Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

A hardware-based heat pump water heater design model for quasi-steady-state simulation

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared to electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), a component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model and a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. In the paper, the new HPWH system design model was used to investigate effects of compressor size, refrigerant charge, water draw pattern, and refrigerant type, etc., for predicting 24-hour energy factors and first-hour rating. The HPWH system model was proved to be an effective equipment design tool.

Shen, Bo↗

Systems and methods for flow-synchronous field motion heat transfer

An active regenerator in a magnetocaloric or an electrocaloric heat pump refrigeration system provides more efficient flow of heat. The heat exchange fluid moves synchronously with the motion of a magnetic or electric field. Only a portion of the length of the active regenerator bed is introduced to or removed from the field at one time, giving rise to a hot pulse and a cold pulse. Valves may direct the hot pulse and/or the cold pulse to supplement refrigeration.

Hassen, Charles N.↗

Compounds, complexes, compositions, methods and systems for heating and cooling

Disclosed herein are ionic liquid compounds, complexes and compositions suitable for use as refrigerants. Methods and systems for heating and/or cooling, including vapor compression heating or cooling systems, including such refrigerants are also disclosed. Preferred ionic liquids include those having anions selected from pyrrolide, pyrazolide, triazolide, imidazolide, benzimidazolide, and indolide, and cations selected from phosphonium, ammonium, pyrrolidinium, imidazolium, and pyridinium.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact SRF based accelerator

An accelerator comprising at least one accelerator cavity, an electron gun, at least one cavity cooler configured to at least partially encircle the accelerator cavity, a cooling connector, an intermediate conduction layer formed between the at least one cavity cooler and the at least one accelerator cavity configured to facilitate thermal conductivity between the cavity cooler and the accelerator cavity, a mechanical support connected to the accelerator cavity via at least one endplate and configured for stabilizing the accelerator cavity, and a refrigeration source for providing refrigerant via the cooling connector to the at least one cavity cooler.

43 PARTICLE ACCELERATORS↗

Design of the DUNE APATF cryogenic system

Fermi National Accelerator Laboratory (FNAL) is developing the international Long- Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) to advance neutrino science. The flagship of the DUNE project consists of a large particle detector constructed one-mile (1.6 km) beneath the surface at the Sanford Underground Research Facility (SURF) in Lead, SD. The SURF detector is the largest of its type ever built and is comprised of four cryostats totaling 70,000 tons of liquid argon (LAr) to record neutrino interactions with unprecedented precision. Each cryostat houses a detector, the first includes 150 Anode Panel Assemblies (APA) submersed within 17,500 tons of LAr. Before installing 150 APA within the SURF detector they will be cryogenically cooled to nominally 90 K at the APA Test Facility (APATF) utilizing nitrogen flows. The APATF cryogenic system is entirely located one-mile underground at the SURF facility and includes nominally 13 kW of refrigeration at 80 K, cryogenic transfer lines, APA test cryostats, a cryogenic control system, and various control and pressure safety elements to ensure performance and safety requirements are achieved. The APATF preliminary design is in progress and major considerations include an efficient, costeffective mechanism to deliver the required refrigeration to the APATF underground, support of rigid testing intervals to support the DUNE operating schedule, temperature stability of the APA and electronics within cryostats, efficient cryogenic system operation to minimize heat leak and/or liquid nitrogen consumption, thermo-mechanical stability and flexibility of components, and pressure safety of the APATF cryogenic system. Installation and integration of the APATF cryogenic system within the footprint and to adjacent sub-systems is also discussed.

