Resilient and Corrosion-Proof Rolling Element Bearings Made from Superelastic Ni-Ti Alloys for Aerospace Mechanism Applications

Mechanical components (bearings, gears, mechanisms) typically utilize hard materials to minimize wear and attain long life. In such components, heavily loaded contact points (e.g., meshing gear teeth, bearing ball-raceway contacts) experience high contact stresses. The combination of high hardness, heavy loads and high elastic modulus often leads to damaging contact stress. In addition, mechanical component materials, such as tool steel or silicon nitride exhibit limited recoverable strain (typically less than 1 percent). These material attributes can lead to Brinell damage (e.g., denting) particularly during transient overload events such as shock impacts that occur during the launching of space vehicles or the landing of aircraft. In this paper, a superelastic alloy, 60NiTi, is considered for rolling element bearing applications. A series of Rockwell and Brinell hardness, compressive strength, fatigue and tribology tests are conducted and reported. The combination of high hardness, moderate elastic modulus, large recoverable strain, low density, and intrinsic corrosion immunity provide a path to bearings largely impervious to shock load damage. It is anticipated that bearings and components made from alloys with such attributes can alleviate many problems encountered in advanced aerospace applications.

DellaCorte, Christopher↗

Engine Performance and Health Monitoring Models Using Steady State and Transient Prediction Methods

This lecture note discusses the role of computer modelling in the design, development, and validation of a performance monitoring system. The basic requirements of an engine health monitoring system are discussed in the context of the user environment. A form of model based on stage characteristics provides the basis for describing engine measurements. Faults are modelled in accordance with empirical data obtained from tests conducted at the stage level. The model is used to investigate various parameters that provide unambiguous identification of the fault in question. Fault libraries have been developed for field use.

B D MacIsaac↗

Parameter identification of aeroelastic modes of rotary wings from transient time histories

A novel moving-block technique is presented for parameter-identification tasks concerning the aeroelastic modes of rotary wings, using a least-squares solver in the time domain to estimate dampings and eigenvector components. The least-squares moving-block (LSMB) technique is shown to yield superior estimates to those of the previous moving-block technique for four different analytical test cases. An additional advantage of the LSMB approach is its ability to estimate eigenvector components with good accuracy; this feature is useful in assessing the coupling of the different modes. The method can also be used to perform periodic modal identification, and is applicable to experimental data for the extraction of modal information.

Amrani, Ahmed Omar↗

Preliminary test data using the MOS DRO with Si:In detector material

The initial testing performed on the Hughes Metal Oxide Semiconductor Direct Readout (MOS DRO) with a Si:In extrinsic infrared array is described. The testing to date was of a screening nature and the results are primarily qualitative rather than quantitative. At a later date the performance optimization phase will be initiated. An encouraging result is that this response is strongly dependent on the detector temperature, to the extent that thermal transients introduced during the chip readout will affect the performance. A responsivity of 1 A/W at 2.2 microns with a bias of 15 volts, which is well below what is optimum bias, was obtained.

Fowler, A. M.↗

Magnetoplasma sheath waves on a conducting tether in the ionosphere with applications to EMI propagation on large space structures

A recent space experiment confirmed sheath-wave propagation of a kilometer-long insulated wire in the ionosphere, oriented parallel to the Earth's magnetic field. This space tether experiment, Oedipus-A, showed a sheath-wave passband up to about 2 MHz and a phase velocity somewhat slower than the velocity of light in a vacuum, and also demonstrated both ease of wave excitation and low attenuation. The evidence suggests that, on any large structure in low Earth orbit, transient or continuous wave electromagnetic interference, once generated, could propagate over the structure via sheath waves, producing unwanted signal levels much higher than in the absence of the ambient plasma medium. Consequently, there is a need for a review of both electromagnetic interference/electromagnetic compatibility standards and ground test procedures as they apply to large structures in low Earth orbit.

Balmain, K. G.↗

Star tracker operation in a high density proton field

Algorithms that reject transient signals due to proton effects on charge coupled device (CCD) sensors have been implemented in the HDOS ASTRA-l Star Trackers to be flown on the TOPEX mission scheduled for launch in July 1992. A unique technique for simulating a proton-rich environment to test trackers is described, as well as the test results obtained. Solar flares or an orbit that passes through the South Atlantic Anomaly can subject the vehicle to very high proton flux levels. There are three ways in which spurious proton generated signals can impact tracker performance: the many false signals can prevent or extend the time to acquire a star; a proton-generated signal can compromise the accuracy of the star's reported magnitude and position; and the tracked star can be lost, requiring reacquisition. Tests simulating a proton-rich environment were performed on two ASTRA-1 Star Trackers utilizing these new algorithms. There were no false acquisitions, no lost stars, and a significant reduction in reported position errors due to these improvements.

