Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Radiation Anomaly Detection and Classification with Bayes Model Selection

We present a new method for radiation anomaly detection that is based on Bayes Model Selection (BMS), together with models for gamma-radiation measurements from benign and threat sources. The method estimates the relative odds of pairs of such models, with the aim of supporting related hypotheses about the nature of the underlying source material. We also discuss partial optimization of the parameters in the models. The method allows measurements to be broadly categorized and screened for sources of interest in real time, a property that should improve the efficiency of mobile search or unattended monitoring operations.

Anomaly detection, Gamma-ray spectroscopy, Radiati↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Non-contact Real-time Target Health Monitor

Targets are an essential part of many accelerator-based experiments, yet their constant radiation exposure eventually affects their internal structure and, consequently, their properties. Current methods typically involve either direct contact with the target or complete removal of the system, which may not be the most efficient for assessing radiation damage. For this reason, a system has been proposed that will monitor a target s radiation damage without the need for direct contact or removal. This sensor will achieve this by measuring the reflectivity of S- and P-polarized waves, which are expected to change measurably due to radiation-induced alterations. As is commonly done, smaller-scale tests were performed to ensure that the necessary equipment was functioning correctly. Once all equipment is tested, the next step will be to perform reflectivity measurements using a tungsten sample, a material often used in targets. Longer-term work will involve scaling up the system and implementing higher-energy beams. This sensor will enable a more comprehensive study of radiation damage in materials and is being considered for projects such as Mu2e, Mu2e-II, LBNF, AMF, and muon colliders.

Agosto Reyes, Alanice↗

Mass extinction efficiency and extinction hygroscopicity of ambient PM{sub 2.5} in urban China

The ambient PM{sub 2.5} pollution problem in China has drawn substantial international attentions. The mass extinction efficiency (MEE) and hygroscopicity factor (f(RH)) of PM{sub 2.5} can be readily applied to study the impacts on atmospheric visibility and climate. The few previous investigations in China only reported results from pilot studies and are lack of spatial representativeness. In this study, hourly average ambient PM{sub 2.5} mass concentration, relative humidity, and atmospheric visibility data from China national air quality and meteorological monitoring networks were retrieved and analyzed. It includes 24 major Chinese cities from nine city-clusters with the period of October 2013 to September 2014. Annual average extinction coefficient in urban China was 759.3±258.3 Mm{sup −1}, mainly caused by dry PM{sub 2.5} (305.8.2±131.0 Mm{sup −1}) and its hygroscopicity (414.6±188.1 Mm{sup −1}). High extinction coefficient values were resulted from both high ambient PM{sub 2.5} concentration (68.5±21.7 µg/m{sup 3}) and high relative humidity (69.7±8.6%). The PM{sub 2.5} mass extinction efficiency varied from 2.87 to 6.64 m{sup 2}/g with an average of 4.40±0.84 m{sup 2}/g. The average extinction hygroscopic factor f(RH=80%) was 2.63±0.45. The levels of PM{sub 2.5} mass extinction efficiency and hygroscopic factor in China were in comparable range with those found in developed countries in spite of the significant diversities among all 24 cities. Our findings help to establish quantitative relationship between ambient extinction coefficient (visual range) and PM{sub 2.5} & relative humidity. It will reduce the uncertainty of extinction coefficient estimation of ambient PM{sub 2.5} in urban China which is essential for the research of haze pollution and climate radiative forcing. - Highlights: • Data from air quality and meteorological monitoring networks were combined. • MEE and hygroscopicity of PM{sub 2.5} in China was similar to that of developed countries. • High extinction coefficient was dominated by both high PM{sub 2.5} and relative humidity.

54 ENVIRONMENTAL SCIENCES↗

Systematic Review of Radiation Therapy Toxicity Reporting in Randomized Controlled Trials of Rectal Cancer: A Comparison of Patient-Reported Outcomes and Clinician Toxicity Reporting

