Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Time-Resolved OH-PLIF Assessment of Deflagrations Levels in a CH4-O2 Rotating Detonation Rocket Combustor

The parasitic loss incurred by deflagrative pre-burning is considered to be one of the key challenges to the effective implementation of rotating detonation engine (RDE) systems. Thus far, there have been relatively limited high fidelity, spatio-temporally resolved measurements of the pre-burning process as a function of the reactant conditions and composition within an RDE. In this work, simultaneous high-repetition-rate broadband OH* chemiluminescence and OH planar laser-induced fluorescence (PLIF) imaging are employed to investigate deflagrative burning dynamics in a fully optically accessible CH4-O2 RDE as compared to a H2-air systems under the same conditions. A custom-built optical parametric oscillator (OPO) is coupled with a high-repetition-rate burst-mode laser to generate the 284 nm source for the excitation of the Q1(9) transition of the OH radical. Significant deflagrative burning is observed throughout the chamber as a consequence of the oxygen-rich environment. Trailing wave systems that consume unburned reactants in the region immediately following the primary detonation wave are observed. The formation of a product gas recirculation zone that entrains and combusts incoming reactants is observed, and quantitative analysis is performed to gain valuable insight into deflagration characteristics. At an oxidizer mass flux of Gox ≈ 350kg/m2/s, it is found that the levels of pre-wave burning in CH4-O2 are a factor of ∼2-3 times higher than in H2-air in the region directly ahead of the detonation wave at a global equivalence ratio Φ ≈ 1.0. This study highlights the key roles of ignition delay and turbulent mixing of the combustion product and reactant fields on the levels of pre-burning and establishes a methodology for further investigation, such as for the effects of various RDE inlet configurations.

Propulsion↗

First experimental demonstration of time-resolved X-ray measurements with next-generation fast-timing MCP-PMT

We report the first successful time-resolved X-ray measurements at the APS 10-ID-B beamline by coupling ultrafast scintillators with photodetectors. Multiple scintillator and sensor pairs (LYSO, plastic scintillator, dynode PMTs, MCP-PMT), as well as a standalone detector (diamond), were tested to demonstrate the time-resolved measurements using hard X-rays at energies of 20 keV and above. The experimental results show that a number of choices exist for time-resolved high-energy X-ray beam measurement. Notably, by gating the photocathode, the Argonne fabricated fast-timing microchannel plate photomultiplier and LYSO crystal pair achieved fast signal detection with a rise time of 6 ns and a decay time of 33 ns. Furthermore, these experiments pave the way towards ultrafast imaging technologies using hard X-rays for many applications.

36 MATERIALS SCIENCE↗

Thermal stability of nitrogen in nitrided HfSiO{sub 2}/SiO{sub 2}/Si(001) ultrathin films

We report on the stability under rapid thermal annealing (RTA) of the nitrogen depth profile in nitrided HfO{sub 2}/SiO{sub 2}/Si[001] and Hf{sub 0.8}Si{sub 0.2}O{sub 2}/SiO{sub 2}/Si[001] dielectric stacks. High resolution x-ray photoelectron spectroscopy (XPS) data indicate that the chemical component of nitrogen associated with the hafnium layer (binding energy of 396.7 eV) decreases considerably upon RTA. This was accompanied by a corresponding increase in the nitrogen component associated with silicon oxynitride (binding energy of 397.5 eV). A self-consistent analysis of the angle resolved XPS data indicated that the total amount of nitrogen in the film remains constant, suggesting that RTA causes an exchange of nitrogen between the hafnium and silicon layers. Transmission electron microscopy images show crystallization of the hafnium layer upon RTA, which is consistent with the loss of nitrogen. Data from time of flight secondary ion mass spectroscopy were consistent with the change in the nitrogen profile caused by RTA.

36 MATERIALS SCIENCE↗

DUST PRODUCTION AND PARTICLE ACCELERATION IN SUPERNOVA 1987A REVEALED WITH ALMA

Supernova (SN) explosions are crucial engines driving the evolution of galaxies by shock heating gas, increasing the metallicity, creating dust, and accelerating energetic particles. In 2012 we used the Atacama Large Millimeter/Submillimeter Array to observe SN 1987A, one of the best-observed supernovae since the invention of the telescope. We present spatially resolved images at 450 μm, 870 μm, 1.4 mm, and 2.8 mm, an important transition wavelength range. Longer wavelength emission is dominated by synchrotron radiation from shock-accelerated particles, shorter wavelengths by emission from the largest mass of dust measured in a supernova remnant (>0.2 M {sub ☉}). For the first time we show unambiguously that this dust has formed in the inner ejecta (the cold remnants of the exploded star's core). The dust emission is concentrated at the center of the remnant, so the dust has not yet been affected by the shocks. If a significant fraction survives, and if SN 1987A is typical, supernovae are important cosmological dust producers.