Miklus, Kenneth J.↗

Transient Finite Element Analyses Developed to Model Fan Containment Impact Events

Research is underway to establish an increased level of confidence in existing numerical techniques for predicting transient behavior when the fan of a jet engine is released and impacts the fan containment system. To evaluate the predictive accuracy that can currently be obtained, researchers at the NASA Lewis Research Center used the DYNA 3D computer code to simulate large-scale subcomponent impact tests that were conducted at the University of Dayton Research Institute (UDRI) Impact Physics Lab. In these tests, 20- by 40-in. flat metal panels, contoured to the shape of a typical fan case, were impacted by the root section of a fan blade. The panels were oriented at an angle to the path of the projectile that would simulate the conditions in an actual blade-out event. The metal panels were modeled in DYNA 3D using a kinematic hardening model with the strain rate dependence of the yield stress governed by the Cowper-Simons rule. Failure was governed by the effective plastic strain criterion. The model of the fan blade and case just after impact is shown. By varying the maximum effective plastic strain, we obtained good qualitative agreement between the model and the experiments. Both the velocity required to penetrate the case and the deflection during impact compared well. This indicates that the failure criterion and constitutive model may be appropriate, but for DYNA 3D to be useful as a predictive tool, methods to determine accurate model parameters must be established. Simple methods for measuring model parameters are currently being developed. In addition, alternative constitutive models and failure criteria are being investigated.

Pereira, J. Michael↗

Nitrogen Oxides in the Global Upper Troposphere: Interpreting Cloud-Sliced NO2 Observations from the OMI Satellite Instrument

Nitrogen oxides (NOx≡NO+NO2) in the upper troposphere (UT) have a large impact on global tropospheric ozone and OH (the main atmospheric oxidant). New cloud-sliced observations of UT NO2 at 450–280 hPa (∼6–9 km) from the Ozone Monitoring Instrument (OMI) produced by NASA and the Royal Netherlands Meteorological Institute (KNMI) provide global coverage to test our understanding of the factors controlling UT NOx. We find that these products offer useful information when averaged over coarse scales (20°×32°, seasonal), and that the NASA product is more consistent with aircraft observations of UT NO2. Correlation with Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) satellite observations of lightning flash frequencies suggests that lightning is the dominant source of NOx to the upper troposphere except for extratropical latitudes in winter. The NO2 background in the absence of lightning is 10–20 pptv. We infer a global mean NOx yield of 280±80 moles per lightning flash, with no significant difference between the tropics and midlatitudes, and a global lightning NOx source of 5.9±1.7 Tg N a(exp −1). There is indication that the NOx yield per flash increases with lightning flash footprint and with flash energy.

Marais, Eloise A.↗

Simulations of Zero Boiloff, Densification, and Solidification in a Large-Scale Liquid Hydrogen Tank

The current research utilizes an Energy of Fluid (EOF) approach to develop a finite volume-based Computation Fluid Dynamic (CFD) model to create a benchmark simulation of the densification of liquid hydrogen (LH2) in an experimental Integrated Refrigeration and Storage (IRAS) tank at the Kennedy Space Center (KSC). The computational code will incorporate the FLUENT pressure-based model with User Defined Functions (UDF) to implement the EOF model. The enhanced model will solve the energy equation in terms of internal energy and provide temperature and pressure calculations for a given tank geometry. Specifically, a convection term will be added to an already existing code for a more accurate simulation of LH2 densification. However, currently the research focuses on utilizing User Defined Scalars (UDS) with FLUENT to show the built-in solvers are as accurate as the written UDS. This will reduce the computational time down significantly by utilizing an already built in solver for the momentum equation. A custom UDF has been written to solve transient and steady state conduction, and results obtained using the UDF agree with results obtained using the built-in FLUENT solver. Currently, a convection UDF is being added and will be verified using known solutions for solidification and validated with the experimental results from the Cryogenics Test Laboratory (CTL) at KSC for the IRAS densification process.