43 PARTICLE ACCELERATORS↗

Development of Two-Phase Dense Fluid Expander for Advanced Cryogenic Air Separation and Low-Grade Heat Recovery

Cryogenic air separation represents the state-of-the-art technology to produce oxygen to feed coal gasification units. Given the maturity of this technology, it is difficult to identify opportunities to improve process efficiency and reduce the cost of the oxygen produced. However, Air Products conducted research and a feasibility investigation into the use of a two-phase (liquid-vapor) dense fluid expander (DFE) to improve the overall efficiency of cryogenic air separation. Demonstration of this novel concept was intended to allow two important process improvements: 1) elimination of the need for the DFE discharge to be single phase 2) expansion of the operating region of expanders in ASU service. Expanding the scope of turboexpander application beyond current application limits and traditional device designs would allow an increase in power recovery, and application of refrigeration and power recovery at new locations in process cycles would also enable the implementation of new process concepts. These new process concepts include power recovery from compression waste heat and refrigeration extraction and power recovery by replacing let-down valves with two-phase DFEs. Considering the maturity of cryogenic air separation, these new process options could represent a step change in power reduction and provide significant savings in operating costs. These new concepts would be particularly well-suited to large-scale oxygen production by cryogenic air separation and would enhance the economics of producing oxygen for use in coal gasification processes. Rotoflow, an Air Products business unit, manufactures dense fluid expanders in Pennsylvania for sites around the world. This project was executed in two phases, which are illustrated in Figure 1 below. Phase 1 consisted of a feasibility investigation of multiple applications of two-phase DFEs. In Phase 2, devices were identified, designed, fabricated and tested to explore the feasibility of commercial applications of DFEs operating in two-phase service. Engineering and testing were performed by personnel in Air Products’ Rotoflow business unit, with coordination with other Air Products business units.

01 COAL, LIGNITE, AND PEAT↗

Free-space confocal magneto-optical spectroscopies at milliKelvin temperatures

We describe the operation of a free-space confocal optical microscope operated in a dilution refrigerator. The microscope is installed on a cold insertable probe to enable fast sample exchange while the refrigerator is held at low temperatures. A vector magnet provides a 6 T field normal to the sample and 1 T fields at arbitrary angles. A variety of optical microscopies and spectroscopies, including photoluminescence, Raman, magneto-optical Kerr effect, and spin relaxometry measurements are described, and some of the challenges associated with performing these measurements at milliKelvin temperatures are explored.

Lawrie, Benjamin↗

Compact SRF based accelerator

An accelerator comprising at least one accelerator cavity, an electron gun, at least one cavity cooler configured to at least partially encircle the accelerator cavity, a cooling connector, an intermediate conduction layer formed between the at least one cavity cooler and the at least one accelerator cavity configured to facilitate thermal conductivity between the cavity cooler and the accelerator cavity, a mechanical support connected to the accelerator cavity via at least one endplate and configured for stabilizing the accelerator cavity, and a refrigeration source for providing refrigerant via the cooling connector to the at least one cavity cooler.

Kephart, Robert↗

Adsorption cooling system using carbon aerogel

A highly adsorptive structure includes: a substrate; and a carbon aerogel adhered to the substrate, wherein the carbon aerogel is characterized by having physical characteristics of in-situ formation on the substrate, and wherein the carbon aerogel is configured to selectively adsorb and desorb one or more refrigerants selected from the group consisting of: acid halides, alcohols, aldehydes, amines, chlorofluorocarbons, esters, ethers, fluorocarbons, perfluorocarbons, halocarbons, halogenated aldehydes, halogenated amines, halogenated hydrocarbons, halomethanes, hydrocarbons, hydrochlorofluorocarbons, hydrofluoroethers, hydrofluoroolefins, inorganic gases, ketones, nitrocarbon compounds, noble gases, organochlorine compounds, organofluorine compounds, organophosphorous compounds, organosilicon compounds, oxide gases, refrigerant blends and thiols.

Baumann, Theodore F.↗

Adsorption cooling system using carbon aerogel

An adsorptive cooling system includes: a first highly adsorptive structure positioned to receive thermal energy from a thermal energy source, the first highly adsorptive structure including: a first substrate; and a first carbon aerogel adhered to the first substrate, a second highly adsorptive structure positioned to receive thermal energy from the thermal energy source, the second highly adsorptive structure including: a second substrate; and a second carbon aerogel adhered to the second substrate, a cooling unit; and a circulation system adapted for circulating the refrigerant from at least one of the first highly adsorptive structure and the second highly adsorptive structure to the cooling unit to provide cooling from the thermal energy source and to return the refrigerant from the cooling unit to at least one of the first highly adsorptive structure and the second highly adsorptive structure.

