Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Extreme-scale EV charging infrastructure planning for last-mile delivery using high-performance parallel computing

Here, this paper addresses stochastic charger location and allocation problems under queue congestion for last-mile delivery using electric vehicles (EVs). The objective is to decide where to open charging stations and how many chargers of each type to install, subject to budgetary and waiting-time constraints. We formulate the problem as a mixed-integer non-linear program, where each station-charger pair is modeled as a multiserver queue with stochastic arrivals and service times to capture the notion of waiting in fleet operations. The model is extremely large, with billions of variables and constraints for a typical metropolitan area; even loading the model in solver memory is difficult, let alone solving it. To address this challenge, we develop a Lagrangian-based dual decomposition framework that decomposes the problem by station and leverages parallelization on high-performance computing systems, where the subproblems are solved by using a cutting plane method and their solutions are collected at the master level. We also develop a three-step rounding heuristic to transform the fractional subproblem solutions into feasible integral solutions. Computational experiments on data from the Chicago metropolitan area with hundreds of thousands of households and thousands of candidate stations show that our approach produces high-quality solutions in cases where existing exact methods cannot even load the model in memory. We also analyze various policy scenarios, demonstrating that combining existing depots with newly built stations under multiagency collaboration substantially reduces costs and congestion. These findings offer a scalable and efficient framework for developing sustainable large-scale EV charging networks.

Capacity allocation↗

Job Creation and Petroleum Independence with E85 in Texas

Protec Fuel Management project objectives are to help design, build, provide, promote and supply biofuels for the greater energy independence, national security and domestic economic growth through job creations, infrastructure projects and supply chain business stimulants. Protec Fuel has teamed up with station owners to convert 5 existing retail fueling stations to include E85 fuel to service existing large number of fleet FFVs and general public FFVs. The stations are located in high flex fuel vehicle locations in the state of TX. Under the project name, “Job Creation and Petroleum Independence with E85 in Texas,” Protec Fuel identified and successfully opened stations strategically located to maximize e85 fueling success for fleets and public. Protec Fuel and industry affiliates and FFV manufacturers are excited about these stations and the opportunities as they will help reduce emissions, increase jobs, economic stimulus benefits, energy independence and petroleum displacement.

02 PETROLEUM↗

CSULA Hydrogen Refueling Facility Performance Evaluation and Optimization

Throughout its history, Cal State LA has been in the forefront of advanced energy and transportation technologies. The station is located at the intersection of two major highways in Los Angeles region and has a convenient access. It is capable of producing up to 60 kg/day and can fuel 15-20 vehicles per day. Cal State LA had partnered with DOE to establish a robust station operation and performance data collection program. This consisted of equipping the station with additional instrumentation and collecting fueling performance data for several years. The data was further furnished to NREL for processing and agglomeration with data from other stations. In addition to fueling, maintenance and failure events were shared as well as hydrogen purity reports. The station has also undergone several upgrades in fueling protocols and hardware for improved performance and code compliance.

08 HYDROGEN↗

Monitoring Potential Transport of Radioactive Contaminants in Shallow Ephemeral Channels: FY2018

