Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Valve”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Imaging Strategies for Evaluating Low-Flow, Low-Gradient Aortic Stenosis with Reduced and Preserved Left Ventricular Ejection Fraction

Purpose of Review: Aortic stenosis (AS) is one of the most common valvular heart diseases, and aortic valve replacement (AVR) provides both symptomatic and survival benefit in symptomatic severe AS patients. The purpose of this review is to discuss low-flow low-gradient AS which is still a challenging diagnostic entity. Recent Findings: Thirty–forty percent of patients with AS have low flow which makes it difficult to differentiate truly severe AS that benefits from AVR compared to pseudo-severe AS which is currently managed conservatively. Patients with low-flow low-gradient AS (LF-LG AS) include those with reduced left ventricular systolic function (classical LF-LG AS) and those with preserved left ventricular systolic function (paradoxical LF-LG AS). Low-dose dobutamine stress echocardiography (DSE) helps to identify truly severe stenosis in patients with classical LF-LG AS. Aortic valve calcium scoring with multidetector computed tomography plays a major role in patients with paradoxical LF-LG AS and also among classical LF-LG AS patients who have reduced contractile reserve on DSE. Summary: This article will provide an overview of imaging strategies for evaluating LF-LG AS with reduced and preserved left ventricular ejection fraction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic calculation of myocardial external efficiency using a single {sup 11}C-acetate PET scan

Background: Myocardial external efficiency (MEE) is defined as the ratio of kinetic energy associated with cardiac work [forward cardiac output (FCO)*mean systemic pressure] and the chemical energy from oxygen consumed (MVO{sub 2}) by the left ventricular mass (LVM). We developed a fully automated method for estimating MEE based on a single {sup 11}C-acetate PET scan without ECG-gating. Methods and Results: Ten healthy controls, 34 patients with aortic valve stenosis (AVS), and 20 patients with mitral valve regurgitation (MVR) were recruited in a dual-center study. MVO{sub 2} was calculated using washout of {sup 11}C -acetate activity. FCO and LVM were calculated automatically using dynamic PET and parametric image formation. FCO and LVM were also obtained using cardiac magnetic resonance (CMR) in all subjects. The correlation between MEE{sub PET-CMR} and MEE{sub PET} was high (r = 0.85, P < 0.001) without significant bias. MEE{sub PET} was 23.6 ± 4.2% for controls and was lowered in AVS (17.2 ± 4.3%, P < 0.001) and in MVR (18.0 ± 5.2%, P = 0.004). MEE{sub PET} was strongly associated with both NYHA class (P < 0.001) and the magnitude of valvular dysfunction (mean aortic gradient: P < 0.001, regurgitant fraction: P = 0.009). Conclusion: A single {sup 11}C-acetate PET yields accurate and automated MEE results on different scanners. MEE might provide an unbiased measurement of the phenotypic response to valvular disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental demonstration of a dispatchable latent heat storage system with aluminum-silicon as a phase change material

In this work, we present the design, construction, and experimental results of a prototype latent heat thermal energy storage system. The prototype consists of a thermal storage tank with 100 kg of the aluminum-silicon eutectic as a phase change material, a valved thermosyphon that controls heat flow from the thermal storage tank to the power block, and thermoelectric generators for conversion of heat to electricity. We tested the prototype over four simulated days, where each day consisted of four phases of operation: charging, discharging, simultaneous charging and discharging, and storage. Our results show three major conclusions. First, the thermal energy storage system was able to receive and distribute heat with small temperature gradients - less than 5 degrees C throughout the thermal storage tank. Second, the valved thermosyphon was able to effectively control heat transfer, demonstrating an on/off thermal conductance ratio of 430. Third, the interfaces between subsystems had small temperature drops: of the ~ 560 degrees C temperature drop from the thermal storage tank to the heat rejection system, ~ 525 degrees C occurred across the power block. This work overcomes the challenges of integrating previously-developed subsystems together, providing a proof-of-concept of this system.

