Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power system control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,405 records · Page 78

Improving Cost and Efficiency of the Scalable Solid Oxide Fuel Cells Power System

The objective of this project was to design and develop a 20kW range small-scale solid oxide fuel cells (SOFC) power system for applications such as data centers and commercial buildings. The original plan included a 5,000 hours demonstration and a Techno-Economic Analysis (TEA) which were dropped as part of project termination. The original project plan was to use a stack with a cross-flow cell design which had previously been tested for 500 hours at a community college in Malta, NY. However, it was decided to move to the advanced R-SOFC co-flow cell developed under Department of Energy Award DE-FE0031971. The advanced cell design has the advantage of a larger active area for the same manufacturing footprint which results in fewer required cells for the same stack power, hence a higher volumetric power density (kW/L) and lower cost per kW than the original cross-flow cell design. A full SOFC system Simulink model was developed and calibrated with testing data from a fuel cell stack and BOP (balance of plant) components. The simulation results from the calibrated model showed an acceptable match with the experimental data. A structural analysis conducted for various load scenarios indicated no high stress areas for all spatial directions. Major electrical system components were acquired, built and successfully tested. System sensors were verified and validated against controls. Safety checks, a diagnostic check, PID tuning, and control software commissioning tasks were also conducted. The power electronics prototype was delivered and trial testing completed. Balance of Plant component testing and simulation work was conducted to characterize Reformer-Heat Exchanger heat transfer and backpressure and reformer catalyst methane conversion and product selectivity. Simulations were conducted to design the Anode and Cathode fluid passages and size the air-air and fuel-fuel heat exchangers. A Burner operation map was created from test data and the Anode Gas Recirculation blower was tested to evaluate its durability. The SOFC system used a horizontal style design where components sit directly on a casting with a direct connection to the skid. This design has efficient packaging and a small footprint with approximate dimensions of 750 mm x 700 mm x 1700 mm. An SOFC system was built and successfully tested at the Malta, NY facility The system for over 500 hours under load of which over 300 hours was at full load of 20 kW.

30 DIRECT ENERGY CONVERSION↗

Model Quality and Measurement Density Impact on Volt/Volt Ampere Reactive Optimization Performance

The operation of the utility grid is being reshaped by the continuous addition of distributed energy resources and advanced metering infrastructure, which challenge existing grid control strategies. Some utilities deploy advanced distribution management systems (ADMS) to assist with the consolidation of various applications and to augment situational awareness in response to the new power delivery dynamics. An ADMS is an integrated software platform that provides utilities with a way to enhance their reliability, control, and optimization with advanced applications, such as volt/VAR optimization (VVO). A VVO application could serve as a vehicle to deliver cost savings by providing the utility with a method to reduce rates by controlling the voltage and decreasing the energy usage in their service territory. Some utilities are reluctant to integrate an ADMS, because it is a significant investment that requires approval from the public regulatory commission and/or their customers. This paper evaluates the impact on VVO performance when using a lower-quality network model supplemented with additional measurements, which could provide an implementation for cost savings. The results show that a better model quality would provide the highest energy savings; however, some level of telemetry is necessary in all scenarios to prevent voltage exceedances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Virtual synchronous generator system and method with virtual inertia control

A virtual synchronous generator device disclosed. The device includes an inverter and inverter controller having a power control portion, a power reserve portion, a power point tracking control portion, and a virtual inertia control portion. The power reserve portion determines an amount of power to be reserved and sends a signal, indicative of the determined amount of power to the power point tracking controller. The power point tracking controller determines a power point that is less than a MPP, and provides a signal to the power control portion indicative of the determined power point. The inertia control portion determines a virtual inertia and provides a signal indicative of the virtual inertia to the power control portion. The power control portion provides a power control signal to the inverter based on the power point tracking signal and the inertia command signal.

