Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacity test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

NASA mobile satellite program

A three phase development program for ground and space segment technologies which will enhance and enable the second and third generation mobile satellite systems (MSS) is outlined. Phase 1, called the Mobile Satellite Experiment (MSAT-X), is directed toward the development of ground segment technology needed for future MSS generations. Technology validation and preoperational experiments with other government agencies will be carried out during the two year period following launch. The satellite channel capacity needed to carry out these experiments will be obtained from industry under a barter type agreement in exchange for NASA provided launch services. Phase 2 will develop and flight test the multibeam spacecraft antenna technology needed to obtain substantial frequency reuse for second generation commercial systems. Industry will provide the antenna, and NASA will fly it on the Shuttle and test it in orbit. Phase 3 is similar to Phase 2 but will develop an even larger multibeam antenna and test it on the space station.

Knouse, G.↗

High temperature fatigue behavior of Haynes 188

The high temperature, creep-fatigue behavior of Haynes 188 was investigated as an element in a broader thermomechanical fatigue life prediction model development program at the NASA-Lewis. The models are still in the development stage, but the data that were generated possess intrinsic value on their own. Results generated to date is reported. Data were generated to characterize isothermal low cycle fatigue resistance at temperatures of 316, 704, and 927 C with cyclic failure lives ranging from 10 to more than 20,000. These results follow trends that would be predicted from a knowledge of tensile properties, i.e., as the tensile ductility varies with temperature, so varies the cyclic inelastic straining capacity. Likewise, as the tensile strength decreases, so does the high cyclic fatigue resistance. A few two-minute hold-time cycles at peak compressive strain were included in tests at 760 C. These results were obtained in support of a redesign effort for the Orbital Maneuverable System engine. No detrimental effects on cyclic life were noted despite the added exposure time for creep and oxidation. Finally, a series of simulated thermal fatigue tests, referred to as bithermal fatigue tests, were conducted using 316 C as the minimum and 760 C as the maximum temperature. Only out-of-phase bithermal tests were conducted to date. These test results are intended for use as input to a more general thermomechanical fatigue life prediction model based on the concepts of the total strain version of Strainrange Partitioning.

Halford, Gary R.↗

Primary battery design and safety guidelines handbook

This handbook provides engineers and safety personnel with guidelines for the safe design or selection and use of primary batteries in spaceflight programs. Types of primary batteries described are silver oxide zinc alkaline, carbon-zinc, zinc-air alkaline, manganese dioxide-zionc alkaline, mercuric oxide-zinc alkaline, and lithium anode cells. Along with typical applications, the discussions of the individual battery types include electrochemistry, construction, capacities and configurations, and appropriate safety measures. A chapter on general battery safety covers hazard sources and controls applicable to all battery types. Guidelines are given for qualification and acceptance testing that should precede space applications. Permissible failure levels for NASA applications are discussed.

Bragg, Bobby J.↗

Combining Fractional Calorimetry with Statistical Methods to Characterize Thermal Runaway

Fractional thermal runaway calorimetry (FTRC) techniques were introduced to examine thermal runaway (TR) behavior of lithium-ion (Li-ion) cells. Specifically, FTRC considers the total energy released vs. the fraction of the total energy that is released through the cell casing vs. through the ejecta material. This device has been expanded to universally support FTRC testing of additional cell types including 21700-format, D-Cell format, and large prismatic format Li-ion cells. The TR behavior as influenced by cell format, manufacturer, chemistry, capacity, and in situ safety features are described in this presentation.

Walker, William↗

Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Parallel computing for power system climate resiliency: Solving a large-scale stochastic capacity expansion problem with mpi-sppy

Here we propose a nodal stochastic generation and transmission expansion planning model that incorporates the output from high-resolution global climate models through load and generation availability scenarios. We implement our model in Pyomo and perform computational studies on a realistically-sized test case of the California electric grid in a high performance computing environment. We propose model reformulations and algorithm tuning to efficiently solve this large problem using a variant of the Progressive Hedging Algorithm. We utilize the parallelization capabilities and overall versatility of mpi-sppy, exploiting its hub-and-spoke architecture to concurrently obtain inner and outer bounds on an optimal expansion plan. Initial results show that instances with 360 representative days on a system with over 8,000 buses can be solved to within 5% of optimality in under 4 h of wall clock time, a first step towards solving a large-scale power system expansion planning problem across a wide range of climate-informed operational scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigating the effect of screen-printed structured graphite electrodes with low tortuosity for high-capacity and fast-charging lithium-ion batteries

