Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Efficient hemodynamic event detection utilizing relational databases and wavelet analysis

Development of a temporal query framework for time-oriented medical databases has hitherto been a challenging problem. We describe a novel method for the detection of hemodynamic events in multiparameter trends utilizing wavelet coefficients in a MySQL relational database. Storage of the wavelet coefficients allowed for a compact representation of the trends, and provided robust descriptors for the dynamics of the parameter time series. A data model was developed to allow for simplified queries along several dimensions and time scales. Of particular importance, the data model and wavelet framework allowed for queries to be processed with minimal table-join operations. A web-based search engine was developed to allow for user-defined queries. Typical queries required between 0.01 and 0.02 seconds, with at least two orders of magnitude improvement in speed over conventional queries. This powerful and innovative structure will facilitate research on large-scale time-oriented medical databases.

NASA Discipline Cardiopulmonary↗

Supporting Crew Autonomy in Deep Space Exploration: Preliminary Onboard Capability Requirements and Proposed Research Questions. Technical Report of the Autonomous Crew Operations Technical Interchange Meeting

Communication delays are a critical challenge posed by long duration deep space exploration. Space missions historically have relied on an ever-present Mission Control Center (MCC) to direct operations in near real-time. As unanticipated anomalies that defeat fault detection and resolution systems do arise, the lack of real-time communication will significantly weaken what the MCC support represents: a reliable safety net for the flight crew through its deep and diverse areas of expertise and investigative resources. As a consequence, future space vehicles and habitats need to be equipped with capabilities to support the flight crew to operate with little or no ground support. Considerations must be given to vehicle and mission designs that will fortify the traditionally ground-centered safety net and forge new support systems, when communication delays exist. In August 2018, NASA’s Human Research Program, through its Human Factors and Behavioral Performance Element, convened a Technical Interchange Meeting (TIM) on Autonomous Crew Operations at NASA Ames Research Center. The goal of the meeting was to gather input from NASA centers, industry, academia, and branches of the Department of Defense (DoD) to address how intelligent technologies can be applied to augment onboard capabilities to support crew anomaly response. The TIM featured 24 presentations by 29 speakers and hosted a total of 59 attendees, including 43 from 5 NASA centers (Ames, Johnson, Langley, Marshall, and Jet Propulsion Lab) and 4 from the DoD (3 from Army Research Lab and 1 from Naval Postgraduate School), with remaining attendees from academia (e.g., UC Davis, CMU) and industry (e.g., IBM, Siemens). Discussions were centered around three themes: standards and guidelines, lessons learned in analog environments, and technologies. To help provide a framework for discussion, a concept matrix describing anomaly response processes was created prior to the TIM (Figure 1, page 6). The matrix captures the steps involved (monitoring and detection, diagnosis, solution development and evaluation, solution implementation and verification, resolution documentation) as well as the resources and capabilities required to support these steps (data, knowledge, analysis, synthesis, resource management). A wallpaper size printout of the matrix was utilized at the TIM to solicit attendee inputs along the three themes; the activity garnered 108 submissions of ideas. Overall, what emerged from TIM discussions was a picture of mismatch between crew anomaly response needs and support that can be provided by existing intelligent technologies. The needs are broad, spanning multiple steps and processes/resources, with many of which lacking support from existing technologies, such as knowledge management throughout the steps of problem solving (especially in resolution documentation) and manpower management. The solutions provided by existing intelligent technologies are specific to the steps/processes that they are designed to support and constrained to solving only problems similar to those that have occurred before. What is lacking from technologies is typically made up by humans, specifically their complex critical thinking, creative problem solving, and domain expertise. In the end, the TIM highlighted the pressing need to support responses to onboard anomalies during autonomous crew operations, particularly those that have eluded the system tests, inspection, and other assurance processes. Such anomalies can potentially threaten crew and vehicle safety, as well as significantly impact overall operations with additional workload. These fairly rare events are difficult to anticipate and prepare for, given the state-of-the-art in intelligent technologies. This is true even for anomalies that stem from “unknown knowns”—cases in which there is sufficient external information to characterize the problem but the overall pattern fails to be recognized by the problem solver, or in which the internal knowledge needed to solve a problem is held tacitly and potentially accessible by the problem solver but not articulated. It follows that the ability to tackle anomalies lies not only with the availability of relevant information and knowledge but also their accessibility in times of need. To that end, we propose research questions along the following three broad themes: • How intelligent technologies can help make relevant knowledge and information available? • How intelligent technologies can help make relevant knowledge and information accessible? • How intelligent technologies can help support the crew operating as a team in anomaly response processes?