42 ENGINEERING↗

A Relaxed PV Bus Model in Linear Power Flow

The emerging multimodal active energy resource units make it necessary to introduce constant voltage amplitude buses (PV bus) in the operation of modern distribution systems. To enable the analysis of PV bus using linear power flow models, this letter proposes a relaxed PV bus model for solving power flow related problems using an indirect modeling approach. The developed PV bus model can be applied to linear power flow models in both rectangular and polar coordinates. Besides, the approximation error of the relaxed PV bus model can also be controlled and quantified. Lastly, the proposed relaxed PV bus model is validated using different test systems. According to the numerical studies, the maximum error on the PV bus approximation in all case studies is only 0.61%, and the maximum error of the supporting power at the PV buses is 6.5%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-Fidelity Modeling and Control for Building Temperature Control

The ability to control energy loads such as a building's heating, ventilation, and air conditioning (HVAC) system can help facilitate increased penetration of variable renewable energy sources into the electric grid. To be able to control these HVAC systems more effectively, detailed simulations of the corresponding building physics is becoming increasingly important. These detailed simulations can be complex, nonlinear, and can require immense computational power when used in an advanced control method such as model predictive control (MPC), prompting the need to explore less computationally intensive strategies. In this work, a multi-fidelity approach is proposed to combine samples from a complex, high-fidelity model with a simple, low-fidelity model within the MPC control loop. More specifically, the parameters of a reduced-order, linear building model are periodically updated with knowledge from its high-fidelity counterpart - an EnergyPlus model - in an online fashion using a Gaussian Process surrogate model. Hence, highly accurate predictions of current and future conditions in a building are maintained with a substantially reduced computational burden compared to using the high-fidelity models alone. In other words, this linear parameter varying model preserves the low computational requirements of a low-order linear model while accurately modeling a building's dynamics. This allows a building controller to take highly informed actions without requiring a large computational budget.

building modeling↗

Dynamic Modeling of Full Converter Adjustable-speed Pumped Storage Hydropower (FC AS-PSH)

Full converter adjustable-speed pumped storage hydropower (FC AS-PSH) technology, as one of advanced-PSH technology, is developed from wind turbine technology. By making the synchronous machine connect to the grid through a full-size converter, FC AS-PSH has a wider adjustment range of speed and a better reactive power control capability compared with a doubly-fed asynchronous generator AS-PSH technology. When it plays as an energy backup in the power system, FC AS-PSH can provide a much faster response than conventional-PSH (C-PSH) which makes this technology provide better ancillary service for a high renewable penetrated system. In this paper, the dynamic modeling of FC AS-PSH is fully studied. We develop a detailed model of this technology in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform. Especially, the first governor model is developed based on the Engineer’s Program Control Language (EPCL) user-defined model in this platform. All operation modes are validated and studied under a system contingency. Besides, comparison cases between FC AS-PSH and C-PSH are studied to show advantages providing from FC AS-PSH when it works with renewable energy.

50 EE - Wind and Water Power Program - Water (EE-4↗

FRIB Beam Power Ramp-up: Status and Plans

After project completion on scope, on cost, and ahead of schedule, the Facility for Rare Isotope Beams began operations for scientific users in May of 2022. The ramp-up to a beam power of 400 kW is planned over a six-year period; 1 kW was delivered for initial user runs from in 2022, and 5 kW was delivered as of February 2023. Test runs with 10 kW 36Ar and 48Ca beams were conducted in July 2023. Upgrade plans include doubling the primary-beam energy to 400 MeV/nucleon for enhanced discovery potential (¿FRIB 400¿). This talk reports on the strategic plans towards high power operations emphasizing challenges and resolutions in beam-interception devices and targetry systems, radiation protection and controls, and legacy system renovation and integration.

43 PARTICLE ACCELERATORS↗

Integrated Renewable Energy Systems

Pacific Northwest National Laboratory (PNNL) operates the Department of Energy’s (DOE) only dedicated marine laboratory at the PNNL-Sequim campus. PNNL is leading research in the blue economy and marine energy applications and building collaboration between DOE and multiple partners in the state of Washington and beyond. With Washington State support, the Integrated Renewable Energy System (IRES) demonstration testbed proposed here will advance research by developing and testing renewable energy production, management, and use for multiple marine applications (e.g., ocean observations, underwater vehicles, aquaculture). It will also advance energy resiliency for coastal communities by developing an integrated renewable energy test platform that will model how multiple renewable energy resources could power shoreline businesses or communities (Figure 1). The test bed will demonstrate how different renewable systems can be integrated to reduce carbon emissions and contribute to a net zero emissions site and provide lessons, controls, and protocols that will help to expand energy options for shoreline and maritime businesses. The integrated system is expected to serve as a test bed for shoreline power and ocean energy technologies for years to come.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Isolated Single-stage Three-phase AC/DC Converter using Bidirectional Switches