Desert Research Institute (DRI) is conducting a field assessment of the potential for contaminated soil to be transported from the Smoky Site Contamination Area (CA) as a result of storm runoff. This activity supports U.S. Department of Energy (DOE) Environmental Management Nevada Program (EM NV) efforts to establish post-closure monitoring plans for the Smoky Site Soils Corrective Action Unit (CAU) 550. The work is intended to confirm the likely mechanism of transport and determine the meteorological conditions that might cause the movement of contaminated soils, as well as determine the particle size fraction that is most closely associated with transported radionuclide-contaminated soils. These data will facilitate the design of the appropriate post-closure monitoring program. In 2011, DRI installed a meteorological monitoring station on the west side of the Smoky Site CA and a hydrologic (runoff) monitoring station within the CA, near the east side. The meteorological station collects air temperature, wind speed, wind direction, relative humidity, precipitation, solar radiation, barometric pressure, soil temperature, and soil water content data. The maximum, minimum, and average or total values (as appropriate) for each of these parameters are recorded for each 10-minute interval. The maximum, minimum, and average water depth in the flume installed at the hydrologic station are also recorded for each 10-minute interval. This report presents the data collected from these stations during fiscal year (FY) 2018. During the FY2018 reporting period, the warmest months were June, July, and August and the coldest were December through March. Solar radiation showed the same seasonal trend. Monthly mean wind speeds were highest in the spring (March through May) and early summer (June). Winds were generally from the west during the summer and from the north throughout the fall and winter. The monthly average relative humidity ranged from the mid-teens to approximately 50 percent. Humidity was lowest in the fall and highest in the winter. Monthly total precipitation ranged from 0 in October, December, and June to approximately 1.38 inches (in) (35.05 millimeters [mm]) in July. Total precipitation for FY2018 was 3.86 in (98.04 mm). During the reporting period, two runoff events were recorded at the flume. One occurred on July 14, 2018, in response to precipitation earlier the same day. This event produced a peak water depth of 11.26 in (28.60 centimeters [cm]) in the flume, which is equivalent to a discharge of 1.86 cubic feet per second (cfs) (0.05 cubic meters per second [cm/s]) and a velocity of 3.97 feet per second (fps) (1.21 meters per second [m/s]) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 1.29 fps (0.39 m/s), which is sufficient to transport silts and fine sands. The second flow event occurred in response to earlier precipitation on September 4, 2018. This event produced a peak water depth of 0.78 in (1.98 cm) in the flume, which is equivalent to a discharge of 0.03 cfs (0.001 cm/s) and a velocity of 1.17 fps (0.36 m/s) through the flume. Applying the flume hydraulic measurements to the channel geometry at the nearest surveyed cross-section it was determined that the velocity through the channel was 0.03 fps (0.01 m/s). Although neither runoff event produced sufficient flow velocities through the natural channel to cause local erosion and transport of coarser bedload materials, the velocity of the first runoff event was sufficient to transport silts and fine sands, which have been shown to be preferentially associated with radionuclide contaminants. Therefore, a sampling event was planned after the first flow event in conjunction with a periodic maintenance inspection. As no suspended load sampling is available at this location, bedload samples were collected from the vicinity of the flume on August 7, 2018. The collected sediment was separated into three particle size fractions and each fraction was analyzed for americium-241 (Am-241), plutonium-238 (Pu-238), and plutonium-239/240 (Pu-239/240) by alpha spectrometry. The two smaller particle size fractions had higher concentrations of all three radionuclides than the largest particle size fraction. Additionally, Pu-239/240 had the highest concentration and Pu-238 had the lowest concentration in all samples. The same relationship between the concentrations of Pu-238 and Pu-239/240 was seen in samples reported in FY2013 and FY2014. Observation of meteorological and environmental conditions that lead to storm runoff will help identify parameters and threshold conditions that should be incorporated into postclosure monitoring plans for this and similar sites as well as aid in determining appropriate closure strategies for other Soils CAUs.

54 ENVIRONMENTAL SCIENCES↗

CalderaCast User Manual Version 1.0

CalderaCast is a user-friendly web-based tool for electrical-load forecast, providing stakeholders with a fully customizable decision-support framework that estimates the likely power draw from a possible future electric-vehicle (EV) charging station at a given location on a given day along an alternative fuel corridor (AFC). These EV charging profiles are accurately modeled in CalderaCast using the Caldera software framework developed by Idaho National Laboratories (INL), reflecting the realistic charging levels observed in actual charge events. This tool was developed as part of the National Electric Vehicle Infrastructure (NEVI) program, which is quickly generating substantial interest from would-be charging station operators (CSO), large and small electric utilities, and state transportation planners, some of whom had not seriously considered EV charging previously. All these entities—with or without background in EV infrastructure—must estimate the electricity load that a proposed charging station will generate. This load forecast is critically important for a utility to properly assess the capacity of their distribution network to support the proposed station or properly size grid upgrades for potential load growth due to future EV adoption, vehicle technology improvements, or station growth. This document describes each aspect of the CalderaCast tool and provides guidance to users who are interested in utilizing the tool for their work.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating national hydrogen refueling infrastructure requirement and economic competitiveness of fuel cell electric long-haul trucks

This study explored the national hydrogen refueling infrastructure requirement along major United States (US) interstate highway corridors to support the deployment of fuel cell electric trucks (FCETs) for the national long-haul trucking fleet. Given the long-haul trucking shipment demand in 2025 projected by the Freight Analysis Framework, locations and capacities of hydrogen stations were identified for inter-zone freight flows, and the total daily refueling demand was estimated for intra-zone flows for each FAF zone. Based on the infrastructure deployment results, we conducted an economic feasibility analysis of FCETs by evaluating the total ownership cost. We found that when the FCET penetration is relatively high (e.g., 10% penetration), FCETs become more competitive in terms of fuel cost and idling cost and could be economic viable if the incremental vehicle cost is reduced to meet the near-term FCET technology cost targets and the liquefaction cost is reduced to an optimal case. We also observed that the station cost depends on regional factors, particularly regional demand, which is used to determine station capacity. Thus, one possible strategy for station roll-out is to have early investment in target regions where station costs are expected to be relatively low such as the Pacific and West South Central regions.