A flexible screen-printed graphite electrode was fabricated as an anode for developing fast-charging lithium-ion batteries with low tortuosity. A homogenous anode ink was prepared by mixing graphite as the active material, carbon black (C45) as the conductive additive, and polyvinylidene fluoride (PVDF) as the binder in N-Methyl-2-pyrrolidone (NMP) solvent. The ink was deposited on a flexible copper foil via a stainless-steel screen consisting of an array of pores, that act as secondary pore networks (SPNs), using the screen-printing process. Lithium-ion battery half-cells were assembled using the printed graphite anode, lithium metal foil as the counter electrode, and 1.2 M lithium hexafluorophosphate (LiPF 6 ) in ethyl carbonate: ethyl methyl carbonate (EC: EMC = 3:7) as the electrolyte. The effect of SPNs on the cell performance was investigated by performing formation, rate and cycling tests on the assembled cells, at different C-rates. It was observed that the cells consisting of SPNs with a pore size of 100 μm and edge-to-edge distance of 100 μm between the pores exhibited significantly higher specific capacities of 168 and 129 mAh/g when compared to reference cells without SPNs, which had capacities of 120 and 85 mAh/g, at high C-rates of 4 C and 6 C, respectively. The cells with SPNs also demonstrated excellent cycling performance with ~ 95% capacity retention after 100 cycles at 2 C.

Fast charging lithium-ion battery↗

Fabrication and testing of silver-hydrogen cells

Silver electrodes containing various additives were fabricated and tested in single electrode cells in order to improve the electrochemical utilization of sintered silver cathodes in Ag-H2 aerospace batteries. A standard stack arrangement was used which featured a NASA-developed organic-inorganic separator. All cells were cycled in a regime designed to remove 75% of the cells nominal capacity based on 3.3 gms/AHr Ag utilization. In cases where performance degradation was observed, the main feature mode appeared to be corrosion of either the expanded silver current collector or the connection between the silver electrode and the electrode tab. Promising silver electrodes from single electrode studies were used in the construction of 35 AHr Ag-H2 cells. Two such cells were constructed and installed in heavy walled pressure vessels for testing. Based on the data obtained from all cells tested during the program, four lightweight 35 AHr cells were fabricated. During acceptance testing these cells yielded an average gravimetric energy density of 30 WHr/1b.

Debicarri, D. J.↗

Design and Manufacturing of High Performance, Reduced Charge Heat Exchangers

Air-to-fluid heat exchangers (HXs) play a critical role as the main heat transfer component in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) systems. However, their airside thermal resistance significantly inhibits their overall performance. Furthermore, these HXs must be continually more compact to meet the latest refrigerant charge limits to reduce emissions. Recent literature suggests that traditional HX geometries (e.g., round or flat tubes with fins), have reached their limits, and more sophisticated shape- and topology-optimized designs are required to achieve the next jump in performance. This research sheds light on the next generation of air-to-refrigerant HXs and aims to address several practical issues to commercialization such as novelty challenges (improved performance for significant charge reduction; modeling expertise & time investment), manufacturing challenges (non-round tube manufacturing; tube-header integration; product qualification, e.g., burst pressure testing, extreme operational environment, etc.), and operational challenges (flow maldistribution, fouling & wetting, noise & vibration). For example, a >20% improvement on one (or more) HX-level performance metrics (e.g., envelope volume, airside pressure drop, face area, capacity, refrigerant charge, weight, cost, etc.) must be achieved before a HX design is considered for commercialization. We present a new, comprehensive and experimentally validated air-to-refrigerant HX optimization framework with simultaneous thermal-hydraulic performance and mechanical strength considerations for novel, non-round, shape- and topology-optimized tubes capable of optimizing single and two-phase HX designs for any refrigerant choice and performance requirement with significant engineering time savings compared to conventional design practices. The framework was exercised for a wide range of applications and refrigerants, resulting in HXs which achieved greater than 20% improved performance, 20% reductions in size, and 25% reductions in refrigerant charge. To enable non-round tube bundle use in next generation HVAC&R equipment, novel manufacturing techniques were investigated, including the development of conventional manufacturing methods for small diameter, non-round tubes and novel tube-header integration strategies. In total, ten HX prototypes were manufactured, nine using conventional methods directly attributed to this project and one using advanced additive manufacturing methods. The five-year manufacturing feasibility of the proposed HXs was found to have a good outlook. The non-round tube HX simulated performance was validated through comprehensive experimental testing, including nine in-house component-level tests, one independent component-level test at an industry partner laboratory, and in-house system-level tests of using a commercially-available, residential packaged A/C unit which was retrofitted with a non-round tube prototype HX. It was found that HX designs proposed by the new framework can successfully predict experimental thermal-hydraulic performance within ±10-20% the first time with no manual design changes, eliminating the need for time-consuming and expensive prototyping efforts. This work will accelerate design and time to market for next generation HXs while simultaneously facilitating industry transition to new refrigerants at lower charge.

