Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Comparison of Activity Determination of Radium 226 in FUSRAP Soil using Various Energy Lines - 12299

Gamma spectroscopy is used at the Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site as the primary radioanalytical tool for quantization of activities of the radionuclides of concern in site soil. When selecting energy lines in gamma spectroscopy, a number of factors are considered including assumptions concerning secondary equilibrium, interferences, and the strength of the lines. The case of the Maywood radionuclide of concern radium-226 (Ra-226) is considered in this paper. At the FUSRAP Maywood Superfund Site, one of the daughters produced from radioactive decay of Ra-226, lead-214 (Pb- 214), is used to quantitate Ra-226. Another Ra-226 daughter, bismuth-214 (Bi-214), also may be used to quantitate Ra-226. In this paper, a comparison of Ra-226 to Pb-214 activities and Ra-226 to Bi-214 activities, obtained using gamma spectrometry for a large number of soil samples, was performed. The Pb-214, Bi-214, and Ra-226 activities were quantitated using the 352 kilo electron volt (keV), 609 keV, and 186 keV lines, respectively. The comparisons were made after correcting the Ra-226 activities by a factor of 0.571 and both ignoring and accounting for the contribution of a U-235 interfering line to the Ra-226 line. For the Pb-214 and Bi-214 activities, a mean in-growth factor was employed. The gamma spectrometer was calibrated for efficiency and energy using a mixed gamma standard and an energy range of 59 keV to 1830 keV. The authors expect other sites with Ra-226 contamination in soil may benefit from the discussions and points in this paper. Proper use of correction factors and comparison of the data from three different gamma-emitting radionuclides revealed agreement with expectations and provided confidence that using such correction factors generates quality data. The results indicate that if contamination is low level and due to NORM, the Ra-226 can be measured directly if corrected to subtract the contribution from U-235. If there is any indication that technologically enhanced uranium may be present, the preferred measurement approach for quantitation of Ra-226 activity is detection of one of the Ra-226 daughters, Pb-214 or Bi-214, using a correction factor obtained from an in-growth curve. The results also show that the adjusted Ra-226 results compare very well with both the Pb-214 and Bi-214 results obtained using an in-growth curve correction factor. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Q-factor of (In,Ga)N containing III-nitride microcavity grown by multiple deposition techniques

A 3λ/2 (In,Ga)N/GaN resonant cavity, designed for ∼415 nm operation, is grown by molecular beam epitaxy and is sandwiched between a 39.5-period (In,Al)N/GaN distributed Bragg reflector (DBR), grown on c-plane GaN-on-sapphire pseudo-substrate by metal-organic vapor phase epitaxy and an 8-period SiO{sub 2}/ZrO{sub 2} DBR, deposited by electron beam evaporation. Optical characterization reveals an improvement in the cavity emission spectral purity of approximately one order of magnitude due to resonance effects. The combination of spectrophotometric and micro-reflectivity measurements confirms the strong quality (Q)-factor dependence on the excitation spot size. We derive simple analytical formulas to estimate leak and residual absorption losses and propose a simple approach to model the Q-factor and to give a quantitative estimation of the weight of cavity disorder. The model is in good agreement with both transfer-matrix simulation and the experimental findings. We point out that the realization of high Q-factor (In,Ga)N containing microcavities on GaN pseudo-substrates is likely to be limited by the cavity disorder.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The multi-mode gyrotron

It is possible to provide a situation in the gyrotron when it possesses a dense spectrum of axial eigenmodes having different frequencies but almost similar Q-factors. In this case, the single-frequency operation of the gyrotron is provided due to non-linear competition of the eigenmodes. It is shown that such an approach opens a way to provide in gyrotrons a close-to-continuous frequency tuning.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Measurand: The Problem of Frequency

The conceptual entity that metrologists term the measurand is a model selected to represent the physical entity being measured. In a world of digital measurements, it should be defined first mathematically, and only then put into words. Human linguistic processes lack the precision required when all we do is use labels. In this paper, reactive power and frequency are used as examples. The act of measurement finds the values of the coef-ficients of the model. In other words, it solves an equation. In a digital instrument, information about the quality of the fit between the physical entity being measured and the conceptual model is often available. In essence the instrument can comment on the selection of the model. This comment should be reported as part of the statement of the result of the measurement, along with the declared value and the uncertainty.

frequency↗

Appalachian Basin Play Fairway Analysis Analyses and Results

*This submission updates a 2015 submission for the utilization analysis (https://gdr.openei.org/submissions/623)* The files document the analysis of utilization potential in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. This 2016 submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau 'Places' within the study area. The SLCOHis was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. In addition to calculating SLCOH, this task also identified many industrial sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing and maps of the sites have been plotted as a layer onto different iterations of maps combining the three geologic risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity). In addition, a shapefile of the industrial sites is also included with 7 associated files. Supporting files are also supplied.