33 ADVANCED PROPULSION SYSTEMS↗

Leveraging Extremal Dependence to Better Characterize the 2021 Pacific Northwest Heatwave

Abstract In late June, 2021, a devastating heatwave affected the US Pacific Northwest and western Canada, breaking numerous all-time temperature records by large margins and directly causing hundreds of fatalities. The observed 2021 daily maximum temperature across much of the U.S. Pacific Northwest exceeded upper bound estimates obtained from single-station temperature records even after accounting for anthropogenic climate change, meaning that the event could not have been predicted under standard univariate extreme value analysis assumptions. In this work, we utilize a flexible spatial extremes model that considers all stations across the Pacific Northwest domain and accounts for the fact that many stations simultaneously experience extreme temperatures. Our analysis incorporates the effects of anthropogenic forcing and natural climate variability in order to better characterize time-varying changes in the distribution of daily temperature extremes. We show that greenhouse gas forcing, drought conditions and large-scale atmospheric modes of variability all have significant impact on summertime maximum temperatures in this region. Our model represents a significant improvement over corresponding single-station analysis, and our posterior medians of the upper bounds are able to anticipate more than 96% of the observed 2021 high station temperatures after properly accounting for extremal dependence. Supplementary materials accompanying this paper appear online.

Zhang, Likun (ORCID:0000000154584556)↗

Economics of electric vehicle corridor fast charging in the United States

Corridor direct-current fast charging (DCFC) stations enable long-distance electric vehicle travel, yet their economics remain uncertain due to high capital costs, low initial utilization, and exposure to utility demand charges. This study evaluates the long-term economics of corridor DCFC across the United States, incorporating capital and operating expenses-including charging equipment and real-world utility tariffs-alongside modeled station utilization, financial incentives, and ancillary retail revenue. In the Baseline scenario, modeled breakeven costs for corridor DCFC average $\$$0.42/kWh over 20 years, yet fewer than half of stations reach cost parity with gasoline on a per-mile basis. Utilization is the primary driver of cost variation, with low-utilization stations costing roughly six times more per kilowatt-hour than the national average. Excluding stations that fail to reach cost parity reduces National Highway System coverage within 50 miles from 94% to 67%, underscoring the trade-off between market-driven deployment and comprehensive network coverage. These results provide guidance for charging providers, utilities, planners, and policymakers seeking to develop and sustain a financially viable national corridor charging network.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Daily grass reference evapotranspiration with Meteosat Second Generation shortwave radiation and reference ET products

