Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Infrared photometry and polarimetry of Cygnus X-3

We present photometry and linear polarimetry of Cygnus X-3 at K (2.2 micrometers) obtained over a 5 yr period. Photometry and polarimetry at J, H, and K of nearby field stars is also presented. From an analysis of these data we find: (1) Using the x-ray ephemeris of Kitamoto et al. (ApJ, 384, 263 (1992), including the first and second derivatives of the period, the leading edge of the decline to minimum in the quiescent K light curve has not changed in phase since 1974. The duration of the minimum in the light curve has changed significantly between different epochs, becoming much broader in 1993 than it was previously. (2) In addition to an interstellar polarization component, it is likely Cyg X-3 has an intrinsic polarization component that is variable. The variations in the polarization do not show any diagnostic pattern with orbital phase. A crude analysis of the polarization suggests the intrinsic polarization of Cyg X-3 has a mean position angle of approximately 12 deg, nearly the same as the direction of the expanding radio lobes. This is consistent with circumstellar electrons scattering in an equatorial disk that is perpendicular to the lobe axis. (3) The mean position angle for the interstellar polarization in the direction of Cyg X-3 is 150 deg. This is nearly perpendicular to the axis of interstellar radio scattering seen in the extended (Very Long Baseline Inteferometry (VLBI) images. Since the position angle of interstellar polarization is the same as the projected magnetic field direction, this suggests the interstellar (not circumstellar) scattering must be taking place perpendicular to the interstellar magnetic field lines. (4) Cyg X-3 was observed at K during a flare on 1992 September 30 with a temporal resolution of 6 s. The flaring had rise and fall times of approximately 50 s with peak intensities up to 80 mJy. The flux between individual flare events never dropped to quiescent levels for the duration of our observations (approximately 2000 s).

Jones, Terry Jay↗

Noncollinear spin structure in F e 3 + x C o 3 – x T i 2 ( x = 0 , 2 , 3 ) from neutron diffraction

Neutron powder diffraction has been used to investigate the spin structure of the hard-magnetic alloy Fe 3+x Co 3–x Ti 2 (x = 0,2,3). The materials are produced by rapid quenching from the melt, they possess a hexagonal crystal structure, and they are nanocrystalline with crystallite sizes D of the order of 40 nm. Projections of the magnetic moment onto both the crystalline c axis and the basal plane were observed. The corresponding misalignment angle exhibits a nonlinear decrease with x, which we explain as a micromagnetic effect caused by Fe-Co site disorder. As a result, the underlying physics is a special kind of random-anisotropy magnetism that leads to the prediction of 1/ D 1/4 power-law dependence of the misalignment angle on the crystallite size.

36 MATERIALS SCIENCE↗

RF design for the TOPGUN photogun: A cryogenic normal conducting copper electron gun

Some recent studies of rf breakdown physics in cryogenic copper X-band accelerating structures have shown a dramatic increase in the operating gradient while maintaining low breakdown rates. The TOPGUN project, a collaboration between UCLA, SLAC, and INFN, will use this improvement in gradient to create an ultra-high brightness cryogenic normal conducting photoinjector [16]. The brightness is expected to be higher by a factor of 25 relative to the LCLS photogun [9]. This improvement in the brightness will lead to increased performance of X-Ray free electron lasers (FELs) and ultrafast electron diffraction devices [16]. Here, we present the rf design for this S-band photogun, which will be a drop-in replacement for the current LCLS photogun.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Soft X-ray spectrometer design for warm dense plasma measurements on DARHT Axis-I

A preliminary design study is being performed on a soft X-ray spectrometer to measure K-shell spectra emitted by a warm dense plasma generated on Axis-I of the Dual-Axis Radiographic Hydrodynamic Testing (DARHT) facility at Los Alamos National Laboratory. The 100-ns-long intense, relativistic electron pulse with a beam current of 1.7 kA and energy of 19.8 MeV deposits energy into a thin metal foil heating it to a warm dense plasma. The collisional ionization of the target by the electron beam produces an anisotropic angular distribution of K-shell radiation and a continuum of both scattered electrons and Bremsstrahlung up to the beam energy of 19.8 MeV. The principal goal of this project is to characterize these angular distributions to determine the optimal location to deploy the soft X-ray spectrometer. In addition, a proof-of-principle design will be presented. The ultimate goal of the spectrometer is to obtain measurements of the plasma temperature and density to benchmark equation-of-state models of the warm dense matter regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GALAXY AND MASS ASSEMBLY (GAMA): WITNESSING THE ASSEMBLY OF THE CLUSTER ABELL 1882

