Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systematic Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Design improvement of the three-beam detector towards a precise long-range 6-degree of freedom motion sensor system

This paper presents performance enhancement of the three beam detector through design improvement based on the error analysis. The three-beam detector is a novel sensor system that measures six motions (i.e., 3 translations and 3 rotations) of a remote object with high accuracy by implementing three laser distance sensors and a vision sensor. In this paper, finite element analysis and parameter analysis are applied to the three-beam detector to analyze its structural frames and sensor configuration, respectively, in terms of sensing error. By virtue of such a systematic, quantitative error analysis, this research has successfully improved the performance of the three-beam detector and thoroughly validated through field tests that it can detect the 6-degree of freedom motions of a remote target at 30 m with an accuracy of 1.51 mm and 0.18° and precision of 0.38 mm and 0.13°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BK using HYP-smeared staggered fermions in Nf = 2 + 1 unquenched QCD

We present results for the kaon mixing parameter B{sub K} calculated using HYP (hypercubic fat link)-smeared improved staggered fermions on the asqtad lattices generated by the MILC collaboration. We use three lattice spacings (a{approx} 0.12, 0.09 and 0.06 fm), ten different valence-quark masses (m {approx} m{sub s}/10-m{sub s}), and several light sea-quark masses in order to control the continuum and chiral extrapolations. We derive the next-to-leading order staggered chiral perturbation theory (SChPT) results necessary to fit our data, and use these results to do extrapolations based both on SU(2) and SU(3) SChPT. The SU(2) fitting is particularly straightforward because parameters related to taste breaking and matching errors appear only at next-to-next-to-leading order. We match to the continuum renormalization scheme [naive dimensional regularization (NDR)] using one-loop perturbation theory. Our final result is from the SU(2) analysis, with the SU(3) result providing a (less accurate) cross check. We find B{sub K}(NDR, {mu} = 2 GeV) = 0.529 {+-} 0.009 {+-} 0.032 and B{sub K} = B{sub K}(RGI) = 0.724 {+-} 0.012 {+-} 0.043, where the first error is statistical and the second systematic. The error is dominated by the truncation error in the matching factor. Our results are consistent with those obtained using valence domain-wall fermions on lattices generated with asqtad or domain-wall sea quarks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Addressing a systematic bias in carbon dioxide flux measurements with the EC150 and the IRGASON open-path gas analyzers

Across a global network of eddy covariance flux towers, two relatively new open-path infrared gas analyzers (IRGAs), the IRGASON and the EC150, are increasingly used to measure net carbon dioxide (CO 2 ) fluxes (F c_OP ). Differences in net CO 2 fluxes derived from open- and closed-path IRGAs in general remain poorly constrained. In particular, the performance of the IRGASON and the EC150 for measuring F c_OP has not been characterized yet. These IRGAs measure CO 2 absorption, which is scaled with air temperature and pressure before converting it to instantaneous CO 2 density. This sensor-internal conversion is based on a slow-response thermistor air temperature measurement. In this paper, we test if the high-frequency temperature attenuation causes selectively systematic F c_OP errors that scale with kinematic temperature fluxes. First, we examine the relationship between wintertime F c_OP and kinematic temperature fluxes for eight northern ecosystems. Second, we investigate how residuals between F c_OP and CO 2 fluxes from co-located closed-path IRGAs (F C_CP ) are related to kinematic temperature fluxes for three different ecosystem types (i.e., boreal forest, grassland, and irrigated cropland). We find that kinematic temperature fluxes, but not mean ambient air temperatures or CO 2 flux regime, consistently determine the absolute magnitude of F c_OP errors. This selectively systematic bias causes the most pronounced relative F c_OP errors to occur when “true” CO 2 fluxes are low and kinematic temperature fluxes are high (e.g., northern ecosystems during the winter). The smallest relative errors occur during periods with large “true” CO 2 fluxes and low kinematic temperature fluxes. To address this bias, we replace the slow-response air temperature in the absorption-to-CO 2 density conversion with a fast-response air temperature derived from sonic anemometer measurements. The use of the fast-response air temperature improves the agreement between half-hourly F c_OP and F C_CP for all open- versus closed-path IRGA comparisons. Additionally, cumulative F c_OP and F c_CP sums are more comparable as differences drop from 63 %–13 % to 20 %–8 %. Finally, the improved IRGASON and EC150 performance enhances the ability and confidence to synthesize flux measurements across multiple sites including these two relatively new IRGAs.