The use of multimodal treatments for rectal cancer has improved cancer-related outcomes but makes monitoring toxicity challenging. Optimizing future radiation therapy regimens requires collection and publication of detailed toxicity data. This review evaluated the quality of toxicity information provided in randomized controlled trials (RCTs) of radiation therapy in rectal cancer and focused on the difference between clinician-reported and patient-reported toxicity. Medline, EMBASE, and the Cochrane Library were searched (January 1995-July 2013) for RCTs reporting late toxicity in patients treated with regimens including preoperative (chemo)radiation therapy. Data on toxicity measures and information on toxicity reported were extracted using Quantitative Analyses of Normal Tissue Effects in the Clinic recommendations. International Society for Quality of Life Research standards on patient-reported outcomes (PROs) were used to evaluate the quality of patient-reported toxicity. Twenty-one RCT publications met inclusion criteria out of 4144 articles screened. All PRO studies reported higher rates of toxicity symptoms than clinician-reported studies and reported on a wider range and milder symptoms. No clinician-reported study published data on sexual dysfunction. Of the clinician-reported studies, 55% grouped toxicity data related to an organ system together (eg “Bowel”), and 45% presented data only on more-severe (grade ≥3) toxicity. In comparison, all toxicity grades were reported in 79% of PRO publications, and all studies (100%) presented individual symptom toxicity data (eg bowel urgency). However, PRO reporting quality was variable. Only 43% of PRO studies presented baseline data, 28% did not use any psychometrically validated instruments, and only 29% of studies described statistical methods for managing missing data. Analysis of these trials highlights the lack of reporting standards for adverse events and reveals the differences between clinician and patient reporting of toxicity. Recommendations for improving the quality of adverse event data collection are provided, with the aim of improving critical appraisal of outcomes for future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Point-Source Injection Methodologies on Injection Studies

Effective interdiction of illicit radioactive material requires detection algorithms that are sensitive to material of interest while insensitive to material of no interest. Injection studies are used to assess the detection sensitivities to threat scenarios by various detection algorithms. In injection studies, gamma-ray spectra for varying source strengths representing particular radioisotopes and shielding configurations are added to archived vehicle count time-profiles. Observed alarm rates are calculated and analyzed to address experimental questions. Numerous decisions need to be made about configuring injection studies, including two important methodological factors that emulate actual field conditions: point-source position and temporal shape. Understanding the relative impact of different methods on outcome measures is vital for comparing results of injection studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of computed radiography plates to determine light and radiation field coincidence

Purpose: Photo-stimulable phosphor computed radiography (CR) has characteristics that allow the output to be manipulated by both radiation and optical light. The authors have developed a method that uses these characteristics to carry out radiation field and light field coincidence quality assurance on linear accelerators.Methods: CR detectors from Kodak were used outside their cassettes to measure both radiation and light field edges from a Varian linear accelerator. The CR detector was first exposed to a radiation field and then to a slightly smaller light field. The light impinged on the detector's latent image, removing to an extent the portion exposed to the light field. The detector was then digitally scanned. A MATLAB-based algorithm was developed to automatically analyze the images and determine the edges of the light and radiation fields, the vector between the field centers, and the crosshair center. Radiographic film was also used as a control to confirm the radiation field size.Results: Analysis showed a high degree of repeatability with the proposed method. Results between the proposed method and radiographic film showed excellent agreement of the radiation field. The effect of varying monitor units and light exposure time was tested and found to be very small. Radiation and light field sizes were determined with an uncertainty of less than 1 mm, and light and crosshair centers were determined within 0.1 mm.Conclusions: A new method was developed to digitally determine the radiation and light field size using CR photo-stimulable phosphor plates. The method is quick and reproducible, allowing for the streamlined and robust assessment of light and radiation field coincidence, with no observer interpretation needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

Effects of gamma-Radiation on Select Lipids and Antioxidants

Radiation encountered on an extended duration space mission (estimates of 3 Sieverts for a mission to Mars) poses a threat not only to human health, but also to the quality, nutritional value, and palatability of the food system. Free radicals generated by radiation interaction with foods may initiate many unwanted reactions including: 1) autoxidation in lipids that alters flavor, odor, and concentrations of essential fatty acids, and 2) depletion of antioxidants food products and dietary supplements. Studies have shown that antioxidants may provide long term health protection from oxidative stress caused by radiation exposure; therefore, consumption of antioxidants will be important. Stability of essential fatty acids is also important for astronauts long-term health status. The objectives of this study were to characterize the effects of low dose gamma-radiation on lipids and antioxidants by monitoring oxidation and reducing power, respectively, in model systems. Select oils and antioxidants were exposed to levels of gamma-radiation ranging from 0 to 1000 Gy (1 Gy = 1 Sv) using a Gammacell 220 and stored at ambient or elevated temperatures (65 C) for up to 3 months prior to analysis. A Fricke dosimeter was used to verify differences between the radiation doses administered. Primary and secondary products of lipid oxidation in soybean and peanut oils were monitored using conjugated diene and 2-thiobarbituric acid (TBARs) assays. Changes in fatty acid composition and formation and vitamin E levels were also measured. The reducing power of antioxidant compounds, including vitamins C and E and beta-carotene, was determined using the ferric reducing antioxidant power (FRAP) assay. Significant differences (alpha =0.05) were present between all radiation doses tested using the Fricke dosimeter. Increasing radiation doses above 3 Sv resulted in significantly (alpha =0.05) elevated levels of oxidation and free fatty acids in soybean and peanut oils. Decreases in concentrations of essential fatty acids upon increasing radiation doses were also observed. Increasing radiation doses caused significant (alpha =0.05) decreases in reducing power and hence the effectiveness of vitamins C and E as well as beta-carotene. This work establishes a need for quantifying the effects of space relevant radiation doses in the development of a food system for an extended duration mission and for identifying threshold radiation levels that will impact the useful shelf-life of the variety of foods that will be sent. Eventual rancidity of lipids and the loss of antioxidant bioprotective effects are major concerns for the acceptability and nutritional profile of a food system.

