Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Hunting the most distant stars in the Milky Way: methods and initial results

We present a new catalog of 404 M giant candidates found in the UKIRT Infrared Deep Sky Survey (UKIDSS). The 2400 deg{sup 2} available in the UKIDSS Large Area Survey Data Release 8 resolve M giants through a volume four times larger than that of the entire Two Micron All Sky Survey. Combining near-infrared photometry with optical photometry and proper motions from the Sloan Digital Sky Survey yields an M giant candidate catalog with less M dwarf and quasar contamination than previous searches for similarly distant M giants. Extensive follow-up spectroscopy of this sample will yield the first map of our Galaxy's outermost reaches over a large area of sky. Our initial spectroscopic follow-up of ∼30 bright candidates yielded the positive identification of five M giants at distances ∼20-90 kpc. Each of these confirmed M giants have positions and velocities consistent with the Sagittarius stream. The fainter M giant candidates in our sample have estimated photometric distances ∼200 kpc (assuming [Fe/H] = 0.0), but require further spectroscopic verification. The photometric distance estimates extend beyond the Milky Way's virial radius, and increase by ∼50% for each 0.5 dex decrease in assumed [Fe/H]. Given the number of M giant candidates, initial selection efficiency, and volume surveyed, we loosely estimate that at least one additional Sagittarius-like accretion event could have contributed to the hierarchical build-up of the Milky Way's outer halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Parallax beyond a kiloparsec from spatially scanning the wide field Camera 3 on the Hubble space telescope

We use a newly developed observing mode on the Hubble Space Telescope (HST) and Wide Field Camera 3, spatial scanning, to increase source sampling a thousand-fold and measure changes in source positions to a precision of 20-40 μas, more than an order of magnitude better than attainable in pointed observations. This observing mode can usefully measure the parallaxes of bright stars at distances of up to 5 kpc, a factor of 10 farther than achieved thus far with HST. The technique should also provide a unique crosscheck of future parallax measurements from Gaia. Long-period classical Cepheid variable stars in the Milky Way, nearly all of which reside beyond 1 kpc, are especially compelling targets for parallax measurements from scanning, as they may be used to anchor a determination of the Hubble constant to ∼1%. We illustrate the method by measuring to high precision the parallax of a classical Cepheid, SY Aurigae, at a distance of more than 2 kpc, using five epochs of spatial-scan data obtained at intervals of six months. Rapid spatial scans also enable photometric measurements of bright Milky Way Cepheids—which would otherwise saturate even in the shortest possible pointed observations—on the same flux scale as extragalactic Cepheids, which is a necessity for reducing a leading source of systematic error in the Hubble constant. We demonstrate this capability with photometric measurements of SY Aur on the same system used for Cepheids in Type Ia supernova host galaxies. While the technique and results presented here are preliminary, an ongoing program with HST is collecting such parallax measurements for another 18 Cepheids to produce a better anchor for the distance scale.