The advent of the SiC Bidirectional FET (BiDFET), a monolithic 1.2 kV bidirectional switch, has rendered the single-stage three-phase AC/DC converter topology a promising approach for implementing AC/DC converters. This topology, which integrates a full-bridge converter with a single-phase to three-phase matrix converter via a high-frequency transformer, is particularly suitable for applications requiring galvanic isolation, buck-boost functionality, and bidirectional power flow. The single-stage design eliminates the need for bulky and unreliable electrolytic capacitors, and utilizes a single magnetic component for power transfer. In the matrix converter, bidirectional switches, which were traditionally implemented using combinations of multiple semiconductor devices such as MOSFETs, IGBTs, and diodes, can now be realized using the single-chip solution, BiDFET. This advancement leads to a lower switch count, compact converter implementation, with lower inductance commutation cells, thereby enhancing the overall efficiency and compactness of the system. The paper presents a unified model of the converter, considering all control parameters, including the duty cycles and phase shift of transformer voltages. Detailed expressions for power transfer, transformer currents, and currents at AC and DC ports are provided. Additionally, the paper outlines the conditions necessary for soft-switching of all switches and the commutation schemes required for the practical implementation of the matrix converter modulation scheme. A hardware prototype of a 10 kW, 480 VRMS, LL/ 800 V AC/DC system has been developed, and experimental results are presented to demonstrate its performance.

BiDFET↗

Upgrading Fermilab’s accelerator control system with ACORN

The Fermilab Accelerator Complex is the largest national user facility in the Office of High Energy Physics (DOE/HEP) program and the only national user facility operating at Fermilab. Fermilab serves as the host to the Long Baseline Neutrino Facility/Deep Underground Neutrino Experiment (LBNF/DUNE), the laboratory’s flagship project for neutrino science that is under construction. LBNF/DUNE will be powered by megawatt beams from an upgraded accelerator, the Proton Improvement Plan II (PIP-II) that will replace the laboratory’s aging linear accelerator with a new one based on superconducting radio-frequency cavities. The Accelerator Controls Operations Research Network (ACORN) Project will support LBNF/DUNE and PIP-II by modernizing the accelerator control system. The project is at the conceptual design phase and looking to achieve Critical Decision 1 (CD-1) later this year. The scope and structure of the project will be presented, along with an overview of how that has changed in the past year. Current design and technology choices will be shared. Specific challenges facing the project will be addressed, along with current thinking on solutions.

Roehrig, Christian [Fermilab]↗

Motion Control of Hydraulic Actuators In the Presence of Discrete Pressure Rail Switching

Conventional off-highway mobile machines are hydraulically actuated and have poor energy efficiencies. The goal to increase system efficiency and to reap the benefits of electrification have led to the creation of a novel Hybrid Hydraulic-Electric Architecture (HHEA) which could significantly increase efficiency, decrease the sizes and cost of electrical components, and maintain control performance. The key concept is to utilize a set of common pressure rails to provide the majority of power via the power dense hydraulics and to modulate that power by small electric components, which are less power dense, for precise control. The paper presents the motion control strategy for this architecture. The architecture presents a distinct challenge in that as the energy minimization algorithm selects different pressure rails, the system could experience large discrete jumps in pressures that impact control performance, especially when the electric components are torque limited. To meet this challenge, a passivity based back-stepping controller is used as the nominal controller between pressure rail switching events and a separate transition controller is used to deal with the pressure rail switching events. Two transition controllers are proposed, one uses the electric motor torque as the input, and the other also uses valve timing as a second input. For both transition controllers, a least norm control approach is used to steer the system states to the exact desired states at the end of the short transition period (~ 40 ms). The transition controllers are able to reduce the tracking error and the required electric motor torque, and hence achieve better control performance even with smaller electric components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solid State Power Substations (SSPS): A Multi-Hierarchical Architecture from Substation to Grid Edge

With the growing deployment of distributed generation, or power electronic interfaced renewable energy and storage technologies, the nature and behavior of the grid is changing. Synchronous machine-driven asset contributions to the generation mix are shrinking, leading to concerns regarding grid stability. Furthermore, the scale of smaller distributed PE resources needed for managing the electrical network could dwarf the existing system leading to more complex optimization problems and communication interconnections. This paper introduces the concept of a hierarchal system of controllers that spans the grid edge or the customer end to distribution scale substations or solid-state power substation (SSPS). This concept focuses on minimizing the number of interfaces and optimization considerations in the grid by clustering resources into nodes and hubs. The work validates the concept in a controller hardware-in-the-loop (cHIL) platform.