Baumann, Theodore F.↗

Integrated Thermal Energy Storage System for Air-Conditioners with Phase-Change Composites

Thermal energy storage (TES) is a promising solution to store and dispatch energy and shave peak electric load, reducing the operational cost of HVAC systems. We present results of a TES system using phase-change materials (PCM) integrated with an air conditioner. The proposed system uses an organic PCM (tetradecane) encapsulated within compressed expanded natural graphite foams referred to as phase-change composite. The graphite foam encapsulates the PCM eliminating the need for expensive storage vessels, reduces installation costs, and provides higher thermal conductivity that can lead to faster charge/discharge rates. Two serpentines, multi-pass circuits, operating as a heat source and a sink, exchange heat to and from the phase-change composite. These two circuits are embedded in multiple slabs of this material. The "charge" circuit contains the refrigerant that is directly coupled to a vapor compression system, and the "discharge" circuit removes heat from an airstream and releases it into the PCM composite through a water-glycol liquid coupling. This configuration allows for multiple modes of operation depending on the state of charge of the thermal energy storage module, the building air-conditioning load, and the current electricity and demand charges. This flexible operation allows variable air volume capacity control without the need to have a variable capacity refrigeration system. We developed a 21 kW-hr (6 RT-hr) prototype TES system coupled with a commercial air-conditioner to characterize the component-and system-level performance.

air-conditioning↗

Modeling and Simulation of Air-Source CO2 Heat Pump Water Heater

Carbon dioxide (CO2) has been widely used as working fluid for the vapor-compression refrigeration systems in large marine device. Due to the potential energy efficiency and the favorable environmental properties of CO2 as a working fluid, CO2 heat pump water heater (HPWH) systems are regarded a promising technology for centralized domestic hot water (DHW) heating in residential and commercial buildings. However, there is still at the early stage of appropriately optimizing and improving the energy performance of CO2 HPWH. This requires CO2 HPWH simulation tools capable of capturing the accurate impact of the emerging compressor, throttle device, and heat exchanger technology on CO2 heat transfer and energy efficiency. In this study, high efficiency components (compressors, pumps, fans, heat exchangers) were identified and applied to the state-of-art CO2 HPWH designs and analyzed their performance by using numerical simulation. This was done by simulating the performance of CO2 HPWH using ACMODEL design model combined with the component models developed at Oak Ridge National Laboratory (ORNL) for orifice tube, map-based compressor, and tube-in-tube gas cooler. ACMODEL is an equipment design model for CO2-based air conditioners and heat pumps developed by Purdue University to account for the details of each component. The simulated CO2 HPWH performance was then compared with the heat pump water heater using conventional refrigerants.

Gao, Zhiming↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Active magnetic regenerative processes and systems employing hydrogen as heat transfer fluid and process gas

A system including:an active magnetic regenerative refrigerator apparatus that includes a high magnetic field section in which a hydrogen heat transfer fluid can flow from a cold side to a hot side through at least one magnetized bed of at least one magnetic refrigerant, and a low magnetic field or demagnetized section in which the hydrogen heat transfer fluid can flow from a hot side to a cold side through the demagnetized bed;a first conduit fluidly coupled between the cold side of the low magnetic field or demagnetized section and the cold side of the high magnetic field section; anda second conduit fluid coupled to the first conduit, an expander and at least one liquefied hydrogen storage module.