autonomous crew operations↗

Wireless Integrated Microelectronic Vacuum Sensor System

NASA Stennis Space Center's (SSC's) large rocket engine test facility requires the use of liquid propellants, including the use of cryogenic fluids like liquid hydrogen as fuel, and liquid oxygen as an oxidizer (gases which have been liquefied at very low temperatures). These fluids require special handling, storage, and transfer technology. The biggest problem associated with transferring cryogenic liquids is product loss due to heat transfer. Vacuum jacketed piping is specifically designed to maintain high thermal efficiency so that cryogenic liquids can be transferred with minimal heat transfer. A vacuum jacketed pipe is essentially two pipes in one. There is an inner carrier pipe, in which the cryogenic liquid is actually transferred, and an outer jacket pipe that supports and seals the vacuum insulation, forming the "vacuum jacket." The integrity of the vacuum jacketed transmission lines that transfer the cryogenic fluid from delivery barges to the test stand must be maintained prior to and during engine testing. To monitor the vacuum in these vacuum jacketed transmission lines, vacuum gauge readings are used. At SSC, vacuum gauge measurements are done on a manual rotation basis with two technicians, each using a handheld instrument. Manual collection of vacuum data is labor intensive and uses valuable personnel time. Additionally, there are times when personnel cannot collect the data in a timely fashion (i.e., when a leak is detected, measurements must be taken more often). Additionally, distribution of this data to all interested parties can be cumbersome. To simplify the vacuum-gauge data collection process, automate the data collection, and decrease the labor costs associated with acquiring these measurements, an automated system that monitors the existing gauges was developed by Invocon, Inc. For this project, Invocon developed a Wireless Integrated Microelectronic Vacuum Sensor System (WIMVSS) that provides the ability to gather vacuum-gauge measurements automatically and wirelessly, in near-real time - using a low-maintenance, lowpower sensor mesh network. The WIMVSS operates by using a self-configuring mesh network of wireless sensor units. Mesh networking is a type of networking where each sensor or node can capture and disseminate its own data, but also serve as a relay to receive and transmit data from other sensors. Each sensor node can synchronize with adjacent sensors, and propagate data from one sensor to the next, until the destination is reached. In this case, the destination is a Network Interface Unit (NIU). The WIMVSS sensors are mounted on the existing vacuum gauges. Information gathered by the sensors is sent to the NIU. Because of the mesh networking, if a sensor cannot directly send the data to the NIU, it can be propagated through the network of sensors. The NIU requires antenna access to the sensor units, AC power, and an Ethernet connection. The NIU bridges the sensor network to a WIMVSS server via an Ethernet connection. The server is configured with a database, a Web server, and proprietary interface software that makes it possible for the vacuum measurements from vacuum jacketed fluid lines to be saved, retrieved, and then displayed from any Web-enabled PC that has access to the Internet. Authorized users can then simply access the data from any PC with Internet connection. Commands can also be sent directly from the Web interface for control and maintenance of the sensor network. The technology enabled by the WIMVSS decreases labor required for gathering vacuum measurements, increases access to vacuum data by making it available on any computer with access to the Internet, increases the frequency with which data points can be acquired for evaluating the system, and decreases the recurring cost of the sensors by using off-the-shelf components and integrating these with heritage vacuum gauges.