79 ASTRONOMY AND ASTROPHYSICS↗

NARROW Na AND K ABSORPTION LINES TOWARD T TAURI STARS: TRACING THE ATOMIC ENVELOPE OF MOLECULAR CLOUDS

We present a detailed analysis of narrow Na i and K i absorption resonance lines toward nearly 40 T Tauri stars in Taurus with the goal of clarifying their origin. The Na i λ5889.95 line is detected toward all but one source, while the weaker K i λ7698.96 line is detected in about two-thirds of the sample. The similarity in their peak centroids and the significant positive correlation between their equivalent widths demonstrate that these transitions trace the same atomic gas. The absorption lines are present toward both disk and diskless young stellar objects, which excludes cold gas within the circumstellar disk as the absorbing material. A comparison of Na i and CO detections and peak centroids demonstrates that the atomic gas and molecular gas are not co-located, the atomic gas being more extended than the molecular gas. The width of the atomic lines corroborates this finding and points to atomic gas about an order of magnitude warmer than the molecular gas. The distribution of Na i radial velocities shows a clear spatial gradient along the length of the Taurus molecular cloud filaments. This suggests that absorption is associated with the Taurus molecular cloud. Assuming that the gradient is due to cloud rotation, the rotation of the atomic gas is consistent with differential galactic rotation, whereas the rotation of the molecular gas, although with the same rotation axis, is retrograde. Our analysis shows that narrow Na i and K i absorption resonance lines are useful tracers of the atomic envelope of molecular clouds. In line with recent findings from giant molecular clouds, our results demonstrate that the velocity fields of the atomic and molecular gas are misaligned. The angular momentum of a molecular cloud is not simply inherited from the rotating Galactic disk from which it formed but may be redistributed by cloud–cloud interactions.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic structure of an FeCrMoCBY metallic glass revealed by high energy x-ray diffraction

Amorphous bulk metallic glasses with the composition Fe 48 Cr 15 Mo 14 C 15 B 6 Y 2 have been of interest due to their special mechanical and electronic properties, including corrosion resistance, high yield-strength, large elasticity, catalytic performance, and soft ferromagnetism. Here, we apply a reverse Monte Carlo technique to unravel the atomic structure of these glasses. The pair-distribution functions for various atomic pairs are computed based on the high-energy x-ray diffraction data we have taken from an amorphous sample. Monte Carlo cycles are used to move the atomic positions until the model reproduces the experimental pair-distribution function. The resulting fitted model is consistent with our ab initio simulations of the metallic glass. Our study contributes to the understanding of functional properties of Fe-based bulk metallic glasses driven by disorder effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active Surveillance for Norovirus in a US Veterans Affairs Patient Population, Houston, Texas, 2015 -- 2016

Norovirus is a leading cause of acute gastroenteritis (AGE); however, few data exist on endemic norovirus disease burden among adults. Candidate norovirus vaccines are currently in development for all ages, and robust estimates of norovirus incidence among adults are needed to provide baseline data. Here, ee conducted active surveillance for AGE among inpatients at a Veterans Affairs (VA) hospital in Houston, Texas. Patients with AGE (≥3 loose stools, ≥2 vomiting episodes, or ≥1 episode of both loose stool and vomiting, within 24 hours) within 10 days of enrollment and non-AGE control patients were enrolled. Demographic data and clinical characteristics were collected. Stool samples were tested using the FilmArray gastrointestinal panel; virus-positives were confirmed by real-time reverse transcription polymerase chain reaction and genotyped by sequencing. From November 2, 2015 through November 30, 2016, 147 case patients and 19 control patients were enrolled and provided a stool specimen. Among case patients, 139 (95%) were male and 70 (48%) were aged ≥65 years. Norovirus was the leading viral pathogen detected (in 16 of 20 virus-positive case patients) and accounted for 11% of all AGE cases. No viral pathogens were detected among control patients. Incidence of norovirus-associated hospitalization was 20.3 cases/100 000 person-years and was similar among those aged <65 and ≥65 years. This active surveillance platform employed screening and enrollment of hospitalized VA patients meeting a standardized AGE case definition, as well as non-AGE control patients. Data from this study highlight the burden of norovirus in a VA inpatient population and will be useful in policy considerations of a norovirus vaccine.

60 APPLIED LIFE SCIENCES↗

Interface properties and built-in potential profile of a LaCr O 3 / SrTi O 3 superlattice determined by standing-wave excited photoemission spectroscopy

