Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “attenuator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

TPSAS-NF1676L-31882-DND

Lidar ratios are required to retrieve the extinction profiles in CALIOP algorithm. Unconstrained retrievals: A default lidar ratio is used depending upon the aerosol subtype. Constrained retrievals: The lidar ratio (S) is retrieved from the measured two way transmittance (T2), when clear air is found both above and below the layer for at least 2.5 km (T^2 = / ; S = (1-T2)/2γ’), where and are the mean attenuated scattering ratios below and above the layer respectively, and γ’ is the layer integrated attenuated backscatter. A multiple scattering factor of 1 is assumed. In general, constrained lidar ratios are expected to be more representative (but also noisier) than the unconstrained cases, hence accuracy of the unconstrained lidar ratios can be assessed using the constrained ones.

J Kar↗

TPSAS-NF1676L-29931-DND

The ACE science working group satellite concept calls for a combination of high spectral resolution aerosol lidar and a polarimeter able to determine vertical profiles of aerosol extinction and clouds. Here we discuss why an HSRL lidar is required to achieve these requirements. The primary advantage of an HSRL over an elastic backscatter lidar is that the HSRL channel allows for the independent retrieval of vertically resolved aerosol extinction without constraint. Not requiring a constraint means greater availability of retrievals in polar regions, on the night side, and in broken cloud situations, plus greater accuracy particularly in the lowest part of the atmosphere and in scenes with aerosol heterogeneity. Advantages go beyond the extinction products. Unlike attenuated backscatter, which is an integrated quantity, the aerosol backscatter coefficient depends only on the aerosol at a specific level in the atmosphere, making it preferable for use in quantitative applications. The aerosol backscatter coefficient is more accurate from an HSRL system compared to the retrieval from a single-channel system. This is because errors in both extinction and backscatter from a single-channel system increase with decreasing altitude, due to the need to accurately characterize the overlying attenuation. This means that an HSRL will also have more valid data in and near the boundary layer where aerosol is of primary interest for air quality and weather applications and for many climate objectives including aerosol-cloud interaction studies. Even cloud properties that do not directly use the HSRL capability (cloud phase and thin cirrus retrievals) benefit from the more accurate calibration of an HSRL system. The improved accuracy of backscatter and extinction also lead to better capabilities for aerosol typing, improved retrievals of aerosol radiative effect, and increased information content for combined lidar + polarimeter retrievals of profiles of microphysical properties such as vertically resolved effective radius.

S P Burton↗

TPSAS-NF1676L-16762-DND

Multi-Mission Earth Entry Vehicles (MMEEVs) are blunt-body vehicles designed with the purpose of transporting payloads from outer space to the surface of the Earth. To achieve high-reliability and minimum weight, MMEEVs avoid use of limited-reliability systems, such as parachutes and retro-rockets, instead using built-in impact attenuators to absorb energy remaining at impact to meet landing loads requirements. In the current effort, two different Rohacell foams were tested to determine their thermal conductivity in support of MMEEV design applications. These applications include thermal insulation during atmospheric entry, impact attenuation, and post-impact thermal insulation. Results indicate that for these closed-cell foams, the effect of impact is limited on thermal conductivity due to the venting of the virgin material gas and subsequent ambient air replacement. In addition, thermal conductivity results indicate a variation with temperature and are higher than manufacturer's specifications.

Lou Glaab↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Determination of the NOAA-20 VIIRS screen transmittance functions with both the yaw maneuver and regular on-orbit calibration data