15 GEOTHERMAL ENERGY↗

Utilization Analysis in Low-Temperature Geothermal Play Fairway Analysis for the Appalachian Basin (GPFA-AB)

This submission of Utilization Analysis data to the Geothermal Data Repository (GDR) node of the National Geothermal Data System (NGDS) is in support of Phase 1 Low Temperature Geothermal Play Fairway Analysis for the Appalachian Basin. The submission includes data pertinent to the methods and results of an analysis of the Surface Levelized Cost of Heat (SLCOH) for US Census Bureau Places within the study area. This was calculated using a modification of a program called GEOPHIRES, available at http://koenraadbeckers.net/geophires/index.php. The MATLAB modules used in conjunction with GEOPHIRES, the MATLAB data input file, the GEOPHIRES output data file, and an explanation of the software components have been provided. Results of the SLCOH analysis appear on 4 .png image files as mapped risk of heat utilization. For each of the 4 image (.png) files, there is an accompanying georeferenced TIF (.tif) file by the same name. In addition to calculating SLCOH, this Task 4 also identified many sites that may be prospects for use of a geothermal district heating system, based on their size and industry, rather than on the SLCOH. An industry sorted listing of the sites (.xlsx) and a map of these sites plotted as a layer onto different iterations of maps combining the three geological risk factors (Thermal Quality, Natural Reservoir Quality, and Risk of Seismicity) has been provided. In addition to the 6 image (.png) files of the maps in this series, a shape (.shp) file and 7 associated files are included as well. Finally, supporting files (.pdf) describing the utilization analysis methodology and summarizing the anticipated permitting for a deep district heating system are supplied. UPDATE: Newer version of the Utilization Analysis has been added here: https://gdr.openei.org/submissions/878

15 GEOTHERMAL ENERGY↗

SU-E-T-804: Verification of the BJR-25 Method of KQ Determination for CyberKnife Absolute Dosimetry

Purpose: Absolute calibration of the CyberKnife is performed using a 6cm-diameter cone defined at 80cm SAD. Since kQ is defined using PDD values determined using 10×10 cm fields at 100cm SSD, the PDD must be corrected in order to correctly apply the quality conversion factor. The accepted method is based on equivalent field-size conversions of PDD values using BJR25. Using the new InCise MLC system, the CK is capable of generating a rectangular field equivalent to 10×10 cm square field. In this study, a comparison is made between kQ values determined using the traditional BJR25 method and the MLC method introduced herein. Methods: First, kQ(BJR) is determined: a PDD is acquired using a 6cm circular field at 100cm SSD, its field size converted to an equivalent square, and PDD converted to a 10×10cm field using the appropriate BJR25 table. Maintaining a consistent setup, the collimator is changed, and the MLC method is used. Finally, kQ is determined using PDDs acquired with a 9.71×10.31cm at 100cm SSD. This field is produced by setting the field to a size of 7.77×8.25cm (since it is defined at 80cm SAD). An exact 10×10cm field since field size is relegated to increments of its leaf width (0.25cm). This comparison is made using an Exradin A1SL, IBA CC08, IBA CC13, and an Exradin A19. For each detector and collimator type, the beam injector was adjusted to give 5 different beam qualities; representing a range of clinical systems. Results: Averaging across all beam qualities, kQ(MLC) differed from kQ(BJR) by less than 0.15%. The difference between the values increased with detector volume. Conclusion: For CK users with standard cone collimators, the BJR25 method has been verified. For CK users the MLC system, a technique is described to determine kQ. Primary author is the President/Owner of Spectrum Medical Physics, LLC, a company which maintains contracts with Siemens Healthcare and Standard Imaging, Inc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fusion Power measurement at ITER

Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlocal Metasurfaces and Their High Q‐Factors in Fano Resonances