14 SOLAR ENERGY↗

Valvular Abnormalities Detected by Echocardiography in 5-Year Survivors of Childhood Cancer: A Long-Term Follow-Up Study

Purpose: To determine the prevalence of valvular abnormalities after radiation therapy involving the heart region and/or treatment with anthracyclines and to identify associated risk factors in a large cohort of 5-year childhood cancer survivors (CCS). Methods and Materials: The study cohort consisted of all 626 eligible 5-year CCS diagnosed with childhood cancer in the Emma Children's Hospital/Academic Medical Center between 1966 and 1996 and treated with radiation therapy involving the heart region and/or anthracyclines. We determined the presence of valvular abnormalities according to echocardiograms. Physical radiation dose was converted into the equivalent dose in 2-Gy fractions (EQD{sub 2}). Using multivariable logistic regression analyses, we examined the associations between cancer treatment and valvular abnormalities. Results: We identified 225 mainly mild echocardiographic valvular abnormalities in 169 of 545 CCS (31%) with a cardiac assessment (median follow-up time, 14.9 years [range, 5.1-36.8 years]; median attained age 22.0 years [range, 7.0-49.7 years]). Twenty-four CCS (4.4%) had 31 moderate or higher-graded abnormalities. Most common abnormalities were tricuspid valve disorders (n=119; 21.8%) and mitral valve disorders (n=73; 13.4%). The risk of valvular abnormalities was associated with increasing radiation dose (using EQD{sub 2}) involving the heart region (odds ratio 1.33 per 10 Gy) and the presence of congenital heart disease (odds ratio 3.43). We found no statistically significant evidence that anthracyclines increase the risk. Conclusions: Almost one-third of CCS treated with potentially cardiotoxic therapy had 1 or more asymptomatic, mostly mild valvular abnormalities after a median follow-up of nearly 15 years. The most important risk factors are higher EQD{sub 2} to the heart region and congenital heart disease. Studies with longer follow-up are necessary to investigate the clinical course of asymptomatic valvular abnormalities in CCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preparation of state purified beams of He, Ne, C, N, and O atoms

The production and guiding of ground state and metastable C, N, and O atoms in a two-meter-long, bent magnetic guide are described. Pure beams of metastable He({sup 3}S{sub 1}) and Ne({sup 3}P{sub 2}), and of ground state N({sup 4}S{sub 3/2}) and O({sup 3}P{sub 2}) are obtained using an Even-Lavie valve paired with a dielectric barrier discharge or electron bombardment source. Under these conditions no electronically excited C, N, or O atoms are observed at the exit of the guide. A general valve with electron impact excitation creates, in addition to ground state atoms, electronically excited C({sup 3}P{sub 2}; {sup 1}D{sub 2}) and N({sup 2}D{sub 5/2}; {sup 2}P{sub 3/2}) species. The two experimental conditions are complimentary, demonstrating the usefulness of a magnetic guide in crossed or merged beam experiments such as those described in Henson et al. [Science 338, 234 (2012)] and Jankunas et al. [J. Chem. Phys. 140, 244302 (2014)].

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Facile time-of-flight methods for characterizing pulsed superfluid helium droplet beams

We present two facile time-of-flight (TOF) methods of detecting superfluid helium droplets and droplets with neutral dopants. Without an electron gun and with only a heated filament and pulsed electrodes, the electron impact ionization TOF mass spectrometer can resolve ionized helium clusters such as He{sub 2}{sup +} and He{sub 4}{sup +}, which are signatures of superfluid helium droplets. Without ionizing any helium atoms, multiphoton non-resonant laser ionization of CCl{sub 4} doped in superfluid helium droplets at 266 nm generates complex cluster ions of dopant fragments with helium atoms, including (He){sub n}C{sup +}, (He){sub n}Cl{sup +}, and (He){sub n}CCl{sup +}. Using both methods, we have characterized our cryogenic pulsed valve—the Even-Lavie valve. We have observed a primary pulse with larger helium droplets traveling at a slower speed and a rebound pulse with smaller droplets at a faster speed. In addition, the pickup efficiency of dopant is higher for the primary pulse when the nozzle temperature is higher than 13 K, and the total time duration of the doped droplet pulse is only on the order of 20 μs. These results stress the importance of fast and easy characterization of the droplet beam for sensitive measurements such as electron diffraction of doped droplets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold and intense OH radical beam sources