Krug, Eric↗

A Fast and Sensitive New Satellite SO2 Retrieval Algorithm based on Principal Component Analysis: Application to the Ozone Monitoring Instrument

We describe a new algorithm to retrieve SO2 from satellite-measured hyperspectral radiances. We employ the principal component analysis technique in regions with no significant SO2 to capture radiance variability caused by both physical processes (e.g., Rayleigh and Raman scattering and ozone absorption) and measurement artifacts. We use the resulting principal components and SO2 Jacobians calculated with a radiative transfer model to directly estimate SO2 vertical column density in one step. Application to the Ozone Monitoring Instrument (OMI) radiance spectra in 310.5-340 nm demonstrates that this approach can greatly reduce biases in the operational OMI product and decrease the noise by a factor of 2, providing greater sensitivity to anthropogenic emissions. The new algorithm is fast, eliminates the need for instrument-specific radiance correction schemes, and can be easily adapted to other sensors. These attributes make it a promising technique for producing longterm, consistent SO2 records for air quality and climate research.

Principal component analysis↗

FTIR instrumentation to monitor vapors from Shuttle tile waterproofing materials

The Space Shuttle Thermal Protection System (TPS) tiles and blankets are waterproofed using DimethylEthoxySilane (DMEX) in the Orbiter Processing Facilities (OPF). DMES has a Threshold Limit Value (TLV) for exposure of personnel to vapor concentration in air of 0.5 ppm. The OPF high bay cannot be opened for normal work after a waterproofing operation until the DMES concentration is verified by measurement to be below the TLV. On several occasions the high bay has been kept closed for up to 8 hours following waterproofing operations due to high DMES measurements. In addition, the Miran 203 and Miran 1 BX infrared analyzers calibrated at different wavelengths gave different readings under the same conditions. There was reason to believe that some of the high DMES concentration readings were caused by interference form water and ethanol vapors. The Toxic Vapor Detection Laboratory (TVDL) was asked to test the existing DMES instruments and identify the best qualified instrument. In addition the TVDL was requested to develop instrumentation to ensure the OPF high bay could be opened safely as soon as possible after a waterproofing operation. A Fourier Transform Infrared (FTIR) spectrophotometer instrument developed for an earlier project was reprogrammed to measure DMES vapor along with ethanol, water, and several common solvent vapors. The FTIR was then used to perform a series of laboratory and field tests to evaluate the performance of the single wavelength IR instruments in use. The results demonstrated that the single wavelength IR instruments did respond to ethanol and water vapors, more or less depending on the analytical IR wavelength selected. The FTIR was able to separate the responses to DMES, water and ethanol, and give consistent readings for the DMES vapor concentration. The FTIR was then deployed to the OPF to monitor real waterproofing operations. The FTIR was also used to measure the time for DMES to evaporate from TPS tile under a range of humidity conditions in controlled laboratory tests. The combination of laboratory and field tests with the FTIR instrument demonstrated superior sensitivity, ability to reject interference from water and ethanol vapors, ruggedness to be transported from the lab to the OPF and set up without special procedures or degradation of performance. The multiple component vapor analysis algorithm was developed at KSC and incorporates automatic baseline correction and shape fitting of the spectra. The analysis for DMES, TetraMethylDiSiloxane (TMDS), ethanol, methanol, isopropanol, and baseline parameters uses 161 points per sample at 4 cm(exp -1) resolution, and processes an eight scan sample every ten seconds. The standard deviation of the measurements is 0.013 ppm and the upper linear limit is 125 ppm DMES. Based on successful demonstration of capabilities we produced three mobile instrument carts to be used in each OPF to support future waterproofing operations. The design and building of the 'DMES Carts' were accomplished in Fiscal year 1995.

Mattson, C. B.↗

SCOAPE-II: A 2024 Multiplatform Measurement Campaign off the US Gulf Coast to Assess Oil and Gas Emissions on the Outer Continental Shelf