LaCrO 3 (LCO)/SrTiO 3 (STO) heterojunctions are intriguing due to a polar discontinuity along [001], exhibiting two distinct and controllable charged interface structures [(LaO) + /(TiO 2 ) 0 and (SrO) 0 /(CrO 2 ) - ] with induced polarization, and a resulting depth-dependent potential. In this study, we have used soft- and hard-x-ray standing-wave excited photoemission spectroscopy (SW-XPS) to quantitatively determine the elemental depth profile, interface properties, and depth distribution of the polarization-induced built-in potentials. We observe an alternating charged interface configuration: a positively charged (LaO) + /(TiO 2 ) 0 intermediate layer at the LCO top /STO bottom interface and a negatively charged (SrO) 0 /(CrO 2 ) - intermediate layer at the STO top /LCO bottom interface. Using core-level SW data, we have determined the depth distribution of species, including through the interfaces, and these results are in excellent agreement with scanning transmission electron microscopy and electron energy-loss spectroscopy mapping of local structure and composition. SW-XPS also enabled deconvolution of the LCO and STO contributions to the valence-band (VB) spectra. Using a two-step analytical approach involving first SW-induced core-level binding-energy shifts and then VB modeling, the variation in potential across the complete superlattice is determined in detail. As a result, this potential is in excellent agreement with density functional theory models, confirming this method as a generally useful tool for interface studies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy dependence of kaon-to-proton ratio fluctuations in central Pb+Pb collisions from {radical}(s{sub NN})=6.3 to 17.3 GeV

Kaons and protons carry large parts of two conserved quantities: strangeness and baryon number. It is argued that their correlation and thus also fluctuations are sensitive to conditions prevailing at the anticipated parton-hadron phase boundary. Fluctuations of the (K{sup +}+K{sup -})/(p+p) and K{sup +}/p ratios have been measured for the first time by NA49 in central Pb+Pb collisions at five CERN Super Proton Synchrotron energies between {radical}(s{sub N{sub N}})=6.3 and {radical}(s{sub N{sub N}})=17.3 GeV. Both ratios exhibit a change of sign in {sigma}{sub dyn}, a measure of nonstatistical fluctuations, around {radical}(s{sub N{sub N}})=8 GeV. Below this energy, {sigma}{sub dyn} is positive, indicating higher fluctuation compared to a mixed event background sample, while for higher energies, {sigma}{sub dyn} is negative, indicating correlated emission of kaons and protons. The results are compared to hadronic transport model calculations which fail to reproduce the energy dependence.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical validation of event predictors: A comparative study based on the field of seizure prediction

The prediction of events is of substantial interest in many research areas. To evaluate the performance of prediction methods, the statistical validation of these methods is of utmost importance. Here, we compare an analytical validation method to numerical approaches that are based on Monte Carlo simulations. The comparison is performed in the field of the prediction of epileptic seizures. In contrast to the analytical validation method, we found that for numerical validation methods insufficient but realistic sample sizes can lead to invalid high rates of false positive conclusions. Hence we outline necessary preconditions for sound statistical tests on above chance predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new theory for X-ray diffraction

By considering the scattering distributed throughout space, there is an intensity enhancement at the Bragg angle even when the Bragg condition is not satisfied. This leads to an alternative explanation for the diffraction from powders and small crystals. This article proposes a new theory of X-ray scattering that has particular relevance to powder diffraction. The underlying concept of this theory is that the scattering from a crystal or crystallite is distributed throughout space: this leads to the effect that enhanced scatter can be observed at the ‘Bragg position’ even if the ‘Bragg condition’ is not satisfied. The scatter from a single crystal or crystallite, in any fixed orientation, has the fascinating property of contributing simultaneously to many ‘Bragg positions’. It also explains why diffraction peaks are obtained from samples with very few crystallites, which cannot be explained with the conventional theory. The intensity ratios for an Si powder sample are predicted with greater accuracy and the temperature factors are more realistic. Another consequence is that this new theory predicts a reliability in the intensity measurements which agrees much more closely with experimental observations compared to conventional theory that is based on ‘Bragg-type’ scatter. The role of dynamical effects (extinction etc.) is discussed and how they are suppressed with diffuse scattering. An alternative explanation for the Lorentz factor is presented that is more general and based on the capture volume in diffraction space. This theory, when applied to the scattering from powders, will evaluate the full scattering profile, including peak widths and the ‘background’. The theory should provide an increased understanding of the reliability of powder diffraction measurements, and may also have wider implications for the analysis of powder diffraction data, by increasing the accuracy of intensities predicted from structural models.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron Measurement Instrumentation Development at KIT for the European ITER TBM