We present a combined optical and X-ray analysis of the rich cluster ABELL 1882 (A1882) with the aim of identifying merging substructure and understanding the recent assembly history of this system. Our optical data consist of spectra drawn from the Galaxy and Mass Assembly survey, which lends itself to this kind of detailed study thanks to its depth and high spectroscopic completeness. We use 283 spectroscopically confirmed cluster members to detect and characterize substructure. We complement the optical data with X-ray data taken with both Chandra and XMM. Our analysis reveals that A1882 harbors two main components, A1882A and A1882B, which have a projected separation of {approx}2 Mpc and a line of sight velocity difference of v{sub los}{approx}-428{sup +187}{sub -139} km s{sup -1}. The primary system, A1882A, has velocity dispersion {sigma}{sub v}=500{sub -26}{sup +23} km s{sup -1} and Chandra (XMM) temperature kT = 3.57 {+-} 0.17 keV (3.31{sup +0.28}{sub -0.27} keV) while the secondary, A1882B, has {sigma}{sub v}=457{sup +108}{sub -101} km s{sup -1} and Chandra (XMM) temperature kT = 2.39 {+-} 0.28 keV (2.12 {+-} 0.20 keV). The optical and X-ray estimates for the masses of the two systems are consistent within the uncertainties and indicate that there is twice as much mass in A1882A (M{sub 500} = 1.5-1.9 Multiplication-Sign 10{sup 14} M{sub Sun }) when compared with A1882B (M{sub 500} = 0.8-1.0 Multiplication-Sign 10{sup 14} M{sub Sun }). We interpret the A1882A/A1882B system as being observed prior to a core passage. Supporting this interpretation is the large projected separation of A1882A and A1882B and the dearth of evidence for a recent (<2 Gyr) major interaction in the X-ray data. Two-body analyses indicate that A1882A and A1882B form a bound system with bound incoming solutions strongly favored. We compute blue fractions of f{sub b} = 0.28 {+-} 0.09 and 0.18 {+-} 0.07 for the spectroscopically confirmed member galaxies within r{sub 500} of the centers of A1882A and A1882B, respectively. These blue fractions do not differ significantly from the blue fraction measured from an ensemble of 20 clusters with similar mass and redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-183: Interior Region-Of-Interest Tomography by Using Inverse Geometry System

Purpose: The inverse geometry computed tomography (IGCT) composed of multiple source and small size detector has several merits such as reduction of scatter effect and large volumetric imaging within one rotation without cone-beam artifact, compared to conventional cone-beam computed tomography (CBCT). By using this multi-source characteristics, we intend to present a selective and multiple interior region-of-interest (ROI) imaging method by using a designed source on-off sequence of IGCT. Methods: All of the IGCT sources are operated one by one sequentially, and each projection in the shape of narrow cone-beam covers its own partial volume of full field of view (FOV) determined from system geometry. Thus, through controlling multi source operation, limited irradiation within ROI is possible and selective radon space data for ROI imaging can be acquired without additional X-ray filtration. With this feature, we designed a source on-off sequence for multi ROI-IGCT imaging, and projections of ROI-IGCT were generated by using the on-off sequence. Multi ROI-IGCT images were reconstructed by using filtered back-projection algorithm. All these imaging process of our study has been performed by utilizing digital phantom and patient CT data. ROI-IGCT images of the phantom were compared to CBCT image and the phantom data for the image quality evaluation. Results: Image quality of ROI-IGCT was comparable to that of CBCT. However, the distal axial-plane from the FOV center, large cone-angle region, ROI-IGCT showed uniform image quality without significant cone-beam artifact contrary to CBCT. Conclusion: ROI-IGCT showed comparable image quality and has the capability to provide multi ROI image within a rotation. Projection of ROI-IGCT is performed by selective irradiation, hence unnecessary imaging dose to non-interest region can be reduced. In this regard, it seems to be useful for diagnostic or image guidance purpose in radiotherapy such as low dose target localization and patient alignment. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

60 APPLIED LIFE SCIENCES↗

SU-E-J-56: Static Gantry Digital Tomosynthesis From the Beam’s-Eye-View

Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L. Partain, J. Kwon, D. Boyd: NIH/SBIR R43CA192489-01. J. Rottmann, G. Zentai, R. Berbeco: NIH/NCI 1R01CA188446-01. R. Berbeco: E. Research Grant, Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Inputs from regularly and irregularly discharging vestibular nerve afferents to secondary neurons in squirrel monkey vestibular nuclei. III. Correlation with vestibulospinal and vestibuloocular output pathways