Nine years ago, the Department of Interior’s Bureau of Ocean Energy Management (BOEM), the Agency with Air Quality (AQ) jurisdiction over the Outer Continental Shelf (OCS) of the US Gulf Coast west of 87.5° W longitude, asked NASA to determine the feasibility of using satellite data to measure offshore emissions in a region of concentrated oil and natural gas (ONG) operations. To study this issue NASA and BOEM conducted the May 2019 Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf. SCOAPE addressed both technological and scientific issues related to measuring nitrogen dioxide (NO 2 , a common air pollutant), including contrasting near-shore and deepwater regimes. Given the April 2023 launch of the geostationary Tropospheric Emissions: Monitoring of Pollution (TEMPO) AQ satellite, a 2024 SCOAPE-II was conducted in the Gulf with both ship and aircraft measurements. We present an overview of the SCOAPE-II campaign, analysis and validation of satellite-observed NO 2 , and evaluate measurements of methane from ship, aircraft, and satellite near ONG platforms. Our SCOAPE-II results are as follows: 1) Satellite NO 2 measurements (∼13:30 local time) from the TROPOspheric Monitoring Instrument (TROPOMI) are more accurate than TEMPO’s hourly scans (8.6% vs. 23.6% mean absolute bias); a new version of TEMPO data is currently being processed; 2) ship and aircraft measurements captured dozens of NO 2 and methane plumes from ONG operations, showing that they are persistent emitters; 3) satellite measurements of methane failed to replicate ship and aircraft measurements, presenting ongoing challenges for operational emissions monitoring over the Gulf.

satellite validation↗

Pulse stretcher for narrow pulses

Pulse stretching circuit can linearly stretch pulses as narrow as 50 nanoseconds and block incoming pulses following accepted input pulse until processing has been completed. It also removes baseline distortion by being completely direct coupled and provides monitor output which measures true number of input events that exceed predetermined threshold.

Lindsey, R. S., Jr.↗

Picture processing of SAR L-band imagery

Data digitization and thresholding are applied to two scenes - sea ice and fresh-water lakes - to define the possible uses of automatic picture processing of uncalibrated SAR L-band imagery. It is shown that certain types of features, those which have constant returns which are also very high or very low in intensity can be effectively studied using simple automatic picture processing techniques applied to uncalibrated radar data. In areas which are generally inaccessible or in which monitoring of the changes of some types of earth surfaces are required, the uncalibrated SAR data can provide valuable inputs for modeling and mapping purposes.

Bryan, M. L.↗

Vestibular influences on other sensory and motor processes

Vestibular effects on perceptual and motor processes are widespread. It is shown that gyrovisual modulation may take three forms: (1) gyrovisual inhibition (monitoring tasks and spurious motion); (2) gyrovisual facilitation (tracking); and (3) gyrovisual conflict (motion sickness and disorientation in flight).

Clark, B.↗

A real-time electronic imaging system for solar X-ray observations from sounding rockets

A real-time imaging system for displaying the solar coronal soft X-ray emission, focussed by a grazing incidence telescope, is described. The design parameters of the system, which is to be used primarily as part of a real-time control system for a sounding rocket experiment, are identified. Their achievement with a system consisting of a microchannel plate, for the conversion of X-rays into visible light, and a slow-scan vidicon, for recording and transmission of the integrated images, is described in detail. The system has a quantum efficiency better than 8 deg above 8 A, a dynamic range of 1000 coupled with a sensitivity to single photoelectrons, and provides a spatial resolution of 15 arc seconds over a field of view of 40 x 40 square arc minutes. The incident radiation is filtered to eliminate wavelengths longer than 100 A. Each image contains 3.93 x 10 to the 5th bits of information and is transmitted to the ground where it is processed by a mini-computer and displayed in real-time on a standard TV monitor.

Davis, J. M.↗

Ultrasonics and Optics Would Control Shot Size

Feedback system assures production of silicon shot of uniform size. Breakup of silicon stream into drops is controlled, in part, by varying frequency of vibrations imparted to stream by ultrasonic transducer. Drop size monitored by photodetector. Control method particularly advantageous in that constant size is maintained even while other process variables are changed deliberately or inadvertently. Applicable to materials other than silicon.

Morrison, A. D.↗

A radar data processing and enhancement system

This report describes the space position data processing system of the NASA Western Aeronautical Test Range. The system is installed at the Dryden Flight Research Facility of NASA Ames Research Center. This operational radar data system (RADATS) provides simultaneous data processing for multiple data inputs and tracking and antenna pointing outputs while performing real-time monitoring, control, and data enhancement functions. Experience in support of the space shuttle and aeronautical flight research missions is described, as well as the automated calibration and configuration functions of the system.