Colin Philip Mahony↗

Transient shutdown analysis of low-temperature thermal diodes

The various thermal diodes available for use in cryogenic systems are described. Two diode types, liquid-trap and liquid-blockage diodes, were considered to be the most attractive, and thermal models were constructed to predict their behavior in the reverse mode. The diodes, which are of similar size and throughput, were also examined experimentally in a parallel test setup under nominally identical conditions. Their characteristics were ascertained in terms of forward-mode and reverse-mode conductances, shutdown times and energies, and recovery to forward-mode operation with ethane as the working fluid in the temperature range 170 K to 220 K. Results show that the liquid-blockage diode is the quicker of the two diodes to shut down from the forward mode (8 min as opposed to 10 min). However, the liquid-blockage diode has a larger reverse-mode conductance which results in a greater overall evaporator temperature rise. The importance of the relative size and heat inputs to the condenser/reservoir configuration of the liquid-blockage diode and the evaporator trap configuration for the liquid-trap diode are demonstrated. Also included are data which show the susceptibility of the diodes to recovery to forward-mode operation. Guidelines for the choice of a particular diode for an actual application are given.

Williams, R. J.↗

An experimental investigation with artificial sunlight of a solar hot-water heater

Thermal performance measurements were made of a commercial solar hot-water heater in a solar simulator. The objective of the test was to determine basic performance characteristics of a traditional type of flat-plate collector, with and without side reflectors (to increase the solar flux). Due to the fact that collector testing in the solar simulator permits control of the variables that affect collector performance, it was possible to obtain information on each of the following: (1) the effect of flow and incidence angle on the efficiency of a flat-plate collector (but only without side reflectors), (2) transient performance under flow and nonflow conditions, (3) the effectiveness of reflectors in increasing collector efficiency for a zero radiation angle at fluid temperatures required for solar air conditioning, and (4) the limits of applicability of a collector efficiency correlation based on the Hottel-Whillier equation (1958).

Simon, F. F.↗

Mixed time integration methods for transient thermal analysis of structures

The computational methods used to predict and optimize the thermal structural behavior of aerospace vehicle structures are reviewed. In general, two classes of algorithms, implicit and explicit, are used in transient thermal analysis of structures. Each of these two methods has its own merits. Due to the different time scales of the mechanical and thermal responses, the selection of a time integration method can be a different yet critical factor in the efficient solution of such problems. Therefore mixed time integration methods for transient thermal analysis of structures are being developed. The computer implementation aspects and numerical evaluation of these mixed time implicit-explicit algorithms in thermal analysis of structures are presented. A computationally useful method of estimating the critical time step for linear quadrilateral element is also given. Numerical tests confirm the stability criterion and accuracy characteristics of the methods. The superiority of these mixed time methods to the fully implicit method or the fully explicit method is also demonstrated.

Liu, W. K.↗

Low-temperature heat pipe experiment package (HEPP) for LDEF (S1001)

The principal objectives of the experiment are to determine zero-g start-up performance for conventional and diode low temperature heat pipes, to evaluate heat pipe performance in zero-g for an extended period of time, to determine zero-g transport capability of each heat pipe, and to determine diode operation, including forward conductance, turndown ratio, and transient behavior. Two heat pipes, a fixed conductance transporter heat pipe and a thermal diode heat pipe, are coupled with a radiant cooler system. Both pipes are charged with ethane. Also integrated with the radiator is a phase change material (PCM) canister which provides temperature stability during transport tests. N-heptane, which has a melting/freezing point of 182 K, is used as the PCM. The high heat capacity (28 W-hr of latent heat) provided by the canister permits high power heat pipe testing at constant temperature.

Mcintosh, R., Jr.↗

A hybrid transfinite element approach for nonlinear transient thermal analysis

A new computational approach for transient nonlinear thermal analysis of structures is proposed. It is a hybrid approach which combines the modeling versatility of contemporary finite elements in conjunction with transform methods and classical Bubnov-Galerkin schemes. The present study is limited to nonlinearities due to temperature-dependent thermophysical properties. Numerical test cases attest to the basic capabilities and therein validate the transfinite element approach by means of comparisons with conventional finite element schemes and/or available solutions.

Tamma, Kumar K.↗

Containerless processing at high temperatures using acoustic levitation

Advanced techniques are presented which facilitate the development of inert or reducing atmospheres in excess of 2000 K in order to improve processing of containerless capabilities at higher temperatures and to provide more contamination-free environments. Recent testing, in the laboratory and aboard the NASA KC-135 aircraft, of a high-temperature acoustic positioner demonstrated the effectiveness of a specimen motion damping system and of specimen spin control. It is found that stable positioning can be achieved under ambient and heated conditions, including the transient states of heat-up and cool-down. An incorporated high-temperature levitator was found capable of processing specimens of up to 6-mm diameter in a high-purity environment without the contaminating effects of a container at high temperatures and with relative quiescence.