Here we assess the accuracy of estimating daily grass reference evapotranspiration (PM-ET o ) using daily shortwave radiation (R s ) and reference evapotranspiration (ET REF ) products provided by the Meteosat Second Generation (MSG) geostationary satellite delivered by the Satellite Applications Facility on Land Surface Analysis (LSA-SAF) framework. The accuracy of using reanalysis ERA5 shortwave radiation data (R s ERA5 ) provided by the European Center for Medium-Range Weather Forecasts (ECMWF) is also evaluated. The assessments were performed using observed weather variables at 37 weather stations distributed across continental Portugal, where climate conditions range from semi-arid to humid, and 12 weather stations located in Azores islands, characterized by humid, windy and often cloudy conditions. This study&#x27;s use of data from a variety of climate conditions contributed to a unique and innovative assessment of the usability of LSA-SAF and ERA5 products for ET o estimation. The first assessment focused on comparing LSA-SAF estimates of R s (R s LSA-SAF ) against ground stations (R s ground ). The results showed a good matching between the two R s data sets for continental Portugal but a tendency for R s LSA-SAF to under-estimate R s ground in the cloudy islands of Azores. ET o values computed using R s LSA-SAF data and observed temperature, humidity and wind speed (ET o LSA-SAF ) were then compared with PM-ET o estimates with ground-based data, which were used as benchmark; input data of temperature and humidity needed for PM-ET o were quality checked for surface aridity effects. It was observed that ET o LSA-SAF is strongly correlated with PM-ET o (R 2 > 0.97) for most locations in continental Portugal, with regression coefficient of a linear regression forced to the origin ranging between 0.95 and 1.05, mean root mean square error (RMSE) of 0.13 mm d –1 , and Nash and Sutcliff efficiency of modeling (EF) above 0.95. For most Azores locations, ET o LSA-SAF over-estimated PM-ET o . This is likely a consequence of the high spatio-temporal heterogeneity of weather conditions that occur in these oceanic islands together with the different footprints of satellite (averaged over the pixel) and station observations. Reanalysis ERA5 shortwave radiation data presented similar behavior to the LSA-SAF products, however with slightly lower accuracy. The daily LSA-SAF ET REF product (ET REF LSA-SAF ) was assessed and results have shown a good accuracy of this product, with acceptable RMSE and high EF values, for continental Portugal but a low accuracy for the Azores islands. A simplified bias correction approach was shown to improve both ET o derived from the LSA-SAF products, namely for Azores stations, which seem to be representative of smaller areas. The use of the FAO-PM temperature approach (PMT) was also assessed using the R s LSA-SAF and R s ERA5 data, which showed a superiority of the LSA-SAF product for ET o estimations (ET o PMT LSA-SAF ). No significant differences (p < 0.05) were observed in terms of the median value of the RMSE when adopting ET o PMT and ET REF LSA-SAF . Differently, results showed that using the R s LSA-SAF in the PMT approach (ET o PMT LSA-SAF ) produces significantly better RMSE results than ET o PMT and ET REF LSA-SAF . Overall, the performed assessment allows concluding that the use of R s LSA-SAF, and to a lesser extent the use of the R s ERA5 , highly improves the accuracy of computation of ET o when R s observations are not available, including when only temperature data are accessible. The use of the ET REF LSA-SAF product is a good alternative when observed weather data are not available.

54 ENVIRONMENTAL SCIENCES↗

Rainfall erosivity in Slovenia: Sensitivity estimation and trend detection

Highlights: • Rainfall erosivity for 10 rainfall stations located in Slovenia was evaluated. • Rainfall erosivity trends are mostly positive while mostly statistically insignificant. • The maximum rainfall erosivity is obtained under Alpine climate. • Monthly rainfall erosivity was computed. • Sensitivity analyses were carried out. Slovenia is one of the EU countries with the largest values and largest amounts of variability in rainfall erosivity, with maximum annual values exceeding 10,000 MJ mm ha{sup -1} h{sup -1} yr{sup -1}. Five-minute rainfall data was analysed from 10 Slovenian rainfall stations with data-length availability longer than 25 years with a maximum data length of 69 years and a total data-station length equal to 443 years. Trends in the rainfall erosivity R-factor were detected for four different sub-samples using monthly, half-year, and annual rainfall erosivity values. The results indicate that rainfall erosivity trends for the selected Slovenian stations are mostly statistically insignificant, with the selected significance level of 0.05. However, a larger share of identified trends are positive than negative. The maximum annual rainfall erosivity values were obtained for one specific mountain station. Furthermore, a sensitivity analysis regarding the rainfall erosivity factor R calculation showed that the rainfall threshold parameter (12.7 mm) that is used to remove the small-magnitude rainfall events in order to reduce the computational burden can attribute up to 10% of the average annual R-values in cases where this threshold is not used. Other parameters have, on average, a smaller impact on the calculated rainfall erosivity. Furthermore, the application of local kinetic energy equations resulted in, on average, about 20% higher annual rainfall erosivity values compared to the equation that is proposed by the Revised Universal Soil Loss Equation (RUSLE) manual and was not developed specifically for this region.

54 ENVIRONMENTAL SCIENCES↗

Optimal design of microseismic monitoring network: Synthetic study for the Kimberlina CO2 storage demonstration site

Microseismic monitoring can play a crucial role to ensure safe long-term geological carbon storage. For reliable long-term monitoring for CO2-injection-induced microseismic events, a surface seismic array is desirable in addition to borehole geophone sensors. Optimal design of surface seismic network is of great interest to achieve cost-effective monitoring. We develop a methodology to determine the optimal number of surface seismic stations with a geometrically satisfactory distribution for given monitoring regions. We design an optimal microseismic monitoring network based on widely-accepted guiding principles, and the relationship between the location accuracy of microseismic events and the total number of seismic stations. We determine the optimal number of seismic stations based on the trade-off curve of the event location accuracy vs. the total number of seismic stations. We apply our optimal design method to the Kimberlina carbon storage site in California. We use a synthetic Kimberlina model to show that approximately 20 surface seismic stations with a geometrically satisfactory distribution are preferred for the best trade-off between the cost and the event location accuracy.