Anderson, K. F.↗

A coated-wire ion-selective electrode for ionic calcium measurements

A coated-wire ion-selective electrode for measuring ionic calcium was developed, in collaboration with Teknektron Sensor Development Corporation (TSDC). This coated wire electrode sensor makes use of advanced, ion-responsive polyvinyl chloride (PVC) membrane technology, whereby the electroactive agent is incorporated into a polymeric film. The technology greatly simplifies conventional ion-selective electrode measurement technology, and is envisioned to be used for real-time measurement of physiological and environment ionic constituents, initially calcium. A primary target biomedical application is the real-time measurement of urinary and blood calcium changes during extended exposure to microgravity, during prolonged hospital or fracture immobilization, and for osteoporosis research. Potential advanced life support applications include monitoring of calcium and other ions, heavy metals, and related parameters in closed-loop water processing and management systems. This technology provides a much simplified ionic calcium measurement capability, suitable for both automated in-vitro, in-vivo, and in-situ measurement applications, which should be of great interest to the medical, scientific, chemical, and space life sciences communities.

Hines, John W.↗

Observations of Ozone-aerosol Correlated Behaviour in the Lower Stratosphere During the EASOE Campaign

The question of possible interactions between ozone and stratospheric aerosol has been open for a long time. Measurements carried out after the Mt. Agung and El Chicon eruptions showed evidence of negative correlations between the presence of volcanic stratospheric aerosols and ozone concentration. Evidence for negative correlations in the polar winter has been also found. It is only after the discovery of the Antarctic ozone hole that catalytic effects related to low temperature heterogeneous chemistry have become the object of much investigation, now extended to the role of volcanic aerosol in the ozone reduction. These phenomena can be the object of various interpretations, not mutually exclusive, including the effect of transport, diffuse radiation as well as heterogeneous chemistry. The present paper provides preliminary results of simultaneous measurements of ozone and aerosol, carried out at Thule, Greenland, during the winter 1991-92. The European Stratospheric Ozone Experiment (EASOE) was aimed at monitoring the winter Arctic stratosphere in order to obtain a deeper insight of the ozone destruction processes taking place in the polar regions. A large amount of aerosol was injected into the lower stratosphere by the recent eruption of Volcano Pinatubo. A lidar system, already operational in Thule since November 1990, has provided detailed measurements of the stratospheric aerosol concentration during EASOE. In the same period, a large number of ozonesondes were launched. Although no PSC formation was detected over Thule, the simultaneous measurement of the stratospheric aerosol and ozone profiles give the possibility to study interactions occurring in the stratosphere between these two constituents.

Digirolamo, P.↗

AVIRIS study of Death Valley evaporite deposits using least-squares band-fitting methods

Minerals found in playa evaporite deposits reflect the chemically diverse origins of ground waters in arid regions. Recently, it was discovered that many playa minerals exhibit diagnostic visible and near-infrared (0.4-2.5 micron) absorption bands that provide a remote sensing basis for observing important compositional details of desert ground water systems. The study of such systems is relevant to understanding solute acquisition, transport, and fractionation processes that are active in the subsurface. Observations of playa evaporites may also be useful for monitoring the hydrologic response of desert basins to changing climatic conditions on regional and global scales. Ongoing work using Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data to map evaporite minerals in the Death Valley salt pan is described. The AVIRIS data point to differences in inflow water chemistry in different parts of the Death Valley playa system and have led to the discovery of at least two new North American mineral occurrences. Seven segments of AVIRIS data were acquired over Death Valley on 31 July 1990, and were calibrated to reflectance by using the spectrum of a uniform area of alluvium near the salt pan. The calibrated data were subsequently analyzed by using least-squares spectral band-fitting methods, first described by Clark and others. In the band-fitting procedure, AVIRIS spectra are fit compared over selected wavelength intervals to a series of library reference spectra. Output images showing the degree of fit, band depth, and fit times the band depth are generated for each reference spectrum. The reference spectra used in the study included laboratory data for 35 pure evaporite spectra extracted from the AVIRIS image cube. Additional details of the band-fitting technique are provided by Clark and others elsewhere in this volume.