1. A previous study measured the relative contributions made by regularly and irregularly discharging afferents to the monosynaptic vestibular nerve (Vi) input of individual secondary neurons located in and around the superior vestibular nucleus of barbiturate-anesthetized squirrel monkeys. Here, the analysis is extended to more caudal regions of the vestibular nuclei, which are a major source of both vestibuloocular and vestibulospinal pathways. As in the previous study, antidromic stimulation techniques are used to classify secondary neurons as oculomotor or spinal projecting. In addition, spinal-projecting neurons are distinguished by their descending pathways, their termination levels in the spinal cord, and their collateral projections to the IIIrd nucleus. 2. Monosynaptic excitatory postsynaptic potentials (EPSPs) were recorded intracellularly from secondary neurons as shocks of increasing strength were applied to Vi. Shocks were normalized in terms of the threshold (T) required to evoke field potentials in the vestibular nuclei. As shown previously, the relative contribution of irregular afferents to the total monosynaptic Vi input of each secondary neuron can be expressed as a %I index, the ratio (x100) of the relative sizes of the EPSPs evoked by shocks of 4 x T and 16 x T. 3. Antidromic stimulation was used to type secondary neurons as 1) medial vestibulospinal tract (MVST) cells projecting to spinal segments C1 or C6; 2) lateral vestibulospinal tract (LVST) cells projecting to C1, C6; or L1; 3) vestibulooculo-collic (VOC) cells projecting both to the IIIrd nucleus and by way of the MVST to C1 or C6; and 4) vestibuloocular (VOR) neurons projecting to the IIIrd nucleus but not to the spinal cord. Most of the neurons were located in the lateral vestibular nucleus (LV), including its dorsal (dLV) and ventral (vLV) divisions, and adjacent parts of the medial (MV) and descending nuclei (DV). Cells receiving quite different proportions of their direct inputs from regular and irregular afferents were intermingled in all regions explored. 4. LVST neurons are restricted to LV and DV and show a somatotopic organization. Those destined for the cervical and thoracic cord come from vLV, from a transition zone between vLV and DV, and to a lesser extent from dLV. Lumbar-projecting neurons are located more dorsally in dLV and more caudally in DV. MVST neurons reside in MV and in the vLV-DV transition zone.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

FK COMAE BERENICES, KING OF SPIN: THE COCOA-PUFS PROJECT

COCOA-PUFS is an energy-diverse, time-domain study of the ultra-fast spinning, heavily spotted, yellow giant FK Comae Berenices (FK Com: HD117555; G4 III). This single star is thought to be a recent binary merger, and is exceptionally active by measure of its intense ultraviolet (UV) and X-ray emissions, and proclivity to flare. COCOA-PUFS was carried out with the Hubble Space Telescope in the UV (1200–3000 Å), using mainly its high-performance Cosmic Origins Spectrograph, but also high precision Space Telescope Imaging Spectrograph; Chandra X-ray Observatory in the soft X-rays (0.5–10 keV), utilizing its High-Energy Transmission Grating Spectrometer; together with supporting photometry and spectropolarimetry in the visible from the ground. This is an introductory report on the project. FK Com displayed variability on a wide range of timescales over all wavelengths during the week-long main campaign, including a large X-ray flare; “super-rotational broadening” of the far-ultraviolet “hot lines” (e.g., Si iv 1393 Å; 8 × 10{sup 4} K) together with chromospheric Mg ii 2800 Å and C ii 1335 Å (1–3 × 10{sup 4} K); large Doppler swings suggestive of bright regions alternately on advancing and retreating limbs of the star; and substantial redshifts of the epoch-average emission profiles. These behaviors paint a picture of a highly extended, dynamic, hot (∼10 MK) coronal magnetosphere around the star, threaded by cooler structures perhaps analogous to solar prominences and replenished continually by surface activity and flares. Suppression of angular momentum loss by the confining magnetosphere could temporarily postpone the inevitable stellar spindown, thereby lengthening this highly volatile stage of coronal evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Phase equilibria in the quasiternary system Ag{sub 2}S–Ga{sub 2}S{sub 3}–In{sub 2}S{sub 3} and optical properties of (Ga{sub 55}In{sub 45}){sub 2}S{sub 300}, (Ga{sub 54.59}In{sub 44.66}Er{sub 0.75}){sub 2}S{sub 300} single crystals

