Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Analysis of Wake VAS Benefits Using ACES Build 3.2.1: VAMS Type 1 Assessment

The FAA and NASA are currently engaged in a Wake Turbulence Research Program to revise wake turbulence separation standards, procedures, and criteria to increase airport capacity while maintaining or increasing safety. The research program is divided into three phases: Phase I near term procedural enhancements; Phase II wind dependent Wake Vortex Advisory System (WakeVAS) Concepts of Operations (ConOps); and Phase III farther term ConOps based on wake prediction and sensing. The Phase III Wake VAS ConOps is one element of the Virtual Airspace Modelling and Simulation (VAMS) program blended concepts for enhancing the total system wide capacity of the National Airspace System (NAS). This report contains a VAMS Program Type 1 (stand-alone) assessment of the expected capacity benefits of Wake VAS at the 35 FAA Benchmark Airports and determines the consequent reduction in delay using the Airspace Concepts Evaluation System (ACES) Build 3.2.1 simulator.

Smith, Jeremy C.↗

Software for Processing Flight and Simulated Data of the ATIC Experiment

ATIC (Advanced Thin Ionization Calorimeter) is a balloon borne experiment designed to measure the cosmic ray composition for elements from hydrogen to iron and their energy spectra from approx.50 GeV to near 100 TeV. It consists of a Si-matrix detector to determine the charge of a CR particle, a scintillator hodoscope for tracking, carbon interaction targets and a fully active BGO calorimeter. ATIC had its first flight from McMurdo, Antarctica from 28/12/2000 to 13/01/2001. The ATIC flight collected approximately 25 million events. A C++-class library for building different programs for processing flight and simulated data of the ATIC balloon experiment is described. This library is compatible with the ROOT-system and includes classes and methods for solving a number of problems as the following: Reading data files in different formats (raw-data format, ROOT-format, ASCII-format, different formats for simulated data); Transferring all these formats to the only inner format of the library; Reconstruction of trajectories of primary particles with BGO calorimeter only. The Monte-Carlo simulations with GEANT code were used to obtain the basic tables for computing error corridors and chi(sup 2)-values for the trajectories. Obtaining error corridors for searching for signal of primary particle in the Si-matrix; Searching for hit of primary particle in the Si-matrix with using of error corridor and other criteria (chi(sup 2)-values, agreement between signals in Si-matrix and in the upper layer of scintillator and others); Determination of charge of primary particle; Determination of energy deposit in BGO calorimeter.

Panov, A. D.↗

Overview of the Coupled Model Intercomparison Project Phase 6 (CMIP6) experimental design and organization

By coordinating the design and distribution of global climate model simulations of the past, current, and future climate, the Coupled Model Intercomparison Project (CMIP) has become one of the foundational elements of climate science. However, the need to address an ever-expanding range of scientific questions arising from more and more research communities has made it necessary to revise the organization of CMIP. After a long and wide community consultation, a new and more federated structure has been put in place. It consists of three major elements: (1) a handful of common experiments, the DECK (Diagnostic, Evaluation and Characterization of Klima) and CMIP historical simulations (1850–near present) that will maintain continuity and help document basic characteristics of models across different phases of CMIP; (2) common standards, coordination, infrastructure, and documentation that will facilitate the distribution of model outputs and the characterization of the model ensemble; and (3) an ensemble of CMIP-Endorsed Model Intercomparison Projects (MIPs) that will be specific to a particular phase of CMIP (now CMIP6) and that will build on the DECK and CMIP historical simulations to address a large range of specific questions and fill the scientific gaps of the previous CMIP phases. The DECK and CMIP historical simulations, together with the use of CMIP data standards, will be the entry cards for models participating in CMIP. Participation in CMIP6-Endorsed MIPs by individual modelling groups will be at their own discretion and will depend on their scientific interests and priorities. With the Grand Science Challenges of the World Climate Research Programme (WCRP) as its scientific backdrop, CMIP6 will address three broad questions: – How does the Earth system respond to forcing? – What are the origins and consequences of systematic model biases? – How can we assess future climate changes given internal climate variability, predictability, and uncertainties in scenarios? This CMIP6 overview paper presents the background and rationale for the new structure of CMIP, provides a detailed description of the DECK and CMIP6 historical simulations, and includes a brief introduction to the 21 CMIP6-Endorsed MIPs.