We present the design and performance of two supersonic radical beam sources: a conventional pinhole-discharge source and a dielectric barrier discharge (DBD) source, both based on the Nijmegen pulsed valve. Both designs have been characterized by discharging water molecules seeded in the rare gases Ar, Kr, or Xe. The resulting OH radicals have been detected by laser-induced fluorescence. The measured OH densities are (3.0 ± 0.6) × 10{sup 11} cm{sup -3} and (1.0 ± 0.5) × 10{sup 11} cm{sup -3} for the pinhole-discharge and DBD sources, respectively. The beam profiles for both radical sources show a relative longitudinal velocity spread of about 10%. The absolute rotational ground state population of the OH beam generated from the pinhole-discharge source has been determined to be more than 98%. The DBD source even produces a rotationally colder OH beam with a population of the ground state exceeding 99%. For the DBD source, addition of O{sub 2} molecules to the gas mixture increases the OH beam density by a factor of about 2.5, improves the DBD valve stability, and allows to tune the mean velocity of the radical beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometrical dependence of spin current absorption into a ferromagnetic nanodot

We have investigated the absorption property of the diffusive pure spin current due to a ferromagnetic nanodot in a laterally configured ferromagnetic/nonmagnetic hybrid nanostructure. The spin absorption in a nano-pillar-based lateral-spin-valve structure was confirmed to increase with increasing the lateral dimension of the ferromagnetic dot. However, the absorption efficiency was smaller than that in a conventional lateral spin valve based on nanowire junctions because the large effective cross section of the two dimensional nonmagnetic film reduces the spin absorption selectivity. We also found that the absorption efficiency of the spin current is significantly enhanced by using a thick ferromagnetic nanodot. This can be understood by taking into account the spin absorption through the side surface of the ferromagnetic dot quantitatively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Real-Time System Identification to Detect Abnormal Operations in a Gas Turbine Cycle

Here, we present a novel online system identification methodology for monitoring the performance of power systems. This methodology was demonstrated in a gas turbine recuperated power plant designed for a hybrid configuration. A 120-kW Garrett microturbine modified to test dynamic control strategies for hybrid power systems designed at the National Energy Technology Laboratory (NETL) was used to implement and validate this online system identification methodology. The main component of this methodology consists of an empirical transfer function model implemented in parallel to the turbine speed operation and the fuel control valve, which can monitor the process response of the gas turbine system while it is operating. During fully closed-loop operations or automated control, the output of the controller, fuel valve position, and the turbine speed measurements were fed for a given period of time to a recursive algorithm that determined the transfer function parameters during the nominal condition. After the new parameters were calculated, they were fed into the transfer function model for online prediction. The turbine speed measurement was compared against the transfer function prediction, and a control logic was implemented to capture when the system operated at nominal or abnormal conditions. To validate the ability to detect abnormal conditions during dynamic operations, drifting in the performance of the gas turbine system was evaluated. A leak in the turbomachinery working fluid was emulated by bleeding 10% of the airflow from the compressor discharge to the atmosphere, and electrical load steps were performed before and after the leak. This tool could detect the leak 7 s after it had occurred, which accounted for a fuel flow increase of approximately 15.8% to maintain the same load and constant turbine speed operations.

