Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Environments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Status of the ITER neutral beam injection system (invited)

The ITER neutral beam injectors are the first injectors to be designed to operate under conditions and constraints similar to those that will be encountered with a fusion reactor. The injectors will use a single large ion source and accelerator that will produce 40 A D{sup -} 1 MeV beams for pulse lengths of up to 3600 s. The accelerated ion beams will be neutralized in a gas (D{sub 2}) neutralizer which is subdivided into four vertical channels to reduce the gas flow into the injectors that is needed to produce optimum target for neutralization. These injectors will have to operate in a hostile radiation environment and they will become highly radioactive due to the neutron flux from ITER. The design has been modified recently to have a rectangular vacuum vessel with a removable lid that allows vertical access to, and maintenance of, the beamline components, the incorporation of an absolute all metal valve at the exit of the injector, the choice of a rf driven ion source as the reference design of ion source, and to have a high voltage deck incorporating the various auxiliary power supplies in air rather that under high pressure SF{sub 6}. A major development is that it has been agreed that a Neutral Beam Test Facility (NBTF) will be set up at Padua, Italy. The NBTF will consist of two test beds: one of which will be capable of operating a complete injector at full performance. The second will be an ion source test bed, which will be used for the development and testing, to full performance, of the large negative ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experience On Plasma Diagnostics On JET

This year marks the 30th anniversary of the decision on 17 October 1977 by the European Council of Ministers to proceed with the JET project. Very little thought had been given to the diagnostic requirements during the design phase--indeed many people assumed that JET would not do detailed physics studies and would need only a few basic diagnostics. Of course this view turned out to be incorrect--JET needed a comprehensive set of diagnostics and has conducted a very extensive physics programme. The large physical dimensions of JET, the radiation environment and the stringent interface standards radically changed our concept of diagnostics compared to the smaller fusion experiments that had gone before. In this paper I will review some of the experience on burning plasma diagnostics on JET.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual design of International Linear Collider damping ring wiggler based on a hybrid technology

A magnetic design of a failure-free damping ring wiggler with 100% duty factor, 55.6 mm gap, and field exceeding 1.6 T is proposed. The insertion device is based on permanent magnets and specially shimmed poles that capable to meet the requirements of the International Linear Collider (ILC) damping rings (including positron one), with field quality and gap comparable to that projected for ILC using superconducting wiggler. Performance improvement of the modified hybrid design is attained due to yoke reduction down to six separated strips and maximized packaging of the midgrade (or high-grade) parallelepiped magnet blocks surrounding the Permendur poles. Economical efficiency is demonstrated on the base of calculated amount of magnetic material. A cryogenic variant of the hybrid design may certainly provide good sustainability to harsh radiation environment and further enhancement of the design efficiency within the state of the art.

43 PARTICLE ACCELERATORS↗

Charge transportation and permittivity in electron beam irradiated polymethyl methacrylate

The charging phenomenon in the insulating dielectrics often occurs in the radiative environments such as in the outer space and in the nuclear reactor. Both surface charging and bulk charging have various influences on the dielectric properties. Understanding electrical properties of e-beam irradiated dielectrics is of great significance in order to maintain the stability and reliability of the related operating system. In this work, the effect of electron beam irradiation on the permittivity of polymethyl methacrylate (PMMA) samples was investigated. It was found that the variance of permittivity in e-beam irradiated PMMA is mainly determined by two factors. One is the porosity of the material. The irradiating process could increase the porosity of PMMA due to the escape of the small molecule (e.g., CO, CO{sub 2}, and CH{sub 4}) produced during material degradation caused by e-beam irradiation. The enhanced higher porosity corresponds to lower permittivity. The distribution of the implanted charge is the other factor that influences the permittivity. When the distribution of electric field generated by the accumulating charge is asymmetric for the middle thickness of the sample, the PMMA sample with polar groups would be subjected to extra polarization by the field, which could lead to the increase in permittivity. Combining with the model of Wakino et al. [J. Am. Ceram. Soc. 76, 2588 (1993)] on permittivity of mixture materials, the Clausius-Mosotti equation was utilized to analyze the variation in permittivity in the e-beam irradiated PMMA samples.

36 MATERIALS SCIENCE↗

Directed Neutron Beams From Inverse Kinematic Reactions

Kinematic focusing of an emitted fairly mono-energetic neutron beam by the use of inverse-kinematic reactions, i.e. where the projectile mass is greater than the target atom's mass, can provide for the utilization of a significant fraction of the fast neutron yield and also provide for a safer radiation environment. We examine the merit of various neutron production reactions and consider the practicalities of producing the primary beam using the suitable accelerator technologies. Preliminary progress at the NSWC-Carderock Positive Ion Accelerator Facility is described. Possible important applications for this type of neutron-based system can be both advanced medical imaging techniques and active ''stand-off'' interrogation of contraband items.