Holladay, Jamie D.↗

Electrochemical Ammonia Compression

An electrochemical (EC) compressor is a solid-state compression device. For decades, researchers have been studying EC compressors for applications for a variety of energy systems. As the world transitions away from fossil fuel energy sources, EC compression emerges as a promising technique for energy storage, specifically energy stored in the form of pressurized ammonia. Ammonia is also a commonly used refrigerant. The present studies examine the viability of EC compression for ammonia storage and refrigeration. EC ammonia compression increases the concentration of an ammonia-hydrogen mixture via the input of electrical energy and a series of chemical reactions. A polymer electrolyte membrane separates the low-concentration side from the high-concentration side of the device. On the low-pressure (anode) side hydrogen atoms oxidize and react with ammonia molecules, forming positively charge ammonium ions. The ions traverse the membrane electrolytically. The ammonium ions are reduced and revert back to hydrogen and ammonia upon reaching the high-pressure (cathode). An external circuit provides the current needed to sustain the reactions. In this project, we studied the performance of the ammonia EC compressor under a variety of different conditions. We replicated preliminary data and using a small cell with 5 cm2 of active area. We demonstrated the operation of larger cells with 100 cm2 of active area. Further, we used a commercially available hydrogen EC compressor stack to analyze the scaled-up compressor performance. While previous experiments examined only the transient EC compressor performance, we developed test facilities that allowed the compressor to reach steady state. We analyzed the effects of pressure and current on the EC compressor performance. We measured the flow rates of gas leaving the compressors and analyzed the composition using gas chromatography. We tested methods of separating ammonia from the effluent vapor, which contained hydrogen and water vapor. We found that back diffusion adversely affected the performance, especially when we maintained high pressure lifts.

25 ENERGY STORAGE↗

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

43 PARTICLE ACCELERATORS↗

A Propane Hydronic Heat Pump with Energy Storage

Propane is an environment-friendly refrigerant, having a 20-year GWP (global warming potential) of 0.072 and a 100-year GWP of 0.02, as compared to R-410A having a GWP > 2000. It has superior thermodynamic cycle performance and heat transfer characteristics. However, propane is classified as a A3 refrigerant, which is highly flammable, and not allowed to be used indoor if the system charge is higher than 150 grams. It is a challenge to use propane in residential applications requiring a rated capacity larger than 10 k Watts. A hydronic heat pump, i.e., containing propane in an outdoor unit and distributing the cooling and heating capacity through a hydronic coil to the indoor space addresses the flammability issue, while maintaining a high efficiency. We developed a hydronic heat pump with propane, it uses a two-stage compressor, a brazed plate indoor heat exchanger, and a microchannel outdoor heat exchanger. It achieves a rated cooling capacity larger than 10 k Watts, and a cooling SEER (cooling seasonal energy efficiency rating) > 16.0 (cooling seasonal COP > 4.7) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP > 2.78), while requiring a system charge < 1200 grams. Additionally, the hydronic heat pump was evaluated in a laboratory water heating loop to heat a 50-gallon water tank in a full condensing mode. Experiments of heating the tank water from 58F(14.4°C) to 150F(65.6°C) were conducted under ambient temperatures from 17F(-8.3°C) to 75F(23.9°C), at the compressor high and low stages.

Shen, Bo↗

Heat pumps in the United States: Market potentials, challenges and opportunities, technology advances

The US heat pump market has been affected by the socioeconomic impacts of the COVID-19 pandemic. However, the Biden administration’s goal of net-zero greenhouse gas emissions by 2050 through electrification and clean energy technologies is accelerating the research, development, and deployment of heat pumps in the United States for improved energy performance, reduced greenhouse gas emissions, and wider adoption. The US heat pump market has experienced steady growth since 2010. In 2020, heat pumps surpassed gas furnace shipments for the first time, and the trend maintains through 2022. The current priority is to improve the affordability of energy and equitable access to heat pump technologies through cost reductions and further accelerate this trend. In addition, current R&D includes emphases on alternative refrigeration technology and lower–global warming potential refrigerants to reduce direct emissions. Heat pump market share is expected to grow as regulatory policies and financial incentives steer the building sector toward decarbonization. This paper reviews policies and market trends, discusses the challenges and opportunities in the current policy landscape, and reviews current research in the United States.

Malhotra, Mini↗