A Velocity Map Imaging Spectrometer for Electron-Ion And Ion-Ion Coincidence Experiments With Synchrotron Radiation
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Abstract not provided
Not Available
The safeguards community currently lacks a method to rapidly determine the chemical form of radioactive and non-radioactive compounds in real time during inspection activities. Chemical speciation identification can provide important information on both the types of materials that are collected during environmental sampling and can inform inspectors as to where to focus efforts during inspections or complementary access visits. Ion Mobility Spectrometry (IMS) is an established field technique for the detection of explosives, narcotics, and other organic compounds. More recently, electrospray ionization (ESI) has been used to introduce inorganic compounds to IMS instruments for analysis. These techniques have shown the ability to supply chemical information about the compounds being analyzed. Although these laboratory based instruments use a liquid-based injection system, there is evidence in the literature of unaltered and intact pharmaceutical tablets being volatilized and ionized in open atmosphere using heat and a Ni-63 source. Lastly, this work determined that a commercial-off-the-shelf (COTS) IMS could be used for the identification of solid uranium compounds directly after sampling using a COTS sample swipe.
Abstract not provided
Explore the source record for details and available documents.
Not Available
Here, ion mobility spectrometry employing structures for lossless ion manipulations (SLIM-IMS) is an attractive gas-phase separation technique due to its ability to achieve unprecedented effective ion path lengths (>1 km) and IMS resolving powers in a small footprint. The emergence of multilevel SLIM technology, where ions are transferred between vertically stacked SLIM electrode surfaces, has subsequently allowed for ultralong single pass path lengths (>40 m) to be achieved, enabling ultrahigh resolution IMS measurements to be performed over the entire mobility range in a single experiment. The implementation of multiple SLIM levels requires very little additional space for the SLIM system, and we developed a miniature SLIM module (miniSLIM) based on multilevel SLIM technology and report the performance here. The module is 11.1 cm x 6.7 cm x 1.4 cm (L x W x H) and consists of three SLIM levels totaling 1-meter path length. Ion trajectory simulations were used to optimize the SLIM board spacings and SLIM board thicknesses of the miniSLIM IMS system. Methods of efficiently transferring ions between SLIM levels were examined and a new approach using asymmetric traveling waves (TWs) was developed and implemented in the miniSLIM. We experimentally characterized the performance of the --meter multilevel miniSLIM IMS-MS relative to a drift tube IM--MS using an Agilent tuning mixture and tetraalkylammonium cations. The 1-meter miniSLIM achieved a resolving power of up to 131 (CCS/ΔCCS), ~1.5x higher than achievable with a 78 cm path length drift tube IMS, and successfully transmitted the entire ion mobility range in a single separation. We also demonstrated the miniSLIM’s performance as a standalone IMS system (i.e., without MS), showing baseline separation between Agilent tuning mixture cations with the full mobility range observed, and a standard peptide mixture with different charge states readily differentiated. Overall the miniSLIM provides a compact alternative to high performance IMS instruments possessing similar path lengths.
Vacuum ultraviolet photoionization (VUV-PI) mass spectrometry offers an isomer-selective and universal ionization with minimal fragmentation detection of organics in complex chemical systems such as pyrolysis and combustion. Here, in this study, we report a state-of-the-art experimental setup of a universal catalytic microreactor combined with a molecular beam to investigate the thermocatalytic oxidation of a heterogeneous system relevant for probing reactions at gas–solid interfaces. In strong contrast to traditional off-line analytical methods, this technique is capable of identifying and quantifying short-lived species (radicals) as well as stable products to decipher initial reaction steps via the detection of nascent products. The thermocatalytic oxidative degradation of exo-tetrahydrodicyclopentadiene (JP-10), a high energy-density hydrocarbon fuel, over solid titanium–aluminum–boron reactive mixed metal nanopowder (Ti-Al-B RMNP) is exploited to showcase potential applications. Overall, some 59 nascent gas-phase products are identified via photoionization efficiency (PIE) curves, including oxygenated species and hydrocarbons comprising closed-shell molecules and radicals. The critical temperature for complete oxidative decomposition of JP-10 was lowered by 450 K from 1400 K to 950 K, indicating an efficient thermocatalytic action of Ti-Al-B nanoparticles on JP-10. The enabling of a universal chemical microreactor along with VUV-PI mass spectrometry broadens the applicability of this technique to hydrocarbon fuel oxidation and pyrolysis characterization. This isomer-selective sensitive probing along with the detection of radical transients makes the aforementioned technique superior to other conventional analytical techniques such as microflow tube and pyrolysis-gas chromatography coupled with mass spectrometry for investigating similar pyrolysis reactions and comprehensive quantification.
Not provided.
Recent studies suggest that reactions in aqueous microcompartments can occur at significantly different rates than those in the bulk. Most studies have used electrospray to generate a polydisperse source of highly charged microdroplets, leading to multiple confounding factors potentially influencing reaction rates (e.g., evaporation, charge, and size). Thus, the underlying mechanism for the observed enhancement remains unclear. We present a new type of electrodynamic balance - the branched quadrupole trap (BQT) - which can be used to study reactions in microdroplets in a controlled environment. The BQT allows for condensed phase chemical reactions to be initiated by colliding droplets with different reactants and levitating the merged droplet indefinitely. The performance of the BQT is characterized in several ways. Sub-millisecond mixing times as fast as ~400 μs are measured for low velocity (~0.1 m/s) collisions of droplets with <40 μm diameters. The reaction of o-phthalaldehyde (OPA) with alanine in the presence of dithiolthreitol is measured using both fluorescence spectroscopy and single droplet paper spray mass spectrometry. The bimolecular rate constant for reaction of alanine with OPA is found to be 84 ± 10 and 67 ± 6 M -1 s -1 in a 30 μm radius droplet and bulk solution, respectively, which demonstrates that bimolecular reaction rate coefficients can be quantified using merged microdroplets and that merged droplets can be used to study rate enhancements due to compartmentalization. Products of the reaction of OPA with alanine are detected in single droplets using paper spray mass spectrometry. Finally, we demonstrate that single droplets with <100 pg of analyte can easily be studied using single droplet mass spectrometry.
Not provided.