Fusion power reactors will rely on the internal production of the fuel tritium from lithium in the tritium breeding blanket. Test Blanket Modules (TBM) will be installed in ITER with the aim to investigate the nuclear performance of different breeding blanket designs. Currently there is no fully qualified nuclear instrumentation available for the measurement of neutron fluxes and tritium production rates which would be able to withstand the harsh environment conditions in the TBM such as high temperature (>400 deg. C) and, depending on the operation scenario, intense radiation levels. As partner of the European Consortium on Nuclear Data and Measurement Techniques in the framework of several F4E specific grants and contracts, KIT and ENEA have jointly studied the possibility to develop and test detectors suitable to operate in ITER-TBMs. Here we present an overview of ongoing work on three types of neutron flux monitors under development for the TBMs with focus on the KIT activities. A neutron activation system (NAS) with pneumatic sample transport could provide absolute neutron flux measurements in selected positions. A test system for investigating activation materials with short half-lives was constructed at the DT neutron generator laboratory of Technical University of Dresden to investigate the neutronics aspects. Several irradiations have been performed with focus on the simultaneous measurement of the extracted activated probes. An engineering assessment of a TBM NAS in the conceptual design phase has been done which considered issues of design requirements and integration. Last but not least, a mechanical test bench is under construction at KIT which will address issues of driving the activation probes, solutions for loading the system etc. experimentally. Self-powered neutron detectors (SPND) are widely applied in fission reactor monitoring, and the commercially available SPNDs are sensitive to thermal neutrons. We are investigating novel materials for SPND which would be sensitive also to the fast neutron flux expected in the TBMs. To this end simulations were done with the European Activation System EASY and neutron flux spectra which were calculated with MCNP for the HCPB TBM. Preliminary tests with commercial SPND in a fast reactor were performed. As a result of these activities, several materials have been found which may be suitable for the measurement of fast neutron fluxes in the TBM. Test detectors are under preparation for testing with DT neutron generators. Within the I{sub S}MART project, funded by KIC InnoEnergy, KIT is developing an online detector based on silicon carbide electronics for the TBMs. The operation of such detectors at TBM relevant temperatures is expected to incur lower accumulated radiation damage to them than at room temperature due to annealing effects. Detectors of several designs have been already irradiated with DT neutrons. Irradiation tests at elevated temperatures have been done and further tests are currently underway. This paper summarizes the status of the work for these three neutron flux monitor systems. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Morphometric Comparison of Clavicle Outlines from 3D Bone Scans and 2D Chest Radiographs: A Short-listing Tool to Assist Radiographic Identification of Human Skeletons

This paper describes a computerized clavicle identification system, primarily designed to resolve the identities of unaccounted for US soldiers who fought in the Korean War. Elliptical Fourier analysis is used to quantify the clavicle outline shape from skeletons and postero-anterior antemortem chest radiographs to rank individuals in terms of metric distance. Similar to leading fingerprint identification systems, shortlists of the top matching candidates are extracted for subsequent human visual assessment. Two independent tests of the computerized system using 17 field-recovered skeletons and 409 chest radiographs demonstrate that true positive matches are captured within the top 5% of the sample 75% of the time. These results are outstanding given the eroded state of some field-recovered skeletons and the faintness of the 1950’s photoflurographs. These methods enhance the capability to resolve several hundred cold cases for which little circumstantial information exists and current DNA and dental record technologies cannot be applied.

computer assisted↗

Growth and coalescence control of inclined c-axis polar and semipolar GaN multilayer structures grown on Si(111), Si(112), and Si(115) by metalorganic vapor phase epitaxy