Crowley, J. K.↗

Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A): Software concept document

This document presents the concept for two separate but closely related software systems. The first is the special test equipment (STE) software used at Aerojet for AMSU-A instrument testing, and the second is the workstation software used at the spacecraft integration facility to monitor the AMSU-A instrument when installed on the spacecraft. The primary use of the STE software is to monitor the data output from the AMSU-A instruments, to command the instruments, and to perform automated thermal-vacuum calibration testing. The primary use of the workstation software is to monitor the AMSU-A instrument's performance through an Ethernet link during the instrument/spacecraft integration process.

Schwantje, Robert↗

Containerless, Low-Gravity Undercooling of Ti-Ce Alloys in the MSFC Drop Tube

Previous tests of the classical nucleation theory as applied to liquid-liquid gap miscibility systems found a discrepancy between experiment and theory in the ability to undercool one of the liquids before the L1-L2 separation occurs. To model the initial separation process in a two-phase liquid mixture, different theoretical approaches, such as free-energy gradient and density gradient theories, have been put forth. If there is a large enough interaction between the critical liquid and the crucible, both models predict a wetting temperature (T(sub w)) above which the minority liquid perfectly wets and layers the crucible interface, but only on one side of the immiscibility dome. Materials with compositions on the other side of the dome will have simple surface adsorption by the minority liquid before bulk separation occurs when the coexistence (i.e., binoidal) line in reached. If the interaction between the critical liquid and the crucible were to decrease, T(sub w) would increase, eventually approaching the critical consolute temperature (T(sub cc)). If this situation occurs, then there could be large regions of the miscibility gap where non-perfect wetting conditions prevail resulting in droplets of L1 liquid at the surface having a non-zero contact angle. The resulting bulk structure will then depend on what happens on the surface and the subsequent processing conditions. In the past several decades, many experiments in space have been performed on liquid metal binary immiscible systems for the purpose of determining the effects that different crucibles may have on the wetting and separation process of the liquids. Potard performed experiments that showed different crucible materials could cause the majority phase to preferentially wet the container and thus produce a dispersed microstructure of the minority phase. Several other studies have been performed on immiscibles in a semi-container environment using an emulsion technique. Only one previous study was performed using completely containerless processing of immiscible metals and the results of that investigation are similar to some of the emulsion studies. In all the studies, surface wetting was attributed as the cause for the similar microstructures or the asymmetry in the ability to undercool the liquid below the binoidal on one side of the immiscibility dome. By removing the container completely from the separation process, it was proposed that the loss of the crucible/liquid interaction would produce a large shift in T(sub w) and thus change the wetting characteristics at the surface. By investigating various compositions across the miscibility gap, a change in the type and amount of liquid wetting at the surface of a containerless droplet should change the surface nucleating behavior of the droplet - whether it be the liquid-liquid wetting or the liquid-to-solid transition. Undercooling of the liquid into the metastable region should produce significant differences in the separation process and the microstructure upon solidification. In this study, we attempt to measure these transitions by monitoring the temperature of the sample by optical pyrometry. Microstructural analysis will be made to correlate with the degree of undercooling and the separation mechanisms involved.

Robinson, M. B.↗

Temperature Pill

Ingestible Thermal Monitoring System was developed at Johns Hopkins University as means of getting internal temperature readings for treatments of such emergency conditions as dangerously low (hypothermia) and dangerously high (hyperthermia) body temperatures. ITMS's accuracy is off no more than one hundredth of a degree and provides the only means of obtaining deep body temperature. System has additional applicability in fertility monitoring and some aspects of surgery, critical care obstetrics, metabolic disease treatment, gerontology (aging) and food processing research. Three-quarter inch silicone capsule contains telemetry system, micro battery, and a quartz crystal temperature sensor inserted vaginally, rectally, or swallowed.

Source record↗