The Visible Infrared Imaging Radiometer Suite (VIIRS) aboard theNOAA-20 satellite regularly performs on-orbit radiometric calibration of its reflective solar bands (RSBs) through observations of an onboard sunlit solar diffuser (SD). The incident sunlight passes through an attenuation screen (the SD screen) and then scatters off the SD to provide a radiance source for the calibration. The on-orbit change of the SD’s bidirectional reflectance distribution function (BRDF), referred to as the H-factor, is determined by an onboard solar diffuser stability monitor (SDSM) whose eight detectors alternately observe the Sun through another attenuation screen (the SDSM screen) and the sunlit SD. The products of the SD screen transmittance and the BRDF at the mission start for both the SDSM and RSBs and the SDSM screen effective transmittance were measured prelaunch. Large unrealistic undulations in the retrieved H-factor were seen when using the prelaunch screen functions. To improve the accuracy of the retrieved H-factor, shortly after the satellite launch, 15 yaw maneuvers were performed to further characterize the screens. Although significantly improved, the H-factor derived using the screen functions determined fromthe yaw maneuver data still has large unrealistic undulations, revealing that the solar azimuth angular step size of the yaw maneuvers is too large. In this paper,we add high-quality regular on-orbitSDcalibration data to the yaw maneuver data to further improve the relative product of the SD screen effective transmittance and the BRDF at the mission start for the SDSM and the SDSM screen relative effective transmittance. The H-factor time series derived from the newly determined screen transmittance functions is much smoother than that derived from using only the yaw maneuver data and thus considerably improves the radiometric calibration accuracy.

Ning Lei↗

Characteristics of DSD Bulk Parameters: Implication to Radar Rain Retrieval

With the use of 213,456 one-minute measured data of droplet-size distribution (DSD) of rain collected during several National Aeronautics and Space Administration (NASA)-sponsored field campaigns, the relationships between rainfall rate R, mass-weighted diameter D(m) and normalized intercept parameter N(w) of the gamma DSD are studied. It is found, based on the simulations of the gamma DSD model, that R, D(m) and N(w) are closely interrelated, and that the ratio of R to N(w) is solely a function of D(m), independent of the shape factor μ of the gamma distribution. Furthermore, the model-produced ratio agrees well with those from the DSD data. When a power-law equation is applied to fit the model data, we have: R=aN(w)D(sup b, sub m) , where a=1.588×10(exp −4) , b=4.706 . Analysis of two-parameter relationships such as R–D(m), N(w)–R and N(w)–D(m) reveals that R and D(m) are moderately correlated while N(w) and D(m) are negatively correlated. N(w) and R, however, are uncorrelated. The gamma DSD model also reveals that variation of R–D(m) relation is caused primarily by N(w). For the application of the Ku- and Ka-band dual-frequency radar for the retrieval of the DSD bulk parameters as well as the specific radar attenuations, the study is carried out to relate the dual-frequency radar reflectivity factors to the DSD and attenuation parameters.

Liang Liao↗

The UV Aerosol Extinction Coefficients Retrieval Using the Ground-Based Ozone Lidar

NASA Langley Mobile Ozone Lidar (LMOL) has capability to measure the O3 concentration from 0.1 to 8 km. A new method is proposed to retrieve the aerosol backscatter and extinction coefficients from the LMOL attenuated backscatter signals. The LMOL attenuated backscatter data are corrected by the O3 concentration determined by LMOL system. The aerosol extinction coefficients are retrieved by using Fernald-type method. The retrieved aerosol extinction coefficient profiles are compared with the coincident aerosol extinction coefficient profiles provided by overflights of the airborne High Altitude Lidar Observatory (HALO) system during the 2018 LISTOS campaign. Results show the new method has the capability to retrieve aerosol extinction coefficients from 0.1-8 km at night and 0.1-4 km during the day for 5 minute temporal averaging. The profile time series of the retrieved aerosol extinction coefficient are also compared with co-located ceilometer data, showing general agreement with aerosol features and dynamics. The impact of lidar extinction to backscatter ratios on the retrievals is also presented.This new method extends LMOL’s ability to quantitatively determine the vertical distribution of aerosol optical properties. This is expected to contribute to further understanding of the relationship between the ozone and aerosol in the wildfire emissions transport and impact on local air quality during the LISTOS campaign.