47 OTHER INSTRUMENTATION↗

Fabrication-conscious neural network based inverse design of single-material variable-index multilayer films

Multilayer films with continuously varying indices for each layer have attracted great deal of attention due to their superior optical, mechanical, and thermal properties. However, difficulties in fabrication have limited their application and study in scientific literature compared to multilayer films with fixed index layers. In this work we propose a neural network based inverse design technique enabled by a differentiable analytical solver for realistic design and fabrication of single material variable-index multilayer films. This approach generates multilayer films with excellent performance under ideal conditions. We furthermore address the issue of how to translate these ideal designs into practical useful devices which will naturally suffer from growth imperfections. By integrating simulated systematic and random errors just as a deposition tool would into the optimization process, we demonstrated that the same neural network that produced the ideal device can be retrained to produce designs compensating for systematic deposition errors. Furthermore, the proposed approach corrects for systematic errors even in the presence of random fabrication imperfections. The results outlined in this paper provide a practical and experimentally viable approach for the design of single material multilayer film stacks for an extremely wide variety of practical applications with high performance.

36 MATERIALS SCIENCE↗

Galaxy–galaxy lensing estimators and their covariance properties

Here, we study the covariance properties of real space correlation function estimators – primarily galaxy–shear correlations, or galaxy–galaxy lensing – using SDSS data for both shear catalogues and lenses (specifically the BOSS LOWZ sample). Using mock catalogues of lenses and sources, we disentangle the various contributions to the covariance matrix and compare them with a simple analytical model. We show that not subtracting the lensing measurement around random points from the measurement around the lens sample is equivalent to performing the measurement using the lens density field instead of the lens overdensity field. While the measurement using the lens density field is unbiased (in the absence of systematics), its error is significantly larger due to an additional term in the covariance. Therefore, this subtraction should be performed regardless of its beneficial effects on systematics. Comparing the error estimates from data and mocks for estimators that involve the overdensity, we find that the errors are dominated by the shape noise and lens clustering, which empirically estimated covariances (jackknife and standard deviation across mocks) that are consistent with theoretical estimates, and that both the connected parts of the four-point function and the supersample covariance can be neglected for the current levels of noise. While the trade-off between different terms in the covariance depends on the survey configuration (area, source number density), the diagnostics that we use in this work should be useful for future works to test their empirically determined covariances.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic reduction of sign errors in many-body problems: generalization of self-healing diffusion Monte Carlo to excited states

A recently developed Self-Healing Diffusion Monte Carlo Algorithm [PRB {\bf 79}, 195117 ] is extended to the calculation of excited states. The formalism is based on a excited-state fixed-node approximation and the mixed estimator of the excited-state probability density. The fixed-node ground state wave-functions of inequivalent nodal pockets are found simultaneously using a recursive approach. The decay of the wave-function into lower energy states is prevented using two methods: i) The projection of the improved trial-wave function into previously calculated eigenstates is removed. ii) The reference energy for each nodal pocket is adjusted in order to create a kink in the global fixed-node wave-function which, when locally smoothed out, increases the volume of the higher energy pockets at the expense of the lower energy ones until the energies of every pocket become equal. This reference energy method is designed to find nodal structures that are local minima for arbitrary fluctuations of the nodes within a given nodal topology. We demonstrate in a model system that the algorithm converges to many-body eigenstates in bosonic-like and fermionic cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-39: Comparison of PTV Margins Determined by In-Room Stereoscopic Image Guidance and by On-Board Cone Beam Computed Tomography Technique for Brain Radiotherapy Patients