79 ASTRONOMY AND ASTROPHYSICS↗

The symmetries of image formation by scattering II Applications

We show that the symmetries of image formation by scattering enable graph-theoretic manifold-embedding techniques to extract structural and timing information from simulated and experimental snapshots at extremely low signal. The approach constitutes a physically-based, computationally efficient, and noise-robust route to analyzing the large and varied datasets generated by existing and emerging methods for studying structure and dynamics by scattering. We demonstrate three-dimensional structure recovery from X-ray diffraction and cryo-electron microscope image snapshots of unknown orientation, the latter at 12 times lower dose than currently in use. We also show that ultra-low-signal, random sightings of dynamically evolving systems can be sequenced into high quality movies to reveal their evolution. Our approach offers a route to recovering timing information in time-resolved experiments, and extracting 3D movies from two-dimensional random sightings of dynamic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

O {sub VI} emission imaging of a galaxy with the hubble space telescope: a warm gas halo surrounding the intense starburst SDSS J115630.63+500822.1

We report results from a new Hubble Space Telescope campaign that targets the O vi λλ1032,1038 Å doublet in emission around intensely star-forming galaxies. The program aims to characterize the energy balance in starburst galaxies and gas cooling in the difficult-to-map coronal temperature regime of 2--5×10{sup 5} K. We present the first resolved image of gas emission in the O vi line. Our target, SDSS J115630.63+500822.1, is very compact in the continuum but displays O vi emission to radii of 23 kpc. The surface brightness profile is well fit by an exponential with a scale length of 7.5 kpc. This is 10 times the size of the photoionized gas, and we estimate that about 1/6 the total O vi luminosity comes from resonantly scattered continuum radiation. Spectroscopy—which closely resembles a stacked sample of archival spectra—confirms the O vi emission, and determines the column density and outflow velocity from blueshifted absorption. The combination of measurements enables a large number of calculations with few assumptions. The O vi regions fill only ∼10{sup −3} of the volume. By comparing the cooling time with the cloud sound-crossing time, the cooling distance with the size, and the pressure in the O vi and nebular gas, we conclude that the O vi-bearing gas cannot have been lifted to the scale height at this temperature, and must be cooling in situ through this coronal temperature regime. The coronal phase contains ∼1% of the ionized mass, and its kinetic energy at a given instant is ∼1% of the budget set by supernova feedback. However, a much larger amount of the gas must have cooled through this phase during the star formation episode. The outflow exceeds the escape velocity and the gas may become unbound, but it will recombine before it escapes and become visible to Lyman (and O i) spectroscopy. The mapping of this gas represents a crucial step in further constraining galaxy formation scenarios and guiding the development of future astronomical satellites.

79 ASTRONOMY AND ASTROPHYSICS↗

Dust Production and Particle Acceleration in Supernova 1987A Revealed with ALMA

Supernova (SN) explosions are crucial engines driving the evolution of galaxies by shock heating gas, increasing the metallicity, creating dust, and accelerating energetic particles. In 2012 we used the Atacama Large Millimeter/ Submillimeter Array to observe SN1987A, one of the best-observed supernovae since the invention of the telescope. We present spatially resolved images at 450 μm, 870 μm, 1.4 mm, and 2.8 mm, an important transition wavelength range. Longer wavelength emission is dominated by synchrotron radiation from shock-accelerated particles, shorter wavelengths by emission from the largest mass of dust measured in a supernova remnant (>0.2 Solar Mass). For the first time we show unambiguously that this dust has formed in the inner ejecta (the cold remnants of the exploded star's core). The dust emission is concentrated at the center of the remnant, so the dust has not yet been affected by the shocks. If a significant fraction survives, and if SN 1987A is typical, supernovae are important cosmological dust producers.