algorithms↗

Analytical Solution to the Pneumatic Transient Rod System at ACRR

The ACRR pulse is pneumatically driven by nitrogen in a system of pipes, valves and hoses up to the connection of the pneumatic system and mechanical linkages of the transient rod (TR). The main components of the TR pneumatic system are the regulator, accumulator, solenoid valve and piston-cylinder assembly. The purpose of this analysis is to analyze the flow of nitrogen through the TR pneumatic system in order to develop a motion profile of the piston during the pulse and be able to predict the pressure distributions inside both the cylinder and accumulators. The predicted pressure distributions will be validated against pressure transducer data, while the motion profile will be compared to proximity switch data. By predicting the motion of the piston, pulse timing will be determined and provided to the engineers/operators for verification. The motion profile will provide an acceleration distribution to be used in Razorback to more accurately predict reactivity insertion into the system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Continuing the Evaluation of All-Metal Values for Use in a Tritium Environment

It is desired in tritium gas processing systems to minimize the use of polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in tritium processes are valve components. An all-metal diaphragm valve with no plastic wetting components could be used in certain tritium applications to reduce organic materials in the tritium process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Manifold Integrated Pyrovalve

The Manifold Integrated Pyrovalve (MI-PV) provides a state-of-the-art, low mass, low volume, normally-closed (NC) pyrotechnic isolation valve configuration which is optimized for small free-flier applications. Small scale free-flier (e.g. CubeSat) applications require high pressure fluid isolation valves with leak rates low enough to endure long pad stays, and often have severe mass and volume limitations. The MI-PV utilizes a unique configuration where the shear section and the pyrotechnic ram assembly (PRA) are installed directly into a ported gas manifold, allowing elimination of heavy fluid fittings and connections. This configuration can be readily scaled and adapted to the needs of other long duration missions.

valve pyrovalve pyrotechnic↗

Hydraulic and mixing evaluations for SRS miscible liquid solutions

The hydraulic results demonstrate that pump head pressure of 20 psi recirculates about 5.6 liters/min flowrate through the existing 0.131-inch orifice when a valve connected to NT-41 is closed. In case of the valve open to NT-41, the solution flowrates to Savannah River Site (SRS) tanks, NT-21 and NT-41, are found to be about 0.5 lpm and 5.2 lpm, respectively. The modeling calculations for the mixing operations of miscible fluids contained in the SRS HB-Line tank NT-21 were performed by taking a three-dimensional Computational Fluid Dynamics (CFD) approach. The CFD modeling results were benchmarked against the literature results and the previous SRNL test results to validate the model. Final performance calculations were performed for the nominal case by using the validated model to quantify the mixing time for the HB-Line tank. The results demonstrate that when a pump recirculates a solution volume of 5.7 liters every minute out of the 72-liter tank contents containing two acid solutions of 2.7 M and 0 M concentrations (i.e., water), a minimum mixing time of 1.5 hours is adequate for the tank contents to get the tank contents adequately mixed. In addition, the sensitivity results for the tank contents of 8 M existing solution and 1.5 M incoming species show that the mixing time takes about 2 hours to get the solutions mixed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Benefits of digitalizing and employing simulation to increase plant system performance and ensure compliance with technical specifications - 109

The essential services water system in a BWR nuclear power plant was affected by corrosion, soiling and blockages due to ageing. Those episodes affected safety margins hindering the Technical Specifications compliance during periodic system testing. Tecnatom designed, implemented and tested a design modification for the on-line monitoring of this system by integrating it in the existing Digital Control System (DCS). Key system parameters were acquired in real time to be displayed in the Human System Interface, used in performing calculations and stored their historical evolution. The objective was to optimize monitoring and surveillance of the essential service water system. Furthermore, Tecnatom developed an engineering simulator ('What if' simulator) consisting of a hydraulic model of the system. This simulator takes as inputs each heat exchanger performance parameters from the plant DCS, allows the user to change the essential services water system configuration (valves position, UHS level...) and calculates theoretical process values predicting the system real behavior. In a second stage, more system instruments were wired to the DCS for Technical Specifications compliance automatic surveillance regarding opening and closing times of system valves. Operating experience shows important benefits after the digitalization. It enhances on-line information of system operation and automates calculation of load loss factor of each heat exchanger. It eases the evaluation of blockages and soiling in the system allowing optimization of cleaning proceedings. System Surveillance Requirements and Test Requirements reports have been automated optimizing the operation workload. The simulator use enables to identify optimal system configuration increasing safety margins of the system and ensuring Technical Specifications fulfillment. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Failure Diagnosis for the Holdup Tank System via ISFA

