Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Spatiotemporal distribution of NOx storage and impact on NH3 and N2O selectivities during lean/rich cycling of a Ba-based lean NOx trap catalyst

We summarize results from an investigation of the spatiotemporal distribution of NO{sub x} storage and intermediate gas species in determining the performance of a fully formulated, Ba-based, lean NO{sub x} trap catalyst under lean/rich cycling conditions. By experimentally resolving spatiotemporal profiles of gas composition, we found that stored NO{sub x} was significantly redistributed along the monolith axis during the rich phase of the cycle by release and subsequent downstream re-adsorption. Sulfur poisoning of upstream NO{sub x} storage sites caused the active NO{sub x}-storage zone to be displaced downstream. This axial displacement in turn influenced rich-phase NO{sub x} release and re-adsorption. As sulfur poisoning increased, NH3 slip at the catalyst exit also increased due to its formation closer to the catalyst outlet and decreased exposure to downstream oxidation by surface oxygen. N{sub 2}O formation was found to be associated with nitrate reduction rather than oxidation of NH3 by stored oxygen. We propose that the observed evolution of N{sub 2}O selectivity with sulfation can be explained by changes in the spatiotemporal distribution of NO{sub x} storage resulting in either increased or decreased number of precious-metal sites surrounded by nitrates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Passive SCR for lean gasoline NO X control: Engine-based strategies to minimize fuel penalty associated with catalytic NH 3 generation

Lean gasoline engines offer greater fuel economy than common stoichiometric gasoline engines. However, excess oxygen prevents the use of the current three-way catalyst (TWC) to control nitrogen oxide (NO X ) emissions in lean exhaust. A passive SCR concept, introduced by General Motors Global R&D, makes use of a TWC that is already onboard to generate NH 3 under slightly rich conditions, which is stored on the downstream SCR. The stored NH 3 is then used to reduce NO X emissions when the engine switches to lean operation. In this work, the effect of engine parameters, such as air-fuel equivalence ratio and spark timing, on NH 3 generation over a commercial Pd-only TWC with no dedicated oxygen storage component was evaluated on a 2.0-liter BMW lean burn gasoline direct injection engine. NO X reduction, NH 3 formation, and reductant utilization processes were evaluated, and fuel efficiency was assessed and compared to the stoichiometric engine operation case. We found air-fuel equivalence ratio to be one of the most important parameters in controlling the NH 3 production; however, the rich operation necessary for NH 3 production results in a fuel consumption penalty. The fuel penalty can be minimized by adjusting spark timing to increase rich-phase engine out NO X emissions and, thereby, NH 3 levels. Additionally, higher engine out NO X during engine load increase to simulate acceleration resulted in additional fuel savings. Ultimately, a 10% fuel consumption benefit was achieved with the passive SCR approach by optimizing rich air-fuel equivalence ratio and spark timing while also utilizing acceleration load conditions.

54 ENVIRONMENTAL SCIENCES↗

Internal curing of cement pastes by means of superabsorbent polymers visualized by neutron tomography

Highlights: • The kinetics of water release from SAPs were studied by neutron tomography. • The time window for internal curing was linked to the water release from SAPs. • The water release links to the SAP effectiveness to mitigate autogenous shrinkage. • One SAP type was effective while another prematurely released its stored water. Superabsorbent polymers (SAPs) are used to counteract self-desiccation in order to mitigate autogenous shrinkage, a problem in cementitious systems with a low water-to-cement ratio. The release kinetics during internal curing are of importance as not all SAP types are able to efficiently mitigate autogenous shrinkage. In this study, neutron tomography is used to study and visualize the water release kinetics over time. Per-voxel analysis of the time-attenuation curve was performed using piecewise-constant functions. Two different SAP types were studied, one being able to mitigate autogenous shrinkage and one quickly releasing its stored water after final setting. The tomography results correspond to autogenous shrinkage measurements and nuclear magnetic resonance tests. The visualization provides information on the time of water release by the SAPs after setting and the time window of internal curing. This opens additional insights towards the application of SAPs in the construction sector and provides information on the mechanism of internal curing.