Particle↗

Acquisition and Processing Considerations for Infrared Images of Rotating Turbine Blades

Abstract As designers aim to increase efficiency in gas turbines for aircraft propulsion and power generation, spatially resolved experimental measurements are needed to validate computational models and compare improvement gains of new cooling designs. Infrared (IR) thermography is one such method for obtaining spatially resolved temperature measurements. As technological advances in thermal detectors enable faster integration times, surface temperature measurements of rotating turbine blades become possible to capture including the smallest features. This paper outlines opportunities enabled by the latest IR detector technologies for capturing spatially resolved rotating blade temperatures, while also addressing some of the challenges of implementing IR for turbine rigs such as the one in the Steady Thermal Aero Research Turbine (START) Laboratory. This paper documents critical steps in achieving accurate measurements including calibration, integration times, spatial noise, and motion blur. From these results, recommendations are provided for achieving accurate IR measurements collected in a rotating turbine facility to study film cooling.

Engineering↗

Applying a difference ratio method in spin-polarized scanning tunneling microscopy to determine crystalline anisotropies and antiferromagnetic spin alignment in Cr(0 0 1) c(2 $\times$ 2)

Here, we present spin-polarized scanning tunneling microscopy results for 8 micrometer thick, chromium (0 0 1)-oriented thin films deposited using molecular beam epitaxy on MgO(0 0 1) substrates, achieving a smooth, atomically-stepped staircase morphology. The c(2 × 2) surface structure of the Cr(0 0 1) surface was found via atomically-resolved scanning tunneling microscopy images and dI/dV spectroscopy. A practical method of interpreting spin-polarized scanning tunneling microscopy dI/dV images was developed and applied to the c(2 × 2) Cr(0 0 1) surface structure. A 180° spin reversal between atomic layers, characteristic of a topological, layer-wise antiferromagnetic spin structure, was quantitatively verified. In addition, the spin anisotropy directions for 3 different antiferromagnetic, atomic staircase domains occurring on the c(2 × 2) surface were quantitatively determined to coincide with the [1 0 0], [0 1 0], and [1 1 0] crystallographic axes of chromium

36 MATERIALS SCIENCE↗

Operating organic light-emitting diodes imaged by super-resolution spectroscopy

Super-resolution stimulated emission depletion microscopy is adapted here for materials characterization that would not otherwise be possible. With the example of organic lightemitting diodes (OLEDs), spectral imaging with pixel-by-pixel wavelength discrimination allows us to resolve local-chain environment encoded in the spectral response of the semiconducting polymer, and correlate chain packing with local electroluminescence by using externally applied current as the excitation source. We observe nanoscopic defects that would be unresolvable by traditional microscopy. They are revealed in electroluminescence maps in operating OLEDs with 50 nm spatial resolution. We find that brightest emission comes from regions with more densely packed chains. Conventional microscopy of an operating OLED would lack the resolution needed to discriminate these features, while traditional methods to resolve nanoscale features generally cannot be performed when the device is operating. Furthermore, this points the way towards real-time analysis of materials design principles in devices as they actually operate.

30 DIRECT ENERGY CONVERSION↗

Internal mixing dynamics of Cu/Sn-Pb plasmas produced by femtosecond laser ablation

Chemical imaging applications using Laser Induced Breakdown Spectroscopy (LIBS) involve laser ablation sampling at interfaces or boundaries between materials with different thermophysical and optical properties, leading to the formation of two initially isolated plasmas. The mechanisms of mixing in these plasmas and their direct implications on spectral emission and chemical imaging remain largely unknown. We investigate the mixing dynamics of isolated plasmas produced using femtosecond (fs) laser pulses at the interface between two different model Cu and Sn–Pb samples. Specifically, we study the spatial and temporal mixing dynamics and outer plasma expansion dynamics of the fs plasma components. The time-resolved degree of component mixing, horizontal and vertical expansion, mixing speed, and temperature and electron density of the heterogeneous plasma are characterized. Mixing processes are initiated early on, <100 ns after the laser pulse, and continue taking place until the end of plasma emission persistence at a constant velocity of 10 4 cm/s. In conclusion, these findings demonstrate that proper selection of detection timing parameters and signal collection position are critically important in precise LIBS measurements to ensure that full plasma mixing has taken place and that homogeneous spectral emission is properly detected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-ablation sampling for inductively coupled plasma distance-of-flight mass spectrometry