Gandolph, Jacob↗

Modeling and characterization of the Earth Radiation Budget Experiment (ERBE) nonscanner and scanner sensors

The Earth Radiation Budget Experiment (ERBE) is making high-absolute-accuracy measurements of the reflected solar and Earth-emitted radiation as well as the incoming solar radiation from three satellites: ERBS, NOAA-9, and NOAA-10. Each satellite has four Earth-looking nonscanning radiometers and three scanning radiometers. A fifth nonscanner, the solar monitor, measures the incoming solar radiation. The development of the ERBE sensor characterization procedures are described using the calibration data for each of the Earth-looking nonscanners and scanners. Sensor models for the ERBE radiometers are developed including the radiative exchange, conductive heat flow, and electronics processing for transient and steady state conditions. The steady state models are used to interpret the sensor outputs, resulting in the data reduction algorithms for the ERBE instruments. Both ground calibration and flight calibration procedures are treated and analyzed. The ground and flight calibration coefficients for the data reduction algorithms are presented.

Halyo, Nesim↗

Advanced Semiconductor Dosimetry in Radiation Therapy

Modern radiation therapy is very conformal, resulting in a complexity of delivery that leads to many small radiation fields with steep dose gradients, increasing error probability. Quality assurance in delivery of such radiation fields is paramount and requires real time and high spatial resolution dosimetry. Semiconductor radiation detectors due to their small size, ability to operate in passive and active modes and easy real time multichannel readout satisfy many aspects of in vivo and in a phantom quality assurance in modern radiation therapy. Update on the recent developments and improvements in semiconductor radiation detectors and their application for quality assurance in radiation therapy, based mostly on the developments at the Centre for Medical Radiation Physics (CMRP), University of Wollongong, is presented.

61 RADIATION PROTECTION AND DOSIMETRY↗

X-ray Spontaneous Emission Control By 1D-PBG Structure

The control of the decay rate of an excited atom through the photonic mode density (PMD) was pointed out at radiofrequency by Purcell in 1946. Nowadays the development of sophisticated photonic band structures makes it possible to monitor the PMD at shorter radiation wavelengths and then to manipulate the spontaneous emission of atoms in the hard region of the electromagnetic spectrum especially in the visible domain. In this communication we study the possibility of monitoring the x-ray emission by means of one-dimensional photonic band structures such as periodic multilayer systems. Enhancement or inhibition of soft x-ray emissions seems now to be feasible by means of the state-of-the art in x-ray optics.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-D-210-06: Feasibility for Monitoring the Head of the Pancreas Motion Through a Surrogate Using Ultrasound During Radiation Therapy Delivery

Purpose: Substantial target motion during the delivery of radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor on RT effectiveness. The aim of this work is to monitor intra-fractional motion of the pancreas using ultrasound during RT delivery. Methods: Transabdominal Ultrasound B-mode images were collected from 5 volunteers using a research version of the Clarity Autoscan System (Elekta). The autoscan transducer with center frequency of 5 MHz was utilized for the scans. Imaging parameters were adjusted to acquire images at the desired depth with good contrast and a wide sweep angle. Since well-defined boundaries of the pancreas can be difficult to find on ultrasound B-mode images, the portal vein was selected as a surrogate for motion estimation of the head of the pancreas. The selection was due to its anatomical location posterior to the neck of the pancreas and close proximity to the pancreas head. The portal vein was contoured on the ultrasound images acquired during simulation using the Clarity Research AFC Workstation software. Volunteers were set up in a similar manner to the simulation for their monitoring session and the ultrasound transducer was mounted on an arm fixed to the couch. A video segment of the portal vein motion was captured. Results: The portal vein was visualized and segmented. Successful monitoring sessions of the portal vein were observed. In addition, our results showed that the ultrasound transducer itself reduces breathing related motion. This is analogous to the use of a compression plate to suppress respiration motion during thorax or abdominal irradiation. Conclusion: We demonstrate the feasibility of tracking the pancreas through the localization of the portal vein using abdominal ultrasound. This will allow for real-time tracking of the intra-fractional motion to justify PTV-margin and to account for unusual motions, thus, improving normal tissue sparing. This research was funding in part by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Multi-MGy Radiation Hardened Camera for Nuclear Facilities