36 MATERIALS SCIENCE↗

On the formulation of species reaction rates in the context of multi-species CFD codes using complex chemistry tabulation techniques

In the standard implementation of tabulated combustion models of the FPI or FGM type, the mean species mass fractions are read from look-up tables as functions of a progress variable, mixture fraction and their variances. In multi-species CFD codes however, the mean thermodynamic properties are deduced from the local mean species mass fractions. The unclosed mean source terms appearing in the latter's transport equations must then be given by the chemistry look-up tables. Two possible formulations for this mean source terms are discussed and compared in the present paper. In the reaction rate (RR) formulation, all mean reaction rates are directly read from a look-up table. In the mass fraction (MF) formulation, only the reaction rate for the progress variable is stored, and mean species source terms are constructed to relax the mean mass fractions towards the value stored in the look-up table. After a detailed description of in particular the MF formulation, simple a priori tests of auto-igniting reactors without convection and diffusion are used to illustrate and discuss the differences between the two formulations. Both formulations are then applied to a RANS simulation of the Cabra et al. burner in the context of a PCM-FPI and of an ADF-PCM model. The reported findings confirm the conclusions from the simple tests, highlighting the definitive advantages of the MF formulation. It ensures an accurate reproduction of auto-ignition delays, species evolutions and equilibriums, at the condition that the relaxation parameter is of the order of a characteristic chemical time. Finally, it is shown that the relaxation's effect is only a second order correction. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ITreeForeCast: An integrated modeling software to simulate tree level growth and forest carbon storage

Healthy trees in forest act as a natural carbon sink, capturing carbon. As they grow, they store carbon in their trunks, leaves and roots. Not all trees store carbon at the same rate, or in the same quantities, as it depends on a variety of biophysical and climatic factors. Furthermore, although carbon estimation in trees can be complex, the precision of estimates is tightly linked to trees growth, both in diameter and height. However, the simulation of carbon uptake by forest and forest growth has each been modeled separately, and independently at differing levels of detail and spatial resolution. In this paper, we introduce ITreeForeCast, a simulation model combining the two types of modeling on a unified platform, enabling the investigation of impacts of management strategies on carbon sequestration and wood products. ITreeForeCast is a user-extendable framework that offers new opportunities to model, simulate, and visualize the dynamics of individual trees in a forest, simulate management strategies over time, and carbon uptake.

09 - BIOMASS FUELS↗

Large Scale U.S. Unconventional Fuels Production and the Role of Carbon Dioxide Capture and Storage Technologies in Reducing Their Greenhouse Gas Emissions

This paper examines the role that carbon dioxide capture and storage technologies could play in reducing greenhouse gas emissions if a significant unconventional fuels industry were to develop within the United States. Specifically, the paper examines the potential emergence of a large scale domestic unconventional fuels industry based on oil shale and coal-to-liquids (CTL) technologies. For both of these domestic heavy hydrocarbon resources, this paper models the growth of domestic production to a capacity of 3 MMB/d by 2050. For the oil shale production case, we model large scale deployment of an in-situ retorting process applied to the Eocene Green River formation of Colorado, Utah, and Wyoming where approximately 75% of the high grade oil shale resources within the United States lies. For the CTL case, we examine a more geographically dispersed coal-based unconventional fuel industry. This paper examines the performance of these industries under two hypothetical climate policies and concludes that even with the wide scale availability of cost effective carbon dioxide capture and storage technologies, these unconventional fuels production industries would be responsible for significant increases in CO2 emissions to the atmosphere. The oil shale production facilities required to produce 3MMB/d would result in net emissions to the atmosphere of between 3000-7000 MtCO2 in addition to storing potentially 1000 to 5000 MtCO2 in regional deep geologic formations in the period up to 2050. A similarly sized domestic CTL industry could result in 4000 to 5000 MtCO2 emitted to the atmosphere in addition to potentially 21,000 to 22,000 MtCO2 stored in regional deep geologic formations over the same period up to 2050. Preliminary analysis of regional CO2 storage capacity in locations where such facilities might be sited indicates that there appears to be sufficient storage capacity, primarily in deep saline formations, to accommodate the CO2 from these industries. However, additional analyses plus detailed regional and site characterization is needed, along with a closer examination of competing storage demands.