Liqiao Lei↗

Improved Pyrotechnic Shock Scaling Method Based on Shock Response Spectrum and Statistical Energy Analysis

It has been more than forty years since the pyrotechnic shock scaling method was introduced. The scaling method estimates the attenuation of the Shock Response Spectrum (SRS) based on the distance from the source, structural configurations, types of structural joints and interfaces, and intervening structure [1]. The method has been successfully used in the spacecraft community countless times and still is frequently used to develop pyrotechnic shock requirements at various levels of assembly of a spacecraft. However, since the method was derived empirically from a limited set of shock test data [2], the aerospace community has been looking for an alternative approach. In this paper, a computational scaling method based on Statistical Energy Analysis (SEA) is re-visited. SEA is traditionally used as a method for investigating the diffusion of acoustic and vibratory energies of a system at steady-state [3]. Previously, an approach using the SRS as an acceleration constraint condition to the SEA model was introduced to estimate the attenuation from a shock source [4,5]. In the current investigation, additional examples are provided to further validate the approach. In addition, responses in the time domain are produced by the Local Modal Phase Reconstruction (LMPR) approach which was recently introduced to the community [6].

Fernandez, Juan P.↗

High Spectral Resolution Datasets of in Situ Aquatic Inherent and Apparent Optical Properties

Light emerging from natural water bodies and measured by remote sensing radiometers contains information about the local type and concentrations of phytoplankton, non-algal particles and colored dissolved organic matter in the underlying waters. An increase in spectral resolution in forthcoming satellite and airborne remote sensing missions is expected to lead to new or improved capabilities to characterize aquatic ecosystems. Such upcoming missions include NASA’s Plankton, Aerosol, Cloud, ocean Ecosystem PACE Mission; the NASA Surface Biology and Geology observable mission; and NASA Airborne Visible / Infrared Imaging Spectrometer (AVIRIS) - Next Generation airborne missions. In anticipation of these missions, we present a dataset of geographically diverse, quality-controlled, high spectral resolution inherent and apparent optical property (IOP/AOP) aquatic data. The data are intended to be of use to increase our understanding of aquatic optical properties, to develop aquatic remote sensing data product algorithms, and to perform calibration and validation activities for forthcoming aquatic-focused imaging spectrometry missions. The dataset is comprised of contributions from several investigators and investigating teams collected over a range of geographic areas and water types, including inland water, estuaries and oceans. Specific in situ measurements include particulate absorption, particulate attenuation, non-algal particulate or detritus absorption, colored dissolved organic matter absorption, phytoplankton absorption, total absorption, total attenuation, particulate backscattering, total backscatter, remote sensing reflectance, and irradiance reflectance. The dataset can be downloaded from PANGAEA: (https://www.pangaea.de/TBD ).

K A Casey↗

Impacts of Water Clarity Variability on Temperature and Biogeochemistry in the Chesapeake Bay

Estuarine water clarity depends on the concentrations of aquatic constituents, such as colored dissolved organic matter, phytoplankton, inorganic suspended solids, and detritus, which are influenced by variations in riverine inputs. These constituents directly affect temperature because when water is opaque, sunlight heats a shallower layer of the water compared to when it is clear. Despite the importance of accurately predicting temperature variability, many numerical modeling studies do not adequately account for this key process. In this study, we quantify the effect of water clarity on heating by comparing two simulations of a hydrodynamic-biogeochemical model of the Chesapeake Bay for the years 2001–2005, in which (1) water clarity is constant in space and time for the computation of solar heating, compared to (2) a simulation where water clarity varies with modeled concentrations of light-attenuating materials. In the variable water clarity simulation, the water is more opaque, particularly in the northern region of the Bay. This decrease in water clarity reduces the total heat, phytoplankton, and nitrate throughout the Bay. During the spring and summer months, surface temperatures in the northern Bay are warmer by 0.1 °C and bottom temperatures are colder by 0.2 °C in the variable light attenuation simulation. Warmer surface temperatures encourage phytoplankton growth and nutrient uptake near the head of the Bay, and fewer nutrients are transported downstream. These impacts are greater during higher river flow years, when differences in temperature, nutrients, phytoplankton, and zooplankton extend further seaward compared to other years. This study demonstrates the consequences of utilizing different light calculations for estuarine heating and biogeochemistry.