An inductively coupled plasma distance-of-flight mass spectrometer (ICP-DOFMS) has been coupled with laser-ablation (LA) sample introduction for the elemental analysis of solids. ICP-DOFMS is well suited for the analysis of laser-generated aerosols because it offers both high-speed mass analysis and simultaneous multi-elemental detection. Here, we evaluate the analytical performance of the LA-ICP-DOFMS instrument, equipped with a microchannel plate-based imaging detector, for the measurement of steady-state LA signals, as well as transient signals produced from single LA events. Steady-state detection limits are 1 mg g1, and absolute single-pulse LA detection limits are 200 fg for uranium; the system is shown capable of performing time-resolved single-pulse LA analysis. By leveraging the benefits of simultaneous multi-elemental detection, we also attain a good shot-to-shot reproducibility of 6% relative standard deviation (RSD) and isotope-ratio precision of 0.3% RSD with a 10 s integration time.

Gundlach-Graham, Alexander W.↗

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Measurement of Temperature, Velocity, and Density in Hot Jets Using Rayleigh Scattering

A molecular Rayleigh scattering technique was utilized to measure time-resolved gas temperature, velocity, and density in unseeded gas flows at sampling rates up to 10 kHz. A high power continuous-wave (cw) laser beam was focused at a point in an air flow field and Rayleigh scattered light was collected and fiber-optically transmitted to a Fabry-Perot interferometer for spectral analysis. Photomultipler tubes operated in the photon counting mode allowed high frequency sampling of the total signal level and the circular interference pattern to provide time-resolved density, temperature, and velocity measurements. Mean and rms velocity and temperature, as well as power spectral density calculations, are presented for measurements in a hydrogen-combustor heated jet facility with a 50.8-mm diameter nozzle at the NASA Glenn Research Center (GRC). The Rayleigh measurements are compared with particle image velocimetry data and CFD predictions. This technique is aimed at aeronautics research related to identifying noise sources in free jets, as well as applications in supersonic and hypersonic flows where measurement of flow properties, including mass flux, is required in the presence of shocks and ionization occurrence.

Mielke, Amy F.↗

A SURPRISING DYNAMICAL MASS FOR V773 Tau B

We report on new high-resolution imaging and spectroscopy on the multiple T Tauri star system V773 Tau over the 2003-2009 period. With these data we derive relative astrometry, photometry between the A and B components, and radial velocity (RV) of the A-subsystem components. Combining these new data with previously published astrometry and RVs, we update the relative A-B orbit model. This updated orbit model, the known system distance, and A-subsystem parameters yield a dynamical mass for the B component for the first time. Remarkably, the derived B dynamical mass is in the range 1.7-3.0 M{sub Sun }. This is much higher than previous estimates and suggests that like A, B is also a multiple stellar system. Among these data, spatially resolved spectroscopy provides new insight into the nature of the B component. Similar to A, these near-IR spectra indicate that the dominant source in B is of mid-K spectral type. If B is in fact a multiple star system as suggested by the dynamical mass estimate, the simplest assumption is that B is composed of similar {approx}1.2 M{sub Sun} pre-main-sequence stars in a close (<1 AU) binary system. This inference is supported by line-shape changes in near-IR spectroscopy of B, tentatively interpreted as changing RV among components in V773 Tau B. Relative photometry indicates that B is highly variable in the near-IR. The most likely explanation for this variability is circum-B material resulting in variable line-of-sight extinction. The distribution of this material must be significantly affected by both the putative B multiplicity and the A-B orbit.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron-based X-ray Fluorescence Microscopy as a Technique for Imaging of Elements in Plants

Understanding the distribution of elements within plant tissues is important across a range of fields in plant science. In this review, we examine synchrotron-based X-ray fluorescence microscopy (XFM) as an elemental imaging technique in plant sciences, considering both its historical and current uses as well as discussing emerging approaches. XFM offers several unique capabilities of interest to plant scientists, including in vivo analyses at room temperature and pressure, good detection limits (ca. 1-100 mg/kg), and excellent resolution (down to 50 nm). This has permitted its use in a range of studies, including for functional characterization in molecular biology, examining the distribution of nutrients in food products, understanding movement of foliar fertilizers, investigating the behaviour of engineered nanoparticles, elucidating the toxic effects of metal(loid)s in agronomic plant species, and studying the unique properties of hyperaccumulating plants. We anticipate that continuing technological advances at XFM beamlines will also provide new opportunities moving into the future, such as for high-throughput screening in molecular biology, use of exotic metal tags for protein localization, and for enabling time-resolved, in vivo analyses of living plants. By examining current and potential future applications, we hope to encourage further XFM studies in plant sciences by highlighting the versatility of this approach.