04 OIL SHALES AND TAR SANDS↗

Modelling the deployment of CO₂ storage in U.S. gas-bearing shales

The proliferation of commercial development in U.S. gas-bearing shales helped to drive a twelve-fold increase in domestic gas production between 2000 and 2010, and the nation's gas production rates continue to grow. While shales have long been regarded as a desirable caprock for CCS operations because of their low permeability and porosity, there is increasing interest in the feasibility of injecting CO₂ into shales to enhance methane recovery and augment CO₂ storage. Laboratory work published in recent years observes that shales with adsorbed methane appear to exhibit a stronger affinity for CO₂ adsorption, offering the potential to drive additional CH₄ recovery beyond primary production and perhaps the potential to store a larger volume of CO₂ than the volume of methane displaced. Recent research by the authors on the revenues associated with CO₂-enhanced gas recovery (CO₂-EGR) in gas-bearing shales estimates that, based on a range of EGR response rates, the average revenue per ton of CO₂ for projects managed over both EGR and subsequent storage-only phases could range from $0.50 to $18/tCO₂. While perhaps not as profitable as EOR, for regions where lower-cost storage options may be limited, shales could represent another “early opportunity” storage option if proven feasible for reliable EGR and CO₂ storage. Significant storage potential exists in gas shales, with theoretical CO₂ storage resources estimated at approximately 30-50 GtCO₂. However, an analysis of the comprehensive cost competitiveness of these various options is necessary to understand the degree to which they might meaningfully impact U.S. CCS deployment or costs. This preliminary analysis shows that the degree to which EGR-based CO₂ storage could play a role in commercial-scale deployment is heavily dependent upon the offsetting revenues associated with incremental recovery; modeling the low revenue case resulted in only five shale-based projects, while under the high revenue case, shales accounted for as much as 20 percent of total U.S. storage in the first 20 years of deployment. Interestingly, even in this highest revenue case, there appear to be no negative-cost projects that would be profitable in a no-policy environment as modeled under the assumptions employed. While this reflects a very first look at the potential for shales, it is clear that more laboratory and experimental work are needed to reduce uncertainty in key variables and begin to differentiate and identify high-potential shales for early pilot study.

54 ENVIRONMENTAL SCIENCES↗

Performance analysis of absorption thermal energy storage for distributed energy systems

In recent years, distributed energy systems (DES) have attracted worldwide attention. Distributed generation unit (DG) in DES usually works under part load during night, which results in low efficiency and the waste heat of DG cannot be fully utilized. This study proposes a novel absorption thermal energy storage system together with electric energy storage for distributed energy systems. The proposed absorption thermal energy storage system which is a combination of absorption chiller and liquid storage tanks, has a higher energy storage density. During off-peak hours, the extra electricity of DG can be used by electric chillers (EC) and the extra waste heat of DG is stored by the proposed absorption thermal energy storage system. The stored thermal energy is released in peak hours to meet the cooling loads of buildings. A case study of DES in a campus under cooling-dominated climate is conducted to evaluate the performance of the proposed system. The results in a typical summer day indicate that the DG utilization rate increases from 80% to 92.9%, meanwhile the required capacities of electric chillers can be obviously reduced. The operating cost of DES also reduces by 12.9% compared with the DES without energy storage. Through appropriate operation strategy, off-the-grid operation for DES can be achieved without energy waste by applying the proposed energy storage method.