Herein nonlocal metasurfaces of parallel bars stitched to cubic rectangles containing structural and symmetry perturbations with a coupling of localized Mie resonance in meta‐atoms and Bragg modes in photonic crystals are reported. Two Fano resonances have been identified that maintain ultrahigh Q‐factors at incident angles of light up to 5°. Increasing the symmetry of the meta‐atoms results in Fano resonances with Q‐factors increased by a factor of 26, compared with the metasurfaces with a single bar stitched to a cubic rectangle at the incident angle of 5°. Due to nonlocal coupling of Bragg scattering and Mie resonance, the Q‐factor maintains almost a constant at 5° of incidence, while it varies with structural or symmetrical perturbations at 0°.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tunable, Homoepitaxial Hyperbolic Metamaterials Enabled by High Mobility CdO

We report propagating light exhibits hyperbolicity in strongly anisotropic materials where the principal components of the dielectric tensor are opposite in sign. While hyperbolicity occurs naturally in anisotropic polar dielectrics, wherein optical phonons along orthogonal crystal axes are nondegenerate, such optical anisotropy can also be engineered in hyperbolic metamaterials (HMMs): thin film superlattices of alternating dielectric and metallic layers. Contrasted with the severely limited tunability of natural hyperbolic materials, the hyperbolic behavior of HMMs can be tailored significantly both through superlattice design and material selection. However, so far HMMs have suffered from high optical losses, hindering their performance. In this report, broadly tunable (λ = 2–5 µm) Type I and II hyperbolic modes with low losses (quality (Q)-factors up to 19.7) are observed through attenuated total reflectance measurements of monolithic, homoepitaxial superlattices of high- and low-doped cadmium oxide (CdO). Further, the low losses offered by CdO enable the first demonstration of real-space imaging of hyperbolic plasmon polaritons in nanoresonators by scattering-type scanning near-field optical microscopy—previously only possible for hyperbolic phonon polariton materials. Tunable, low-loss CdO HMMs promise designability for applications such as on-chip photonics, super-resolution imaging (hyperlensing), enhanced emission, novel emitter designs, and possibly quantum nanophotonic and time variant metasurfaces.

36 MATERIALS SCIENCE↗

Hybrid Plasmonic Coupled‐Mode Metasurface Design for Shot‐Noise Limited Ppb‐Level Hydrogen Detection

Plasmonic hydrogen sensors have enabled hydrogen detection below parts-per-million (ppm) range by boosting the sensitivity using localized surface plasmonic resonant (LSPR) structures. However, the intrinsic optical losses of Palladium (Pd), the primary plasmonic metal used for hydrogen detection, result in a low quality (Q) factor LSPR, which fundamentally hinders further improvement. In this work, a hybrid plasmonic metasurface is proposed that couples Pd-based LSPR structure with an Au film supporting surface plasmon polariton mode (Au-SPP). The coupled near-perfect absorber resonance yields a spectrally narrow, high Q response that retains strong sensitivity to hydrogen while improving resonance localization. Numerical analysis shows that, under shot-noise-limited conditions, the limit of detection (LoD) can be improved by over threefold compared to the state-of-the-art designs. Furthermore, this hybrid plasmonic coupled-mode metasurface thus presents a promising pathway to achieve parts-per-billion-level (ppb-level) hydrogen detection with enhanced spectral precision and robustness.

coupled modes↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Characterization of the mud displacement in an enlarged wellbore: An integrated rock-fluid model

Cement-mud displacement plays a crucial role in the sealability of cement sheaths. Irregular geometric features of a wellbore due to washout can have a negative impact on mud and cement mobilization. An unstable interface between two fluids always leads to mud channeling, interfluid mixing, and cement contamination, degrading the cement quality. Many factors, such as mechanical and rheological properties of fluids, annulus geometry, flow pattern, and flow rate, significantly influence the displacement efficiency. This study investigates the characterization of the mud displacement in an irregular horizontal well using a 3D computational fluid dynamics (CFD) model. Mud is displaced in an enlarged wellbore by geopolymer and neat class G cement. The wellbore geometry is developed based on the caliper log data from an unconventional shale well in the Tuscaloosa Marine Shale (TMS) lithology. The effects of pump rate, density difference, and mud contamination are evaluated by numerical simulations. The results present those residual muds mainly exist in the upper annulus of the enlarged section. Geopolymer has a better sealing performance and can resist more water-based mud (WBM) contaminations than neat class G cement. The scenario with a low mud-cement density difference and high cement injection rate results in a high cement volume fraction, mitigating the gas migration.