58 GEOSCIENCES↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Intra and Interfraction Mediastinal Nodal Region Motion: Implications for Internal Target Volume Expansions

The purpose of this study was to determine the intra and interfraction motion of mediastinal lymph node regions. Ten patients with nonsmall-cell lung cancer underwent controlled inhale and exhale computed tomography (CT) scans during two sessions (40 total datasets) and mediastinal nodal stations 1-8 were outlined. Corresponding CT scans from different sessions were registered to remove setup error and, in this reference frame, the centroid of each nodal station was compared for right-left (RL), anterior-posterior (AP), and superior-inferior (SI) displacement. In addition, an anisotropic volume expansion encompassing the change of the nodal region margins in all directions was used. Intrafraction displacement was determined by comparing same session inhale-exhale scans. Interfraction reproducibility of nodal regions was determined by comparing the same respiratory phase scans between two sessions. Intrafraction displacement of centroid varied between nodal stations. All nodal regions moved posteriorly and superiorly with exhalation, and inferior nodal stations showed the most motion. Based on anisotropic expansion, nodal regions expanded mostly in the RL direction from inhale to exhale. The interpatient variations in intrafraction displacement were large compared with the displacements themselves. Moreover, there was substantial interfractional displacement ({approx}5 mm). Mediastinal lymph node regions clearly move during breathing. In addition, deformation of nodal regions between inhale and exhale occurs. The degree of motion and deformation varies by station and by individual. This study indicates the potential advantage of characterizing individualized nodal region motion to safely maximize conformality of mediastinal nodal targets.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integral LOCA fragmentation test on high-burnup fuel

Increasing the fuel burnup limit in light water reactors is sought to enhance fuel cycle economics and requires establishing a technical basis. Experimental observations of severe fuel fragmentation under loss-of-coolant-accident conditions at Halden and Studsvik had raised the need for additional considerations during the development of this technical basis. These test data suggested that the burnup threshold for high burnup fuel fragmentation may be influenced by pre-transient power. Additional loss-of-coolant-accident test data is therefore valuable to complement these tests and enhance the current state of understating. Oak Ridge National Lab has developed the Severe Accident Test Station capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident and beyond design basis accident scenarios. Severe Accident Test Station provides various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident testing, defueled oxidation quench testing, and high-temperature beyond design basis accident testing. Severe Accident Test Station has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory at Oak Ridge National Lab. Furthermore, descriptions of the in-cell re-fabrication capabilities and assembly of the loss-of-coolant-accident test train are provided. Installation of the Severe Accident Test Station system and in-cell re-fabrication restores United States capability to examine postulated and extended loss-of-coolant-accident conditions on spent fuel and cladding and provides a platform for evaluating advanced fuel and accident-tolerant fuel cladding concepts. Lastly, three in-cell integral loss-of-coolant-accident test were performed in the Severe Accident Test Station and compared to the Nuclear Regulatory Commission sponsored loss-of-coolant-accident test as well as the original loss-of-coolant-accident test performed at Argonne National Lab. Finally, the results of these tests as well as all publicly available integral loss-of-coolant-accident test were used to validate a threshold for high burnup fuel fragmentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterizing the relationship between satellite phenology and pollen season: A case study of birch

Pollen released by vegetation in urban and surrounding rural areas is an important risk factor for respiratory allergies. Mapping the onset, duration, and severity of pollen is difficult, because of insufficient stations and/or monitoring networks at the national and international levels. To address this challenge, we evaluated the spatiotemporal relationship between satellite derived vegetation phenology and in-situ station derived information of pollen season during 2001–2015 at five stations in Canada. First, we calculated annual indicators of start of season (SOS) and start of pollen season (SPS) for birch from Landsat time series and pollen concentration data, respectively, at the five stations. Second, we explored the relationship between derived indicators of SOS and SPS and investigated the scale effect on the relationship. Our results indicate the Landsat based SOS is a good proxy for the indicator of SPS in the birch dominated area. The mean SOS and SPS in the study period are close (within 2.7?days) across the five stations. The interannual variability of SOS and SPS suggests the satellite derived phenology indicator can capture well the dynamics of pollen season in spring. Our analysis also indicates that the annual SOS at a finer resolution (30?m) is more consistent with SPS as compared to the indicators derived from coarser resolution satellite observations. This study shows the potential of using fine spatial resolution satellite data (e.g., Landsat) to derive the pollen season indicators, which is important for predicting pollen season severity and risk, and assessment of their impacts on respiratory allergies in urban domains.