Wang, Lingshi↗

Potential benefits of cool walls on residential and commercial buildings across California and the United States: Conserving energy, saving money, and reducing emission of greenhouse gases and air pollutants

Solar-reflective “cool” walls reduce absorption of sunlight by the building envelope, which may decrease cooling load in warm weather and increase heating load in cool weather. Changes to annual heating, ventilation, and air conditioning (HVAC) energy use depend on climate, wall construction, wall orientation, building geometry, HVAC efficiency, and operating schedule. Changes to annual energy cost and energy-related emissions further vary with local energy prices and emission factors. In this work, we used EnergyPlus to perform over 100,000 whole-building energy simulations, spanning 10 different building categories, three building vintages, 16 California climate zones, and 15 United States (U.S.) climate zones. We find that cool walls yielded annual source energy, energy cost, and emission savings in all California climate zones and in warm U.S. (ASHRAE) climate zones. In California, annual whole-building HVAC energy cost savings were 4.0–27% in single-family homes, 0.5–3.8% in medium office buildings, and 0.0–8.5% in stand-alone retail stores. In warm U.S. climates—zones 1A (Miami, FL) through 4B (Albuquerque, NM)—annual HVAC energy cost savings were 1.8–8.3% in single-family homes, 0.3–4.6% in medium office buildings, and 0.5–11% in stand-alone retail stores. California and U.S. fractional source energy and emission savings were comparable to fractional energy cost savings. Per unit surface area modified, cool-wall savings often exceeded cool-roof savings because building codes typically prescribe much less wall insulation than roof insulation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Phase Change Plaster/Paste Composites for Building Envelopes

Thermal energy storage (TES) materials increase a building’s thermal mass and provide the flexibility to shave and time-shift energy use. These materials are needed to enable grid-interactive efficient buildings, allowing building occupants to lower costs by leveraging free ambient heating/cooling as well as shifting consumption to cheaper electricity periods. Phase change materials (PCMs) that store heat through a solid-liquid/solid-solid transformation are of particular interest for TES because of their ability to store large amounts of energy across a constant temperature or very small temperature range. Furthermore, previous studies on PCM building envelopes evaluated products that may only be incorporated as part of new construction and are not easily applicable to existing, energy-intensive buildings. In this work, we leverage laboratory PCM characterization and whole-building energy simulation to study the energy and cost savings of PCM plaster/paste coatings, which can be applied post construction to both new builds and retrofits of existing buildings (about 40% of residential buildings in the United States fall into the retrofit category). We evaluated the energy impact of PCM plaster/paste composites for a single-family residential building in the United States, including layer design (location and thickness), composite properties (phase change temperature, energy density, and shape of the enthalpy curve), and U.S. climate zone. The enthalpy curve shape of PCM shows that phase change temperature and energy density are not the only two parameters that must be considered for PCM selection. Maximizing the energy density amid the effective TES zone is key to boosting energy savings. We also studied PCM price targets with the aim of achieving reasonable payback periods based on both block and time-of-use electricity rates. Moreover, we developed an empirical equation to provide a rough estimate of the energy savings potential of incorporating PCM without the need to perform detailed simulations. These results will help guide the selection and design of PCM plaster/paste composite elements for residential building envelopes.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Investigation of enhanced CO 2 storage in deep saline aquifers by WAG and brine extraction in the Minnelusa sandstone, Wyoming