43 PARTICLE ACCELERATORS↗

Development of a Negative Hydrogen Ion Source for Spatial Beam Profile Measurement of a High Intensity Positive Ion Beam

We have been developing a negative hydrogen ion (H{sup -} ion) source for a spatial beam profile monitor of a high intensity positive ion beam as a new diagnostic tool. In case of a high intensity continuous-wave (CW) deuteron (D{sup +}) beam for the International Fusion Materials Irradiation Facility (IFMIF), it is difficult to measure the beam qualities in the severe high radiation environment during about one-year cyclic operation period. Conventional techniques are next to unusable for diagnostics in the operation period of about eleven months and for maintenance in the one-month shutdown period. Therefore, we have proposed an active beam probe system by using a negative ion beam and started an experimental study for the proof-of-principle (PoP) of the new spatial beam profile monitoring tool. In this paper, we present the status of development of the H{sup -} ion source as a probe beam source for the PoP experiment.

43 PARTICLE ACCELERATORS↗

A test stand for off-line laser ion source development at TRIUMF

A test stand for ion source development and laser resonance ionization spectroscopy was built and commissioned at TRIUMF. The test stand is needed to develop efficient ion sources that can function reliably in the hostile, high temperature, high radiation environment of TRIUMF's isotope separator on-line (ISOL) production target ion source. In addition, it enables laser resonance ionization spectroscopy to develop laser excitation schemes suitable for the solid-state laser systems used with TRIUMF's resonant ionization laser ion source . Also, it allows for possible improvement of current ion sources and validation of new designs. The test stand employs a copy of the ion optics used on-line, so that results can be transferred directly to radioactive ion beam production. Due to space restrictions and the need for rapid mass scans, a quadrupole mass spectrometer is used as a mass separator. One of the first experiments conducted on the laser ion source test stand (LIS STAND) was resonant ionization spectroscopy of gallium to improve on the ionization scheme previously used on-line, so that low yield isotopes (e.g., {sup 62}Ga) become available for experiments. Different Rydberg series in gallium were observed and autoionizing states were searched for. The overall LIS STAND system performance, characteristics, and the first resonant ionization spectroscopy are described.

74 ATOMIC AND MOLECULAR PHYSICS↗

Note: Readout of a micromechanical magnetometer for the ITER fusion reactor

We present readout instrumentation for a MEMS magnetometer, placed 30 m away from the MEMS element. This is particularly useful when sensing is performed in high-radiation environment, where the semiconductors in the readout cannot survive. High bandwidth transimpedance amplifiers are used to cancel the cable capacitances of several nanofarads. A frequency doubling readout scheme is used for crosstalk elimination. Signal-to-noise ratio in the range of 60 dB was achieved and with sub-percent nonlinearity. The presented instrument is intended for the steady-state magnetic field measurements in the ITER fusion reactor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-scales convergence for optimal and robust quantum transport in photosynthetic complexes

Underlying physical principles for the high efficiency of excitation energy transfer in light-harvesting complexes are not fully understood. Notably, the degree of robustness of these systems for transporting energy is not known considering their realistic interactions with vibrational and radiative environments within the surrounding solvent and scaffold proteins. In this work, we employ an efficient technique to estimate energy transfer efficiency of such complex excitonic systems. We observe that the dynamics of the Fenna-Matthews-Olson (FMO) complex leads to optimal and robust energy transport due to a convergence of energy scales among all important internal and external parameters. In particular, we show that the FMO energy transfer efficiency is optimum and stable with respect to important parameters of environmental interactions including reorganization energy λ, bath frequency cutoff γ, temperature T, and bath spatial correlations. We identify the ratio of k{sub B}λT/ℏγ⁢g as a single key parameter governing quantum transport efficiency, where g is the average excitonic energy gap.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Switching kinetics of SiC resistive memory for harsh environments

Cu/a-SiC/Au resistive memory cells are measured using voltage pulses and exhibit the highest R{sub OFF}/R{sub ON} ratio recorded for any resistive memory. The switching kinetics are investigated and fitted to a numerical model, using thermal conductivity and resistivity properties of the dielectric. The SET mechanism of the Cu/a-SiC/Au memory cells is found to be due to ionic motion without joule heating contributions, whereas the RESET mechanism is found to be due to thermally assisted ionic motion. The conductive filament diameter is extracted to be around 4nm. The high thermal conductivity and resistivity for the Cu/a-SiC/Au memory cells result in slow switching but with high thermal reliability and stability, showing potential for use in harsh environments. Radiation properties of SiC memory cells are investigated. No change was seen in DC sweep or pulsed switching nor in conductive mechanisms, up to 2Mrad(Si) using {sup 60}Co gamma irradiation.