42 ENGINEERING↗

IAL SPACE: A test laboratory for the ISO cryogenic payload

The ESA Infrared Space Observatory (ISO) satellite is a 3 axes pointed platform designed to make accurate pointed observations of astronomical objects and sources in the wavelength range between 2.5 and 200 microns. ISO is composed of a service module and a payload module which is a large cylindrical vacuum vessel. The vessel is in fact a cryostat (capacity of 2250 l of liquid He II) which contains the telescope and the four focal scientific instruments. The latter being cooled up to a temperature less than 4 K. The qualification of the payload requires the measurement respectively of: the image quality of the telescope through wave front error (WFE) measurements; and the optical alignment of the scientific instruments with respect to the telescope axis and the telescope focus, and this under cryogenic conditions. Consequently, since 1988, the FOCAL 5 IAL Space facility has been upgraded in order to perform the cryogenic optical tests of the ISO optical subsystems.

Cucchiaro, A.↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

Synthesis and property of EPEG ‐based polycarboxylate ether superplasticizers via RAFT polymerization

Abstract Polycarboxylate ether superplasticizers (PCEs) with comb‐shaped molecular structures have attracted considerable attention in the area of admixtures for construction engineering. However, there are some contradictions in studying the relationship between the molecular structure and property of PCE due to its random structure based on traditional free radical polymerization, which is confused for designing and developing novel PCEs. In this article, a series of reversible addition fragmentation chain transfer (RAFT) polymerization‐based polycarboxylate ether superplasticizers (RPCs) were prepared by the copolymerization of acrylic acid (AA) and ethylene‐glycol monovinyl polyethylene glycol (EPEG). The chemical structure and composition of RPCs were characterized and their adsorption behavior and dispersion properties were conducted. The results demonstrate that the molecular weights of RPCs do not vary significantly with prolonging reaction time, and the actual monomer ratio in RPCs displays a significant change to the feed one due to the monomer reactivity and conversion at higher reaction temperature, which is different from conventional free radical polymerization. The dispersion and adsorption properties of RPCs to cement were evaluated by slurry fluidity tests and total organic carbon (TOC) experiments. The effect of polymerization temperature and time on the dispersion ability has been systematically studied. The results indicate that the dispersion ability and adsorption capacity of RPCs are closely related to their molecular structures. The dispersion ability of RPCs were enhanced with increasing carboxyl group density in a certain range of monomer molar ratios (≤6:1). This study will provide a new platform for designing and developing high‐performance and rational cost‐effective superplasticizers with well‐defined structure and controlled molecular weight.

Chen, Xiaodong↗

Carbonation reaction of recycled concrete aggregates (RCA): CO 2 mass consumption under various treatment conditions

Concrete is a key building material around the world due to its excellent strength and durability. Recycling demolished concrete for new construction materials may play a significant role in sustainable development. Producing recycled concrete aggregates (RCA) from waste concrete is one approach for such an initiative. However, using RCA may pose challenges, such as reduced density, lower elastic modulus and strength, and increased water absorption. Recently, the carbonation of RCA has emerged as a method to address those concerns. This study explores the carbon sequestration capacity of RCA through carbonation, examining various parametric conditions, including initial CO 2 pressure, relative humidity, temperature, and pre-treatment approach. Both lab-scale and large-scale carbonation tests were conducted. Additionally, a cost analysis and CO 2 footprint assessment were performed. The findings showed that applying higher initial CO 2 pressures (e.g., 40–60 psi) and optimal relative humidity (~55 %) could significantly enhance the carbonation efficiency of RCA. Elevating temperature also led to accelerated CO 2 consumption, being more effective on the lab scale. The economic analysis presented potential cost benefits when substituting natural aggregates with CO 2 -treated RCA. All in all, these results suggest that the carbonation of RCA may provide significant environmental benefits through carbon sequestration, promoting sustainable construction practices.