Geological CO 2 sequestration in deep saline aquifers has been extendedly investigated to reach the goal of carbon neutral as large amount of CO 2 can be reduced in a short time. Here, this study investigates the feasibility of water-alternating-gas (WAG) injection and brine extraction on enhancing CO 2 storage in a target deep saline aquifer, Minnelusa Sandstone in the Powder River Basin (PRB) of Wyoming. An integrated numerical model is developed to account for four scenarios: (1) CO 2 continuous injection (CI) through one injection well, (2) WAG injection through one injection well, (3) CO 2 CI through one injection well and brine extraction through one producer, (4) WAG injection through one injection well and brine extraction through one producer. Simulation results suggest that WAG injection and brine extraction corporately make it possible to enhance CO 2 injectivity while securing CO 2 storage safety. For instance, WAG injection considerably reduces structural trapping contribution while enhances dissolved and residual trapping contributions. As for brine extraction, it can decrease the maximum averaged reservoir pressure by 37% and 22% for CI and WAG injection, respectively. Besides, sensitive analyses of the operational parameters for the fourth scenarios are performed. Results reveal that, when the amount of total CO 2 injection has been predetermined, CO 2 injection time and rate within each period of WAG should be small whereas it is preferable to have large water injection time and rate. This is to secure desirable dissolved and residual trapping contributions (store CO 2 with safety). Sensitive degree results confirm that CO 2 injection rate, water injection time, and CO 2 injection time of WAG injection exhibit significant effects on CO 2 storage whereas the impacts of producer bottom-hole pressure (BHP), water injection rate, and CO 2 -water injection time are relatively weaker. This study not only sheds light on achieving double-win goal: enhance CO 2 injectivity and store CO 2 with safety, but also can be a critical reference for other CO 2 storage in deep saline aquifers.

58 GEOSCIENCES↗

Spatial variations in biomarkers of Mytilus edulis mussels at four polluted regions spanning the Northern Hemisphere

Economic and social developments have taken place at the expense of the health of the environment, both locally and on a global scale. In an attempt to better understand the large-scale effects of pollution and other stressors like climate change on the health status of Mytilus edulis, mussels were collected during the first two weeks of June 2005 at three sites (one pristine and two affected by pollution) located in each of the regions of the Canadian West Coast, the St. Lawrence estuary, the Atlantic East Coast and the northwestern coast of France, covering a total distance of some 11 000 km. The mussels were analyzed for morphologic integrity (condition factor), gametogenic activity (gonado-somatic and gonad maturation index, vitellogenin(Vtg)-like proteins), energy status (temperature-dependent mitochondrial electron transport activity and gonad lipid stores), defense mechanisms (glutathione S-transferase, metallothioneins, cytochrome P4503A activity and xanthine oxidoreductase-XOR), and tissue damage (lipid peroxidation-LPO and DNA strand breaks). The results showed that data from the reference sites in each region were usually not normally distributed, with discriminant factors reaching the number of regions (i.e. four), except for the biomarkers gonadal lipids, XOR and LPO in digestive gland. The integrated responses of the biomarkers revealed that biomarkers of stress were significantly more pronounced in mussels from the Seine estuary, suggesting that the impacts of pollution are more generalized in this area. Mussels from the Seine estuary and the Atlantic East Coast (Halifax Harbor) responded more strongly for Vtg-like proteins, but was not related to gonad maturation and gonado-somatic indexes, suggesting the presence of environmental estrogens. Moreover, these mussels displayed reduced DNA repair activity and increased LPO. Factorial analyses revealed that energy status, cytochrome P4503A activity and Vtg-like proteins were the most important biomarkers. Adaptation to warmer temperatures was reflected at the energy status levels, mussels from both the polluted and warmer sites displaying increased ratios of mitochondrial activity to lipid stores. Regional observations of biomarkers of energy status, gametogenesis and pollutant-related effects were influenced by nutrition, oxygen availability (eutrophication), and thermal history.