Purpose: Stereoscopic in room kV image guidance is a faster tool in daily monitoring of patient positioning. Our centre, for the first time in the world, has integrated such a solution from BrainLAB (ExacTrac) with Elekta's volumetric cone beam computed tomography (XVI). Using van Herk's formula, we compared the planning target volume (PTV) margins calculated by both these systems for patients treated with brain radiotherapy. Methods: For a total of 24 patients who received partial or whole brain radiotherapy, verification images were acquired for 524 treatment sessions by XVI and for 334 sessions by ExacTrac out of the total 547 sessions. Systematic and random errors were calculated in cranio-caudal, lateral and antero-posterior directions for both techniques. PTV margins were then determined using van Herk formula. Results: In the cranio-caudal direction, systematic error, random error and the calculated PTV margin were found to be 0.13 cm, 0.12 cm and 0.41 cm with XVI and 0.14 cm, 0.13 cm and 0.44 cm with ExacTrac. The corresponding values in lateral direction were 0.13 cm 0.1 cm and 0.4 cm with XVI and 0.13 cm, 0.12 cm and 0.42 cm with ExacTrac imaging. The same parameters for antero-posterior were for 0.1 cm, 0.11 cm and 0.34 cm with XVI and 0.13 cm, 0.16 cm and 0.43 cm with ExacTrac imaging. The margins estimated with the two imaging modalities were comparable within ± 1 mm limit. Conclusion: Verification of setup errors in the major axes by two independent imaging systems showed the results are comparable and within ± 1 mm. This implies that planar imaging based ExacTrac can yield equal accuracy in setup error determination as the time consuming volumetric imaging which is considered as the gold standard. Accordingly PTV margins estimated by this faster imaging technique can be confidently used in clinical setup.

60 APPLIED LIFE SCIENCES↗

Experiences at the Paul Scherrer Institute With a Remote Patient Positioning Procedure for High-Throughput Proton Radiation Therapy

Purpose: To describe a remote positioning system for accurate and efficient proton radiotherapy treatments. Methods and Materials: To minimize positioning time in the treatment room (and thereby maximize beam utility), we have adopted a method for remote patient positioning, with patients positioned and imaged outside the treatment room. Using a CT scanner, positioning is performed using orthogonal topograms with the measured differences to the reference images being used to define daily corrections to the patient table in the treatment room. Possible patient movements during transport and irradiation were analyzed through periodic acquisition of posttreatment topograms. Systematic and random errors were calculated for this daily positioning protocol and for two off-line protocols. The potential time advantage of remote positioning was assessed by computer simulation. Results: Applying the daily correction protocol, systematic errors calculated over all patients (n = 94) were below 0.6 mm, whereas random errors were below 1.5 mm and 2.5 mm, respectively, for bite-block and for mask immobilization. Differences between pre- and posttreatment images were below 2.8 mm (SD) in abdominal/pelvic region, and below 2.4 mm (SD) in the head. Retrospective data analysis for a subset of patients revealed that off-line protocols would be significantly less accurate. Computer simulations showed that remote positioning can increase patient throughput up to 30%. Conclusions: The use of a daily imaging and correction protocol based on a 'remote' CT could reduce positioning errors to below 2.5 mm and increase beam utility in the treatment room. Patient motion between imaging and treatment were not significant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-24: Setup Uncertainty and Margin of the ExacTrac 6D Image Guide System for Patients with Brain Tumors

Purpose: This study evaluated the setup uncertainties for brain sites when using BrainLAB’s ExacTrac X-ray 6D system for daily pretreatment to determine the optimal planning target volume (PTV) margin. Methods: Between August 2012 and April 2015, 28 patients with brain tumors were treated by daily image-guided radiotherapy using the BrainLAB ExacTrac 6D image guidance system of the Novalis-Tx linear accelerator. DUONTM (Orfit Industries, Wijnegem, Belgium) masks were used to fix the head. The radiotherapy was fractionated into 27–33 treatments. In total, 844 image verifications were performed for 28 patients and used for the analysis. The setup corrections along with the systematic and random errors were analyzed for six degrees of freedom in the translational (lateral, longitudinal, and vertical) and rotational (pitch, roll, and yaw) dimensions. Results: Optimal PTV margins were calculated based on van Herk et al.’s [margin recipe = 2.5∑ + 0.7σ − 3 mm] and Stroom et al.’s [margin recipe = 2∑ + 0.7σ] formulas. The systematic errors (∑) were 0.72, 1.57, and 0.97 mm in the lateral, longitudinal, and vertical translational dimensions, respectively, and 0.72°, 0.87°, and 0.83° in the pitch, roll, and yaw rotational dimensions, respectively. The random errors (σ) were 0.31, 0.46, and 0.54 mm in the lateral, longitudinal, and vertical rotational dimensions, respectively, and 0.28°, 0.24°, and 0.31° in the pitch, roll, and yaw rotational dimensions, respectively. According to van Herk et al.’s and Stroom et al.’s recipes, the recommended lateral PTV margins were 0.97 and 1.66 mm, respectively; the longitudinal margins were 1.26 and 3.47 mm, respectively; and the vertical margins were 0.21 and 2.31 mm, respectively. Conclusion: Therefore, daily setup verifications using the BrainLAB ExacTrac 6D image guide system are very useful for evaluating the setup uncertainties and determining the setup margin.∑σ.