Rey, C. A.↗

PASP, a high voltage array/plasma interaction experiment

The author discusses the photovoltaic array space power (PASP) experiment, which is designed to obtain data on the interaction between high-voltage photovoltaic arrays and the polar, low-earth plasma environment. Up to six small test arrays (three each of planar and concentrator designs) can be voltage biased over a range of +/- 500 V. During the bias voltage sequence, the array current leakage is measured and array arc events are monitored. If any arcing occurs the arc characteristics will be measured by a transient pulse monitor. An emitter is included to allow voltage bias to be applied to a plasma-charged or uncharged spacecraft. Similarly, the frames of the concentrator arrays can be left floating or can be tied to the negative array terminal. An environmental data scan is made before each bias voltage sequence. This scan collects information on the plasma, array-current-versus-voltage curves, and neutral particle partial pressure. The requirement for high voltages created problems which were met by circuit isolation and logical fault protection.

Burger, Dale R.↗

Associated with aerospace vehicles development of methodologies for the estimation of thermal properties

Thermal stress analyses are an important aspect in the development of aerospace vehicles at NASA-LaRC. These analyses require knowledge of the temperature distributions within the vehicle structures which consequently necessitates the need for accurate thermal property data. The overall goal of this ongoing research effort is to develop methodologies for the estimation of the thermal property data needed to describe the temperature responses of these complex structures. The research strategy undertaken utilizes a building block approach. The idea here is to first focus on the development of property estimation methodologies for relatively simple conditions, such as isotropic materials at constant temperatures, and then systematically modify the technique for the analysis of more and more complex systems, such as anisotropic multi-component systems. The estimation methodology utilized is a statistically based method which incorporates experimental data and a mathematical model of the system. Several aspects of this overall research effort were investigated during the time of the ASEE summer program. One important aspect involved the calibration of the estimation procedure for the estimation of the thermal properties through the thickness of a standard material. Transient experiments were conducted using a Pyrex standard at various temperatures, and then the thermal properties (thermal conductivity and volumetric heat capacity) were estimated at each temperature. Confidence regions for the estimated values were also determined. These results were then compared to documented values. Another set of experimental tests were conducted on carbon composite samples at different temperatures. Again, the thermal properties were estimated for each temperature, and the results were compared with values obtained using another technique. In both sets of experiments, a 10-15 percent off-set between the estimated values and the previously determined values was found. Another effort was related to the development of the experimental techniques. Initial experiments required a resistance heater placed between two samples. The design was modified such that the heater was placed on the surface of only one sample, as would be necessary in the analysis of built up structures. Experiments using the modified technique were conducted on the composite sample used previously at different temperatures. The results were within 5 percent of those found using two samples. Finally, an initial heat transfer analysis, including conduction, convection and radiation components, was completed on a titanium sandwich structural sample. Experiments utilizing this sample are currently being designed and will be used to first estimate the material's effective thermal conductivity and later to determine the properties associated with each individual heat transfer component.

Scott, Elaine P.↗

Magnetic Field Effects on Convection and Solidification in Normal and Microgravity

It has been well understood that convective flows induced by g-jitter forces associated with spacecraft are responsible for defects formation and irregularity in product quality during melt growth of single crystals in microgravity. This research is concerned about numerical simulations and experimental measurements for the purpose of developing a fundamental understanding of the g-jitter induced fluid flows and their effects on solidification in microgravity with and without the presence of additional damping forces that are derived from the applied DC magnetic fields. The numerical models include both 2-D and 3-D transient fluid flow, heat transfer, mass transfer and solidification under the combined action of g-jitter and magnetic fields. Numerical simulations using both the 2-D and 3-D models are conducted for both idealized, synthesized and real g-jitter forces, and 2-D simulations are tested against the experimental measurements taken on the thermal oscillator. 2-D solidification models have also been developed and simulations are conducted. Results show that the numerical model predictions compare well with the measurements. Analysis of these results illustrates that an applied magnetic field can have a drastic influence on the convective flows induced by g-jitter and can be particularly useful to suppress the effects resulting from the spiking of g-jitter signatures, which are considered the most detrimental effects on quality of crystals grown in space. Work in progress includes developing 3-D numerical models for solidification phenomena with the presence of both g-jitter and magnetic fields and measurements of flow fluid and its effect on solidification in both transparent fluid and low melting point melts to verify numerical predictions.

Li, Ben Q.↗