60 APPLIED LIFE SCIENCES↗

Cadmium, mercury, and lead in kidney cortex of living kidney donors: Impact of different exposure sources,

Background: Most current knowledge on kidney concentrations of nephrotoxic metals like cadmium (Cd), mercury (Hg), or lead (Pb) comes from autopsy studies. Assessment of metal concentrations in kidney biopsies from living subjects can be combined with information about exposure sources like smoking, diet, and occupation supplied by the biopsied subjects themselves. Objectives: To determine kidney concentrations of Cd, Hg, and Pb in living kidney donors, and assess associations with common exposure sources and background factors. Methods: Metal concentrations were determined in 109 living kidney donors aged 24-70 years (median 51), using inductively coupled plasma-mass spectrometry (Cd and Pb) and cold vapor atomic fluorescence spectrometry (Hg). Smoking habits, occupation, dental amalgam, fish consumption, and iron stores were evaluated. Results: The median kidney concentrations were 12.9 {mu}g/g (wet weight) for cadmium, 0.21 {mu}g/g for mercury, and 0.08 {mu}g/g for lead. Kidney Cd increased by 3.9 {mu}g/g for a 10 year increase in age, and by 3.7 {mu}g/g for an extra 10 pack-years of smoking. Levels in non-smokers were similar to those found in the 1970s. Low iron stores (low serum ferritin) in women increased kidney Cd by 4.5 {mu}g/g. Kidney Hg increased by 6% for every additional amalgam surface, but was not associated with fish consumption. Lead was unaffected by the background factors surveyed. Conclusions: In Sweden, kidney Cd levels have decreased due to less smoking, while the impact of diet seems unchanged. Dental amalgam is the main determinant of kidney Hg. Kidney Pb levels are very low due to decreased exposure.

60 APPLIED LIFE SCIENCES↗

A Scientific Data Processing Framework for Time Series NetCDF Data

ARM Data Integrator (ADI) is a framework to streamline the development of scientific algorithms that analyze time-series NetCDF data, and to improve the content and consistency of the output data products produced by these algorithms. ADI achieves these goals by automating the process of retrieving and preparing data for analysis, supporting the definition of output data products through a graphical interface, and providing a modular, flexible software development architecture. The input data, preprocessing, and output data specifications are defined through a graphical interface and stored in a database. ADI also includes a workflow for data integration, a library of software modules to support the workflow, and a source code generator that produces C, IDL and Python templates. Data preparation support includes automated retrieval of data from input files, merging the retrieved data into appropriately sized chunks, and transformation of the data onto a common coordinate system grid. Through the graphical interface, users can view the details of both their data products and those in the ARM catalog. The variable and attribute definitions of the existing data products can be used to build new output data products. In addition, the rules that make up the ARM archive’s data standards are laid on top of the view of the new data product providing the user with a visual cue indicating where their output violates an archive standard. The necessary configurations are stored in a database that is accessed by the ADI libraries. This paper discusses the ADI framework, its supporting components, and how ADI can significantly decrease the time and cost of implementing scientific algorithms while improving the ability of scientists to disseminate their results.

Atmospheric Science↗

Krypton storage capacity of the Earth's lower mantle

Noble gases are important geochemical tracers allowing reconstructing global volatile cycles in Earth's reservoirs. To constrain these fundamental processes, precise data on their partitioning behavior at deep Earth conditions are needed. Such data are only available at moderate pressures up to 25 GPa due to experimental challenges. We have investigated the possibility of noble gas storage in the Earth's lower mantle up to 115 GPa. We studied the incorporation of krypton in the second most abundant lower mantle mineral (Mg 1-x ,Fe x )O (ferropericlase) as well as in liquid metal-alloys by performing experiments up to 115 GPa and 3700 K using the laser-heated diamond anvil cell coupled to post-mortem EMPA analysis and X-ray absorption spectroscopy. The results reveal that, at these extreme conditions, up to 3 wt.% of krypton can be stored in (Mg 1-x ,Fe x )O and 3000 ppm in the Fe-rich liquid metal. For both phases the storage capacities increase with pressure (between 40 GPa and 60 GPa) at a constant high temperature of 2300 K. Fpc has never been considered as a NG host, despite being the second most abundant mineral in the Earth's LM. Using recent accurate compressibility data, we demonstrate that a substitution of krypton into the anion site of (Mg 1-x ,Fe x )O in form of neutral oxygen Schottky defects at diluted lower mantle conditions is possible. This noble gas incorporation mechanism is in agreement with a previous study on bridgmanite. We show that (Mg 1-x ,Fe x )O exhibits higher noble gas storage capacities than bridgmanite through the lower mantle using lattice strain modeling and including experimental solubility and thermoelastic data for neon, argon, krypton and xenon. We also demonstrate that both phases exhibit the highest solubilities for argon and krypton. We used the solubility data from lattice strain modeling to predict noble gas abundances stored in the solid lower mantle after magma ocean crystallization. The modeled abundances show apparent similarities with estimates for the deep noble gas reservoir that are based on either 3He abundances in ocean island basalts or radiogenic 40Ar abundances in the bulk Earth. This strongly indicates that the crystalline lower mantle may play an important role as deep noble gas storage reservoir. We propose, based on considerations on noble gas replenishment from the lower mantle to the atmosphere, that the lower mantle can only contribute to a small fraction of the present-day atmospheric noble gases. This suggests that the lower mantle is an un-degassed reservoir.

