Precision Polishing of Spheres Via In-Situ Process Monitoring and Machine-Learning-Based Optimization

Precision polishing for high surface finish is a vital step in the making of many high-tech components for optical and semiconductor modules as well as for wide ranging experimental samples for HED science that is at the core of LLNL’s mission. In particular, the fabrication of extremely smooth and round spheres comprised of low atomic number materials (low-Z such as high-density carbon or HDC, beryllium, hydrocarbon polymers, etc.) for Inertial Confinement Fusion (ICF) is entirely reliant on specialized polishing processes to achieve the surface smoothness.

36 MATERIALS SCIENCE↗

Precision Polishing of Spheres Via In-Situ Process Monitoring and Machine-Learning-Based Optimization

In inertial confinement fusion (ICF) experiments seeking output gains of unity and beyond, the quality of the ablator capsule is paramount for minimizing hydrodynamic mix that quenches the central hot spot. Defects in the form of foreign particles or missing mass on the surface and within the wall of the capsule are primary offenders. High density carbon capsules made for ICF experiments on the National Ignition Facility (NIF) are precision polished to achieve the surface smoothness in the order of a few nm as well as to minimize isolated defects in the form of pits. Given the critical role of this process, we are developing smart manufacturing techniques with goal of elevating the efficiency of this process. Our approach is to use MEMS-based sensors to capture the fine vibrational signals generated during the polishing process and combine it with synchronized visual feedback as needed. Beyond using these sensors for process monitoring, we use specific deep learning methods to analyze the data and extract correlations with both the process parameters and the final performance of the polishing run. Here, we describe the multiple fronts that we have explored in this regard and the results we have gotten so far. This approach promises to have the potential to ultimately provide real-time feedback that can be used for ensuring the progress of the run as well as a means for faster optimization.

36 MATERIALS SCIENCE↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Precision spectroscopy of nuclear decays using quantum optomechanical sensors

This project developed and demonstrated a fundamentally new way to detect individual nuclear decays: rather than capturing the energy that decay products deposit in a detector, we measure the tiny mechanical recoil of the entire micron- or nanometer-sized particle in which the decaying nucleus is embedded. Because momentum is conserved, this approach is sensitive even to neutral, weakly interacting particles, including neutrinos, that escape conventional detectors. During the award, the Yale group reported the first-ever mechanical detection of single nuclear decays, a result featured widely in the scientific press, and pushed the sensitivity of smaller levitated nanoparticles into the quantum measurement regime, reaching an impulse resolution within a factor of five of the fundamental Standard Quantum Limit (SQL), good enough in principle to detect the momentum kicked to the particle by a single emitted neutrino. In parallel, the LBNL group developed the theory of quantum-enhanced (sub-SQL) readout tailored to this experiment, showing how squeezed light can push the sensitivity below the SQL. Together these results establish levitated optomechanical sensors as a new tool for precision nuclear decay spectroscopy, with further applications in neutrino physics, quantum metrology, and nuclear forensics and safeguards.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expendable Precision Laser Aimer for Shaped Charges

Certain shaped-charge cutting operations require a precision aiming system that is operationally convenient, robust, and constructed to allow the aiming system to be left in place for last-minute alignment verification until it is expended when the charge is fired. This report describes an aiming system made from low cost doubled-Nd:YAG 532 nm laser modules of the type used in green laser pointers. Drawings and detailed procedures for constructing the aiming system are provided, as are the results of some minimal tests performed on a prototype device.

42 ENGINEERING↗

Hybrid method for the precise calculation of the general dyadic Greens functions for SAW and leaky wave substrates.

Recently, the generalized method for calculation of the 16-element Green's function for analysis of surface acoustic waves has proven crucial to develop more sophisticated transducers. The generalized Green's function provides a precise relationship between the acoustic stresses and electric displacement on the three mechanical displacements and electric potential. This generalized method is able to account for mass loading effects which is absent in the effective permittivity approach. However, the calculation is numerically intensive and may lead to numerical instabilities when solving for both the eigenvalues and eigenvectors simultaneously. In this work, the general eigenvalue problem was modified to eliminate the numerical instabilities in the solving procedure. An algorithm is also presented to select the proper eigenvalues rapidly to facilitate analysis for all types of acoustic propagation. The 4 x 4 Green's functions and effective permittivities were calculated for materials supporting Rayleigh, leaky, and leaky longitudinal waves as demonstration of the method.