Herein, silicon substrates in alternative orientations from the commonly used Si(111) were used to enable the growth of polar and semipolar GaN-based structures by the metalorganic vapor phase epitaxy method. Specifically, Si(112) and Si(115) substrates were used for the epitaxial growth of nitride multilayer structures, while the same layer schemes were also deposited on Si(111) for comparison purposes. Multiple approaches were studied to examine the influence of the seed layers and the growth process conditions upon the final properties of the GaN/Si(11x) templates. Scanning electron microscope images were acquired to examine the topography of the deposited samples. It was observed that the substrate orientation and the process conditions allow control to produce an isolated GaN block growth or a coalesced layer growth, resulting in inclined c-axis GaN structures under various forms. The angles of the GaN c-axis inclination were determined by x-ray diffraction measurements and compared with the results obtained from the analysis of the atomic force microscope (AFM) images. The AFM image analysis method to determine the structure tilt was found to be a viable method to estimate the c-axis inclination angles of the isolated blocks and the not-fully coalesced layers. The quality of the grown samples was characterized by the photoluminescence method conducted at a wide range of temperatures from 77 to 297 K, and was correlated with the sample degree of coalescence. Using the free-excitation peak positions plotted as a function of temperature, analytical Bose-Einstein model parameters were fitted to obtain further information about the grown structures.

42 ENGINEERING↗

Compadre Toolkit

The Compadre Toolkit solves a minimization problem, that once solved allows a user to reconstruct a function from sample data collected from a cloud of data sites. The solution to this minimization can also be used to assemble a linear system that can be solved numerically using some other software. The minimization problem the toolkit solves is to find the optimal finite polynomial in a user specified finite dimensional space with regards to minimizing an objective function which measures a linear sampling functional applied to the polynomial, compared to the same sampling functional applied to the source function, weighted by a positive kernel that has compact support.

SciDAC↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

A cell-based Papain-like Protease (PLpro) activity assay for rapid detection of active SARS-CoV-2 infections and antivirals

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its variants are a continuous threat to human life. An urgent need remains for simple and fast tests that reliably detect active infections with SARS-CoV-2 and its variants in the early stage of infection. Here we introduce a simple and rapid activity-based diagnostic (ABDx) test that identifies SARS-CoV-2 infections by measuring the activity of a viral enzyme, Papain-Like protease (PLpro). The test system consists of a peptide that fluoresces when cleaved by SARS PLpro that is active in crude, unprocessed lysates from human tongue scrapes and saliva. Test results are obtained in 30 minutes or less using widely available fluorescence plate readers, or a battery-operated portable instrument for on-site testing. Proof-of-concept was obtained in a study on clinical specimens collected from patients with COVID-19 like symptoms who tested positive (n = 10) or negative (n = 10) with LIAT RT-PCR using nasal mid turbinate swabs. When saliva from these patients was tested with in-house endpoint RT-PCR, 17 were positive and only 5 specimens were negative, of which 2 became positive when tested 5 days later. PLpro activity correlated in 17 of these cases (3 out of 3 negatives and 14 out of 16 positives, with one invalid specimen). Despite the small number of samples, the agreement was significant (p value = 0.01). Two false negatives were detected, one from a sample with a late Ct value of 35 in diagnostic RT-PCR, indicating that an active infection was no longer present. The PLpro assay is easily scalable and expected to detect all viable SARS-CoV-2 variants, making it attractive as a screening and surveillance tool. Additionally, we show feasibility of the platform as a new homogeneous phenotypic assay for rapid screening of SARS-CoV-2 antiviral drugs and neutralizing antibodies.

60 APPLIED LIFE SCIENCES↗

Porewater data across a catena in the Luquillo Experimental Forest, Puerto Rico.