60 APPLIED LIFE SCIENCES↗

Fast patient-specific Monte Carlo brachytherapy dose calculations via the correlated sampling variance reduction technique

Purpose: To demonstrate potential of correlated sampling Monte Carlo (CMC) simulation to improve the calculation efficiency for permanent seed brachytherapy (PSB) implants without loss of accuracy. Methods: CMC was implemented within an in-house MC code family (PTRAN) and used to compute 3D dose distributions for two patient cases: a clinical PSB postimplant prostate CT imaging study and a simulated post lumpectomy breast PSB implant planned on a screening dedicated breast cone-beam CT patient exam. CMC tallies the dose difference, {Delta}D, between highly correlated histories in homogeneous and heterogeneous geometries. The heterogeneous geometry histories were derived from photon collisions sampled in a geometrically identical but purely homogeneous medium geometry, by altering their particle weights to correct for bias. The prostate case consisted of 78 Model-6711 {sup 125}I seeds. The breast case consisted of 87 Model-200 {sup 103}Pd seeds embedded around a simulated lumpectomy cavity. Systematic and random errors in CMC were unfolded using low-uncertainty uncorrelated MC (UMC) as the benchmark. CMC efficiency gains, relative to UMC, were computed for all voxels, and the mean was classified in regions that received minimum doses greater than 20%, 50%, and 90% of D{sub 90}, as well as for various anatomical regions. Results: Systematic errors in CMC relative to UMC were less than 0.6% for 99% of the voxels and 0.04% for 100% of the voxels for the prostate and breast cases, respectively. For a 1 x 1 x 1 mm{sup 3} dose grid, efficiency gains were realized in all structures with 38.1- and 59.8-fold average gains within the prostate and breast clinical target volumes (CTVs), respectively. Greater than 99% of the voxels within the prostate and breast CTVs experienced an efficiency gain. Additionally, it was shown that efficiency losses were confined to low dose regions while the largest gains were located where little difference exists between the homogeneous and heterogeneous doses. On an AMD 1090T processor, computing times of 38 and 21 sec were required to achieve an average statistical uncertainty of 2% within the prostate (1 x 1 x 1 mm{sup 3}) and breast (0.67 x 0.67 x 0.8 mm{sup 3}) CTVs, respectively. Conclusions: CMC supports an additional average 38-60 fold improvement in average efficiency relative to conventional uncorrelated MC techniques, although some voxels experience no gain or even efficiency losses. However, for the two investigated case studies, the maximum variance within clinically significant structures was always reduced (on average by a factor of 6) in the therapeutic dose range generally. CMC takes only seconds to produce an accurate, high-resolution, low-uncertainly dose distribution for the low-energy PSB implants investigated in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Treatment Planning Investigation Into the Dosimetric Effects of Systematic Prostate Patient Rotational Set-Up Errors

The purpose of this study was to investigate the potential dosimetric effects of systematic rotational setup errors on prostate patients planned according to the RTOG P-0126 protocol, and to identify rotational tolerances about either the anterior-posterior (AP) or left-right (LR) axis, under which no correction in setup is required. Eight 3-dimensional conformal radiation therapy (3D-CRT) treatment plans were included in the study, half planned to give 7020 cGy in 39 fractions (P-0126 Arm 1) and the other half planned to give 7920 cGy in 44 fractions (P-0126 Arm 2). Systematic rotations of the pelvic anatomy were simulated in a commercial treatment planning system by rotating opposing apertures in the opposite direction to the simulated anatomy rotation. Rotations were incremented in steps of 2.5 deg. to a maximum of {+-}5.0 deg. and {+-}10.0 deg. the AP and LR axis respectively. Dose distributions were evaluated with respect to the planning objectives set out in the P-0126 protocol. For patients on Arm 2 of the study, maintaining the prescribed dose to 98% of the PTV was found to be problematic for superior-end-posterior rotations beyond 5.0 deg. The results also show that maintaining a rectal dose less than 7500 cGy to 15% of the volume can become problematic for cases of small rectal volume and large superior-end-anterior rotations. We found that setting rotational tolerances will depend on which Arm of the protocol the patient is, and how well the initial plan meets the protocol objectives. In general, we conclude that for rotations about the AP axis, no tolerance level is required; however, cases presenting extreme rotations should be investigated as routine practice. For rotations about the LR axis, we conclude that a tolerance level for patients on Arm 2 of the protocol should be set at {+-}5.0 deg. This tolerance represents the systematic setup error which would require correction if a variation to the initial plan was deemed unacceptable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of High-Order Multipole Errors in the NSLS-II Quadrupoles and Sectupoles on Dynamic and Momentum Aperture