97 MATHEMATICS AND COMPUTING↗

High-precision gamma-ray total cross-section measurements between 3.45 and 12 MeV

A Compton-backscatter capability has recently become available at the Duke University Free Electron Laser Laboratory. This capability allows one to produce high fluxes of tunable, nearly monoenergetic gamma rays. Using these gamma-ray beams, we have made high-precision (~0.5%) measurements of the gamma-ray total cross section at 3.45, 4, 5, 6, 8, 10, and 12 MeV. The nuclei measured were Be, C, Cu, Ta, W, Pb, and U

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Precision Measurement of the Neutral Pion Lifetime via the Primakoff Effect

The neutral pion radiative width has been measured to 8.411 eV ± 1.8% + 1.13% - 1.70% (lifetime = 7.826 ± 0.14 + 0.088 - 0.133 x 10 -17 s) utilizing the Primakoff effect and roughly 4.9 to 5.5 GeV photons at the Thomas Jefferson National Accelerator Facility in Newport News, VA. The Hall B Photon Tagger, the Hall B Pair Spectrometer, a state of the art Hybrid Calorimter enabled precision incident photon energy measurement, photon flux measurement, and neutral pion identification, respectively. With these and other hardware and software tools, elastic neutral pion yields were extracted from the data. A well developed and understood simulation calculated geometric and software cut efficiency curves. The simulation also provided photo-pion production response functions to fit the experimental cross sections and extract the Primakoff cross section and thus the neutral pion radiative width and lifetime. Future work includes improving understanding of the nuclear incoherent process and any other background sources of elastic neutral pions in this data.

43 PARTICLE ACCELERATORS↗

Precise measurement of the nuclear dependence of the EMC effect at large X

Experiment E03-103, carried out in Hall C at the Thomas Jefferson National Accelerator Facility, measuring inclusive electron scattering cross sections from nuclear targets over a broad range of x (0.3 < x < 1) up to Q 2 ≈ 8GeV 2 . The bulk of the data were taken at a beam energy of 5.8 GeV, with beam currents ranging from 30 to 80 μA. This dissertation describes the experiment in detail, and presents the extracted EMC ratios for the cryogenic targets 3 He, 4 He and solid targets Be, C, Cu, and Au. Our data provide the first measurement of the EMC effect in 3 He at x > 0.4, and improve the known precision of the existing measurements of the effect in 4 He and other nuclear targets at large x. The data have also been analyzed in terms of the structure function F$A\atop{2}$ to examine the scaling of the inelastic scattering in x and ξ.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Measurements of Tau Lepton Decays

Using data collected with the BABAR detector at the SLAC PEP-II electron-positron storage ring operating at a centre-of-mass energy near 10.58 GeV, the branching fractions B(τ - → π - π - π + ντ) =(8.83±0.01±0.13)%, B(τ - → K - π - π + ντ) =(0.273± 0.002 ± 0.009)%, B(τ - → K - π - K+ντ) =(0.1346 ± 0.0010 ± 0.0036)%, and B(τ - → K - K - K+ντ) =(1.58 ± 0.13 ± 0.12) × 10 -5 are measured where the uncertainties are statistical and systematic, respectively. The invariant mass distribution for the τ - → π - π - π+ντ , τ - → K - π - π+ντ , τ - → K - π - K+ντ and τ - → K - K - K+ντ decays are unfolded to correct for detector effects. A measurement of B(τ - → φπ - ντ ) =(3.42±0.55±0.25)×10 -5 , a measurement of B(τ - → φK - ντ) =(3.39±0.20±0.28)× 10 -5 and an upper limit on B(τ - → K - K - K+ντ [ex.φ]) ≤ 2.5 × 10 -6 @90%CL are determined from a binned maximum likelihood fit of the τ - → K - π - K+ντ and τ - → K - K - K+ντ K+K - invariant mass distributions. The branching ratio B(τ - →K - ν τ )/ B(τ - →π - ν τ ) is measured to be (6.531±0.056±0.093)×10 -2 from which |Vus| is determined to be 0.2255 ± 0.0023. The branching ratio B(τ - →μ - ν τ $\bar{v}$ μ )/ B(τ - →e - ν τ $\bar{v}$ e ) =(9.796 ± 0.016 ± 0.035) × 10 -1 is measured enabling a precision test of the Standard Model assumption of charged current lepton universality, gμ ge =1.0036 ± 0.0020. The branching ratios B(τ - →K - ν τ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(3.882 ± 0.032 ± 0.057) × 10 -2 , and B(τ - →π - ντ ) /B(τ - →e - ν τ $\bar{v}$ e ) =(5.945 ± 0.014 ± 0.061) × 10 -1 are measured which provide additional tests of charged current lepton universality, g τ /g μ π = 0.9856 ± 0.0057 and g τ /g μ K = 0.9827 ± 0.0086 which can be combined to give g τ /g μ π/K = 0.9850 ± 0.0054 . Any deviation of these measurements from the expected Standard Model values would be an indication of new physics.