54 ENVIRONMENTAL SCIENCES↗

Development of Building Design Optimization Methodology: Residential Building Applications

Building design optimization is a highly complex problem, requiring long computational running processes because of the many options that exist when a building is being designed. This paper introduces an integrated approach through which to perform this optimization within an acceptable time frame. The approach includes the methods of variable selection, model simplification, and a sequential optimization process. Using singular value decomposition, a large number of design variables is reduced to a smaller subset that can be solved more quickly through the optimization algorithm. To expedite the variable selection process, a modeling approach that quickly simulates annual energy consumption was developed to replace full annual energy simulations. The developed methodology was applied to two residential buildings in the US, and the results are discussed herein. To assess the accuracy of the integrated optimization methodology, the optimized life cycle costs are compaa variables demonstrating the strongest contributions in the optimization study were identified. The proposed methodology significantly shortened the time requirements for the optimization processes of the two case studies by 74% and 84%; the optimized life cycle costs were within 0.05% and 0.06%, respectively, of the optimum point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of Coupon Testing of an IM7/8552 Composite Required to Characterize High-Energy Impact Dynamic Material Models

As part of NASA’s Advanced Composites Project (ACP), a significant research effort was established to develop and mature analysis methods for composite materials particularly applicable to high-energy dynamic impact applications. An overall goal was to develop and advance analysis methods that can be characterized using fundamental coupon level tests. Based on this fundamental characterization, simulations at the higher levels of a building block approach can be purely predictive. The tests described in this report were performed on a unidirectional carbon fiber polymer matrix composite, IM7/8552 tape, as this material system is representative of a modern aerospace grade carbon fiber tape system. These tests were chosen to provide fundamental material characterization data for three representative progressive damage and failure analysis material models available within the LS-DYNA commercial transient dynamic finite element code for use in the simulation of the dynamic and impact response of composite materials. Two of the material models, MAT162 and MAT261, are well established material models within LS-DYNA. The third material model, MAT213, is under active development. Testing consisted primarily of ASTM-type standard tests, and the tests that were performed were consistent with the needs of all three models. Additionally, coupon level tests were performed that can be used to characterize a delamination model (e.g., cohesive zone or tie-break contact). While, the tests described in this report provide fundamental material characterization data for all three of the material models mentioned above, the data is applicable to additional material models not discussed.

Justusson, Brian P.↗

Fast physics-based launcher optimization for electron cyclotron current drive

With the increased urgency to design fusion pilot plants, fast optimization of electron cyclotron current drive (ECCD) launchers is paramount. Traditionally, this is done by coarsely sampling the 4D parameter space of possible launch conditions consisting of (1) the launch location (constrained to lie along the reactor vessel), (2) the launch frequency, (3) the toroidal launch angle, and (4) the poloidal launch angle. For each initial condition, a ray-tracing simulation is performed to evaluate the ECCD efficiency. Unfortunately, this approach often requires a large number of simulations (sometimes millions in extreme cases) to build up a dataset that adequately covers the plasma volume, which must then be repeated every time the design point changes. Here we adopt a different approach. Rather than launching rays from the plasma periphery and hoping for the best, we instead directly reconstruct the optimal ray for driving current at a given flux surface using a reduced physics model coupled with a commercial ray-tracing code. Repeating this throughout the plasma volume requires only hundreds of simulations, constituting a significant speedup. The new method is validated on two separate example tokamak profiles, and is shown to reliably drive localized current at the specified flux surface with the same optimal efficiency as obtained from the traditional approach.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Power System Event Classification and Localization Using a Convolutional Neural Network

Detection and timely identification of power system disturbances are essential for situation awareness and reliable electricity grid operation. Because records of actual events in the system are limited, ensemble simulation-based events are needed to provide adequate data for building event-detection models through deep learning; e.g., a convolutional neural network (CNN). An ensemble numerical simulation-based training data set have been generated through dynamic simulations performed on the Polish system with various types of faults in different locations. Such data augmentation is proven to be able to provide adequate data for deep learning. The synchronous generators’ frequency signals are used and encoded into images for developing and evaluating CNN models for classification of fault types and locations. With a time-domain stacked image set as the benchmark, two different time-series encoding approaches, i.e., wavelet decomposition-based frequency-domain stacking and polar coordinate system-based Gramian Angular Field (GAF) stacking, are also adopted to evaluate and compare the CNN model performance and applicability. The various encoding approaches are suitable for different fault types and spatial zonation. With optimized settings of the developed CNN models, the classification and localization accuracies can go beyond 84 and 91%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Self-optimized construction of transition rate matrices from accelerated atomistic simulations with Bayesian uncertainty quantification

Here, a massively parallel method to build large transition rate matrices from temperature-accelerated molecular dynamics trajectories is presented. Bayesian Markov model analysis is used to estimate the expected residence time in the known state space, providing crucial uncertainty quantification for higher-scale simulation schemes such as kinetic Monte Carlo or cluster dynamics. The estimators are additionally used to optimize where exploration is performed and the degree of temperature acceleration on the fly, giving an autonomous, optimal procedure to explore the state space of complex systems. The method is tested against exactly solvable models and used to explore the dynamics of C15 interstitial defects in iron. Our uncertainty quantification scheme allows for accurate modeling of the evolution of these defects over timescales of several seconds.