36 MATERIALS SCIENCE↗

Nickel Hydroxide Nanofluid Cathodes with High Solid Loadings and Low Viscosity for Energy Storage Applications

Nanofluid electrodes with high loading of active solid materials have significant potential as high energy density flow battery electrolytes; however, two key criteria need to be met: they must have a manageable viscosity for pumping and simultaneously exhibit good electrochemical activity. A typical dispersion of nickel hydroxide nanoparticles (~100 nm) is limited to 5–10 wt.% of solids, above which it has a paste-like consistency, incompatible with flow applications. We report on the successful formulation of stable dispersions of a nano-scale nickel hydroxide cathode (β-Ni(OH) 2 ) with up to 60 wt.% of solids and low viscosity (32 cP at 25 °C), utilizing a surface graft of small organic molecules. The fraction of grafting moiety is less than 3 wt.% of the nanoparticle weight, and its presence is crucial for the colloidal stability and low viscosity of suspensions. Electrochemical testing of the pristine and modified β-Ni(OH) 2 nanoparticles in the form of solid casted electrodes were found to be comparable with the latter exhibiting a maximum discharge capacity of ~237 mAh/g over 50 consecutive charge–discharge cycles, close to the theoretical capacity of 289 mAh/g.

25 ENERGY STORAGE↗

Some examples of the utility of HCMM data in geologic remote sensing

Examples of HCMM (Heat Capacity Mapping Mission) data in geologic remote sensing are presented, and the data set is composed of HCMM and aircraft digital scanner data and ground truth data from four western U.S. test sites. Data are used in the thermal model to test thermal data effectiveness, and changes in temperature with depth and time for dry soils are described by the model. It is found that the HCMM thermal inertia image is useful in the separability of bedrock and alluvium in Death Valley, and aa and pahoehoe flows in the Pisgah basalt flow. In a color composite of HCMM day temperature, night temperature, and day visible images of the Pisgah Crater test site, it is possible to distinguish alluvium, playa, aa and pahoehoe basalt flow, rhyolite intrusives, and other elements. Ground checking of units at a few points will extend capabilities to large areas and assist in creating telegeologic maps.

Kahle, A. B.↗

High-speed wide band 20 x 20 microwave switch matrix

The use of a dynamic switching matrix for future communication satellites will significantly increase the communication channel capacity and improve the system capability and flexibility. This paper describes the design and development of a unique coupler crossbar 20 x 20 microwave switch matrix. This paper also presents the test results of the proof-of-concept model that meets the requirements for a high-speed satellite switched, time division multiple access (SS-TDMA) system.

Coban, E.↗

Low temperature testing of Li-SOCl2 cells

The performance and safety characteristics Li-SOCl2 cells were evaluated at -40 C. Tests were conducted on cells of several defferent designs to determine the influence of cell design on performance and safety. The cells exhibited low operating voltages, poor voltage regulation, and low capacity at -40 C. The performance of the cells was found to be critically dependent on the cell design. No safety problems were observed during discharge to 2.0 V under constant current and constant load operating conditions. Cells subjected to prolonged periods of continuous drain at constant-load did not vent/rupture upon warm-up. Cells subjected to prolonged reversal were found to be potentially hazardous. Microcalorimetry and electrochemical impedance spectroscopy studies performed on the cells suggested that those containing a catalyst may exhibit poor shelf life.

Subbarao, S.↗

Transient response of a high-capacity heat pipe for Space Station Freedom

High-capacity heat pipe radiator panels have been proposed as the primary means of heat rejection for Space Station Freedom. In this system, the heat pipe would interface with the thermal bus condensers. Changes in system heat load can produce large temperature and heat load variations in individual heat pipes. Heat pipes could be required to start from an initially cold state, with heat loads temporarily exceeding their low-temperature transport capacity. The present research was motivated by the need for accurate prediction of such transient operating conditions. In this work, the cold startup of a 6.7-meter long high-capacity heat pipe is investigated experimentally and analytically. A transient thermohydraulic model of the heat pipe was developed which allows simulation of partially-primed operation. The results of cold startup tests using both constant temperature and constant heat flux evaporator boundary conditions are shown to be in good agreement with predicted transient response.

Ambrose, J. H.↗