between skin and 95% prescribed dose was up to 8 mm for plans of 27 patients. The film measurement revealed that the medial region of phantom surface received a mere 45%-50% of prescribed dose. For wedges, FF, and eComp techniques, region around the nipple received approximately 80% of prescribed dose, although only IMRT showed inhomogeneous dose profile. At deeper depths mainly (6-11 mm depths), film dosimetry showed good agreement with the TPS calculation. In contrast, the measured dose at a 3-mm depth was higher than TPS calculation by 15%-30% for all techniques. For the tangential and IMRT techniques, 1 Multiplication-Sign 1 mm{sup 2} grid size showed a smaller difference than that with a 2.5 Multiplication-Sign 2.5 mm{sup 2} grid size compared to the measurements. Conclusions: In general, TPS even with advanced algorithms do not provide accurate dosimetry in the buildup region, as verified by EBT2 film for all treatment techniques. For all cases, TPS and measured doses were in agreement from 6 mm in depth but differed at shallower depths. Grid size plays an important role in dose calculation. For accurate dosimetry small grid size should be used where differences are lower between TPS and measurements.

60 APPLIED LIFE SCIENCES↗

On the scattering power of radiotherapy protons

Purpose: First, to show that accurate formulas for scattering power T must take into account the competition between the Gaussian core and the single scattering tail of the angular distribution, which affects the rate of change in the Gaussian width and leads to the single scattering correction (SSC). Second, to show that the SSC requires that T(x) be nonlocal: Besides material properties and energy at the point of interest, it must depend in some fashion on how much multiple scattering has already taken place. Third, after reviewing five previous formulas (three local and two nonlocal), to derive an improved ''differential Moliere'' formula T{sub dM}. Last, to investigate, by studying some practical cases, when an accurate formula for T is actually needed. Methods: We first take the numerical derivative of the Moliere/Fano/Hanson <{theta}{sup 2}> in order to find the true SSC. We simplify the formula for T{sub IC} (ICRU Report 35) for protons, introducing a new material dependent property, the ''scattering length''X{sub S}, analogous to radiation length X{sub 0}. We then use T{sub IC} as a basis for T{sub dM} by including a nonlocal correction factor f{sub dM} which, by virtue of the Oeveraas approximation, parametrizes the single scattering correction. Results: The improved scattering power is T{sub dM}{identical_to}f{sub dM}(pv,p{sub 1}v{sub 1})x(E{sub s}/pv){sup 2}1/X{sub S} where f{sub dM}{identical_to}0.5244+0.1975 lg(1-(pv/p{sub 1}v{sub 1}){sup 2})+0.2320 lg(pv)-0.0098 lg(pv)lg(1-(pv/p{sub 1}v{sub 1}){sup 2}), p{sub 1}v{sub 1} (MeV) is the initial product of proton momentum and speed, pv is the same at the point of interest, and E{sub s}=15.0 MeV. T{sub dM} is easily computed and generalizes readily to mixed slabs because f{sub dM} is not material dependent. Conclusions: Whether an accurate formula for T is required depends very much on the problem at hand. For beam spreading in water, five of the six formulas for T give almost identical results, suggesting that patient dose calculations are insensitive to T. That is not true, however, of beam spreading in Pb. At the opposite extreme, the projected rms beam width at the end of a Pb/Lexan/air stack, analogous to the upstream modulator in a passive beam spreading system, is sensitive to T. In this case a simple experiment would discriminate between all but two of the six formulas discussed. Scattering power applies as much to Monte Carlo as to deterministic transport calculations. Using T in any of its forms will avoid step size dependence. Using the best available T could be important in general purpose Monte Carlo codes, which are expected to give the correct answer to many different problems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Time-dependent density-functional theory study on nonlocal electron stopping for inertial confinement fusion

Understanding laser–target coupling is of the utmost importance for achieving high performance in laser-direct-drive (LDD) inertial confinement fusion (ICF) experiments. Thus, accurate modeling of electron transport and deposition through ICF-relevant materials and conditions is necessary to quantify the total thermal conduction and ablation. The stopping range is a key transport quantity used in thermal conduction models; in this work, we review the overall role that the electron mean free path (MFP) plays in thermal conduction and hydrodynamic simulations. The currently used modified Lee–More model employs various physics approximations. We discuss a recent model that uses time-dependent density functional theory (TD-DFT) to eliminate these approximations in both the calculation of the electron stopping power and corresponding MFP in conduction zone polystyrene (CH) plasma. In general, the TD-DFT calculations showed a larger MFP (lower stopping power) than the standard modified Lee–More model. Using the TD-DFT results, an analytical model for the electron deposition range, λTD−DFT(ρ,T,K), was devised for CH plasmas between ρ=[0.05−1.05] g/cm3, kBT=[100−1000] eV. We implemented this model into LILAC, for simulations of a National Ignition Facility-scale LDD implosion and compared key physics quantities to ones obtained by simulations using the standard model. The implications of the obtained results and the path moving forward to calculate this same quantity in conduction-zone deuterium–tritium plasmas are further discussed, to hopefully close the understanding gap for laser target coupling in LDD-ICF simulations.

36 MATERIALS SCIENCE↗

SU-F-T-101: Insight into Dosimetry Workload and Planning Timelines: A 6 Year Review at One Institution

Purpose: To elucidate realistic clinical treatment planning workload and timelines to improve understanding for patients, payers, and other institutions involved in radiotherapy processes. Methods: A web based tool was developed using Oracle Express (Oracle Corp, Redwood City, CA) which allowed communication between the physicians and staff about the current state of the patient plan. For 6 years, all patient courses were logged and time-stamped in 22 discreet steps which detailed start and stop times for simulation, contouring, and treatment planning tasks. This data was combined with the treatment planning database (TPDB) using the Eclipse Scripting API (Varian Medical Systems, Palo Alto, CA) to cross-identify plans between the two systems. This time data was analyzed across our dosimetry staff and treatment modality. Results: In 6 years, 110,477 patient statuses were time-logged for 9683 courses of treatment using our internal software. The courses contained 8305 unique patients who were binned into one of 11 diagnosis site categories. 8253 courses could be reconciled against the TPDB using timestamp data from patient statuses. The average planning volume per dosimetrist was 375.8 ± 142.4 plans per year with the average number of planning revisions per dosimetrist of 71.0 ± 27.1 plans per year. The median treatment planning times by modality ranged from to 48.3 hours for IMRT plans 5 fields or less to 119.6 hours for IMRT with 8 or more fields. Two arc VMAT, three arc VMAT, and 3D plans median times were 89.1 hours, 113.8 hours, and 50.9 hours respectively. Conclusion: Using our web based tool, we have demonstrated the ability to quantify treatment planning timelines and workloads which could help in setting appropriate expectations for patients, payers, and hospital administration. COI: Author received monies from Varian Medical Systems for research and teaching honorarium.

60 APPLIED LIFE SCIENCES↗