58 GEOSCIENCES↗

A new hydrous iron oxide phase stable at mid-mantle pressures

The amount of hydrogen stored in the Earth's interior is important for a range of issues, including the volatile incorporation during the Earth formation and the co-evolution of the atmosphere, the hydrosphere, and the interior. Recent experiments found titanium bearing ε-FeOOH in a hydrous basaltic system at 12–19 GPa and 1300 K. Pyrite-type FeOOH was found to be stable at pressures higher than 80 GPa. These discoveries suggest possible hydrogen storage in the mantle transition zone and in the mantle below 1800 km depths, respectively. However, it remains uncertain how the potential deep hydrogen storage can be connected to the shallower storage. Here, we report a new hydrous iron oxide (η-Fe 12 O 18+x / 2 H x , x ≈ 2) stable at pressures between the stability fields of the ε- and the pyrite-type FeOOH. Our experiment also shows that the new η phase can exist together with the major lower mantle minerals including bridgmanite and periclase, making it an important hydrogen-bearing phase in the Earth's deep interior. Because of its limited H 2 O storage capacity, which is less than 1/6 of the storage capacity of the pyrite-type phase and the ε phase, the stability of the η phase would result in H 2 O loss during water transport in the mid mantle and therefore limit the amount of H 2 O potentially stored in the Fe–O–H system of the lower mantle. As a result, the large channel in the crystal structure of the η phase could provide potential storage sites for other volatile elements in the deep mantle.

58 GEOSCIENCES↗

Near-isothermal-isobaric compressed gas energy storage

In this paper, the effectiveness of storing energy by compressing and expanding a condensable gas is evaluated. A high efficiency energy storage system, which stores energy by compressing/expanding gas (air) using a liquid (water) piston has been recently introduced and extensively studied. With the use of the liquid piston, the inefficient gas turbomachines used in conventional gas compression/expansion systems are replaced with high efficiency hydraulic machines. Utilizing heat transfer techniques and replacing the non-condensable air with a condensable gas (i.e. CO 2 , synthetic refrigerants, hydrocarbon refrigerants, etc.) have been proposed as methods to improve energy density and roundtrip efficiency of such systems, leading to near isothermal and near isobaric charge/discharge processes. In order to investigate the effectiveness of the proposed concept, a miniature lab-scale experimental setup was designed and built to investigate the compression/expansion characteristics and energy storage efficiency of a system utilizing R134a as the energy storage (primary) working fluid, and mineral refrigerant oil as the liquid piston (secondary) working fluid. Several tests are carried out to quantify energy storage efficiency and energy density. It is found that improving heat transfer rates from/into the storage fluid results in increased efficiency and energy density. A heat-transfer enhancement strategy to achieve near isothermal, isobaric expansion and compression is proposed and investigated experimentally. Some results are generalized and presented in non-dimensional form which can be applied to describe and/or design scaled-up systems. Lastly, a potential working fluid for a scaled-up system is discussed.

25 ENERGY STORAGE↗