Successful operation of NSLS-II requires sufficient dynamic aperture for injection, as well as momentum aperture for Touschek lifetime. We explore the dependence of momentum and dynamic aperture on higher-order multipole field errors in the quadrupoles and sextupoles. We add random and systematic multipole errors to the quadrupoles and sextupoles and compute the effect on dynamic aperture. We find that the strongest effect is at negative momentum, due to larger closed orbit excursions. Adding all the errors based on the NSLS-II specifications, we find adequate dynamic and momentum aperture.

99 GENERAL AND MISCELLANEOUS↗

SU-E-J-103: Setup Errors Analysis by Cone-Beam CT (CBCT)-Based Imaged-Guided Intensity Modulated Radiotherapy for Esophageal Cancer

Purpose: To quantify setup errors by pretreatment kilovolt cone-beam computed tomography(KV-CBCT) scans for middle or distal esophageal carcinoma patients. Methods: Fifty-two consecutive middle or distal esophageal carcinoma patients who underwent IMRT were included this study. A planning CT scan using a big-bore CT simulator was performed in the treatment position and was used as the reference scan for image registration with CBCT. CBCT scans(On-Board Imaging v1. 5 system, Varian Medical Systems) were acquired daily during the first treatment week. A total of 260 CBCT scans was assessed with a registration clip box defined around the PTV-thorax in the reference scan based on(nine CBCTs per patient) bony anatomy using Offline Review software v10.0(Varian Medical Systems). The anterior-posterior(AP), left-right(LR), superiorinferior( SI) corrections were recorded. The systematic and random errors were calculated. The CTV-to-PTV margins in each CBCT frequency was based on the Van Herk formula (2.5Σ+0.7σ). Results: The SD of systematic error (Σ) was 2.0mm, 2.3mm, 3.8mm in the AP, LR and SI directions, respectively. The average random error (σ) was 1.6mm, 2.4mm, 4.1mm in the AP, LR and SI directions, respectively. The CTV-to-PTV safety margin was 6.1mm, 7.5mm, 12.3mm in the AP, LR and SI directions based on van Herk formula. Conclusion: Our data recommend the use of 6 mm, 8mm, and 12 mm for esophageal carcinoma patient setup in AP, LR, SI directions, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT on Rails With Electronic Portal Imaging for Positioning of Prostate Cancer Patients With Implanted Fiducial Markers

Purpose: The objective of this investigation was to measure the agreement between in-room computed tomography (CT) on rails and electronic portal image (EPI) radiography. Methods and Materials: Agreement between the location of the center of gravity (COG) of fiducial markers (FMs) on CT and EPI images was determined in phantom studies and a patient cohort. A secondary analysis between the center of volume (COV) of the prostate on CT and the COG of FMs on CT and EPI was performed. Agreement was defined as the 95% probability of a difference of {<=}3.0 mm between images. Systematic and random errors from CT and EPI are reported. Results: From 8 patients, 254 CT and EPI pairs were analyzed. FMs were localized to within 3 mm on CT and EPI images 96.9% of the time in the left-right (LR) plane, 85.8% superior-inferior (SI), and 89% anterior-posterior (AP). The differences between the COV on CT and the COG on EPI were not within 3 mm in any plane: 87.8% (LR), 64.2% (SI), and 70.9% (AP). The systematic error varied from 1.2 to 2.9 mm (SI) and 1.8-2.9 mm (AP) between the COG on EPI and COV on CT. Conclusions: Considerable differences between in-room CT and EPI exist. The phantom measurements showed slice thickness affected the accuracy of localization in the SI plane, and couch sag that occurs at the CT on rails gantry could not be totally corrected for in the AP plane. Other confounding factors are the action of rotating the couch and associated time lag between image acquisitions (prostate motion), EPI image quality, and outlining uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Type Ia Supernova Growth-rate Measurement with LSST Simulations: Intrinsic Scatter Systematics