Landsat, Phenology, Spring leaf unfolding, Pollen,↗

Quality control and estimation of global solar radiation in China

Measurements of surface radiation in China are too sparse to meet demand for scientific research and engineering applications. Moreover, the radiation data often include erroneous and questionable values though preliminary quality-check has been done before the data release. Therefore, quality control of radiation data is often a prerequisite for using these data. In this study, a set of quality-check procedures were implemented to control the quality of the solar radiation measurements at 97 stations in China. A hybrid model for estimating global solar radiation was then evaluated against the controlled data. The results show that the model can estimate the global radiation with accuracy of MBE less than 1.5 MJ m{sup -2} and RMSE less than 2.8 MJ m{sup -2} for daily radiation and RMSE less than 2.0 MJ m{sup -2} for monthly-mean daily radiation at individual stations over most of China except at a few stations where unsatisfactory estimates were possibly caused by severe air pollution or too dense clouds. The MBE averaged over all stations are about 0.7 MJ m{sup -2} and RMSE about 2.0 MJ m{sup -2} for daily radiation and RMSE about 1.3 MJ m{sup -2} for monthly-mean daily radiation. Finally, this model was used to fill data gaps and to expand solar radiation data set using routine meteorological station data in China. This data set would substantially contribute to some radiation-related scientific studies and engineering applications in China. (author)

14 SOLAR ENERGY↗

Long-term strategic planning of inter-city fast charging infrastructure for battery electric vehicles

Here, this study introduces a multistage mixed integer modeling framework for long-term strategic planning of the battery electric vehicle (BEV) inter-city fast charging infrastructure. In response to the growing BEV inter-city travel demand, the framework integrates both an optimization model for decisions on where and when to build charging stations and a stochastic queuing model to determine how many chargers are needed for each station. A genetic algorithm based heuristic method is developed to efficiently solve the problem. The model is applied to investigate the long-term infrastructure requirement in the state of California where significant growth in BEV demand is expected in coming decades. Our findings indicate that the charging infrastructure is expanded in both network coverage (number of stations) and service capacity (number of chargers per station) as the BEV demand grows. We also found that the infrastructure requirement is dependent on many factors, such as the BEV electrified range, the required level of service at charging stations, and the range anxiety cost. For most simulated scenarios, the results show that it is beneficial to invest in the inter-city fast charging infrastructure, even though the range anxiety cost is at its low end.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An "In Situ" Calibration Correction Procedure (KCICLO) Based on AOD Diurnal Cycle: Application to AERONET-El Arenosillo (Spain) AOD Data Series

Aerosol optical depth (AOD) very often shows a distinct diurnal cycle pattern, which seems to be an artifact resulting from an incorrect calibration (or an equivalent effect, such as filter degradation). The shape of this fictitious AOD diurnal cycle varies as the inverse of the solar air mass (m) and the magnitude of the effect is greatest at midday. The observation of this effect is not easy at many field stations, and only those stations with good weather conditions permit an easier detection and the possibility of its correction. By taking advantage of this dependence on the air mass, we propose an improved “in situ” correction-calibration procedure to AOD measured data series. The method is named KCICLO because the determination of a constant K and the behavior of AOD as a cycle (ciclo, in Spanish). We estimate it has an accuracy of 0.2–0.5% for the calibration ratio constant K, or 0.002–0.005 in AOD at field stations. Although the KCICLO is an “in situ” calibration method, we recommend it to be used as an AOD correction method for field stations. At high-altitude sites, it may be used independently of the classical Langley method (CLM). However, we also recommend it to be used as a complement to CLM, improving it considerably. The application of this calibration correction method to the nearly 5 year AOD data series at El Arenosillo (Huelva, southwestern Spain) station belonging to Aerosol Robotic Network (AERONET)-PHOTONS shows that 8 (50%) of 16 filters of the four analyzed Sun photometers were outside of the 0.02 uncertainty of AERONET specification. The largest departures reached values of 0.06. The results show the efficiency of the method and a significant improvement over other “in situ” methods, with no other information required beyond the same AOD data.

47 OTHER INSTRUMENTATION↗