The quasiternary system Ag{sub 2}S–Ga{sub 2}S{sub 3}–In{sub 2}S{sub 3} was investigated by differential thermal, X-ray diffraction analyses. The phase diagram of the Ga{sub 2}S{sub 3}–In{sub 2}S{sub 3} system and nine polythermal sections, isothermal section at 820 K and the liquidus surface projection were constructed. The existence of the large solid solutions ranges of binary and ternary compounds was established. The range of the existence of the quaternary phase AgGa{sub x}In{sub 5−x}S{sub 8} (2.25≤x≤2.85) at 820 K was determined. The single crystals (Ga{sub 55}In{sub 45}){sub 2}S{sub 300} and (Ga{sub 54.59}In{sub 44.66}Er{sub 0.75}){sub 2}S{sub 300} were grown by a directional crystallization method from solution-melt. Optical absorption spectra in the 500–1600 nm range were recorded. The luminescence of the (Ga{sub 54.59}In{sub 44.66}Er{sub 0.75}){sub 2}S{sub 300} single crystal shows a maximum at 1530 nm for the excitation wavelengths of 532 and 980 nm at 80 and 300 K. - Graphical abstract: Isothermal section of the quasiternary system Ag{sub 2}S–Ga{sub 2}S{sub 3}–In{sub 2}S{sub 3} at 820 K and normalized photoluminescence spectra of the single crystal (Ga{sub 54.59}In{sub 44.66}Er{sub 0.75}){sub 2}S{sub 300} at 300 K. - Highlights: • Isothermal section at 820 K, liquidus surface projection were built for Ag{sub 2}S–Ga{sub 2}S{sub 3}–In{sub 2}S{sub 3}. • Optical properties of single crystals were studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Re-engineering Nascom's network management architecture

The development of Nascom systems for ground communications began in 1958 with Project Vanguard. The low-speed systems (rates less than 9.6 Kbs) were developed following existing standards; but, there were no comparable standards for high-speed systems. As a result, these systems were developed using custom protocols and custom hardware. Technology has made enormous strides since the ground support systems were implemented. Standards for computer equipment, software, and high-speed communications exist and the performance of current workstations exceeds that of the mainframes used in the development of the ground systems. Nascom is in the process of upgrading its ground support systems and providing additional services. The Message Switching System (MSS), Communications Address Processor (CAP), and Multiplexer/Demultiplexer (MDM) Automated Control System (MACS) are all examples of Nascom systems developed using standards such as, X-windows, Motif, and Simple Network Management Protocol (SNMP). Also, the Earth Observing System (EOS) Communications (Ecom) project is stressing standards as an integral part of its network. The move towards standards has produced a reduction in development, maintenance, and interoperability costs, while providing operational quality improvement. The Facility and Resource Manager (FARM) project has been established to integrate the Nascom networks and systems into a common network management architecture. The maximization of standards and implementation of computer automation in the architecture will lead to continued cost reductions and increased operational efficiency. The first step has been to derive overall Nascom requirements and identify the functionality common to all the current management systems. The identification of these common functions will enable the reuse of processes in the management architecture and promote increased use of automation throughout the Nascom network. The MSS, CAP, MACS, and Ecom projects have indicated the potential value of commercial-off-the-shelf (COTS) and standards through reduced cost and high quality. The FARM will allow the application of the lessons learned from these projects to all future Nascom systems.

Drake, Brian C.↗

Three-Dimensional Morphological Analysis of ALH84001 Magnetite Using Electron Tomography

We report here the crystal morphologies of MV-1 and ALH84001 magnetites as calculated by back-projection using electron tomography. In the present study, we used a 300 keV TEM with a field emission gun (Tecnai F-30 from FEI Inc.), equipped with a 2048 x 2048 pixel CCD camera from Gatan Inc. to image magnetite crystals over tilt ranges of approx. +/- 72 deg in 2 deg tilt intervals. The images were aligned for back-projection, either manually, or through the use of fiducial 5 nm Au spheres affixed to the specimen prior to microscopy. Three-dimensional (3-D) reconstructions were computed using weighted back-projection of the tilted views. The tomograms were viewed and analyzed as a series of slices 1.0 nm thick, taken parallel to the specimen-supporting grid, using the IMOD software package. The shape of each magnetite crystal was determined by defining the external contour of a given magnetite in each slice and assembling a stack of these contours in 3-D. To aid in visualization, the stacked contour array was reduced to an optimal mesh by Delaunay triangulation. The surface normal to each of the triangles in the mesh was calculated and the triangle faces colored according to the orientation of that surface normal relative to the principal crystallographic axis of magnetite. Green surfaces correspond to {111} orientations, blue surfaces to {100} orientations, and red surfaces to {110} orientations. Triangles whose surface normal did not correspond to one of the principal axes were colored gray. Within the experimental and numerical uncertainties of the deconvolution, the tomographic reconstruction of both MV-1 and ALH84001 magnetites are equivalent and correspond to a truncated hexa-octahedral morphology.