There is an increasing interest in developing cameras for surveillance systems to monitor nuclear facilities or nuclear waste storages. Particularly, for today's and the next generation of nuclear facilities increasing safety requirements consecutive to Fukushima Daiichi's disaster have to be considered. For some applications, radiation tolerance needs to overcome doses in the MGy(SiO{sub 2}) range whereas the most tolerant commercial or prototypes products based on solid state image sensors withstand doses up to few kGy. The objective of this work is to present the radiation hardening strategy developed by our research groups to enhance the tolerance to ionizing radiations of the various subparts of these imaging systems by working simultaneously at the component and system design levels. Developing radiation-hardened camera implies to combine several radiation-hardening strategies. In our case, we decided not to use the simplest one, the shielding approach. This approach is efficient but limits the camera miniaturization and is not compatible with its future integration in remote-handling or robotic systems. Then, the hardening-by-component strategy appears mandatory to avoid the failure of one of the camera subparts at doses lower than the MGy. Concerning the image sensor itself, the used technology is a CMOS Image Sensor (CIS) designed by ISAE team with custom pixel designs used to mitigate the total ionizing dose (TID) effects that occur well below the MGy range in classical image sensors (e.g. Charge Coupled Devices (CCD), Charge Injection Devices (CID) and classical Active Pixel Sensors (APS)), such as the complete loss of functionality, the dark current increase and the gain drop. We'll present at the conference a comparative study between these radiation-hardened pixel radiation responses with respect to conventional ones, demonstrating the efficiency of the choices made. The targeted strategy to develop the complete radiation hard camera electronics will be exposed. Another important element of the camera is the optical system that transports the image from the scene to the image sensor. This arrangement of glass-based lenses is affected by radiations through two mechanisms: the radiation induced absorption and the radiation induced refractive index changes. The first one will limit the signal to noise ratio of the image whereas the second one will directly affect the resolution of the camera. We'll present at the conference a coupled simulation/experiment study of these effects for various commercial glasses and present vulnerability study of typical optical systems to radiations at MGy doses. The last very important part of the camera is the illumination system that can be based on various technologies of emitting devices like LED, SLED or lasers. The most promising solutions for high radiation doses will be presented at the conference. In addition to this hardening-by-component approach, the global radiation tolerance of the camera can be drastically improve by working at the system level, combining innovative approaches eg. for the optical and illumination systems. We'll present at the conference the developed approach allowing to extend the camera lifetime up to the MGy dose range. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-Wavelength Approach for Aerosol-Cloud Discrimination in the Sage III/ISS Aerosol Extinction Dataset