58 GEOSCIENCES↗

Fluid bed gasification – Plasma converter process generating energy from solid waste: Experimental assessment of sulphur species

Highlights: • We investigate gaseous sulphur species whilst gasifying sulphur-enriched wood pellets. • Experiments performed using a two stage fluid bed gasifier – plasma converter process. • Notable SO{sub 2} and relatively low COS levels were identified. • Oxygen-rich regions of the bed are believed to facilitate SO{sub 2}, with a delayed release. • Gas phase reducing regions above the bed would facilitate more prompt COS generation. - Abstract: Often perceived as a Cinderella material, there is growing appreciation for solid waste as a renewable content thermal process feed. Nonetheless, research on solid waste gasification and sulphur mechanisms in particular is lacking. This paper presents results from two related experiments on a novel two stage gasification process, at demonstration scale, using a sulphur-enriched wood pellet feed. Notable SO{sub 2} and relatively low COS levels (before gas cleaning) were interesting features of the trials, and not normally expected under reducing gasification conditions. Analysis suggests that localised oxygen rich regions within the fluid bed played a role in SO{sub 2}’s generation. The response of COS to sulphur in the feed was quite prompt, whereas SO{sub 2} was more delayed. It is proposed that the bed material sequestered sulphur from the feed, later aiding SO{sub 2} generation. The more reducing gas phase regions above the bed would have facilitated COS – hence its faster response. These results provide a useful insight, with further analysis on a suite of performed experiments underway, along with thermodynamic modelling.

09 BIOMASS FUELS↗

Lignite quality uncertainty estimation for the assessment of CO{sub 2} emissions

In this study, models were developed for the estimation of CO{sub 2} emissions from lignite- fired power plants based on routinely measured quality parameters of lignite and the power-plant efficiency. These models could be incorporated into the production scheduling optimization plan of the lignite mining. A probabilistic methodology for uncertainty assessment of CO{sub 2} emissions and assigning this uncertainty to different sources (lignite quality, activity, and operational data of power plants) was performed. A Monte Carlo uncertainty and sensitivity analyses method was found appropriate because of the strong correlations between input quality parameters. This method was applied to the largest power plant in Greece for the estimation of the uncertainties in annual, monthly, and daily CO{sub 2} emissions. Sensitivity analysis revealed that the variance of CO{sub 2} emissions was mainly determined by the uncertainty of the quality parameters of lignite, with carbon content being the most dominant parameter. 16 refs., 6 figs., 4 tabs.

01 COAL, LIGNITE, AND PEAT↗

High-quality microresonators in the longwave infrared based on native germanium

The longwave infrared (LWIR) region of the spectrum spans 8 to 14 μm and enables high-performance sensing and imaging for detection, ranging, and monitoring. Chip-scale LWIR photonics has enormous potential for real-time environmental monitoring, explosive detection, and biomedicine. However, realizing technologies such as precision sensors and broadband frequency combs requires ultra low-loss and low-dispersion components, which have so far remained elusive in this regime. Here, we use native germanium to demonstrate the first high-quality microresonators in the LWIR. These microresonators are coupled to partially-suspended Ge waveguides on a separate glass chip, allowing for the first unambiguous measurements of isolated linewidths. At 8 μm, we measured losses of 0.5 dB/cm and intrinsic quality (Q) factors of 2.5 × 10 5 , nearly two orders of magnitude higher than prior LWIR resonators. Our work portends the development of novel sensing and nonlinear photonics in the LWIR regime.

47 OTHER INSTRUMENTATION↗

Nanophotonic Filters and Integrated Networks in Flexible 2D Polymer Photonic Crystals

Polymers have appealing optical, biochemical, and mechanical qualities, including broadband transparency, ease of functionalization, and biocompatibility. However, their low refractive indices have precluded wavelength-scale optical confinement and nanophotonic applications in polymers. Here, we introduce a suspended polymer photonic crystal (SPPC) architecture that enables the implementation of nanophotonic structures typically limited to high-index materials. Using the SPPC platform, we demonstrate nanophotonic band-edge filters, waveguides, and nanocavities featuring quality (Q) factors exceeding 2, 300 and mode volumes (V-mode) below 1.7(l/n) 3 . The unprecedentedly high Q/V-mode ratio results in a spectrally selective enhancement of radiative transitions of embedded emitters via the cavity Purcell effect with an enhancement factor exceeding 100. Moreover, the SPPC architecture allows straightforward integration of nanophotonic networks, shown here by a waveguide-coupled cavity drop filter with sub-nanometer spectral resolution. The nanoscale optical confinement in polymer promises new applications ranging from optical communications to organic opto-electronics, and nanophotonic polymer sensors.

PHOTONIC CRYSTALS↗