43 PARTICLE ACCELERATORS↗

Precision measurement of the mass and width of the W boson at CDF

A precision measurement of the mass and width of the W boson is presented. The W bosons are produced in proton antiproton collisions occurring at a centre of mass energy of 1.96 TeV at the Tevatron accelerator. The data used for the analyses is collected by the Collider Detector at Fermilab (CDF) and corresponds to an average integrated luminosity of 350 pb -1 for the W width analysis for the electron and muon channels and an average integrated luminosity of 2350 pb -1 for the W mass analysis. The mass and width of the W boson is extracted by fitting to the transverse mass distribution, with the peak of the distribution being most sensitive to the mass and the tail of the distribution sensitive to the width. The W width measurement in the electron and muon channels is combined to give a final result of 2032 ± 73 MeV. The systematic uncertainty on the W mass from the recoil of the W boson against the initial state gluon radiation is discussed. A systematic study of the recoil in Z → e + e - events where one electron is reconstructed in the central calorimeter and the other in the plug calorimeter and its effect on the W mass is presented for the first time in this thesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision moisture generation and measurement.

In many industrial processes, gaseous moisture is undesirable as it can lead to metal corrosion, polymer degradation, and other materials aging processes. However, generating and measuring precise moisture concentrations is challenging due to the need to cover a broad concentration range (parts-per-billion to percent) and the affinity of moisture to a wide range surfaces and materials. This document will discuss the techniques employed by the Mass Spectrometry Laboratory of the Materials Reliability Department at Sandia National Laboratories to generate and measure known gaseous moisture concentrations. This document highlights the use of a chilled mirror and primary standard humidity generator for the characterization of aluminum oxide moisture sensors. The data presented shows an excellent correlation in frost point measured between the two instruments, and thus provides an accurate and reliable platform for characterizing moisture sensors and performing other moisture related experiments.

36 MATERIALS SCIENCE↗

High precision tune and coupling measurements and tune/coupling feedback in RHIC

Precision measurement and control of the betatron tunes and betatron coupling in RHIC are required for establishing and maintaining both good operating conditions and, particularly during the ramp to high beam energies, high proton beam polarization. While the proof-of-principle for simultaneous tune and coupling feedback was successfully demonstrated earlier, routine application of these systems has only become possible recently. Following numerous modifications for improved measurement resolution and feedback control, the time required to establish full-energy beams with the betatron tunes and coupling regulated by feedback was reduced from several weeks to a few hours. A summary of these improvements, select measurements benefitting from the improved resolution and a review of system performance are the subject of this report.

43 PARTICLE ACCELERATORS↗

New Precision Measurements of Deuteron Structure Function A(Q) at Low Momentum Transfer

Differences between previous measurements of low momentum transfer electron-deuteron elastic scattering prevent a clean determination of even the sign of the leading low momentum transfer relativistic corrections, or of the convergence of chiral perturbation theory. We have attempted to resolve this issue with a new high-precision measurement in Jefferson Lab Hall A. Elastic electron scattering was measured on targets of tantalum, carbon, hydrogen, and deuterium at beam energy of 685 MeV. The four-momentum transfer covered the range of 0.15 - 0.7 GeV. The experiment included a new beam calorimeter, to better calibrate the low beam currents used in the experiment, and new collimators to better define the spectrometer solid angles. We obtained cross sections of deuteron as ratios to hydrogen cross sections. A fit function of B(Q) world data is newly made and subtracted from cross sections to find values of A(Q).

08 HYDROGEN↗

Precision Electroweak Measurements at the LHC and Tevatron

Various electroweak precision measurements are performed at the hadron colliders Tevatron and LHC.The main ones regard the masses of the W boson, top quark and Higgs boson, and sin 2 theta^l_eff.This talk covers the latter and also other measurements carried out using Drell--Yan decays.The results of the sin 2 theta^l_eff measurements have an accuracy of approximately twice that reached at LEP and SLD. The LEP and SLD accuracy is expected to be approached with Run 2 and Run 3 data and surpassed with high-luminosity LHC data.Other measurements reported are the differential distributions and the full set of decay angular coefficient in Drell--Yan events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating the DUNE LArTPC detectors for precision physics

The Deep Underground Neutrino Experiment (DUNE) is an international collaboration focused on studying neutrino oscillation over a long baseline (1300 km). DUNE will make use of a near detector and $\mathcal{O}$(GeV) neutrino beam originating at Fermilab in Batavia, IL, and a far detector operating 1.5 km underground at the Sanford Underground Research Facility in Lead, South Dakota. The near and far detectors will use the LArTPC (Liquid Argon Time Projection Chamber) technology to image neutrino interactions. In order to make precise physics measurements at DUNE, such as the amount of CP violation in the neutrino sector, it is essential to be able to accurately reconstruct particle energies and other kinematic quantities; this in turn necessitates an extensive calibration program for DUNE s LArTPC detectors. In this presentation, we describe the requirements for calibrating the DUNE detectors, emphasizing the challenges of massive multi-kiloton LArTPC detectors which are to operate for multiple years deep underground. A preliminary DUNE detector calibration program, including use of both dedicated calibration hardware and cosmogenic/beam-induced calibration sources, is presented. First results on detector calibration at the ProtoDUNE-SP prototype detector located at CERN, and associated impact on calibrations at the DUNE far detector, are also emphasized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