water clarity↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗

Relationship between Horizontal Wind Velocity and Normalized Surface Cross Section Using Data from the HIWRAP Dual-Frequency Airborne Radar

The High-Altitude Imaging Wind and Rain Airborne Profiler (HIWRAP) dual-frequency conically scanning airborne radar provides estimates of the range-profiled mean Doppler and backscattered power from the precipitation and surface. A velocity–azimuth display analysis yields near-surface estimates of the mean horizontal wind vector υh in cases in which precipitation is present throughout the scan. From the surface return, the normalized radar cross section (NRCS) is obtained, which, by a method previously described, can be corrected for path attenuation. Comparisons between υh and the attenuation-corrected NRCS are used to derive transfer functions that provide estimates of the wind vector from the NRCS data under both rain and rain-free conditions. A reasonably robust transfer function is found by using the mean NRCS (⟨NRCS⟩) over the scan along with a filtering of the data based on a Fourier series analysis of υh and the NRCS. The approach gives good correlation coefficients between υh and ⟨NRCS⟩ at Ku band at incidence angles of 30° and 40°. The correlation degrades if the Ka-band data are used rather than the Ku band.

R Meneghini↗

The Precipitation Rate Retrieval Algorithms for the GPM Dual-frequency Precipitation Radar

In this paper, precipitation rate retrieval algorithms for the Global Precipitation Measurement mission's Dual-frequency Precipitation Radar (DPR) are developed. The DPR consists of a Ku-band radar (KuPR; 13.6 GHz) and a Ka-band radar (KaPR; 35.5 GHz). For the KuPR, an algorithm similar to the Tropical Rainfall Measuring Mission's Precipitation Radar algorithm is developed, with the relation between precipitation rate R and massweighted mean diameter D m (R−D m relation) replacing the relation between the specific attenuation k and effective radar reflectivity factor Z e . The R−D m relation can also be applied to the KaPR and dual-frequency algorithms. In both the single-frequency and dual-frequency algorithms, the forward retrieval method is applied with an assumed adjustment factor for the R−D m relation (ε) and the results are evaluated to select the best value of ε. The advantages of the dual-frequency algorithm are the availability of the dual-frequency surface reference technique and the ZfKa method, which is a method to use the attenuation-corrected radar reflectivity factor Z f of KaPR, to select ε as well as the possibility to selectively use measurements from KuPR or KaPR. This paper also describes the derivation of the scattering table and the R−D m relation as well as the procedure for non-uniform beam filling correction in detail. The outputs are then statistically analyzed to demonstrate algorithm performance.

precipitation radar↗

The Toba Supervolcano Eruption Caused Severe Tropical Stratospheric Ozone Depletion

Supervolcano eruptions have occurred throughout Earth’s history and have major environmental impacts. These impacts are mostly associated with the attenuation of visible sunlight by stratospheric sulfate aerosols, which causes cooling and deceleration of the water cycle. Supereruptions have been assumed to cause so-called volcanic winters that act as primary evolutionary factors through ecosystem disruption and famine, however, winter conditions alone may not be sufficient to cause such disruption. Here we use Earth system model simulations to show that stratospheric sulfur emissions from the Toba supereruption 74,000 years ago caused severe stratospheric ozone loss through a radiation attenuation mechanism that only moderately depends on the emission magnitude. The Toba plume strongly inhibited oxygen photolysis, suppressing ozone formation in the tropics, where exceptionally depleted ozone conditions persisted for over a year. This effect, when combined with volcanic winter in the extra-tropics, can account for the impacts of supereruptions on ecosystems and humanity.