This paper discusses the use of the integrated system failure analysis (ISFA) technique for fault diagnosis for the holdup tank system. ISFA is a simulation-based, qualitative and integrated approach used to study fault propagation in systems containing both hardware and software subsystems. The holdup tank system consists of a tank containing a fluid whose level is controlled by an inlet valve and an outlet valve. We introduce the component and functional models of the system, quantify the main parameters and simulate possible failure-propagation paths based on the fault propagation approach, ISFA. The results show that most component failures in the holdup tank system can be identified clearly and that ISFA is viable as a technique for fault diagnosis. Since ISFA is a qualitative technique that can be used in the very early stages of system design, this case study provides indications that it can be used early to study design aspects that relate to robustness and fault tolerance. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multifunctional Optoelectronic-Spintronic Device Based on Hybrid Organometal Trihalide Perovskites

A novel “hybrid” optoelectronic–spintronic (O-S) device that contains an organometal trihalide perovskite (OTP)-based solar cell or light-emitting diode coupled to an inorganic spin valve is presented. The synergy between the OTP and spin valve components results in two new functionalities: nonlinear magnetophotoconductivity and hysteretic magnetoelectroluminescence.

36 MATERIALS SCIENCE↗

First-Principles Quantum Transport Modeling of Spin-Transfer and Spin-Orbit Torques in Magnetic Multilayers

A unified approach for computing (i) spin-transfer torque in magnetic trilayers like spin valve and magnetic tunnel junction, where injected charge current flows perpendicularly to interfaces, and (ii) spin-orbit torque in magnetic bilayers of the type ferromagnet/spin-orbit-coupled material, where injected charge current flows parallel to the interface, was reviewed. The experimentally explored and technologically relevant spin-orbit-coupled materials include 5d heavy metals, topological insulators, Weyl semimetals, and transition metal dichalcogenides. This approach requires to construct the torque operator for a given Hamiltonian of the device and the steady-state nonequilibrium density matrix, where the latter is expressed in terms of the nonequilibrium Green’s functions and split into three contributions. Tracing these contributions with the torque operator automatically yields field-like and damping-like components of spin-transfer torque or spin-orbit torque vector, which is particularly advantageous for spin-orbit torque where the direction of these components depends on the unknown-in-advance orientation of the current-driven nonequilibrium spin density in the presence of spin-orbit coupling. Illustrative examples are provided by computing spin-transfer torque in a one-dimensional toy model of a magnetic tunnel junction and realistic Co/Cu/Co spin valve, both of which are described by first-principles Hamiltonians obtained from noncollinear density functional theory calculations, as well as by computing spin-orbit torque in a ferromagnetic layer described by a tight-binding Hamiltonian which includes spin-orbit proximity effect within ferromagnetic monolayers assumed to be generated by the adjacent monolayer transition metal dichalcogenide. In addition, it is shown here how spin-orbit proximity effect, quantified by computing (via first-principles retarded Green’s function) spectral functions and spin textures on monolayers of realistic ferromagnetic material like Co in contact with heavy metal or monolayer transition metal dichalcogenide, can be tailored to enhance the magnitude of spin-orbit torque. Furthermore, errors made in the calculation of spin-transfer torque are quantified when using Hamiltonian from collinear density functional theory, with rigidly rotated magnetic moments to create noncollinear magnetization configurations, instead of proper (but computationally more expensive) self-consistent Hamiltonian obtained from noncollinear density functional theory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