47 OTHER INSTRUMENTATION↗

TIME-RESOLVED EMISSION FROM BRIGHT HOT PIXELS OF AN ACTIVE REGION OBSERVED IN THE EUV BAND WITH SDO/AIA AND MULTI-STRANDED LOOP MODELING

Evidence of small amounts of very hot plasma has been found in active regions and might be an indication of impulsive heating released at spatial scales smaller than the cross-section of a single loop. We investigate the heating and substructure of coronal loops in the core of one such active region by analyzing the light curves in the smallest resolution elements of solar observations in two EUV channels (94 and 335 Å) from the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory. We model the evolution of a bundle of strands heated by a storm of nanoflares by means of a hydrodynamic 0D loop model (EBTEL). The light curves obtained from a random combination of those of single strands are compared to the observed light curves either in a single pixel or in a row of pixels, simultaneously in the two channels, and using two independent methods: an artificial intelligent system (Probabilistic Neural Network) and a simple cross-correlation technique. We explore the space of the parameters to constrain the distribution of the heat pulses, their duration, their spatial size, and, as a feedback on the data, their signatures on the light curves. From both methods the best agreement is obtained for a relatively large population of events (1000) with a short duration (less than 1 minute) and a relatively shallow distribution (power law with index 1.5) in a limited energy range (1.5 decades). The feedback on the data indicates that bumps in the light curves, especially in the 94 Å channel, are signatures of a heating excess that occurred a few minutes before.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-60: Quality Assurance Testing Methods and Customized Phantom for Magnetic Resonance Imaging and Spectroscopy

Purpose: The objectives of this study are to develop an magnetic resonance imaging and spectroscopy (MRI-MRS) fused phantom along with the inserts for metabolite quantification and to conduct quantitative analysis and evaluation of the layered vials of brain-mimicking solution for quality assurance (QA) performance, according to the localization sequence. Methods: The outer cylindrical phantom body is made of acrylic materials. The section other than where the inner vials are located was filled with copper sulfate and diluted with water so as to reduce the T1 relaxation time. Sodium chloride was included to provide conductivity similar to the human body. All measurements of MRI and MRS were made using a 3.0 T scanner (Achiva Tx 3.0 T; Philips Medical Systems, Netherlands). The MRI scan parameters were as follows: (1) spin echo (SE) T1-weighted image: repetition time (TR), 500ms; echo time (TE), 20ms; matrix, 256×256; field of view (FOV), 250mm; gap, 1mm; number of signal averages (NSA), 1; (2) SE T2-weighted image: TR, 2,500 ms; TE, 80 ms; matrix, 256×256; FOV, 250mm; gap, 1mm; NSA, 1; 23 slice images were obtained with slice thickness of 5mm. The water signal of each volume of interest was suppressed by variable pulse power and optimized relaxation delays (VAPOR) applied before the scan. By applying a point-resolved spectroscopy sequence, the MRS scan parameters were as follows: voxel size, 0.8×0.8×0.8 cm{sup 3}; TR, 2,000ms; TE, 35ms; NSA, 128. Results: Using the fused phantom, the results of measuring MRI factors were: geometric distortion, <2% and ±2 mm; image intensity uniformity, 83.09±1.33%; percent-signal ghosting, 0.025±0.004; low-contrast object detectability, 27.85±0.80. In addition, the signal-to-noise ratio of N-acetyl-aspartate was consistently high (42.00±5.66). Conclusion: The MRI-MRS QA factors obtained simultaneously using the phantom can facilitate evaluation of both images and spectra, and provide guidelines for obtaining MRI and MRS QA factors simultaneously. This study was supported by grant (2012-007883 and 2014R1A2A1A10050270) from the Mid-career Researcher Program through the NRF funded by Ministry of Science. In addition, this study was supported by the Industrial R&D of MOTIE/KEIT (10048997, Development of the core technology for integrated therapy devices based on real-time MRI-guided tumor tracking)

60 APPLIED LIFE SCIENCES↗