Landscape topography can influence biogeochemical processes in wet tropical forest soils. This dataset contains porewater concentrations of organic acid (acetate) from 2018 (February 22 to November 14) across a catena in the Luquillo Experimental Forest (LEF), Puerto Rico. The attached CSV file contains information on sampling date, location (El Verde field station) in LEF, topographic positions (ridge, slope, and valley, respectively), depth (unit: cm), and acetate concentration (unit: µM). Porewater concentrations of acetate were lower in the valley as compared to the ridge and slope topographic positions. This dataset can facilitate our understanding of the biogeochemical cycling of carbon and nutrient associated with complex topography in wet tropical forest soils.

54 ENVIRONMENTAL SCIENCES↗

Soil chemistry data across a catena in the Luquillo Experimental Forest, Puerto Rico

Landscape topography can influence biogeochemical processes across the wet tropical forest soils. This dataset contains soil chemistry data such as pH and dissolved organic carbon (DOC) from April 1, 2017 to May 1, 2018 across a catena in the Luquillo Experimental Forest, Puerto Rico. The attached CSV file contains information on sampling date, location (El Verde field station) in LEF, topographic positions (ridge, slope, and valley, respectively), field replicate number, laboratory replicate number, water extractable pH, CaCl2 extractable pH, and DOC (unit: mg/g). Overall, soil pH values were highest in the valley, followed by slope, and lowest in the ridge topographic positions. However, DOC values followed the opposite trend: ridge>slope>valley. This dataset can facilitate our understanding of the biogeochemical cycling of carbon and nutrient associated with complex topography in wet tropical forest soils.

54 ENVIRONMENTAL SCIENCES↗

Optoacoustic Microscopy for Investigation of Material Nanostructures-Embracing the Ultrasmall, Ultrafast, and the Invisible

The goal of this grant was the development of a new type of scanning acoustic microscope for nanometer resolution ultrasound imaging, based on ultrafast optoacoustics (>GHz). In the microscope, subpicosecond laser pulses was used to generate and detect very high frequency ultrasound with nanometer wavelengths. We report here on the outcome of the 3-year DOE/BES grant which involved the design, multifaceted construction, and proof-of-concept demonstration of an instrument that can be used for quantitative imaging of nanoscale material features – including features that may be buried so as to be inaccessible to conventional lightwave or electron microscopies. The research program has produced a prototype scanning optoacoustic microscope which, in combination with advanced computational modeling, is a system-level new technology (two patents issues) which offer novel means for precision metrology of material nanostructures, particularly those that are of contemporary interest to the frontline micro- and optoelectronics device industry. For accomplishing the ambitious technical goals, the research roadmap was designed and implemented in two phases. In Phase I, we constructed a “non-focusing” optoacoustic microscope instrument (“POAM”), with nanometer vertical (z-) resolution, while limited to approximately 10 micrometer scale lateral recolution. The Phase I version of the instrument which was guided by extensive acoustic and optical numerical modeling of the basic underlying acoustic and optical physics, featured nanometer scale close loop positioning between the optoacoustic transducer element and a nanostructured material sample under investigation. In phase II, we implemented and demonstrated a scanning version of the instrument (“SOAM”) where incident acoustic energy is focused, and scanned on lateral (x-y) spatial scale in the 100 nm range as per the goals of the project. In so doing we developed advanced numerical simulations to provide computational models of the focusing of multi-GHz acoustic waves to the nanometer scale and innovated a series fabrication approaches for a new type of broadband high-frequency acoustic focusing microscope objective by applying methods on nanoimprinting and focused-ion beam techniques. In the following, the Phase I and Phase II instrument development is reported as Section II. The first segment of this section describes the POAM instrument and its development, while including much of the underlying ultrafast acoustic physics which is common to all of our work for this grant. Then, the science and engineering of the SOAM instrument is described, including the methods of fabricating new types of acoustic microlenses. The results section is followed by reports on publications (Section III), Participants (Section IV), and statement of full use of the allocated grant funds (Section V).

36 MATERIALS SCIENCE↗