36 MATERIALS SCIENCE↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Using AI Simulations to Dynamically Model Multi-agent Multi-team Energy Systems

The complexity of energy systems is well known as they are complex and intricate systems. As a result, many extant studies have used many simplifications or generalizations that do not accurately reflect the nature of this complex system. In particular, most HVAC systems are modeled as a single unit, or several large units, rather than as a hierarchical composite (e.g., as a floor rather than as a collection of disparate rooms). The net result of this is that the simulations are too generic to perform meaningful analysis, machine learning, or integrated simulation. We propose using a multi-agent multi-team strategic simulations framework called SiMAMT to better define, model, simulate, and learn the HVAC environment. SiMAMT allows us to create distinct models for each type of room, hierarchically aggregate them into units (like floors, or sections), and then into larger sets (like buildings or a campus), and then perform a simulation that interacts with each sub-element individually, the teams of sub-elements collectively, and the entire set in aggregation. Further, and most importantly, we additionally model another ‘team’ within the simulation framework - the users of the systems. Again, each individual is modeled distinctly, aggregated into sub-sets, then collected into large sets. Each user, or agent, is performing on their own but with respect to the larger team goals. This provides a simulation that has a much higher model fidelity and more applicable results that match the real-world.

Franklin, D. Michael↗

A Study of Cost-Saving Potential of Load Flexibility Measures in Grid-Interactive Multifamily Buildings

With recent advances in smart technologies, more and more smart devices are penetrating the residential and commercial buildings market. The introduction of these smart devices is also helping IoT companies emerge with load aggregator roles in the sector. With more utility companies on the track of supporting OpenADR protocols, the aggregators could play a significant role in providing load flexibilities by automatically responding to demand response (DR) events and coordinating load flexibility measures between customers. This would benefit utility companies by reducing stress on the grid during critical peak demand hours as well as customers by allowing them to utilize utility rate structures advantageous to those able to reduce electric usage during high-demand hours. This study evaluates cost and energy savings from adopting multiple load flexibility measures in multifamily buildings. Combinations of different load flexibility measures, including space temperature floating, light dimming, automatic window shading, and water heater temperature floating, are considered. The simulations are performed using OpenStudio®, an open-source U.S. Department of Energy (DOE) simulation platform. For the case study, we used a midrise apartment building with weather conditions from Denver, Colorado. To compare climate zone differences, simulations were also performed for Los Angeles, California, and Chicago, Illinois. Initial results indicate that the application of automated load flexibility measures without careful consideration of dispatching strategies and DR program enrollments could significantly affect the savings. To get meaningful cost savings, aggregators need to encourage tenant awareness to curtail energy usage through occupant behavior in addition to dispatching automatic load flexibility measures. The outcomes from this study are believed to help load aggregators understand the risks and benefits of load flexibility opportunities.

building energy modeling↗

Interfacial characteristics of P91 steel - Inconel 740H bimetallic structure fabricated using wire-arc additive manufacturing

Although bimetallic structures can offer unique solutions to engineering problems with varying functionality, joining two dissimilar alloys using additive manufacturing involves challenges such as cracking and segregation. In this work, bimetallic structures of Inconel 740H superalloy and P91 steel are processed using wire-arc additive manufacturing (WAAM) for the first time. P91 steel is directly deposited over 740H with a cooling time of 20 minutes in between the two depositions. During microstructure characterization, a large gradient zone with coarse grains spanning for ~2200 μm is observed. Moreover, the microhardness of the gradient zone is the least in comparison with the P91 and 740H deposits. No deleterious phase formation is found; however, intergranular cracks are observed along the gradient zone. In order to deduce the reason for cracking, non-equilibrium solidification simulations are performed for the mixed compositions of P91 and 740H in the gradient zone. Here, the reasons for crack formation in the gradient zone are the sudden change in the volumetric coefficient of thermal expansion due to the formation of MC carbides as well as the development of local strains from the thermal residual stresses. Therefore, altering the deposition sequence and introducing gradient layers with mixed composition between the P91 and 740H deposits will be beneficial in achieving defect-free builds. Through the integration of experiments and simulation, this work gains valuable insights into the processability of dissimilar alloy manufacturing using the WAAM technique.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis of building heating and cooling

Energy Conservation Program (ECP) gives design engineer methodology and easy-to-use computer program for simulating hourly thermal characteristics over full year for individually characterized zones within building. Inexpensive system can be used to develop thermal model of building to aid selection of most suitable and economical heating and cooling system for building

Chai, V. W.↗

CFD: A Castle in the Sand?

The computational simulation community is not routinely publishing independently verifiable tests to accompany new models or algorithms. A survey reveals that only 22% of new models published are accompanied by tests suitable for independently verifying the new model. As the community develops larger codes with increased functionality, and hence increased complexity in terms of the number of building block components and their interactions, it becomes prohibitively expensive for each development group to derive the appropriate tests for each component. Therefore, the computational simulation community is building its collective castle on a very shaky foundation of components with unpublished and unrepeatable verification tests. The computational simulation community needs to begin publishing component level verification tests before the tide of complexity undermines its foundation.

Kleb, Bil↗