Thomas-Keprta, Kathie L.↗

X-ray Mapping of Nanoparticle Superlattice Thin Films

We combine grazing-incidence and transmission small-angle X-ray diffraction with electron microscopy studies to characterize the structure of nanoparticle films with long-range order. Transmission diffraction is used to collect in-plane diffraction data from single grains and locally aligned nanoparticle superlattice films. Systematic mapping of samples can be achieved by translating the sample in front of the X-ray beam with a spot size selected to be on the order of superlattice grain features. This allows a statistical determination of superlattice grain size and size distribution over much larger areas than typically accessible with electron microscopy. Transmission X-ray measurements enables spatial mapping of the grain size, orientation, uniformity, strain, or crystal projections and polymorphs. Furthermore, we expand this methodology to binary nanoparticle superlattice and nanorod superlattice films. Our study provides a framework for characterization of nanoparticle superlattices over large areas which complements or expands microstructure information from real-space imaging.

GISAXS↗

Witnessing the growth of the nearest galaxy cluster: thermodynamics of the Virgo Cluster outskirts

Here, we present results from Suzaku Key Project observations of the Virgo Cluster, the nearest galaxy cluster to us, mapping its X-ray properties along four long ‘arms’ extending beyond the virial radius. The entropy profiles along all four azimuths increase with radius, then level out beyond ~0.5r 200 , while the average pressure at large radii exceeds Planck Sunyaev–Zel'dovich measurements. These results can be explained by enhanced gas density fluctuations (clumping) in the cluster's outskirts. Using a standard Navarro, Frenk and White model, we estimate a virial mass, radius and concentration parameter of M 200 = 1.05 ± 0.02 × 10 14 M⊙, r 200 = 974.1 ± 5.7 kpc and c = 8.8 ± 0.2, respectively. The inferred cumulative baryon fraction exceeds the cosmic mean at r ~r 200 along the major axis, suggesting enhanced gas clumping possibly sourced by a candidate large-scale structure filament along the north–south direction. The Suzaku data reveal a large-scale sloshing pattern, with two new cold fronts detected at radii of 233 and 280 kpc along the western and southern arms, respectively. Two high-temperature regions are also identified 1 Mpc towards the south and 605 kpc towards the west of M87, likely representing shocks associated with the ongoing cluster growth. Although systematic uncertainties in measuring the metallicity for low-temperature plasma remain, the data at large radii appear consistent with a uniform metal distribution on scales of ~90 × 180 kpc and larger, providing additional support for the early chemical enrichment scenario driven by galactic winds at redshifts of 2–3.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-172: Evaluation of the Exradin A26 Ion Chamber in Megavoltage Photon Beams as a Reference Class Instrument

Purpose: The Exradin A26 is a new design of micro-ionization ion chamber that externally resembles the Exradin A16 model but has significant internal changes to address measurement issues reported in the literature for the A16. This project involved the characterization of two versions of the A26 chamber in high energy x-rays with particular reference to the performance specification laid out in the imminent Addendum to TG-51. Methods: The Exradin A26 was investigated in a range of megavoltage photon beams (6–25 MV). Investigations looked at chamber settling, ion recombination and polarity. Since it has been previously shown that non-ideal performance is most easily identified through ion recombination measurements, the focus was on the determination of Pion. Results: i) Chamber settling - the chamber response stabilizes very quickly (within 3 minutes), even after a large change in the polarizing voltage.ii) The polarity correction was found to be small (within 0.2% of unity)iii) The chamber showed linear behavior for a Jaffe plot (1/reading vs 1/polarizing voltage) for applied voltages ≤ 200 V.iv) The recombination correction showed a linear variation with the doseper- pulse, was not significantly dependent on the polarity of the collecting voltage and was consistent with the chamber dimensions (i.e. agreed with Boag theory). Conclusion: An initial investigation of the Exradin A26 micro chamber suggests that although its performance exceeds the AAPM specification for a reference-class ion chamber for use in megavoltage photon beams it is a significant improvement over the previous A16 design. Further work is required to evaluate long-term stability and determine kQ factors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-351: Verification of Monitor Unit Calculation for Lung Stereotactic Body Radiation Therapy Using a Secondary Independent Planning System