Atmospheric chemistry↗

Quantifying the Observational Requirements of a Space-borne LiDAR Snow Mission

This study quantifies the level of observational accuracy required from a spaceborne light detection and ranging (LiDAR) snow depth retrieval mission for enabling beneficial impacts for snow estimation. The study is conducted over a region in Western Colorado using a suite of observing system simulation experiments(OSSEs).The Joint UK Land Environment Simulator, version 5.0 (JULES v5.0) is employed to simulate a suite of idealized LiDAR observations, considering a range of LiDAR snow depth retrieval errors, different hypothetical sensor swath widths, and the impact of cloud cover on observability. These simulated observations are then assimilated into the Noah land surface modelwith multi-parameterization options, version 3.6 (Noah-MP v3.6) model. This data assimilation setup is used to systematically evaluate the potential utility of LiDAR observations for improving modeled snow water equivalent (SWE)estimates and water budget variables such as runoff. Results from the OSSE runsshow that, in general, assimilation of synthetic LiDAR observations provide beneficial impacts when theLiDAR snow depth retrieval error standard deviation (σerror) is below 60 cm.Based on comparisons between the realistic (i.e., swath-limited and cloud-attenuated) case and the idealized (i.e., infinite swath width in the absence of cloud cover) case,this study concludes that observations with a conservative error standard deviation threshold of 40 cm (i.e., upper limit of the snow depth retrieval error that adds value to the SWE estimates viaassimilation) are needed for improving modeled snow estimates. More than a 33% reduction in SWEroot mean square errors and more than a 15% increase in correlation coefficientsare achieved when σ error ≤ 40 cmusing a 170-km sensor swath width in the presence of cloud attenuation effects. Further, the integrated hydrologic response, as represented by total (surface and subsurface) runoff estimates during the snow ablation season, are also enhanced when assimilating synthetic LiDAR snow depth retrievals with errors below this level.

Yonghwan Kwon↗

On the Cycling of 231 Pa and 230 Th in Benthic Nepheloid Layers

The naturally-occurring radionuclides protactinium-231 ( 231 Pa) and thorium-230 ( 230 Th) are produced at approximately uniform rates in the ocean and thought to be removed from the water column through a reversible exchange with settling particles. Recent measurements along the U.S. GEOTRACES North Atlantic transect (GA03) revealed two features which are at odds with current understanding about 231 Pa and 230 Th cycling in the ocean: (i) a sharp decrease in dissolved 231 Pa ( 231 Pa d ) and 230 Th ( 230 Th d ) activities with depth below 2000-4000 m and (ii) very high particulate 231 Pa ( 231 Pa p ) and 230 Th ( 230 Th p ) activities near the bottom, at a number of stations between the New England continental shelf and Bermuda. Concomitant measurements of light attenuation from beam transmissometry showed that both features occur in benthic nepheloid layers (BNLs), which suggests that these features may stem, at least partly, from the presence of resuspended sediment in the deep water column. Here we explore the behaviour of 231 Pa and 230 Th in BNLs by using (i) radionuclide, optical, and hydrographic data from the western segment of GA03 (west of Bermuda) and (ii) a simplified model of particle and radionuclide cycling that includes a lateral particle source. First, the BNLs observed at GA03 stations are characterized from measurements of the beam attenuation coefficient converted to particle concentrations. At all stations, particle concentrations below the clear water minimum were the highest in the bottom mixed layer, whose thickness ranged from 95 to 320 m, and decreased generally with height above the bottom. The thickness of strong BNLs varied from 482 to 1358 m and the vertical integral of particle concentration in excess to that at the clear water minimum varied from 1 x 10 4 to 2 x 10 6 mg m −2 , among different stations. Second, the particle-radionuclide model is fitted to data from stations GT11-04 (New England continental rise) and GT11-08 (Hatteras abyssal plain), where samples for radionuclide analyses were collected in the BNL. The model can reproduce simultaneously the increase of particle concentration with depth, the low 231 Pa d and 230 Th d in the BNLs, and the high 231 Pa p and 230 Th p near the bottom. According to the model, at heights less than about 300 m above the seafloor, the dissolved phase was set primarily by a balance between adsorption and desorption, with vertical turbulent mixing playing a secondary role, whilst the particulate phase behaved largely as a non-reactive constituent supplied laterally and transported vertically by particle settling and turbulent mixing. Sensitivity tests with the model suggest that lateral particle sources near continental slopes and similar reliefs can produce significant biases both in the 230 Th normalization method and in the interpretation of sediment 231 Pa/ 230 Th records. Our findings yield insights into the influence of sediment resuspension and transport on 231 Pa and 230 Th in the deep ocean and highlight the need for considering these processes in paleoceanographic applications.