36 MATERIALS SCIENCE↗

Status of neutron diagnostics on the experimental advanced superconducting tokamak

Neutron diagnostics have become a significant means to study energetic particles in high power auxiliary heating plasmas on the Experimental Advanced Superconducting Tokamak (EAST). Several kinds of neutron diagnostic systems have been implemented for time-resolved measurements of D-D neutron flux, fluctuation, emission profile, and spectrum. All detectors have been calibrated in laboratory, and in situ calibration using {sup 252}Cf neutron source in EAST is in preparation. A new technology of digitized pulse signal processing is adopted in a wide dynamic range neutron flux monitor, compact recoil proton spectrometer, and time of flight spectrometer. Improvements will be made continuously to the system to achieve better adaptation to the EAST’s harsh γ-ray and electro-magnetic radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective amorphization of SiGe in Si/SiGe nanostructures via high energy Si+ implant

Here, the selective amorphization of SiGe in Si/SiGe nanostructures via a 1 MeV Si + implant was investigated, resulting in single-crystal Si nanowires (NWs) and quantum dots (QDs) encapsulated in amorphous SiGe fins and pillars, respectively. The Si NWs and QDs are formed during high-temperature dry oxidation of single-crystal Si/SiGe heterostructure fins and pillars, during which Ge diffuses along the nanostructure sidewalls and encapsulates the Si layers. The fins and pillars were then subjected to a 3 × 10 15 ions/cm 2 1 MeV Si + implant, resulting in the amorphization of SiGe, while leaving the encapsulated Si crystalline for larger, 65-nm wide NWs and QDs. Interestingly, the 26-nm diameter Si QDs amorphize, while the 28-nm wide NWs remain crystalline during the same high energy ion implant. This result suggests that the Si/SiGe pillars have a lower threshold for Si-induced amorphization compared to their Si/SiGe fin counterparts. However, Monte Carlo simulations of ion implantation into the Si/SiGe nanostructures reveal similar predicted levels of displacements per cm 3 . Molecular dynamics simulations suggest that the total stress magnitude in Si QDs encapsulated in crystalline SiGe is higher than the total stress magnitude in Si NWs, which may lead to greater crystalline instability in the QDs during ion implant. The potential lower amorphization threshold of QDs compared to NWs is of special importance to applications that require robust QD devices in a variety of radiation environments.

36 MATERIALS SCIENCE↗

Performance of a hardened x-ray streak camera at Lawrence Livermore National Laboratory’s National Ignition Facility

Electron tubes continue to provide the highest speeds possible for recording dynamics of hot high-energy density plasmas. Standard streak camera drive electronics and CCD readout are not compatible with the radiation environment associated with high DT fusion yield inertial confinement fusion experiments >10 13 14 MeV DT neutrons or >10 9 n cm -2 ns -1 . Here, we describe a hardened x-ray streak camera developed for the National Ignition Facility and present preliminary results from the first experiment on which it has participated, recording the time-resolved bremsstrahlung spectrum from the core of an inertial confinement fusion implosion at more than 40× the operational neutron yield limit of the previous National Ignition Facility x-ray streak cameras.

47 OTHER INSTRUMENTATION↗

Temporal evolution of the light emitted by a thin, laser-ionized plasma source

We present an experimental and simulation-based investigation of the temporal evolution of light emission from a thin, laser-ionized helium plasma source. We demonstrate an analytic model to calculate the approximate scaling of the time-integrated, on-axis light emission with the initial plasma density and temperature, supported by the experiment, which enhances the understanding of plasma light measurement for plasma wakefield accelerator (PWFA) plasma sources. Our model simulates the plasma density and temperature using a split-step Fourier code and a particle-in-cell code. A fluid simulation is then used to model the plasma and neutral density, and the electron temperature as a function of time and position. We then show the numerical results of the space-and-time-resolved light emission and that collisional excitation is the dominant source of light emission. We validate our model by measuring the light emitted by a laser-ionized plasma using a novel statistical method capable of resolving the nanosecond-scale temporal dynamics of the plasma light using a cost-effective camera with microsecond-scale timing jitter. This method is ideal for deployment in the high radiation environment of a particle accelerator that precludes the use of expensive nanosecond-gated cameras. Our results show that our models can effectively simulate the dynamics of a thin, laser-ionized plasma source. In addition, this work provides a detailed understanding of the plasma light measurement, which is one of the few diagnostic signals available for the direct measurement of PWFA plasma sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

A novel high frequency, high bandwidth, three phase Mach–Zehnder optical data link

In inertial confinement fusion, hydrogen isotopes are fused together under high pressures and temperatures. Typically, the duration of these experiments is incredibly short, on the order of around 60–150 ps. Due to the high radiation environment, a detector’s signal is typically data linked far distances to a protected location. The diagnostic challenge for fusion reaction history measurements is to measure signals of interest maximizing dynamic range while also maintaining time resolution on the order of 10 ps. In this work, we present a new experimental optical data link used to efficiently transport diagnostic signals over great distances to the recording system while not restricting the dynamic range. The concept of a three phase Mach–Zehnder modulator system is introduced as well as a description of the physical prototype. The initial results from testing at the OMEGA facility show that this system is a viable method for signal transportation.

47 OTHER INSTRUMENTATION↗