Measurement of the growth rate of structures (fσ 8 ) with Type Ia supernovae (SNe Ia) will improve our understanding of the nature of dark energy and enable tests of general relativity. In this paper, we generate simulations of the 10 yr SN Ia data set of the Rubin-LSST survey, including a correlated velocity field from an N-body simulation and realistic models of SNe Ia properties and their correlations with host-galaxy properties. We find, similar to SN Ia analyses that constrain the dark energy equation-of-state parameters w 0 w a , that constraints on fσ 8 can be biased depending on the intrinsic scatter of SNe Ia. While for the majority of intrinsic scatter models we recover fσ 8 with a precision of ∼13%–14%, for the most realistic dust-based model, we find that the presence of non-Gaussianities in Hubble diagram residuals leads to a bias on fσ 8 of ∼ −20%. When trying to correct for the dust-based intrinsic scatter, we find that the propagation of the uncertainty on the model parameters does not significantly increase the error on fσ 8 . We also find that while the main component of the error budget of fσ 8 is the statistical uncertainty (>75% of the total error budget), the systematic error budget is dominated by the uncertainty on the damping parameter, σ u , that gives an empirical description of the effect of redshift space distortions on the velocity power spectrum. Our results motivate a search for new methods to correct for the non-Gaussian distribution of the Hubble diagram residuals, as well as an improved modeling of the damping parameter.

Carreres, Bastien [Duke Univ., Durham, NC (United ↗

DEEP NEAR-INFRARED SPECTROSCOPY OF PASSIVELY EVOLVING GALAXIES AT z {approx}> 1.4

We present the results of new near-IR spectroscopic observations of passive galaxies at z {approx}> 1.4 in a concentration of BzK-selected galaxies in the COSMOS field. The observations have been conducted with Subaru/MOIRCS, and have resulted in absorption lines and/or continuum detection for 18 out of 34 objects. This allows us to measure spectroscopic redshifts for a sample that is almost complete to K{sub AB} = 21. COSMOS photometric redshifts are found in fair agreement overall with the spectroscopic redshifts, with a standard deviation of {approx}0.05; however, {approx}30% of objects have photometric redshifts systematically underestimated by up to {approx}25%. We show that these systematic offsets in photometric redshifts can be removed by using these objects as a training set. All galaxies fall in four distinct redshift spikes at z = 1.43, 1.53, 1.67, and 1.82, with this latter one including seven galaxies. SED fits to broadband fluxes indicate stellar masses in the range of {approx}4-40 Multiplication-Sign 10{sup 10} M{sub Sun} and that star formation was quenched {approx}1 Gyr before the cosmic epoch at which they are observed. The spectra of several individual galaxies have allowed us to measure their H{delta}{sub F} indices and the strengths of the 4000 A break, which confirms their identification as passive galaxies, as does a composite spectrum resulting from the co-addition of 17 individual spectra. The effective radii of the galaxies have been measured on the COSMOS HST/ACS i{sub F814W}-band image, confirming the coexistence at these redshifts of passive galaxies, which are substantially more compact than their local counterparts with others that follow the local effective radius-stellar mass relation. For the galaxy with the best signal-to-noise spectrum we were able to measure a velocity dispersion of 270 {+-} 105 km s{sup -1} (error bar including systematic errors), indicating that this galaxy lies closely on the virial relation given its stellar mass and effective radius.

79 ASTRONOMY AND ASTROPHYSICS↗

Errors in radial velocity variance from Doppler wind lidar

A high-fidelity lidar turbulence measurement technique relies on accurate estimates of radial velocity variance that are subject to both systematic and random errors determined by the autocorrelation function of radial velocity, the sampling rate, and the sampling duration. Our paper quantifies the effect of the volumetric averaging in lidar radial velocity measurements on the autocorrelation function and the dependence of the systematic and random errors on the sampling duration, using both statistically simulated and observed data. For current-generation scanning lidars and sampling durations of about 30 min and longer, during which the stationarity assumption is valid for atmospheric flows, the systematic error is negligible but the random error exceeds about 10%.

54 ENVIRONMENTAL SCIENCES↗