The tropical upper troposphere and lower stratosphere (UTLS) region is dominated by aerosols and clouds affecting Earth’s radiation budget and climate. Thus, satellites’ continuous monitoring and identification of these layers is crucial for quantifying their radiative impact. However, distinguishing between aerosols and clouds is challenging, especially under the perturbed UTLS conditions during post-volcanic eruptions and wildfire events. Aerosol-cloud discrimination is primarily based on their disparate wavelength-dependent scattering and absorption properties. In this study, we use aerosol extinction observations in the tropical (15°N-15°S) UTLS from June 2017 to February 2021, available from the latest generation of the Stratospheric Aerosol and Gas Experiment (SAGE) instrument-SAGE III onboard the International Space Station (ISS) to study aerosols and clouds. During this period, the SAGE III/ISS provided better coverage over the tropics at additional wavelength channels (relative to previous SAGE missions) and witnessed several volcanic and wildfire events that perturbed the tropical UTLS. We explore the advantage of having an extinction coefficient at an additional wavelength channel (1550 nm) from the SAGE III/ISS in aerosol-cloud discrimination using a method based on thresholds of two extinction coefficient ratios, R1R1 (520 nm/1020 nm) and R2R2 (1020 nm/1550 nm). This method was proposed earlier by Kent et al. [Appl. Opt. 36, 8639 (1997) [CrossRef] ] for the SAGE III-Meteor-3M but was never tested for the tropical region under volcanically perturbed conditions. We call this method the Extinction Color Ratio (ECR) method. The ECR method is applied to the SAGE III/ISS aerosol extinction data to obtain cloud-filtered aerosol extinction coefficients, cloud-top altitude, and seasonal cloud occurrence frequency during the entire study period. Cloud-filtered aerosol extinction coefficient obtained using the ECR method revealed the presence of enhanced aerosols in the UTLS following volcanic eruptions and wildfire events consistent with the Ozone Mapping and Profiler Suite (OMPS) and space-borne lidar-Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP). The cloud-top altitude obtained from the SAGE III/ISS is within 1 km of the nearly co-located observations from OMPS and CALIOP. In general, the seasonal mean cloud-top altitude from the SAGE III/ISS events peaks during the December, January, and February months, with sunset events showing higher cloud tops than the sunrise events, indicating the seasonal and diurnal variation of the tropical convection. The seasonal altitude distribution of cloud occurrence frequency obtained from the SAGE III/ISS also agrees well with CALIOP observations within 10%. We show that the ECR method is a simple approach that relies on thresholds independent of the sampling period, providing cloud-filtered aerosol extinction coefficients uniformly for climate studies irrespective of the UTLS conditions. However, since the predecessor of SAGE III did not include a 1550 nm channel, the usefulness of this approach is limited to short-term climate studies after 2017.

Clouds Aerosols↗

How Does the Sun's Spectrum Vary?

Recent observations made by the Spectral Irradiance Monitor (SIM) on the Solar Radiation and Climate Experiment (SORCE) spacecraft suggest that the Sun's visible and infrared spectral irradiance increased from 2004 to 2008, even as the total solar irradiance measured simultaneously by SORCE's Total Irradiance Monitor (TIM) decreased. As well, solar ultraviolet (UV) irradiance decreased 3 to 10 times more than expected from prior observations and model calculations of the known effects of sunspot and facular solar features. Analysis of the SIM spectral irradiance observations during the solar minimum epoch of 2008, when solar activity was essentially invariant, exposes trends in the SIM observations relative to both total solar irradiance and solar activity that are unlikely solar in origin. We suggest that the SIM's radically different solar variability characterization is a consequence of undetected instrument sensitivity drifts, not true solar spectrum changes. It is thus doubtful that simulations of climate and atmospheric change using SIM measurements are indicative of real behavior in the Earth's climate and atmosphere.

Lean, Judith L.↗

RADIO EMISSION FROM SN 1994I IN NGC 5194 (M 51): THE BEST-STUDIED TYPE Ib/c RADIO SUPERNOVA

We present the results of detailed monitoring of the radio emission from the Type Ic supernova SN 1994I from three days after optical discovery on 1994 March 31 until eight years later at age 2927 days on 2002 April 5. The data were mainly obtained using the Very Large Array at the five wavelengths of {lambda}{lambda}1.3, 2.0, 3.6, 6.2, and 21 cm and from the Cambridge 5 km Ryle Telescope at {lambda}2.0 cm. Two additional measurements were obtained at millimeter wavelengths. This data set represents the most complete, multifrequency radio observations ever obtained for a Type Ib/c supernova. The radio emission evolves regularly in both time and frequency and is well described by established supernova emission/absorption models. It is the first radio supernova with sufficient data to show that it is clearly dominated by the effects of synchrotron self-absorption at early times.

79 ASTRONOMY AND ASTROPHYSICS↗

2010 Groundwater Monitoring and Inspection Report Gnome-Coach Site, New Mexico

This report presents the 2010 groundwater monitoring results collected by the U.S. Department of Energy (DOE) Office of Legacy Management (LM) at the Gnome-Coach (Gnome) Site in New Mexico (Figure 1). Groundwater monitoring consisted of collecting hydraulic head data and groundwater samples from the wells on site. Historically, the U.S. Environmental Protection Agency (EPA) had conducted these annual activities under the Long-Term Hydrologic Monitoring Program (LTHMP). LM took over the sampling and data collection activities in 2008 but continues to use the EPA Radiation and Indoor Environments National Laboratory in Las Vegas, Nevada, to analyze the water samples. This report summarizes groundwater monitoring and site investigation activities that were conducted at the site during calendar year 2010.

54 ENVIRONMENTAL SCIENCES↗