Purpose: To compare isocenter (IC) dose between X-ray Voxel Monte Carlo (XVMC) and Acuros XB (AXB) as part of an independent verification of monitor unit (MU) calculation for lung stereotactic body radiation therapy (SBRT) using a secondary independent treatment planning system (TPS). Methods: Treatment plans of 110 lesions from 101 patients who underwent lung SBRT with Vero4DRT (Mitsubishi Heavy Industries, Ltd., Japan, and BrainLAB, Feldkirchen, Germany) were evaluated retrospectively. Dose distribution was calculated with X-ray Voxel Monte Carlo (XVMC) in iPlan 4.5.1 (BrainLAB, Feldkirchen, Germany) on averaged intensity projection images. A spatial resolution and mean variance were 2 mm and 2%, respectively. The clinical treatment plans were transferred from iPlan to Eclipse (Varian Medical Systems, Palo Alto, CA, USA), and doses were recalculated with well commissioned AXB ver. 11.0.31 while maintaining the XVMC-calculated MUs and beam arrangement. Dose calculations were made in the dose-to-medium dose reporting mode with the calculation grid size of 2.5 mm. The mean and standard deviation (SD) of the IC dose difference between XVMC and AXB were calculated. The tolerance level was defined as |mean|+2SD. Additionally, the relationship between IC dose difference and the size of planning target volume (PTV) or computed tomography (CT) value of internal target volume (ITV) was evaluated. Results: The mean±SD of the IC dose difference between XVMC and AXB was −0.32±0.73%. The tolerance level was 1.8%. Absolute IC dose differences exceeding the tolerance level were observed in 3 patients (2.8%). There were no strong correlations between IC dose difference and PTV size (R=−0.14) or CT value of ITV (R=−0.33). Conclusion: The present study suggested that independent verification of MU calculation for lung SBRT using a secondary TPS is useful.

60 APPLIED LIFE SCIENCES↗

TU-A-12A-08: Computing Longitudinal Material Changes in Bone Metastases Using Dual Energy Computed Tomography

Purpose: This study demonstrates a methodology for tracking changes in metastatic bone disease using trajectories in material basis space in serial dual energy computed tomography (DECT) studies. Methods: This study includes patients with bone metastases from breast cancer that had clinical surveillance CT scans using a General Electric CT750HD in dual energy mode. A radiologist defined regions-of-interested (ROI) for bone metastasis, normal bone, and marrow across the serial DECT scans. Our approach employs a Radon transform to forward-projection the basis images, namely, water and iodine, into sinogram space. This data is then repartitioned into fat/bone and effective density/Z image pairs using assumed energy spectrums for the x-ray energies. This approach both helps remove negative material densities and avoids adding spectrum-hardening artifacts. These new basis data sets were then reconstructed via filtered back-projection to create new material basis pair images. The trajectories of these pairs were then plotted in the new basis space providing a means to both visualize and quantitatively measure changes in the material properties of the tumors. Results: ROI containing radiologist defined metastatic bone disease showed well-defined trajectories in both fat/bone and effective density/Z space. ROI that contained radiologist defined normal bone and marrow did not exhibit any discernible trajectories and were stable from scan to scan. Conclusions: The preliminary results show that changes in material composition and effective density/Z image pairs were seen primarily in metastasis and not in normal tissue. This study indicates that by using routine clinical DECT it may be possible to monitor therapy response of bone metastases because healing or worsening bone metastases change material composition of bone. Additional studies are needed to further validate these results and to test for their correlation with outcome.

60 APPLIED LIFE SCIENCES↗

X-ray computed tomography using partially coherent Fresnel diffraction with application to an optical fiber

A reconstruction algorithm for partially coherent x-ray computed tomography (XCT) including Fresnel diffraction is developed and applied to an optical fiber. The algorithm is applicable to a high-resolution tube-based laboratory-scale x-ray tomography instrument. The computing time is only a few times longer than the projective counterpart. The algorithm is used to reconstruct, with projections and diffraction, a tilt series acquired at the micrometer scale of a graded-index optical fiber using maximum likelihood and a Bayesian method based on the work of Bouman and Sauer. The inclusion of Fresnel diffraction removes some reconstruction artifacts and use of a Bayesian prior probability distribution removes others, resulting in a substantially more accurate reconstruction.

Levine, Zachary H. (ORCID:000000029928276X)↗