Nepheloid layer↗

Mitigating Headward Fluid Shifts with Venoconstrictive Thigh Cuffs during Spaceflight

Venoconstrictive thigh cuffs (VTC) are a mechanical countermeasure capable of attenuating the spaceflight induced headward fluid shift, and thus may be a viable spaceflight associated neuro-ocular syndrome (SANS) countermeasure. Crewmembers can use VTC to mitigate the headward fluid shift to aid in adapting to spaceflight. However, data are needed to determine if VTC affect ocular structures. PURPOSE The purpose of this study is to determine the efficacy of long duration use of VTC application to mitigate the spaceflight-induced headward fluid shift. We hypothesize that a VTC countermeasure will temporarily reverse the headward fluid shift and attenuate spaceflight-induced changes of internal jugular vein (IJV) cross-sectional area, IJV pressure, stroke volume, cardiac output, intraocular pressure (IOP), and optic nerve head and retinal morphology. METHODS This study will evaluate the effectiveness of VTC countermeasure application on the headward fluid shift, as well as cardiovascular and ocular variables. VTC during spaceflight will be worn for an extended duration (up to 6 hours) with data collected at three time points (30 minutes, 3 hours, and 6 hours) to characterize the temporal profile of key fluid shift outcome measures of the vascular fluid shift, IOP, and ocular structure changes. Ten astronauts will be recruited to participate and will be studied before and during approximately 180-day International Space Station (ISS) spaceflight missions. Baseline data collection will occur approximately 90-days before launch (Figure). Preflight, each leg of the crewmember will be measured to determine the VTC cuff size and a cuff fit check session will occur prior to the preflight baseline ground imaging to verify the appropriate fit measured via a surface contact pressure. Prior to donning the VTC, baseline measures without VTC will be collected seated, supine, and supine followed by data collection with the VTC. The baseline data collection will include ultrasound (IJV area and pressure, stroke volume and cardiac output), brachial blood pressure and heart rate, optical coherence tomography (OCT) imaging (total retinal thickness and choroid thickness), and IOP. An inflight cuff fit check session, same as the preflight fit check, will occur prior to VTC use on ISS. The inflight VTC experiment will be conducted early (FD45) and late (R-45) to determine if mission duration affects VTC fit and the efficacy of fluid redistribution. A system usability scale comfort questionnaire will be included in each VTC session to capture feedback from crewmembers regarding the comfort and usability of the VTC. SCIENTIFIC & MISSION IMPACT Results will narrow knowledge gaps described in the Human Research Roadmap to mitigate the headward fluid shift during spaceflight and help NASA to 1) determine the efficacy of extended use VTC application to mitigate the spaceflight-induced headward fluid shift and 2) further the understanding of the use of VTC on vascular fluid shifts, IOP, and ocular structure during spaceflight. Supported by NASA Human Research Program Directed Research. Figure. Detailed Testing Schedule. Baseline data collection at L-90 will be performed in a randomized order of position.

J V Jasien↗

Components Cleaning Facility, SWMU 030 Eastern High-Concentration Plume Area Implementation Work Plan Kennedy Space Center, Florida

This Implementation Work Plan (IWP) presents detailed design elements and coordination specifics to implement an air sparging (AS) Interim Measure (IM) to remediate groundwater at the Components Cleaning Facility (CCF), Eastern High Concentration Plume (HCP) Area located at Kennedy Space Center (KSC), Florida. The objective of the CCF East IM is to remediate groundwater where trichloroethene, cis-1,2-dichloroethene, and vinyl chloride concentrations exceed Florida Department of Environmental Protection Natural Attenuation Default Criteria (NADC) (identified as the HCP) via AS and to transition to monitored natural attenuation. CCF has been designated Solid Waste Management Unit 030 under KSC’s Resource Conservation and Recovery Act Corrective Action Program.

James Lloyd↗