Chinthavali, Madhu Sudhan↗

Combined Raman and Turbidity Probe for Real-Time Analysis of Variable Turbidity Streams

We know that real-time and in situ process monitoring is a powerful tool that can empower operators of hazardous processes to better understand and control their chemical systems without increased risk to themselves. However, applying monitoring techniques to complex chemical processes can face challenges. An example of this is the application of optical spectroscopy, otherwise capable of providing detailed chemical composition information, to processes exhibiting variable turbidity. Here, details on a novel combined Raman spectroscopy and turbidimetry probe are discussed. Furthermore, the analytical approach to accurately account for both Raman signal and turbidity while quantifying chemical targets is detailed. Through leveraging Raman and turbidity data simultaneously collected from the combined probe within chemometric models, accurate quantification of multiple chemical targets can be achieved under conditions of variable concentrations and turbidity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Moiré trions in MoSe 2 /WSe 2 heterobilayers

Transition metal dichalcogenide moiré bilayers with spatially periodic potentials have emerged as a highly tunable platform for studying both electronic and excitonic phenomena. The power of these systems lies in the combination of strong Coulomb interactions with the capability of controlling the charge number in a moiré potential trap. Electronically, exotic charge orders at both integer and fractional fillings have been discovered. However, the impact of charging effects on excitons trapped in moiré potentials is poorly understood. Here, we report the observation of moiré trions and their doping-dependent photoluminescence polarization in H-stacked MoSe 2 /WSe 2 heterobilayers. We find that as moiré traps are filled with either electrons or holes, new sets of interlayer exciton photoluminescence peaks with narrow linewidths emerge about 7 meV below the energy of the neutral moiré excitons. Circularly polarized photoluminescence reveals switching from co-circular to cross-circular polarizations as moiré excitons go from being negatively charged and neutral to positively charged. Furthermore, this switching results from the competition between valley-flip and spin-flip energy relaxation pathways of photo-excited electrons during interlayer trion formation. Our results offer a starting point for engineering both bosonic and fermionic many-body effects based on moiré excitons.

36 MATERIALS SCIENCE↗

Rapid Monitoring and Defense Approach for Resilience Improvement of Grid Cyber Security

Cyber-physical systems and electric utilities significantly depend on the reliability and efficiency of information and operational technology. However, false data injection attacks based on synchrophasor measurement data pose a serious threat to the safe and reliable operation of modern power systems. Here, to mitigate this problem, a rapid monitoring and defense approach is proposed to defend against cyber attacks. Initially, the Time and Frequency based Convolutional neural Network (TFCN) is proposed to detect different types of attacks. Within the TFCN, the advances are that both time and frequency domain information can be fused without extra spectrum analysis methods, and can save detection time to speed the calculation efficiency using the developed time-frequency block. Next, a comprehensive defense strategy is developed for multiple cyber attacks to ensure the stability and resilience of the power system according to the feedback detection results. The advances of this strategy are that different control strategies can be automatically selected to recover the stability to the greatest extent according to the detected attacks. To verify the effectiveness of the proposed approach, the high-speed frequency measurements collected from the wide-area monitoring system are used. The results demonstrate that the cyber attack detection performance can reach 95.57% accuracy, outperforming both traditional and some advanced neural networks. Importantly, the defense strategy is conducted and verified in a modified IEEE 39 bus system as well, which illustrates profound performance in faster stability restoration.

Comprehensive defense strategy↗

Analyzing Gas Turbine-Generator Performance of the Hybrid Power System

We report kinetic energy available from the turbomachinery may boost short-term ramp rates during load shifting between generator and fuel cell that may be exploited to optimize the performance of turbine-fuel cell hybrid systems during load following. The paper starts with modeling a gas turbine, gearbox, and generator sitting on the rigid shafts as a two-mass model primarily for estimating the rotational inertia available from the turbogenerator. The gas turbine and its environment impose constraints of available space allowances, measurements from high-speed rotating parts, lack of accessibility to the shaft of measure, making replacements and/or required installation adjustments of the torque transducer difficult. It is demonstrated that in the absence of torque measurement, the data containing only a slow excursion of the rotor motion in response to a slight load change is sufficient to determine inertia and damping coefficients from the model. Furthermore, the generator’s reactive power capability was investigated because it serves as an asset in integrated hybrid systems to meet dynamic reactive power demands, reducing the burden on the fuel cell’s power electronics control in generating reactive power.

24 POWER TRANSMISSION AND DISTRIBUTION↗